Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009082402611Controller · faultyRT PACK TRIPPED & PACK TEMP EICAS MSG WITH AFT CABIN TEMP MSG, FLIGHT DIVERTED. REPLACED COCKPIT TEMP SENSOR. REPLACED PACK TEMP CONTROLLER.SDR UALA2009082502657Actuator · unreliableRUDDER TRIM KNOB UNRESPONSIVE FOR RUDDER TRIM. INTERMITTENT, WHEN TRIMMING LT OR RT. REPLACED RUDDER TRIM ACTUATOR. INSPECTED INSTALLATION OF RUDDER TRIM ACTUATOR.SDR UALA2009082402622Cap · looseEMERGENCY EXIT LIGHTING AT ROW 6B NEEDS TO BE SECURED. SECURED END CAP.SDR UALA2009082402626Seal · leakingHIGH OIL CONSUMPTION. ACP HOC AND FOUND STARTER DRIVE SEAL LEAKING. REMOVED STARTER AND FOUND INNER CAVITY SURFACE DAMAGED AND UPPER MATING SURFACE PARTIALLY MIGRATED. STARTER MODULE REPAIRED.SDR UALA2009082402627Bolt · shearedNR 2 ENGINE DURING SCAVENGE OIL PUMP REPLACEMENT FOUND DRIVE GEARS IN MAIN GEAR BOX BEARING BOLTS SHEARED, INTERNAL DAMAGE. OIL SCAVENGE PUMP REMOVED. REPLACED NR 2 ENGINE.SDR UALA2009082502633Battery · dischargedMAINT CREW REPORTS APU BATTERY DEAD. BATTERY SWITCH MAY HAVE BEEN LEFT ON DURING BASE MAINT WITH GRD PWR APPLIED, MAIN AND APU BATT SHOW CHARGING. AFTER 30 MIN BOTH SHOW FULLY CHARGED WITH NORMAL VOLTAGE. BOTH BATT ARE COOL TO TOUCH AND CHARGERS A NORMAL WASDR UALA2009082402612Oxygen Mask · dirtyCAPS SMOKE MASK NEEDS TO BE CLEANED OR REPLACED. VISION OBSCURED. REPLACED MASK.SDR UALA2009082402617Gcu · failedLEFT ENGINE GEN CONT FAILURE, RESET OKAY. BPCU FAULTS LT GCU. REPLACED GCU. ALSO RAN ENGINE TO MAKE SURE GEN 1 OKAY.SDR UALA2009082402629Actuator · failedAFTER ENGINE STARTED GOT R SPAR VALVE EICAS FOLLOWED BY R ENG VALVE. RIGHT ENG SPOOLED DOWN. REPLACED SPAR VALVE ACTUATOR. OP CHECKED GOOD.SDR UALA2009082102580Bpcu · malfunctionedEICAS MSG L GEN OFF DISPLAYED. GEN OFF LIGHT ILLUM. OPERATED NORM AFTER RESET. CREW COMMENTS: RESET OKAY. REPLACED BPCU. SWAPPED NR 2 AND APU GCU'S PRECAUTIONARY. RAN BOTH ENGINES, BOTH ENGINES AUTO R TRANSFER FROM APU AND BACK TO APU ON ENGINE SHUT DOSDR UALA2009082102592Line · damagedENG DUCT PRESSURES SPLIT DURING CRUISE WITH ISOL VLV CLOSED & BLEED SWITCH SELECTED ON. RECORD DUCT PRESSURES. LEFT 42 PSI. RIGHT 27 PSI. REPLACED HIGH STAGE PILOT CONTROL, DUE TO HIGH PRESSURE SENSE LINE UNION CROSS THREAD REPLACEMENT. PERFORMED RUN UP SDR UALA2009082102593Shutoff Valve · failedSTART VALVE DOES NOT OPEN RT ENGINE. REPLACED START VALVE. ACP DRY MOTOR.SDR UALA2009082002555Cover · crackedEMERGENCY EXIT FLOOR LIGHTING IN AFT EXIT-GALLEY AREA IS COMING LOOSE. AN INTERIM REPAIR HAS BEEN ACP, THE LAST TWO FEET OF THE EEL COVER HAVE HAD THE EDGES ONLY TAPED TO KEEP THE EEL STRIP DOWN. CLEAR COVER IS CRACKED AND WILL NOT STAY DOWN. LIGHT STRIP HASDR UALA2009082002559Floor Panel · corrodedAFT CARGO COMPARTMENT FLOOR SIDE STRUCTURE PANEL CORRODED RT SIDE JUST AFT OF DOOR OPENING. LIFTED FLOOR PANEL AND INSPECTED AREA UNDER CORROSION AND FOUND NO EVIDENCE OF FURTHER CORROSION. SECURED FLOOR PANEL AFTER INSPECTION. CORR REMOVED AND NEW 'Z' ANGLSDR UALA2009082102579Skin · missingDAMAGE WAS FOUND AT APU INLET AREA. LOOKED AT DAMAGE, ENTIRE INNER SKIN OF APU INLET DOOR IS MISSING PROBABLY BETTER TO REPLACE INLET ASSY. REPLACED APU INLET DOOR. OPS CHECK GOOD.SDR UALA2009082102581Microphone · inoperativeCAPT O2 MASK MICROPHONE WILL NOT TEST. REPLACED MASK.SDR UALA2009082102591Oxygen Mask · leakingOXYGEN MASK DEFECTIVE AT1. (1=CAPT,2=1ST OFF,3=1ST OBS). CREW COMMENTS: CAPT O2 MASK LEAKS WHEN OUT OF STORAGE POSITION OK IN. REPLACED CAPT'S O-2 MASK.SDR UALA2009081902544Battery Pack · inoperativeOVERWING EMERGENCY EXIT LIGHTS L810, L779 AND L780 DO NOT ILLUMINATE. REPLACED BATTERY PACK AT M10568, BATTERY PACK.SDR UALA2009081902546Actuator · leakingRT WING OTBD AILERON LEAKING HYDRAULIC FLUID FROM ACTUATOR. REPLACED OTBD PCA ASSY - RT AILERON. ACCOMPLISHED INSPECTION.SDR UALA2009082002560Unknown · unknownAIRSPEED ISSUE. ACCOMPLISHED ALL TESTS (PITOT PROBE ANTI-ICING, AIRSPEED TEST, AND AIR DATA INSTRUMENT AND ADJUSTMENT TEST) AND ACCOMPLISHED A TEST FLIGHT. ALL TESTED NORMAL AND FLIGHT TEST CONFIRMED NORMAL OPERATION OF THE AIRCRAFT. THIS AIRCRAFT HAS NOT HSDR UALA2009082002548Slide · reads lowESCAPE SLIDE PRESSURE AT DOOR 3R IS LOW. SLIDE NEEDS TO BE REPLACED. REPLACED DOOR SLIDE 4R.SDR UALA2009081902539Pcu · faultedAILERONS HEAVY ON CONTROLS. REPLACED RIGHT & LEFT INBD AILERON PCA(S), LEAK AND OP CHECKED OKAY. ACCOMPLISHED RII INSPECTION OF RIGHT & LEFT INBD AILERON INSTALLATIONS. AIL FORCES STILL HIGHER THAN NORMAL. NO BINDING. MOST APPARENT BETWEEN 0 +-- 4 UNITS L OR SDR UALA2009081702518Apu · sparksAFTER PARKING AT GATE GROUND CREW INFORMED FLIGHT CREW APU STARTED THROWING SPARKS OUT THE EXHAUST. CHECKED ALL MAG PLUGS NO METAL FOUND. INSPECTED TAIL CONE, NO DEFECTS NOTED. ONE TIME FLIGHT TO HNL FOR CHANGE. REPLACED APU ASSY, LEAK AND OPS CHECKED OKAYSDR UALA2009081702514Fan · faultyF/A SMELLS SMOKE AND FUMES IN AFT GALLEY. STRONG ODOR AND RECURRING WRITEUP. F/A REPORTS ELECTRICAL BURNING ODOR IN AFT GALLEY AREA AFTER ENGINES STARTED & DURING TAXI. REPLACED 2 ELECT BALLASTS ABOVE AFT GALLEY, REPLACED 2 AIR GRILL FILTERS AND REPAIRED 2 SDR UALA2009081702517Lamp · inoperativeDOOR 4 LT EXTERIOR EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP P/N 767, OPS GOOD.SDR UALA2009081902538Light · missingEMERGENCY LIGHT STRIP AT SEAT 10B IS MISSING. REPLACED EMERGENCY LIGHT STRIP AT SEAT 10B. OPS CHECKS NORMAL.SDR UALA2009081902537Light · unsecureEMERGENCY ESCAPE PATH LIGHTING SEAT 34C TORN LOOSE FROM PLASTIC HOUSING. FOUND BLACK END CAP ON THE END OF FLOOR EMERGENCY LIGHT STRIP OFF, TAPED DOWN AS AN INTERM REPAIR WITH TAPE. SECURED CAP, LIGHTS CHECK NORMAL.SDR UALA2009081702510Light · inoperativeEXTERIOR LIGHT AT DOOR 1 RT INOP. RELAMPED, OPS CHECK GOOD.SDR UALA2009081802534Bolt · shearedNR 4 LEADING EDGE SLAT OTBD AUX TRACK GUIDE ROLLER BOLT SHEARED. REPLACED ROLLER AND BOLT AND ALL RELATED HARDWARE. INSPECTED AFT BOLT FOR NR 4 AUX TRACK. LEADING EDGE SLAT PANEL 521CB.SDR UALA2009081802535Exciter · faultedLEFT ENGINE NR 1 IGNITION SYSTEM INOPERATIVE. AUDIBLE IGNITION CHECKED GOOD. REPLACED NR 1 IGN PLUG PRECAUTIONARY. STARTED ENGINE 4X AND IGNITION TIMES VARY FROM 3-10 SECS EACH TIME BUT LIT OFF OKAY. IF PROBLEM PERSIST, MAY WANT TO SUSPECT POSSIBLE FUEL STSDR UALA2009081702507Fan · malfunctionedAFT GALLEY AREA STRONG ODOR OF BURNING INSULATION WIRES (ELECTRICAL SMELL), NO FIRE. CREW PULLED ALL C/BS IN AFT GALLEY. REPORTED BY CREW AFTER PARKED AT THE GATE. RAMP NOTICED THE ODOR IN AFT PIT AND WHEN OPENED WATER SVC PANEL STRONG ODOR WAS THERE ALSO. SDR UALA2009081702509Actuator · leakingRIGHT WING UNDER AND NEAR RIGHT AILERON IS WET WITH HYDRAULIC FLUID. REPLACED RT WING INBOARD AILERON ACTUATOR. VERIFICATION FLIGHT CONFIRMS NORMAL OPERATION.SDR UALA2009081802533Regulator · faultyL ENG BLEED WON'T CLOSE AFTER ENG START. REPLACED PRSOV REGULATOR, L ENG BLEED OFF LIGHT ILLUMINATED WITH PRSOV IN CLOSED POSITION.SDR UALA2009081702520Lavatory · overflowLAV OVERFLOW, FLIGHT DIVERTED. SERVICED ALL LAVS.SDR UALA2009081702524O-Ring · leakingLOW BOTTLE PRESSURE. LEAKING AT BURST DISK O-RING. REMOVED & REPLACED O-RING.SDR C8GA20090178Eec · malfunctionedDURING CRUISE OPERATION AT FL390 THE LT ENG SHUTDOWN ON ITS OWN. THE ACFT DECLARED AN EMERGENCY AND DIVERTED WHERE IT LANDED WITHOUT INCIDENT. POST FLIGHT INSP WAS PERFORMED, INSPECTED CONNECTOR AT RVA D5536, TLR D4734, FCU 4860, SVA 4868, EEC D502, D4554, NO SDR UALA2009081802530Gcu · faultyEICAS MSG L GEN OFF DISPLAYED. GEN OFF LIGHT ILLUMINATED. OPERATED NORMAL AFTER RESET. CREW COMMENTS: REPEAT GRIPE. LEFT GEN CONTROL OFF LT ILLUMINATED ON CLIMB-OUT. RESET NORMAL. LEFT GEN TRIPPED SECOND TIME. APU STARTED FL370. BPCU SHOWED "OPEN PHASESDR UALA2009081302492Wire · damagedEXTERNAL POWER PLUG CAUGHT FIRE AT POWER RECEPTACLE. REPLACED 2 EA INTERCOSTAL, WORKING PAN INSTALLATION THEN WIRING CONNECTS. PAN INSTALLED & SOLD. WIRING ROUTED, E&E RESTORED. POWER IS BACK ON ACFT & WRKG MISC OPS. REVERSER SLEEVES SWAPPED BET 1 & 2 ENSDR UALA2009081402494Lanyard · frayedTHE 2R MED EVAC SLIDE GIRT BAR LANYARD FRAYED. ACP ON WU K6903D, REPLACED SLIDE.SDR UALA2009081302463Carbon Seal · leakingNR 2 ENG HIGH OIL CONSUMPTION EXCEEDS LIMIT. ACCOMPLISHED RUN AT 80 PERCENT FOUND OIL LEAK FROM STARTER DRAIN 60 DROPS A MIN. REPLACED NR 2 ENG STARTER DRIVE CARBON SEAL. RERAN ENG, NO LEAKS. SECURED FAN COWLS.SDR UALA2009081402502Cap · damagedEEL LIGHT AT SEAT 34A DAMAGED. REPLACED EEL LIGHT END CAP. TESTED EEL LIGHT NORMAL.SDR UALA2009081302469Light · damagedEMERGENCY LIGHT AT SEAT 34A DAMAGED. REPAIRED EMERGENCY LIGHT SYSTEM AT SEAT 34A. EMERGENCY LIGHT SYSTEM CHECK OKAY.SDR UALA2009081402501Fire Loop · inoperativeLEFT ENGINE LOOP 1 FIRE DETECTION INOPERATIVE. REPLACED NR 1 LOOP (UPPER RESPONDER). TESTED OK BUT FOUND LOOP RUBBING AGAINST SUPPORT TUBE. AFTER INSTALLATION CHECKS OK.SDR UALA2009081302464Power Supply · damagedEEL STRIP DAMAGED BETWEEN ROWS 12 AND 14. REPLACED POWER SUPPLY AND JUMPER CABLE FOR SEAT ROWS 9 THROUGH 13. OP CHECKS OKAY.SDR UALA2009081302470Frame · corrodedFOUND CORROSION ON FRAME AT STA 1680 BETWEEN STR 29 RT AND STR 30. MAJOR REPAIR ACCOMPLISHED: PERFORMED A GVI OF FUSELAGE STRUCTURE BETWEEN BS 1664-1700 AND STR 26L-26R. FOUND CORROSION ON FRAME, BS 1681 AND SHEAR TIE BETWEEN ST R-27L-28L. REMOVED FRAME ANSDR UALA2009081002416Sensor · inoperativeRT PACK OUTPUT TEMPS ARE ERRATIC IN MANUAL MODE. IN N POS: 118 DEGREES, IN W POS: 62 DEGREES. REPLACED STBY PACK OUT TEMP SENSOR, NO HELP. STBY MODE INOP. OK AUTO. REPLACED TS 199 RT PACK TEMP SENSOR. SYSTEM OPS CHECKS NORMAL. ACCOMPLISHED BITE OF L-H PTSDR UALA2009081002443Idg · leakingFLUID DRIPPING FROM RT ENG IDLE RUN ENG FOUND FLUID LEAKING FROM NR 1 DRAIN TUBE THERMAL RELIEF VENT. IDG WAS NOT OVER SERVICED AND NO FUEL PRESENT. REPLACED NR 2 IDG.SDR UALA2009081002445Cover · damagedEMERGENCY LIGHT LENS COVER DAMAGED 9C TO 13C. REPLACED COVER.SDR UALA2009081102446Compressor · leakingSMOKE IN THE COCKPIT AND CABIN, RTFL. AFTER TAKEOFF, SMOKE IN THE COCKPIT AND AROUND CABIN ROWS 15 THRU 19, OILY ODOR, TURNED OFF RT RECIRC FAN, SMOKE CLEARED AFTER ABOUT 5 MINUTES. INOP NR 1 PACK, DUE TO SMOKE IN CABIN. FOUND OIL LEAKING FROM BETWEEN NR 2 ASDR UALA2009081102449Squib · no testTEST 1 FAILED FOR RT OVERWING SLIDE SQUIB. CYCLE RIGHT GROUND ENABLE HANDLE ON P79 AND BOTH SYSTEM, SQUIB TESTED OK.
Back to Pratt & Whitney PW2037