Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2005UALA00798Slide · leakingTUBE ASSY FAILED AIR RETENTION TEST DUE TO EXCESSIVE POROSITY LEAKING THROUGH TUBE FABRIC NOTED ON VARIOUS LOCATIONS. DURING COMPONENT SHOP MAINTENANCE SLIDE FAILED AIR RETENTION TEST DUE TO FABRIC POROSITY. POROSITY WAS BEYOND CMM LIMITS. SLIDE WAS RETURNED SDR 2005UALA00746Engine · contaminatedRETURNED TO FIELD UNDER AMBER ALERT DUE TO FUMES IN THE COCKPIT. ODOR DISSAPATED DURING RETURN TO GATE. THE DETERGENT WASH OF THE ENGINES IS THE SORCE OF THE ODOR. PER MM 72-05-99 PAGE 701, ENGINE NEEDS HIGH POWER RUN AFTER WASH TO REMOVE ANY DETERGENT RESIDUSDR 2005UALA00741Pdu · vibrationRETURNED TO FIELD DUE TO AIRCRAFT VIBRATION. TE FLAP PDU DID NOT FUNCTION PROPERLY. REPLACED SUBJECT PDU.SDR 2005UALA00723Battery · dischargedEXTERIOR EMERGENCY SLIDE LIGHT IS INOP. REPLACE EEL BATTERY CHARGER AT DOOR 1L.SDR DL75K050403Engine · making metalLEFT ENGINE FAILED ON TAKEOFF ROLL, ABORTED T/O. REPLACED ENGINE.SDR 2005UALA00705Warning Light · illuminatedRETURNED TO FIELD DUE TO THE LEFT GENERATOR DRIVE LIGHT. SHOP FINDINGS INDICATED THAT NO FAULT WAS FOUND. THE IDG OIL PRESSURE SWITCH WAS REPLACED PRECAUTIONARY.SDR 2005UALA00706Lamp · burned outEMERGENCY AISLE ILLUMINATION LIGHT INOP AT ROW 5. REPLACED LAMP.SDR 2005UALA00677Keelbeam · corrodedKEEL BEAM CORROSION. EXT CHORD BS 1180 TO 1176, APPROXIMATELY 6 LBL TO 6 RBL. REMOVE CORROSION AND CK LIMIT PER SRM 53-30-12. ORIGINAL THICKNESS=.130", AFTER REPAIR THI CKNESS=.124", LOSS OF MATERIAL IS WITHIN LIMIT PER SRM 53-30-12SDR 2005UALA00670Switch · malfunctionedLANDED SFO UNDER AMBER ALERT DUE TO LOSS OF GENERATOR AND APU NO-START. GENERATOR DELTA-P SWITCH REPLACED. OPS CHECK GOOD. NO METAL FOUND ON CHIP DET. IN ADDITION TO REPLACEMENT OF GEN DELTA P SWITCH, CH ITEM INCLUDED TO REPLACE APU GENERATOR DUE TO MULTIPSDR 2005UALA00799Slide · leakingTUBE ASSY FAILED AIR RETENTION TEST DUE TO EXCESSIVE POROSITY LEAKING THROUGH TUBE FABRIC NOTED ON VARIOUS LOCATIONS. DURING COMPONENT SHOP MAINTENANCE SLIDE FAILED AIR RETENTION TEST DUE TO FABRIC POROSITY. POROSITY WAS BEYOND CMM LIMITS. SLIDE WAS RETURNEDSDR DL757050373Engine · making metalFL380 LEVEL FLT .79 MACH RT ENGINE CHUGGED AND RT OIL TEMP ROSE TO 166 THROTTLED BACK OIL TEMP RECOVERED EICAS MSG RT OIL FILTER APPROX 5 MINUTES LATER ENGINE CONTINUALLY CHUGGED SHUT IT DOWN. NO METAL FOUND IN TAILPIPE. ALL CHIP DETECTORS HAVE METAL STATUS SDR 2005UALA00689Battery · inoperativeEMERGENCY EXIT LIGHTS AT DOOR 1R INOPERATIVE. REPLACED BATTERY PACK AT M730. REPLACED BATTERY PACK AT M730.SDR 2005UALA00661Shear Tie · damagedSHEAR TIES AT FUSELAGE STA 600 STR 16L-18L HAS OVERSIZE FASTENER HOLES. FABRICATE AND REPLACE SHEAR TIES PER TIMCO EA REO-G10727 AND MM 51-40-02.SDR 2005UALA00662Frame · dentedFRAME 600 IS DENTED AT STRINGER 23L. TRIM OUT DAMAGE, ACP HEFC INSP, NO CRACK NOTED. REPAIRED PER GSO EA G10674 REV B.SDR 2005UALA00664Skin · dentedAPPROX 8 INCH FWD OF C2 DOOR CUTOUT NEAR UPPER CORNER, AIRCRAFT SKIN HAS LARGE DENT. CUT OUT DAMAGE AREA, ACP NDT HFEC INSPECTION, NO CRACK FOUND. FABRICATE AND INSTALL DOUBLER REPAIR PER TIMCO EA REO-G10749, REV A, UA-EVA-50463.SDR 2005UALA00665Shear Tie · damagedSHEAR TIE AT FS 580, STR 14L-15L HAS OVERSIZE FASTENER HOLE. MANUFACTURED SHEAR TIE PER TIMCO EA REO-G10727, REV 1R, UA-EVA-50456.SDR 2005UALA00669Coffeemaker · shortedCOFFEEMAKER DELIVERED SHOCK TO FLIGHT ATTENDANT IN REAR GALLEY. UNIT TESTED ONLY AFTER BURST HEATER WAS REPLACED. CAN ONLY SPECULATE BURST HEATER CARTRIDGE IN WATER MAY HAVE BEEN SOURCE OF STRAY CURRENT. UNIT BONDING OK.SDR 2005UALA00663Packing · leakingRETURNED TO FIELD DUE TO INDICATION OF LOSS OF HYDRAULIC FLUID. HYDRAULIC FLOW LIMITER PACKINGS WERE LEAKING AT THE UNIONS, THE PACKINGS WERE REPLACED. THE LEFT HYDRAULIC SYSTEM WAS SERVICED AND LEAK CHECKED OK. AIRCRAFT WAS RETURNED TO SERVICE.SDR 2005UALA00657Apu · inoperativeRETURNED TO THE FIELD AT SFO AFTER THE APU WOULD NOT START AT TOP OF CLIMB. APU WAS REMOVED FROM AIRCRAFT AND TESTED IN APU TEST CELL. NO FAULT FOUND WITH APU S/N 61832. PASSED ALL TEST AND RETURNED TO SERVICE. AFTER APU REPLACEMENT, MECHANIC FOUND APU BATTSDR 2005UALA00659Connector · brokenEEL TEST SWITCH ABOVE 2L DOOR BROKEN CONNECTOR. BROKEN CONNECTOR ON EEL TEST SWITCH. REPLACED SWITCH.SDR 2005UALA00660Power Supply · dischargedEMERGENCY LIGHTS INOP AT FOLLOWING LOCATIONS: AISLE LIGHT IN BULLNOSE AT ROW 25, CEILING EXIT SIGN AT ROW 16 AND EXTERIOR SLIDE LIGHT ON AFT CARGO DOOR. POWER SUPPLIES LOW CHARGE, REPLACED.SDR 2005UALA00648Skin · damagedFUSELAGE STATION 1598, STR 19R HAS DAMAGE. SUPPLEMENTAL DATA UPDATE, REMOVED AND REPLACE REPAIRED DOUBLER AT FUSE STA 1598, STR 19R PER TIMCO EA REO-G10703 AND UA-EVA-50446.SDR 2005UALA00649Skin · damagedFUSELAGE STATION 1595, STR 19R IS DAMAGED. THE REPAIR WAS MODIFIED PER EVA IND-3213A TO REPLACE RIVETS WITH HILOCKS ON THE STRINGER ROW. PERMANENT REPAIR PER SRM 53-00-01 PG 206-208.SDR 2005UALA00650Wire · damagedEEL JUMPER AND FEEDER DAMAGED AT STA 895. DAMAGED EEL CABLE WAS REPLACEDSDR ASMF200507006Combust Chamber · damagedDURING LT ENGINE BOROSCOPIC INSPECTION, DETECTED COMBUSTION CHAMBER DAMAGED WITH 2 AXIAL CRACKS INTERSECTED WITH CIRCUMFERENTIAL CRACK OUT LIMITS. LT ENGINE REPLACED AND TESTED IAW MM 71-00-02 AND MM 71-00-00, RESPECTIVELY. ALL CORRECT.SDR 2005UALA00642Radar · failedWEATHER RADAR FAILED JUST AFTER TAKEOFF. FLIGHT DIVERTED DUE TO THUNDERSTORMS. MAINTENANCE REPLACED THE RADAR ANTENNA ASSY (P/N 2041444-0401). THE COMPONENT SHOP TESTING DID NOT REVEAL ANY FAILURES, HOWEVER THE AZIMUTH GEAR ASSY WAS FOUND WITH WATER CONTAMISDR 2005UALA00790Light · inoperativeEEL AT 1-R DOOR INTERIOR AND EXTERIOR INOP. REPLACED EXIT LIGHT.SDR 2005UALA00623Wire · tornEEL FEEDER MID CABIN BY L2 DOOR IS TORN. REPLACED EEL STRIP.SDR 2005UALA00613Skin · dentedEXTERNAL FUSELAGE SKIN DENTED 1 INCH BELOW FLOOR LEVEL AND 10 INCHES FORWARD OF 2 LT MED. MAJOR REPAIR WAS ACCOMPLISHED PER UA-EVA-50430.SDR 2005UALA00606Wire · damagedRETURNED TO FIELD DUE TO AIR/GROUND SENSOR FAILURE, MANUAL GEAR RETRACTION. FOUND TRIPPED SYS 2 AIR GROUND CB AND CHAFED WIRE IN P37 PANEL (W1270-5852-22).REPLACED CIRCUIT BREAKER AND ACCOMPLISHED REPAIR OF DAMAGED WIRE.SDR 2005UALA00655Fan · failedSTRONG ODOR IN REAR OF CABIN ON TAXI OUT. RIGHT RECIRC FAN FAILED. DEFERRED PER MEL, THEN REPLACED FAN. OPS CHECK OK. RETURNED AIRCRAFT TO SERVICE.SDR 2005UALA00596Smoke · detectedRETURNED TO THE FIELD DUE TO SMOKE IN THE COCKPIT. CAUSE OF INCIDENT WAS A FAILED THRUST DISK & BEARING IN LT ACM. COMPONENT FINDINGS WERE A FAILED THRUST DISK & A FAILED BEARING WHICH ALSO DAMAGED TURBINE & COMPRESSOR SECTIONS. THRUST DISK, BEARING TURBINESDR 2005UALA00646Skin · lightning strikeTOP OF FUSELAGE HAS 2 LIGHTNING STRIKES. REMOVED DAMAGE AND MANUFACTURED REPAIR REF SRM 53-00-01.SDR ASMF200506021Starter · failedACFT RETURNED TO PLATFORM. DURING RT ENGINE STARTING, N2 INDICATION REACHED 23 PERCENT AND WENT TO ZERO. PNEUMATIC STARTER AND PNEUMATIC STARTER VALVE REPLACED IAW MM 80-11-01 / -02, TESTED CORRECT.SDR 2005UALA00532Engine · malfunctionedDIVERTED DUE TO RT ENGINE OIL QTY AND PRESSURE IND. RT ENGINE SHUTDOWN. IN CRUISE LOSS OIL QTY & PRESSURE. CREW SHUTDOWN ENGINE. UPON LANDING FOUND EXHAUST OIL WETTED. ENGINE REMOVED. UPON DISASSEMBLY OF ENGINE FOUND NR 5 BEARING BAY HEAVILY COKED & NR 5 SCASDR 2005UALA00533Frame · dentedAFT PIT LT SIDE STA 1540 HAS 3 EACH DENTS BETWEEN STR 25L AND 26L, ON INBOARD FLANGE. REPAIRED FRAME WITH FABRICATED NEW PRODUCTION SPLICE ANGLE PER TIMCO REO (EVA) G10550, REV. B.SDR 2005UALA00523Floorbeam · corrodedFLOORBEAM CORRODED AT STA 367, RBL 56 UPPER SURFACE. REPLACED SUPPORT 141N5161- 52 PER SRM 51-40-02.SDR 2005UALA00524Floorbeam · corrodedRIGHT SIDE BS 1640 FLOORBEAM, RBL 0 - RBL 60, TOP CAP IS CORRODED. DAMAGE DUE TO CORROSION IN TYPICAL WET AREA. REMOVED CORRODED REPAIR STRAP AND INSTALLED NEW REPAIR STRAP.SDR 2005UALA00525Terminal Block · crackedRETURNED TO FIELD DUE TO MULTIPLE CB'S TRIPPED PRIOR TO ROTATION, MULTIPLE EICAS MSG'S. LEFT GENERATOR CONTACTOR, C901, PHASE -B- TERMINAL LUG WAS FOUND CRACKED / BROKEN, PROMOTING ELECTRICAL PROBLEMS AND CAUSING SOME CIRCUIT BREAKERS TO POP. THE TERMINAL LUSDR 2005UALA00526Attach Angle · crackedFWD NOSE AREA, STA 202 BULKHEAD, LT SIDE HAS ATTACH ANGLE CRACKED OUTBOARD OF FRAME ON LOWER SIDE LBL 36 AREA, REAR SIDE OF BULKHEAD. REPLACED BULKHEAD ATTACH ANGLE PER BAC DWG 141N5811-U1 AND INSTALLED PER SRM 51-40-2SDR 2005UALA00527Attach Angle · crackedFWD NOSE AREA STA 202 BULKHEAD, RT SIDE HAS ATTACH ANGLE CRACKED OUTBOARD OF FRAME ON LOWER REAR SIDE OF BULKHEAD, RBL 30-36. REPLACED BULKHEAD ATTACH ANGLE PER BAC DWG 141N5811-U2 AND INSTALLED PER SRM 51-40-2.SDR 2005UALA00551Relief Valve · leakingEES WAS TEST FIRED AND PRESSURE RECORDED GOOD. HOWEVER, THE BOTTOM TUBE WENT FLAT WITHIN 5 MINUTES OF INFLATION PRESSURE RELIFE VALVE FOUND LEAKING. PRESSURE RELIEF VALVE ASSEMBLY WAS REPLACED.SDR 2005UALA00502Frame · dentedAFT PIT LT SIDE AT STA 1460, FRAME HAS DENT ON INBOARD FLANGE BETWEEN STR 25L-26L. REPAIRED FRAME WITH FABRICATED PRODUCTION SPLICE ANGLE-DOUBLER PER TIMCO REO(EVA) G10547, REV. B.SDR 2005UALA00503Frame · dentedAFT PIT STA 1520 FRAME HAS DENT BETWEEN STR 25L AND 26L ON INBOARD FLANGE. REPAIRED FRAME WITH FABRICATED PRODUCTION SPLICE ANGLE DOUBLER PER TIMCO REO(EVA) G10549, REV B.SDR 2005UALA00504Frame · dentedAFT PIT STA 1480 FRAME HAS DENT ABOVE STR 26L ON INBOARD FLANGE. REPAIRED FRAME WITH FABRICATED NESTED J-ANGLE PER TIMCO REO(EVA) G-10556, REV. C.SDR 2005UALA00505Frame · dentedAFT PIT LT SIDE STA 1440 FRAME HAS A DENT ON INBOARD FLANGE BETWEEN STR 25L AND 26L. REPAIRED FRAME WITH A FABRICATED PRODUCTION SPLICE ANGLE DOUBLER PER TIMCO REO(EVA) G10548, REV B.SDR 2005UALA00511Skin · dentedDENT IN FUSELAGE FROM APPROXIMATELY STATION 1720 TO 1701. DENT IS BETWEEN STRINGER 22L & 23L. INSTALLED DOUBLER PER SRM 53-00-01 REPAIR NR 3.SDR ASMF200506006Bleed Valve · failedCAPTAIN REPORTED THAT DURING TAKEOFF, THE LT ENGINE EGT REACHED 647 DEGREE C. AIRCRAFT WAS SENT TO THE HANGAR AND LT ENGINE 2.5 BLEED ACTUATOR WAS REPLACED IAW MM 75-32-01 AND TESTS WERE PERFORMED IAW MM 71-00-00, ALL CORRECT. DURING OVERNIGHT SERVICE, THE LT SDR 2005UALA00501Skin · dentedFUSELAGE SKIN DENTED STA 600-640, STR 27L TO 16L. TRIMMED OUT DAMAGE AND INSTALLED SKIN SPLICE REPAIR PER SRM53-30-12, AND EVA-50352 AND REO -G10623A.SDR ASMF200506003Idg · failedAIRCRAFT RETURNED, LT GENERATOR FAILURE, APU DID NOT START AT 35 000 FT, 24 22 25 EICAS MESSAGES, 01 GEN OFF DISPLAYED AND 01 AS BUSS OFF REMAINED ILLUMINATED. QRH ABNORMAL PROCEDURE WAS PERFORMED, PAGE 09-03, RETURNING. DURING TEST WAS DETECTED LOW QUANTITY O
Back to Pratt & Whitney PW2037