SDR DL757951037Actuator · faultyDURING CRUISE, HAD SVA FAILSAFE MSG, NR 2 ENGINE FLAMED-OUT. LANDED RDU. RAN ENGINE PER PFHB TEST 14 SVA, TEST NORMAL. FERRIED AC TO ATL. REPLACED STATOR VANE ACTUATOR, RETURNED TO SERVICE.SDR 95UAL757006Rstract Mech · malfunctionedDURING APPROACH THE FLIGHT CREW WAS UNABLE TO EXTEND FLAPS FULLY. OP CHECKED FLAPS, BITE CHECKED FLAP SLAT ELECTRONIC UNIT, AND VISUALLY INSPECTED FLAPS. NO DEFECTS FOUND.SDR 9503245507Circuit Breaker · trippedDURING TAKEOFF AS TAKEOFF POWER WAS APPLIED, THE NR 1 THRUST LEVER WAS UNABLE TO REACH FULL TAKEOFF. THE TAKEOFF WAS ABORTED. THE LEFT REVERSER INTERLOCK CIRCUIT BREAKER WAS RESET AND THE SYSTEM CHECKED OK.SDR 95UAL757005Eel Battery Pack · dischargedEEL LIGHTS INOP ROWS 24 TO 32. REPLACED BATTERY PACK M735.SDR 95UAL757004Engine · malfunctionRIGHT ENGINE MADE UNCOMMANDED INCREASE TO MAX POWER. SHUTDOWN ENGINE. DISASSEMBLY SHOWED SIGNS OF METAL SLIVERS ON THE LOW SIDE OF THE PRESSURE RELIEF VALVE WHICH CAUSED THE VALVE TO MALFUNCTION.SDR 95UAL757002Eel Battery · dischargedEMERGENCY EXIT SIGNS IN FIRST CLASS INOP. SIGNS POWERED BY SAME BATTERY. REPLACED BATTERY, OPS CKS OK.SDR 95UAL757003Eel Power Cable · failedEEL INOP ROW 25C-32C. REPLACED POWER CABLE. OPS CKS OK.SDR DL757950191Pump · crackedDURING CRUISE, NR 2 ENGINE OIL QUANTITY STEADILY DECREASED. INSPECTION OF NR 2 OIL SYSTEM FOUND THE ENGINE SCAVANGE OIL PUMP WITH A CRACKED PUMP CASE. REPLACED OIL PUMP, OPERATION NORMAL.SDR 9500405520Indication · malfunctionDURING CRUISE, RECEIVED 'L ENG OIL COOL' AND 'L ENG PRICONT' STATUS MESSAGE. THE EPR BLANKED OUT AT THE LOWER POWER SETTINGS BELOW 1.1 EPR. OIL TEMPERATURES REMAINED IN NORMAL POWER RANGES. AIRCRAFT DIVERTED TO DTW AND LANDED WITHOUT INCIDENT. MAINTENANCE SDR 95UAL757001Slide · damagedDURING OVERHAUL OF THE RIGHT OFF-WING SLIDE, THE WEBBING BETWEEN THE RAMP AND SLIDE PORTION OF THE UNDERSIDE DISBONDED FROM THE LOWER TRUNK TUBE. RE-ATTACHED DISBONDED WEBBING WITH ADHESIVE.
Back to Pratt & Whitney PW2037