SDR DALA1100170632Skin · damagedLOG ITEM J614634-001, POSSIBLE RT SIDE ACFT LIGHTENING STRIKE. ACFT INSPECTED IAW AMM 05-51-19. DAMAGE TRANSFERRED TO NR'S 1 THRU 9. DAMAGE ON N/R'S 1-3 AND 5-9 C/W IAW SRM 53-00-01. DAMAGE ON N/R 4 (STA 418 STR 6L) C/W ON ERA 488577-14.SDR DALA1100735502Frame · crackedDURING L CHECK A CRACK WAS FOUND ON THE LOWER LOBE CARGO FRAME WEB AT STA 1440, BETWEEN S-25R AND S-26R. COMPLIED WITH ERA NR 488094-14, REV ORIGINAL. REPAIR APPROVAL IS LIMITED TO 12 MONTHS ONLY. ADDITIONAL EA IS REQUIRED.SDR DALA1100095503Light · brokenDURING LAYOVER CHECK, FOUND EMERGENCY LIGHT ASSY AT DOOR L4, BROKEN. REATTACHED EMERGENCY LIGHT SIGN. OPS CK GOOD.SDR UALA2010123004778Shutoff Valve · faultyLEFT ENGINE BLEED AIR VALVE 'OFF 'LIGHT NOT ON WITH SWITCH 'ON' & ENG RUNNING. DUCT PRESSURE WAS NORMAL. AFTER LT ENGINE START BLEED REMAINED OPEN, ONLY HAD 10 PSI DUCT PRESSURE, HAD TO TURN OFF BLEED TO STA. PRSOV VALVE REPLACED IAW AMM. ON ENG RUN IAW NSDR DALA1036715534Floor Support · corrodedDURING M-CHECK, FOUND RT DOOR SILL AT STA 365.25, FLOOR SUPPORT HAS SURFACE CORROSION OTBD OF RBL 53. R & R FLOOR SUPPORT FROM STA 348 TO 365.25 AT RBL 53 IAW REF SRM 51-40-02.SDR DALA1036775534Floor Support · crackedDURING M-CHECK, FOUND FWD CARGO BETWEEN STA 680 AND STA 660, 36" LT OF CTR THE FLOOR SUPPORT IS CRACKED. REMOVED FLOOR SUPPORT AND INTERCOSTAL WEB CRACKED. FABRICATED REPLACEMENT INTERCOSTAL WEB LOCATED AND DRILLED NEW INTERCOSTAL WEB. NDT VERIFIED FLOOR SUSDR UALA2010122804754Computer · faultyLT EICAS STATUS MESSAGE ON ARRIVAL WITH UPPER SCREEN INOP ON LT COMPUTER. PROBLEM FOLLOWS WHEN COMPUTERS SWAPPED. REPLACED LT EICAS COMPUTER. OPS GOOD.SDR DALA1100146810Frame · dentedFWD CARGO FRAME DENTED IN 2 PLACES ON UPPER FLANGE AND RADIUS, STA 540 FROM STR 24 TO 25 LT. REPAIRED IAW ER/A 488006-14 REV, ORIGINAL.SDR DALA1100156810Frame · dentedFWD CARGO FRAME DENTED ON UPPER FLANGE STA 520 FROM 24 TO 25 LT. REPAIRED IAW ER/A 488097-14.SDR DALA1100745502Stringer · corrodedAFT CARGO PIT S-29L HAS EXFOLIATION CORROSION AT STA 1660. REMOVED FLOOR PANEL AFT CARGO PIT AT STA 1510 TO 1640 IAW SRM 51-40-02, PG 10. REMOVED SUPPORT MOUNTING ASSY AND 2 EA CLIPS AND SPLICE ANGLE IAW SRM 51-40-02. FABRICATED AND INSTALLED REPLACEMENSDR DALA1036625519Sill · corrodedDURING M-CHECK, FOUND L1 DOOR SILL WEB TOP SURFACE SKIN CORRODED INCLUDING ADJACENT FLOORBEAM AT STA 365 & 377. CORROSION WAS ON FLOOR SUPPORTS NOT ON WEB. REMOVED CORROSION AREA IAW SRM 51-10-02 OUT OF LIMITS. RECEIVED NEW MATERIAL SUPPORT LOCATED AND DRILSDR UALA2010122704716Actuator · malfunctionedSPOILERS EICAS MESSAGE ON DESCENT WHEN SPOILER HANDLE IN USE INFLIGHT. FOUND "PCA 7 FAULT" DISPLAYED ON 3 LT SPOILER CONTROL MODULE M532, TYPE: INTERMIT, PHASE: DESCENT. DID NOT CLEAR MODULE MEMORY. SPOILER 6 AND 7 ARE LOCKED OUT IN THE DOWN POSITION. PERFSDR UALA2010122704721Bleed Valve · malfunctionedRT ENGINE BLEED VALVE CYCLING OPEN WITH RT ENGINE SHUTDOWN AND APU SUPPLYING AIR TO THE PACK. REPLACED PRSOV REGULATOR. OPS NORMAL.SDR UALA2010122704729Control System · failedCOCKPIT TEMP FAULT, FLIGHT DIVERTED. REPLACED THE LT PACK TEMP SENSOR AND LT PACK TEMP CONTROLLER VALVE. LT AIR CONDITIONER CHECKED GOOD.SDR UALA2010122704722Lead · unknownRAT POWER AND CONTROL CB TRIPPED. INITIAL REVIEW OF WDM 29-21-31 SHOWS CB LEADS TO RAT SOL ACTUATOR M10407.SDR DALA1053175645Battery Pack · inoperativeDURING A LINE CHECK, MX FOUND THE DOOR 1L EXTERNAL EMERGENCY LIGHT INOPERATIVE. MX REPLACED THE BATTERY PACK. OPS CHECK WAS GOOD.SDR UALA2010122704715Shutoff Valve · faultyRT BLEED CYCLES. VALVE IS MALFUNCTIONING. REPLACED NR 2 ENGINE PRSOV. IDLE RUN OPS CHECK OKAY.SDR DALA1053015645Battery Pack · inoperativeDURING A LINE CHECK, MX FOUND THE DOOR 3R EXTERNAL,AND RT FWD OVERWING EXTERNAL EMERGENCY LIGHTS INOPERATIVE. MX REPLACED THE BATTERY PACK. OPS CHECK FOR BOTH LIGHTS WAS GOOD.SDR DALA1053056702Charger · inoperativeDURING LAYOVER CHECK FOUND EMERGENCY ESCAPE PATH LIGHTS AT ROW 26-35 INOPERATIVE. REPLACED BATTERY PACK CHARGER. LIGHTS CHECKED OK.SDR UALA2010122704704Floorbeam · corrodedCORROSION FOUND ON FLOORBEAM AT STA 1640. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION AND DETERMINED THAT MATERIAL LOSS IS BEYOND LIMITS. R & R FLOORBEAM TEE CAP AND SPLICE ANGLE IAW SRM.SDR DALA1036645519Skin · damagedDURING M-CHECK FOUND LT WING INBD FLAP UPPER INBD SECTION PUNCTURED. REMOVED DAMAGED SKIN, POTTED HOLE, FABRICATED REPAIR DOUBLER, BONDED DOUBLER, SEALED AND PRIMED. WORK PERFORMED IAW SRM 51-70-10.SDR DALA1053005528Unknown · fumesDURING CLIMB, HAD MODERATE AMOUNT OF HAZE AND FUMES IN COCKPIT. CREW COMPLETED THE QRH SMOKE AND FUMES PROCEDURE AND THE VAPOR/MIST DISSIPATED. FLIGHT CONTINUED AND LANDED WITHOUT INCIDENT. RAN PACKS FULL HOT/COLDFROM APU AND BOTH ENGINES AT ALL POWER SETTINSDR DALA1036455533Skin · gougedDURING M-CHECK, FOUND ACCESS DOOR 119 BL HANDLE CUTOUT IS GOUGED. REPAIRED IAW ERA 488099-14, REV ORIGINAL.SDR DALA1036635502Cable · out of adjustDURING L-CHECK, L-1 DOOR FAILED, EMERGENCY POWER ACTUATION CABLE TRAVEL CHECK IAW T/C 5211-7001-1L, STEP 3, FOUND ADJUSTMENT STUD ON TRIGGER ASSY FULLY EXTENDED AND SPRING CLIP MISSING. REMOVED L-1 DOOR WAY LINER AT FWD SIDE OF DOOR IAW AMM 25-21-06-401, ADJUSDR DALA1053040617Battery Pack · looseDURING A-CHECK, FOUND 2 RT EXTERIOR OVERWING EMERGENCY LIGHTS DID NOT ILLUMINATE DURING TEST. SECURED LOOSE BATTERY PACK IN TRAY. ALL CHECKED GOOD.SDR DALA1052300679Skin · dentedFUSELAGE SKIN DENTED AT STA 622, BETWEEN STRINGERS 17L AND 18L. TIME LIMITED REPAIR WAS ACCOMPLISHED IAW ERA 484738-14. CATEGORY B, INTERIM REPAIR WAS ACCOMPLISHED IAW SRM 53-00-01, FIG 201 ON NR CARD 1 AT PSV 16.SDR DALA1052335649Battery Pack · inoperativeDURING A LINE CHECK, MX FOUND THE EMERGENCY EXIT LIGHT AT DOOR 4L AND ABOVE SEAT 40C INOPERATIVE. MX REPLACED BATTERY PACK M737. OPS CHECK WAS GOOD.SDR DALA1052770681Wire · damagedDURING A LAYOVER CHECK, MX FOUND THE EMERGENCY PATHLIGHTS AT SEATS 23, 37, & 45 INOPERATIVE. MX REPAIRED THE WIRING. OPS CHECK WAS GOOD.SDR DALA1100755502Pan · corrodedLAV SERVICE PAN HAS HEAVY CORROSION ON INSIDE SURFACE VIEWED THRU FWD CARGO LT SIDE WALL BETWEEN STA 700 AND 720 AT STR 21L. R & R PAN DOUBLER IAW SRM 51-40-02 AND DWG 143N3412.SDR DALA1036065533Skin · crackedDURING M-CHECK, FOUND DAMAGE ON LT ELEVATOR T/E CRACKED DUE TO IMPACT WITH A MANLIFT. REMOVED LT ELEVATOR IAW AMM 27-31-01-024-001 AND PERFORMED REPAIR IAW SRM 51-70-04, GENERAL PARAGRAPH 4D-4G PG 7-18, FIG 14, PG 48 AND REINSTALLED LT ELEVATOR AND PERFORMED SDR DALA1100406810Crease Beam · corrodedMAIN CABIN CREASE BEAM INNER CHORD CORRODED STA 333-377, LT AT L1 DOOR OPENING. REPLACED CHORD.SDR DALA1052310692Connector · damagedDURING A LAYOVER CHECK, MX FOUND THE EMERGENCY EXIT LIGHT AT 39DEF INOPERATIVE. MX RE-PINNED THE CONNECTOR. OPS CHECK WAS GOOD.SDR UALA2010122004637Module · faultyELEV ASYM STATUS MSG CAME ON. REPLACED LEFT STCM PER 27-09-00 BECAUSE MODULE PREVIOUSLY INSTALLED HAD ALL FAULT BALLS DISPLAYED & WOULD NOT RESET. NEW UNIT TESTED OK. THEN PERFORMED AUTOPILOT ADJ TEST PER MM.SDR DALA1036015519Floorbeam · corrodedDURING M-CHECK FOUND FWD CABIN FLOORBEAM PREVIOUS REPAIR FROM LBL 64 TO RBL 38 CORRODED AT 7 LOCATIONS AS MARKED AT BS 377.7. REMOVED CORROSION AREA BEAM FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, ORIG MATERIAL .125 MAX ALLOWABLE 10 PERCENT. REMOVED (2 EA) SDR DALA1036025519Floorbeam · corrodedDURING M-CHECK FOUND FWD CABIN FLOORBEAM, STN 365 PREVIOUS REPAIR FROM LBL 15 TO RBL 64 CORRODED AT SEVERAL LOCATIONS AS MARKED. BLENDED AREA ON FLOORBEAM FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101. FABRICATED NEW UPPER CHORD TREATED AND PRIMED NSDR UALA2010121704606Elt · out of toleranceREPLACED ELT ON RAFT NR1 AND RAFT NR 2 IAW AMM ON TASK CARD 2355N00700.SDR DALA1052260689Wire Harness · inoperativeDURING LAYOVER CHECK, MX FOUND SEAT 24D AND 40D EMERGENCY ESCAPE LIGHTS INOPERATIVE. MX REPLACED THE WIRE HARNESS AND PERFORMED EMERGENCY LIGHTS TEST IAW AMM. CHECKS GOOD. (20010-D1520)SDR UALA2010122004636Module · faultySTATUS MESSAGE: "ELEV ASYM" REPLACED STAB TRIM-AIR LOCK-ASYM-MODULE PER MM, GROUND CHECK NORMAL.SDR DALA1035875521Skin · dentedDURING L-CK, DENTS WERE FOUND IN FUSELAGE SKIN AT STA 610 S-15L TO S16L. DENTS WERE CUT OUT AND EXTERNAL DOUBLER WAS INSTALLED. SECTION II PERMANENT REPAIR LIMITED TO 69,700 TOTAL ACFT CYCLES. ADDITIONAL ER/A REVISION REQUIRED FOR CONTINUED SERVICE OF THIS SDR UALA2010121704602Engine · fluctuatesRT ENG DUCT PRESSURE FLUCTUATES. FLUCTUATES BETWEEN 20-40 PSI ALSO VARIES W PACK OFF. PER FLIGHT CREW FLUCTUATION AT CRUISE AND DESCENT RIGHT DUCT PRESS NEVER EXCEEDED LEFT SIDE, RIGHT OFF LIGHT ON AND OFF ON DESCENT. ENGINE WAS REPLACED. ACCOMPLISHED PNESDR DALA1052256703Ballast · overheatedWHILE ON APPROACH A STRONG ELECTRICAL/BURNED PLASTIC SMELL WAS REPORTED. CREW TURNED OFF THE RECIRCULATION FANS AND THE SMELL DISSIPATED SOON AFTER THE ACFT LANDED. MX FOUND A LIGHT BALLAST INOPERATIVE AND MEL'D THE SAME. REPLACED BALLAST. LIGHTS OPERATE NORSDR DALA1100306810Frame · dentedFWD CARGO FRAME DENTED STA 660 ON UPPER FLANGE BTWN STR 23 & 24 LT. REPAIRED IAW 53-00-07, FIG 201, REPAIR 5.SDR DALA1035785533Crease Beam · corrodedDURING MX CORROSION WAS FOUND COMMON TO THE FUSELAGE CREASE BEAM AT STA 1630, WL 208. THE CORRODED AREA OF THE CREASE BEAM WAS CUTOUT AND A REPAIR WAS INSTALLED IAW SECTION OF ER/A 13-487261-14. THE REPAIR IAW SECTION I IS STATICALLY APPROVED FOR 24 MONTHS AFSDR UALA2010121504578Floorbeam · corrodedMAIN CABIN AFT PRESSURE DECK AT BS 1706 AND RBL 52 IS CORRODED. MAJOR REPAIR ACCOMPLISHED: REPAIRED AFT FLOOR SUPPORT DECK AT STA 1706 IAW EA 57-53-066. THIS A PERMANENT REPAIR AND REQUIRES NO FURTHER ACTION.SDR UALA2010121504589Pump · failedCTR FUEL TANK RT OVERRIDE BOOST PUMP FAILED TEST. REPLACED CTR TANK RT OVERRIDE BOOST PUMP. OPS ARE GOOD.SDR UALA2010121504576Gate · corrodedL1 DOOR LOWER GATE CORRODED. ACCOMPLISHED REPAIR IAW WOO-37 NRI.SDR UALA2010121504577Bearing · wornR1 DOOR TORQUE TUBE COCKING ROD END BEARING WORN. REPLACED IAW MM ON WOO-34NR1.SDR UALA2010121504579Floorbeam · corrodedFLOORBEAM AT STATION 1681 ON RBL 38 CORRODED ON UPPER AND LOWER SURFACE OF FWD SIDE OF TEE. MAJOR REPAIR ACCOMPLISHED: REPAIRED FLOORBEAM AT STA 1681 PER EA 57-53-066. THIS IS A PERMAMENT REPAIR WITH NO FURTHER ACTION REQUIRED.SDR UALA2010121504580Floor Panel · corrodedMAIN CABIN AFT PRESSURE DECK AT BS 1681 AND RBL 38 IS CORRODED. MAJOR REPAIR ACCOMPLISHED: REPAIRED MAIN CABIN DECK AT 1681 IAW EA. ITEM IS CONSIDERED A PERMANENT REPAIR WITH NO FURTHER ACTION REQUIRED IAW EG.SDR DALA1100336810Seat Track · crackedMAIN CABIN SEAT TRACK CRACKED IN FWD LOWER RADIUS STA 521, LBL 24. REPAIRED IAW SRM 53-00-52, FIG 201.
Back to Pratt & Whitney PW2037