Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2002UALA01192Engine · power lossPOWER LOSS IN NR 2 ENGINE. THE TEST ON THE FUEL CONTROL UNIT P/N 779100-5, S/N F22470 EXHIBITED SEVERAL PARAMETERS THAT WERE OUT-OF-LIMITS. HOWEVER NONE WERE DEEMED TO HAVE BEEN THE CAUSE OF THE ENGINE SURGE EXPERIENCED ON-WING. FURTHERMORE, THE TESTS FOUNDSDR 2002UALA01182Skin · dentedFUSELAGE DENTED AT STATION 1690-1706, BELOW STRINGER 17R-RADIUS. MAJOR REPAIR ACCOMPLISHED. DOUBLER AND TRIPLER INSTALLED.SDR 2002UALA01186Floorbeam · corrodedCABIN FLOORBEAM STATION 1660 BL 0 UPPER FLANGE HAS 18.6 PERCENT MATERIAL LOSS. MAJOR REPAIR ACCOMPLISHED. REPAIRED FLOORBEAM UPPER CAP. BLEND OUT ANGLE AND STRAP REPAIR.SDR 2002UALA01179Skin · dentedLEFT HAND FUSELAGE STATION 600-640 STRINGER 13L-18L HAS MULTIPLE DENTS. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. INSTALLED FLUSH REPAIR, DOUBLERS AND TRIPLERS.SDR 2002UALA01171Skin · dentedSTATION 220 STRINGER 17L WL 208 FUSELAGE SKIN DENTED. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR.SDR 2002UALA01172Frame · dentedAFT PIT AT STATION 1440 ABOVE STRINGER 26 LEFT, TOP OF FRAME FLANGE DENTED. MAJOR REPAIR ACCOMPLISHED. FRAME DOUBLER INSTALLED.SDR 2002UALA01169Frame · dentedAFT PIT LH SIDE STATION 1400 ABOVE STRINGER 26L TOP OF FRAME DENTED. MAJOR REPAIR ACCOMPLISHED. FABRICATED NEW DOUBLER, STRAP AND CAP INSTALLED.SDR 2002UALA01170Stringer · dentedSTRINGER 14L AT STATION 620 HAS A DENT. MAJOR REPAIR ACCOMPLISHED. SPLICED IN HAT CHANNEL REPAIR.SDR 2002UALA01173Sensor · malfunctionedGEAR DISAGREE LIGHT EICAS MESSAGE. PSEU BITE CHECK SHOWS SENSORS 59 AND 239 (SYSTEM 1 & 2 RIGHT GEAR UPLOCK). SENSORS PASSED TARGET TEST FOR TARGET FAR AND WHEN SLUGGED. NO OTHER DISCREPANCIES.SDR 2002UALA01145Hydraulic System · failedLOSS OF LEFT SYSTEM HYDRAULICS.SDR 2002UALA01138Intercostal · corrodedFORWARD CABIN FLOOR INTERCOSTAL AT STATION 301 TO 310.5 RBL 40 HAS EXCESSIVE MATERIAL REMOVED DURING CLEANUP. MAJOR REPAIR ACCOMPLISHED. REPLACED INTERCOSTAL.SDR 2002UALA01139Floorbeam · elongatedFORWARD CABIN FLOOR BODY STATION 395 LBL 2 T-CAP FASTENER HOLE IS ELONGATED. MAJOR REPAIR ACCOMPLISHED. INSTALLED 10 INCH STRAP AND NESTED ANGLE.SDR 2002UALA01141Skin · dentedCABIN AFT PRESSURE DECK SKIN BLENDED BEYOND LIMITS STATION 1693, RBL 51 AND STATION 1685, RBL 51.5. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED DOUBLER.SDR 2002UALA01136Skin · dentedFUSELAGE SKIN HAD DENT AT FRAME AT STA.288 APPROX. TO STRINGER 19R. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER.SDR 2002UALA01137Skin · dentedFUSELAGE SKIN HAS MULTIPLE DENTS BETWEEN STATION 740 AND 780, AND STRINGER 14L AND 18L. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER AND TRIPLER.SDR 2002UALA01126Door Frame · groovedDOOR 1L CUTOUT FORWARD FRAME 8-10 INCHES FROM TOP CORNER, I/B FLANGE HAD DEEP GROOVE WORN INTO IT. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER OVER FRAME.SDR 2002UALA01123Eec · malfunctionedLT ENGINE COMPRESSOR STALL AT CLIMB THRUST CLIMBING THROUGH 10,000 FT. ENGINE RECOVERED AND CONTINUED NORMAL OPERATION. THE 14TH STAGE BLEED CONVERTER VALVE WAS REPLACED AS PRECAUTIONARY ALONG WITH EEC AS A RESULT OF EICAS MESSAGE 275-27. COMPONENT SHOP CURSDR 2002UALA01112Frame · gougedSTATION 338.5 DOOR 1L SURROUND STUB FRAME WL 278 HAS A GOUGE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. BLENDED GOUGE, INSTALLED REPAIR ANGLE AND MODIFIED DOOR STOP.SDR 2002UALA01104Floorbeam · corrodedCABIN FLOORBEAM BODY STATION 310 FLOORBEAM HAS EXCESSIVE MATERIAL LOSS DUE TO CORROSION AT RBL 42 UPPER SURFACE T-CAP. MAJOR REPAIR ACCOMPLISHED. CUT OUT FILLER AND REINFORCE ANGLES.SDR 2002UALA01105Floorbeam · corrodedCABIN FLOOR BODY STATION 324 FLOORBEAM CAP AT RBL 41 TO RBL 43 HAS SURFACE CORROSION DAMAGE. MAJOR REPAIR ACCOMPLISHED. CUT OUT, FILLER AND ANGLE INSTALLED.SDR 2002UALA01106Skin · dentedEXTERNAL FUSELAGE SKIN DENTED AT LOWER EDGE OF AFT CARGO PIT DOOR CUTOUT STATION 1427 SKIN LAYERS ALSO DISBONDED. MAJOR REPAIR ACCOMPLISHED. DOUBLER AND TRIPLER REPAIR INSTALLED.SDR 2002UALA01107Floorbeam · corrodedCABIN FLOORBEAM HAD EXCESS CORROSION AT STATION 740 RBL 62 STRINGER 17L, ALSO GUTTER UNDER STRUCTURE L-CHANNEL WAS CORRODED STATION 740, 62 RBL. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW SECTION OF INNER CREASE BEAM FROM 664 TO 756. A NEW UNDER GUTTER L-CHANSDR 2002UALA01108Floorbeam · corrodedFORWARD CABIN FLOOR T-CAP BODY STATION 324 RBL 59-61 HAS SURFACE CORROSION. MAJOR REPAIR ACCOMPLISHED. CUT OUT FILLER AND ANGLE, INSTALLED FOR T-ANGLE REPAIR.SDR 2002UALA01092Floorbeam · corrodedCABIN FLOOR BODY STATION 365 T-CAP IS CORRODED FROM BL 0 TO RBL 62. MAJOR REPAIR ACCOMPLISHED. REPLACED T-CAP.SDR 2002UALA01080Crease Beam · corrodedCABIN RIGHT HAND CREASE BEAM HAS CORROSION AROUND 2 NUTPLATES STATION 1020 TO STATION 1029 RBL 64. MAJOR REPAIR ACCOMPLISHED. REPLACED AND SPLICED IN NEW SECTION OF INNER CREASE BEAM.SDR 2002UALA01081Crease Beam · corrodedCABIN FLOOR CREASE BEAM WEB CORRODED AT STATION 1004 RBL 68 UPPER SURFACE. MAJOR REPAIR ACCOMPLISHED. REPLACED CREASE BEAM WEB.SDR 2002UALA01073Skin · dentedEXTERNAL FUSELAGE HAS SEVERAL DENTS AT LEFT HAND SIDE STATION 600 TO 620 STRINGER 15L TO 17L. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER TRIPLER ON SKIN STATION 600 TO 640 STRINGER 15L TO 18L.SDR 2002UALA01058Skin · dentedFUSELAGE SKIN HAS SEVERAL DENTS AT STATION 595-625 STRINGER 14L-18L. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLERS, TRIPLERS, AND STRUCTURAL FILLERS.SDR 2002UALA01056Floorbeam · corrodedCABIN FLOORBEAM STA 365 RBL 18 MATERIAL REMOVED BEYOND LIMITS. MAJOR REPAIR ACCOMPLISHED. CABIN FLOORBEAM UPPER CAP REPLACED.SDR 2002UALA01057Crease Beam · corrodedRIGHT HAND CREASE BEAM IN FLOOR BELOW SUPPORT ANGLE AT BODY STATION 837 RBL 63 UPPER SURFACE CORRODED AT NUT PLATE HOLE. MAJOR REPAIR ACCOMPLISHED. CREASE BEAM DOUBLER REPAIR INSTALLED.SDR 2002UALA01049Floor Support · corrodedCABIN FLOOR SUPPORT AT STATION 395-418, BL 0, WL 208 CORRODED. MAJOR REPAIR ACCOMPLISHED. CABIN FLOOR SUPPORT REPLACED.SDR 2002UALA01034Stringer · dentedFUSELAGE STRINGER AT STATION 625 HAS A DENT AT STRINGER 18L. MAJOR REPAIR ACCOMPLISHED. STRINGER SPLICED IN NEW SECTION USING HAT CHANNEL.SDR 2002UALA01031Skin · dentedLEFT HAND FUSELAGE HAS SEVERAL DENTS BETWEEN STATION 600 AND 620 ON AND BELOW STRINGER 16L. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER.SDR 2002UALA01032Floor Support · wornCABIN FLOOR SUPPORT IS WORN AT STATION 365 RBL 46. MAJOR REPAIR ACCOMPLISHED. CABIN FLOOR SUPPORT AT STATION 365 RBL 46 WAS REPAIRED.SDR 2002UALA01033Floor Support · corrodedCABIN FLOOR SUPPORT IS CORRODED AT STATION 365 RBL 26. MAJOR REPAIR ACCOMPLISHED. CABIN FLOOR SUPPORT AT STATION 365 RBL 26 WAS REPAIRED.SDR 2002UALA01012Stringer · dentedLEFT HAND FUSELAGE STRINGER 16L AT STATION 600 TO 620 DENT OUT OF LIMITS. MAJOR REPAIR ACCOMPLISHED. STRINGER SPLICED.SDR 2002UALA01013Plate · corrodedAFT CABIN DECK PLATE REPAIR DOUBLER CORRODED AT STATION 1680 TO 1685, RBL 50 TO 55. MAJOR REPAIR ACCOMPLISHED. REMOVE DOUBLER AND NEW DOUBLER INSTALLED.SDR 2002UALA01011Floorbeam · corrodedCABIN FLOORBEAM STATION 365, STRINGER 17R UPPER SURFACE OF UPPER I BEAM FLANGE HAD EXCESS MATERIAL REMOVED DURING CORROSION CLEANUP BETWEEN RBL 4 OUT TO RBL 60. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIRED.SDR 2002UALA01014Floorbeam · corrodedCABIN FLOORBEAM STATION 1640, RBL15-53R, WL208 CORRODED. MAJOR REPAIR ACCOMPLISHED. REPLACED T-CAP.SDR 2002UALA01015Crease Beam · corrodedCABIN FLOOR CREASE BEAM AT STATION 410, LBL 72, WL 208 CORRODED. MAJOR REPAIR ACCOMPLISHED. DOUBLER REPAIR INSTALLED.SDR 2002UALA01016Stringer · crackedAFT FUSE STATION 1830 AT STRINGER 20R WAS PUNCTURED. STRINGER 20R WAS ALSO CRACKED. MAJOR REPAIR ACCOMPLISHED. FUSELAGE SKIN DOUBLER INSTALLED. STRINGER SPLICED WAS INSTALLED.SDR 2002UALA01017Shear Tie · rustedSTATION 310, S1 FASTENER HEAD HAS RUST ON EXTERNAL SURFACE. MAJOR REPAIR ACCOMPLISHED. INSTALLED SHEAR TIE AND DOUBLER.SDR 2002UALA01018Stringer · corrodedSTATION 334 RBL 26-45 WL 208, HAT CHANNEL CORRODED. MAJOR REPAIR ACCOMPLISHED. HAT CHANNEL REPLACED.SDR DL757020665Valve · malfunctionedAT FLT 350-370 LT ENG FLUCTUATED EPR 1.11-1.24, EGT 438-460 AND N1 79.1-82.2. DUCT PRESS FLUX 30-60 PSI. MCC REQUESTED TURN OFF LT BLEED AND FLUX STOPPED. DIVERTED TO MCO DUE TO EN ROUTE WX. PERF PFHB TEST 06 AND 13, NO ANOMALIES NOTED. REPLACED HIGH STAGSDR 2002UALA00998Floorbeam · corrodedCABIN FLOOR SUPPORT CORD HAD CORROSION ON UPPER FLANGE AT STATION 345 TO 365 BL 0 WL 208.10 MAJOR REPAIR ACCOMPLISHED. REMOVED T ANGLE CORD FROM BETWEEN STA 324 AND 417 DRILLED UP NEW PART AND INSTALLED.SDR 2002UALA00997Floorbeam · gougedCABIN FLOOR STRUCTURE AT STATION 1200-1220 HAD DEEP GOUGES AT NUT CLIP HOLES, TO INNER CREASE BEAM AT 65 LBL STRINGER 17L. MAJOR REPAIR ACCOMPLISHED. FABRICATED REPLACEMENT AND INSTALLED WITH EXTERNAL SPLICE AT STA 1230 ONE L ANGLE AND L ANGLE WITH FLANGE.SDR 2002UALA00977Floorbeam · gougedMID-CABIN FLOORBEAM STA 880, LBL 49 TO 65, IS GOUGED AROUND CLIP NUT HOLES, FORWARD TOP SIDE AND AFT LOWER SURFACE RADIUS. MAJOR REPAIR ACCOMPLISHED. INSTALLED FREEZE PLUG AND STRAP REPAIR.SDR 2002UALA00984Transceiver · faultyWEATHER RADAR INOPERATIVE. THE POWER OUT IS MEASURING 125W MAXIMUM, DURING TEST. THE MINIMUM ACCEPTABLE POWER OUTPUT FOR A SERVICEABLE UNIT IS 175W. MOST UNITS ARE IN THE 250W RANGE. REPLACED THE A5 ASSEMBLY . THE LRU'S LOW POWER OUT CONDITION CORRELATES SDR 2002UALA00976Channel · corrodedCABIN FLOOR STRUCTURE AT STA 334, WL 208, BL 0 TO RBL 25, U-CHANNEL INTERCOSTAL HAD EXCESSIVE CORROSION ON UPPER SURFACE. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW U-CHANNEL.SDR 2002UALA00974Power Supply · contaminatedWEATHER RADAR FAIL ANNUNCIATED. SUPPLEMENTAL DATA UPDATE THE UNIT HAD A FAILED POWER SUPPLY ASSEMBLY. NOTE WORTHY IS THAT THE UNIT HAD BEEN ON THE AIRCRAFT SINCE 01AUG96 AND WAS TOTALLY CLOGGED WITH DUST WHICH ULTIMATELY LED TO THE POWER SUPPLY FAILURE.
Back to Pratt & Whitney PW2037