Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2007UALA00812Skin · corrodedFWD CARGO LEFT SIDE WALL LAV SERVICE PORT UPPER SKIN CORRODED AROUND DUCT AT STA 705-711, STR 19L-21. MAJOR REPAIR ACCOMPLISHED. REPLACED DOUBLER.SDR 2007UALA00831Warning System · malfunctionedEVAC ALARM HAS ACTIVATED AT ALL STATIONS ALL BY ITSELF. PRESSED HORN SHUTOFF, NO HELP. [SUP 06-14-07] TESTED EVAC SYSTEM PER UA ENGINEERING SPECIFICATIONS. SYSTEM TESTED GOOD. NO DEFECTS NOTED. UNABLE TO ESTABLISH ANY CAUSE FOR THIS IRREGULARITY EVENT.SDR 2007UALA00779Unknown · vibrationFLIGHT DIVERTED DUE TO AN AIRFRAME VIBRATION. UNIDENTIFIED RUMBLE- VIBRATION VERY STRONG AFT GALLEY MIDDLE FLOOR. FOUND WATER FILL VALVE OPEN, CLOSED VALVE. SERVICE PANEL HAD ICE CHUNKS BANGING AROUND INSIDE CAUSING NOISE. CLEANED OUT PANEL AND CLOSED. REMOVSDR 2007UALA00789Door Frame · crackedTHE 2L MED UPPER HINGE FRAME CUTOUT LWR RADIUS CRACKED. MAJOR REPAIR ACCOMPLISHED: COMPLETED A DOUBLER REPAIR ACCORDING TO A BOEING APPROVED REPAIR.SDR 2007UALA00767Light · faultyEEL LIGHT BAR IN FRONT OF THE AFT LAV IS INOPERATIVE. REPAIRED AFT LAV LIGHT BAR.SDR 2007UALA00774Bulkhead · crackedNR 2 ENGINE STRUT BULKHEAD CRACKED AT MAIN FUEL LINE CLAMP BLOCK CONNECTION AT NAC STA 102.1. MAJOR REPAIR ACCOMPLISHED: REMOVED 3 ANGLES, 2 FILLER, 2 SEALS AND VBAND. REMOVED WEB. INSTALLED NEW WEB, ANGLES AND FILLERS. INSTALLED VBAND RETAINER AND 2 SEALS.SDR 2007UALA00759Girt Bar · out of adjustDOOR 1L WILL NOT ARM. ADJUSTED GIRT BAR FLOOR LOCK, DOOR OPS CHECK OK.SDR 2007UALA00740Skin · dentedDENT AFT PIT DOOR 16 INCHES AFT OF FWD EDGE 27 INCHES DOWN FROM TOP EDGE, 1.250 INCHES DIA .750 IN WIDTH AND .031 DEPTH. MAJOR REPAIR ACCOMPLISHED: CUTOUT DAMAGED AREA. FABRICATED & INSTALLED DOUBLER & FILLER REPAIR.SDR 2007UALA00742Torque Tube · damagedL-1 DOOR LOWER GIRT BAR LINKAGE TORQUE TUBE IS GOUGED AND CORRODED. [SUP 05-22-07] L-1 DOOR LOWER GIRT BAR LINKAGE TORQUE TUBE IS GOUGED AND CORRODED. REPLACED TORQUE TUBE DURING DOOR OVERHAULS.SDR 2007UALA00743Floorbeam · corrodedRIGHT FWD MAIN CABIN FLOOR STRUCTURE, FLOORBEAM UPPER CHORD ON UPPER AND LOWER SURFACES CORRODED AROUND FASTENER HOLES IN MULTIPLE PLACES, BS 365.25, RBL 0 TO RBL 64. MAJOR REPAIR ACCOMPLISHED: RMV'D CORROSION. FABRICATED & INSTALLED REPAIR ANGLE & STRAP.SDR 2007UALA00746Lamp · inoperativeDOOR 3R SLIDE ARMED LIGHT INOPERATIVE. [SUP 05-29-07] RELAMPED. OP CHECKED NORMALLY.SDR 2007UALA00747Bottle · no test2R EMERGENCY ESCAPE SLIDE FAILS TEST. [SUP 05-22-07] REMOVED AND REPLACED BOTTLE ASSY. OPERATIONAL TEST OK.SDR ASMF200703004Idg · leakingAIRCRAFT REJECTED TAKEOFF AT 80 KNOTS DUE TO (L GEN) LIGHT TURNED ON IN EICAS. DURING MAINTENANCE CHECK, THE LT IDG WAS DETECTED WITH LOW OIL LEVEL. FAILURE WAS DEFERRED BY MEL 24-00-1, THE LANDING GEAR AND BRAKES WERE CHECKED BY CONDITION, BEING ALL CORRECT. SDR 2007UALA00730Fan · odorIN DESCENT PASSING FL370 CREW DETECTED AN ELECTRICAL BURNING ODOR IN THE COCKPIT WHICH QUICKLY DISSIPATED. [SUP 05-18-07] ACCOMPLISHED INSPECTION BEHIND COCKPIT CB PANELS AND E & E COMP. CREW COMMENT ODOR DISSIPATED BY TURNING OFF RIGHT RECIRCULATION FAN. ISDR 2007UALA00741Girt Bar · malfunctionedUNABLE TO DISARM SLIDE PACK WITH SAFETY PIN DOOR 4R. [SUP 05-18-07] FOUND DOOR 4R GIRT BAR AFT FOOT MISSING AND SLIDE NOT SERVICEABLE WHILE WORKING INBOUND GRIPE. REPLACED SLIDE AND GIRT BAR FOOT. GIRT BAR IS MOVING WHEN TRYING TO ARM. UNABLE TO DISARM SLIDSDR 2007UALA00719Engine · inoperativeDIVERTED FLIGHT DUE TO LOSS OF NR 1 ENGINE. LEFT ENGINE FAILED INFLT FL330 N2 ZERO OIL PRESSURE. ENGINE WINDMILLING INSPECTION. CREW REPORTED ENGINE WINDMILLED FOR 40 MINS WITH ZERO OIL QTY INDICATED. CONDUCTED OIL FILTER AND MAG PLUGS INSP AND NO CONTAMSDR AALA20070464Turbine Blades · failedLAS INFLIGHT - DURING CLIMB CREW EXPERIENCED SEVERAL RIGHT ENGINE COMPRESSOR STALLS AT ROTATION AND LOUD BANGS. ENGINE GAS TEMPERATURE TO 664. SHUTDOWN ENGINE AND LANDED LAS WITHOUT INCIDENT. REPLACED NUMBER TWO ENGINE ON 12 MARCH 2007 DUE TO TURBINE BLADE SDR 2007UALA00731Wire · burnedFOUND BURNED WIRE BUNDLES & SHIELDED WIRES DAMAGED ALONG WITH INTERCOSTAL AND FLOOR STRUCT AT STA 680 FWD PIT CEILING. FOUND WIRES W4104-0082-20 & W4104-0090-20 SHORTED TO GROUND. RIGHT RECIRC FAN CIRCUIT BREAKER C337 ON P37 PANEL TRIPPED. PUSHING C/B IN ACSDR 2007UALA00733Connector · dirtyEMERGENCY ESCAPE SQUIB TEST INOP, RIGHT SQUIB TEST POSN TWO. [SUP 05-22-07] CLEANED CONNECTOR. OPS CHECKED NORMAL.SDR DL757070192Powerplant · overservicedON TAKEOFF, SMOKE DETECTED IN CABIN FUMES IN COCKPIT CREW DONNED MASKS LAVATORY SMOKE DETECTORS HEARD A/C LANDED AND RETURNED TO GATE UNDER POWER OIL ODOR DETECTED IN CABIN BY MAINTENANCE WHEN ENTERED AFTER PAX DOOR OPENED. FOUND NR 2 ENG OIL OVERSERVICED ANDSDR 2007UALA00712Bottle · reads lowTWO EACH CABIN LIFE RAFTS, CYLINDER PRESSURE GAUGE NEEDLES ARE IN RED BAND (LOW PRESSURE). [SUP 05-18-07] LOW BOTTLE PRESSURE ATTRIBUTED TO A LEAKING GAUGE O-RING, WHICH APPARENTLY FAILED TO SEAL. FILL VALVE WAS FOUND LOOSE. TIGHTENED VALVE AND RETESTED.SDR 2007UALA00713Skin · dentedDENT IN FUSELAGE LEFT SIDE JUST FWD OF LAV SERVICE PANEL. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED & FABRICATED & INSTALLED REPAIR DOUBLER.SDR 2007UALA00718Starter · failedDURING RT ENG START, NO N2, NO N1, RAMP REPORTED SPARKS FROM RIGHT ENGINE. [SUP 05-18-07] REPLACED STARTER DUE TO LOW OIL. ALSO REPLACED STARTER VALVE DUE TO FOD FROM STARTER FAILURE. OP CHECKS OK.SDR 2007UALA00734Girt Bar · lack of lubeTHE 3L DOOR WILL NOT DISARM. [SUP 05-18-07] LUBED GIRT BAR, OP'S CHECKED NORMAL ON GROUND. FOUND WATER UNDER GIRT BAR AREA INDICATING POSSIBLE ICE BUILD-UP IN THE AREA.SDR 2007UALA00698Skin · crackedNR 2 PYLON INBOARD SIDE SKIN CRACKED AT FWD HOLE. MAJOR REPAIR ACCOMPLISHED: REPAIRED SIDE SKIN WITH 3 EACH REPAIR DOUBLERS.SDR 2007UALA00699Light · no testBOTTLE 2 DISCHARGE LIGHT INOP, WON`T TEST. RELACED LIGHT.SDR 2007UALA00676Duct · looseRTFL DUE TO SIGNIFICANT VIBRATION IN LEFT ENGINE AFTER TAKEOFF. COULD NOT ADVANCE POWER W/O VIBRATION INCREASING. 3RD STAGE LPT BLADE FRACTURED. THE 3RD STAGE LPT BLADES AND VANES WERE SULFIDED. DURING DISASSEMBLY A BOLT FOR THE OUTER DUCT WAS FOUND FRACTSDR 2007UALA00678Compressor · stalledRTFL DUE TO NR 2 ENGINE COMPRESSOR STALLS. [SUP 05-18-07] BOROSCOPE NR 2 ENG SERIAL NR 727193, FOUND SEVERE DAMAGES ON COMPRESSOR STAGES 16 & 17 THROUGH AP8. FOUND RT ENGINE BLADE 1 & 2 GOUGES IN LEFT EDGES. BLADES 1 AND 2 OK. REPLACEMENT OF NR 2 ENG NR 4SDR 2007UALA00685Unknown · unknownON CLIMBOUT, RECEIVED EICAS STATUS MSG: NOSE A-G DISAGREE. [SUP 05-18-07] CREW SAID, NOSE A-G DISAGREE DISPLAYED DURING CLIMB & REMAIN DISPLAYED, NO OTHER DISCREPANCY NOTED. REPLACED LT NOSE GEAR NOT COMPRESSED SENSORSSDR 2007UALA00687Skin · crackedNR 2 PYLON OUTBOARD SKIN IS CRACKED AT FWD HOLE. [SUP 4-24-07] MAJOR REPAIR ACCOMPLISHED. HFEC INSP AT END OF CRACK. INSTALLLED 301 HALF 0.050" DOUBLERS AS A UA APPROVED REPAIR.SDR 2007UALA00671Lamp · inoperativeEXTERIOR EMERGENCY LIGHT INOP AFT RIGHT OVERWING. [SUP 5-1-07] RELAMPED.SDR 2007UALA00686Unknown · unknownIN CLIMB CENTER A-P DISCONNECTED FOUND C/B E21 POPPED. FLIGHT CONTROL COMPUTER SERVO CENTER. [SUP 05-18-07] FOUND CENTER FCC WITH INTERNAL FAILURE FOR OUTPUT TO SOCKET 18 POWER TO CENTER LATERAL CONTROL SERVO . REPLACED A-P CENTER LATERAL CONTROL SERVO AFTSDR 2007UALA00645Unknown · odorNOTICED BURNING PLASTIC ODOR ON DESCENT OUT OF 240. TURNING OFF RIGHT RECIRC FAN NO CHANGE. PER CREW, ODOR IN FLT DECK AREA, WENT AWAY AT APPROX 8000 FT. [SUP 05-18-07] CHECKED MEC FOR ELEC MODULE FAULTS OR ODOR IN AREA AND NONE FOUND. CHECKED WINDOW HEAT SDR 2007UALA00634Wire · faultyA-ZONE FLOOR EEL INOP FROM SEAT 3 TO SEAT 6. REPAIRED CABLE. OPS CHECKED GOOD.SDR 2007UALA00644Light · inoperativeEEL LIGHT BAR AT THE MID LAV IS INOPERATIVE. REPAIRED EEL LIGHT BAR AT MID LAV. OPS CHECKS GOOD.SDR 2007UALA00655Contact · out of alignmentEMERGENCY SLIDE LIGHT INOP AT DOOR 1R. [SUP 4-17-07] FOUND CENTER CONTACT POPPED OUT OF LIGHT ASSEMBLY. REINSTALLED CENTER CONTACT OPS NORMAL.SDR 2007UALA00661Apu · shutdownAPU AUTO SHUTDOWN AFTER APPROX 15-20 MINS OF OPERATION. ALL CHIP DETECTORS ARE OKAY AND NOTED OIL SYSTEM EXTREMELY HOT. [5-1-07] HISTORY SHOWS COOLING FAN AND OIL COOLER RECENTLY REPLACED. REPLACED APU.SDR 2007UALA00630Bottle · reads lowSLIDE AT DOOR 1L BOTTLE PRESSURE LOW. [SUP 05-08-07] WATER VALVE TESTED FOR LEAKS. FOUND THE SEAL WAS BROKEN INSIDE THE GAUGE AND BECAME NON-SERVICEABLE. REMOVED AND REPLACED GAUGE.SDR 2007UALA00635Feeder Cable · damagedEEL FEEDER AT ROW 28 DAMAGED. REPLACED EEL LEAD IN AND OPS CHECK GOOD.SDR 2007UALA00618Hinge · crackedDOOR 2R UPPER HINGE CUTOUT IS CRACKED. MAJOR REPAIR ACCOMPLISHED: TRIMMED OUT DAMAGE & ACCMP'D INSURANCE CUT. NO CRACKS FOUND. FABRICATED & INSTALLED REPAIR DOUBLER.SDR 2007UALA00625Lock · out of adjustRIGHT OVERWING SLIDE CARRIER LOCK RELEASE TRIGGER IS OUT OF ADJUSTMENT, DOOR WILL NOT LATCH. [SUP 05-18-07] TROUBLESHOT AND FOUND INNER LOCK TUBE WAS NOT CLOCKED PROPERLY WITH LOCK BASE RETAINER PREVENTING CONTACT WITH BEARING. ADJUSTED LOCK BASE RETAINER ASDR 2007UALA00627Cylinder · corrodedRT OUTER CYLINDER HAS CORROSION. [SUP 05-18-07] RT OUTER CYLINDER CORROSION HAS BEEN REMOVED. SHOP CONTINUES TO BLEND FURTHER CRACK INDICATIONS. INSTALLED RT MLG SHOCK STRUT INNER CYLINDER AND RT MLG SHOCK STRUT. FOUND RUSTY WATER AND SLUDGE ABOVE SCRAPER.SDR 2007UALA00609Connector · looseEMERGENCY EXIT LIGHT AT ROW 13 INOPERATIVE. [SUP 4-17-07] TROUBLESHOT AND FOUND CONNECTOR D07274 LOOSE, RECONNECTED AND PERFORMED OPS CHECK GOOD.SDR 2007UALA00610Light · inoperativeAMBER UNLOCK LIGHT ON RAT SWITCH INOPERATIVE. [SUP 05-18-07] RELAMPED SWITCH AND OPS CHECK GOOD. THIS DISCREPANCY IS ATTRIBUTED TO A FUSED LAMP.SDR 2007UALA00613Light · inoperativeFIRE-OVERHEAT TEST PANEL SYSTEM FAIL LIGHT NEEDS TO BE RELAMPED. [SUP 05-18-07] REPLACED KOREY LIGHT SWITCH FIRST WITH INCANDESCENT LIGHT SWITCH, DETERMINED THAT BASE ASSEMBLY NEEDS TO BE REPLACED. REPLACED SW MODULE AND TESTS OK. LATER INSTALLED WITH LSDR 2007UALA00614Light · inoperativeDOOR 2R SLIDE ARMED LIGHT INOPERATIVE. [SUP 05-18-07] REPLACED LAMPS. THIS WAS A CASE OF A FUSED LAMP.SDR 2007UALA00591Frame · gougedFUSELAGE FRAME HAS DEEP GOUGES STA 1720 BETWEEN STR 29L TO JUST O/B OF STR 29R.SDR 2007UALA00604Light · brokenEEL LIGHT STRIP BROKEN AT ROW 13. [SUP 4-17-07] SPLICED POWER STRIP AND RESECURED, LIGHT OPS NORMAL.SDR 2007UALA00605Connector · damagedEMERGENCY STRIP LIGHTS ROW 23 INOPERATIVE. [SUP 4-17-07] TROUBLESHOT EMERGENCY STRIP AT SEAT ROW 23. FOUND WIRE PULLED FROM CONNECTOR, REPAIRED CONNECTORSDR 2007UALA00606Gate · corrodedL-2 DOOR LOWER GATE CORRODED ON OUTER LOWER FLANGE SURFACES. [SUP 05-08-07] REMOVED CORROSION AND FOUND TO BE WITHIN SRM LIMITS. ORIGINAL MATERIAL THICKNESS OF 0.140" IS NOW DOWN TO 0.136" AFTER CORROSION REMOVAL. NO COMPONENTS NEEDED TO BE REPLACED.
Back to Pratt & Whitney PW2037