Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012121407252Skin · damagedTHE FUSE SKIN REPAIR INSTALLED PER ECRA 5361-01031 BETWEEN BS 1384 - 1401, AND STR 28L -29R RECEIVED FIRST AND SECOND STAGE APPROVAL. MAJOR REPAIR ACCOMPLISHED: DOUBLER INSTALLED OVER EXISTING HOLE AT STA 1393, STR 30.SDR UALA2012121407251Light · inoperativeEEL LIGHT STRIP AT FWD COAT CLOSET INOP. PERFORM TS ON EEL LIGHT STRIP AT FWD COAT CLOSET OPEN. REPLACE EEL LIGHT STRIP IAW B757 A MM 33-51-11. PERFORM OPS CHECK OF EEL LIGHT STRIP AT FWD COAT CLOSET, OPS CHECK FOUND NORMAL IAW AMM B757 33-51-00.SDR UALA2012121407241Unknown · leakingBLUE WATER LEAKING FROM WEEP HOLE UNDER AFT PIT. AFT PIT PANELS WAS OPENED BY PREVIOUS SHIFT, DID NOT FIND ANY SOLID EVIDENCE OF BLUE WATER LEAK (WITH THE DUMP VALVES OPENED, HAD LAV SERVICE PERSON CYCLE THRU 30-40 GALS THRU FILL LINE. NO LEAKAGE NOTED. LAVSDR UALA2012121407227Floorbeam · corrodedAFT CABIN STA 1640 FLOORBEAM UPPER CAP CORRODED RBL 58 .22 TO BL 0. UPPER CHORD REPAIR ACCOMPLISHED PER ECRA 5310-05634.SDR UALA2012121407246Support Beam · corrodedSTA 1661 TO 1681 BL 0 SUPPORT P/N 146N5650-1 CORRODED. REMOVED AND REPLACED SUPPORT BEAM IAW SRM.SDR UALA2012121407236Oven · contaminatedBURNED PLASTIC SMELL IS EMANATING FROM FORWARD GALLEY OVENS. REMOVED BURNT PLASTIC MATERIAL FROM OVEN, RAN OVEN 12 MINS, OPS CHECK NORMAL.SDR UALA2012121407235Bracket · corrodedEXFOLIATION-CORROSION UNDERNEATH STIFFENING BRACKET. INSIDE APU INLET PLENUM ABOVE AFT CTR SUPPORT CASTING FOR ENGINE MOUNT (POPPED RIVET HEAD "MARKED"). CLEANED CORROSION AND REPAIRED STIFFENING BRACKET REF SRM.SDR UALA2012121407239Light · inoperativeEEL AT AFT LAV IS IN-OP. REPLACED EEL STRIP.SDR UALA2012121407225Oxygen Mask · unknownFWD CABIN SMALL O2 BOTTLE MASK NEEDS TO BE REPLACED. REPLACED O2 MASK AS REQUIRED.SDR UALA2012121207191Oil Cap · out of positionAPU FLAMEOUT, FLIGHT DIVERTED. FLAMED OUT WHEN ELECTRIC POWER APPLIED. FOUND APU OIL CAP OFF OIL TANK & OIL QTY AT APPROX 2 QTS. INSPECTED CHIP DETECTOR AND NO METAL NOTED. REMOVED AND REPLACED CHIP DETECTOR AS IT ALSO WAS LEAKING. SERVICED APU OIL QTY TOSDR UALA2012121407206Skin · dentedFUSELAGE SKIN FOUND DENTED AT BS 1732 S29 - 30L. FOUND OUT OF SRM LIMITS. CUT OUT DAMAGE AND ACCOMPLISHED NDT OF CUT-OUT AND HOLES COMMON TO REPAIR. FABRICATED AND INSTALLED EXTERNAL DOUBLER REF SRM 53-00-01 FIG 201 DETAIL 1. MAJOR REPAIR.SDR UALA2012121207179Panel · faultyF/O VHF RADIO RIGHT HAS LOUD SIDE TONE. FOUND F/O'S ASP AT FAULT. REMOVED AND REPLACED SAME AMM, OPS CHECKED OK.SDR UALA2012121407245Shutoff Valve · failedNR 2 ENGINE HPSOV FAILED HEALTH CHECK ON TASKCARD 5R36I5053. 535053 REMOVED & REPLACED NR 2 ENGINE HPSOV IAW 36-11-07. PERFORMED HEALTH CHECK ON CARD 5S365S068-NO DEFECTS NOTED. PERFORMED LEAK CHECK IAW 36-11-07-NO LEAKS NOTED IAW AMM 36-11-09.SDR UALA2012121007155Switch · faultyLEFT MAIN LANDING GEAR DOOR UNSAFE LIGHT STAYS ON WITH DOOR CLOSED. REPLACED LEFT GEAR DOOR CLOSED SWITCH S10371 REF WDM-32-12-12 AND AMM. DOOR NOW OPERATES NORMAL.SDR UALA2012121207163Sliding Window · faultyWINDOW EICAS MSG DISPLAYED POSITION 4. (1=L FWD, 2=L SIDE, 3=R FWD, 4=R SIDE) INOP LIGHT ILLUM. FOUND FO'S SLIDING WINDOW R2 HEATER RESISTANCE READING 200 OHMS. WINDOW CONTROL SENSORS CK'D OK. NEED WINDOW PANE & WINDOW THICKNESS GAUGE. INSTALLED NEW LAMINASDR UALA2012121207178Relay · faultyFWD CARGO DOOR WILL NOT CLOSE ELECTRICALLY. REPLACED NR 1 CARGO DOOR HINGE PDU LOWER RELAY REF WDM. OPS CHECK OKAY.SDR UALA2012121207187Cap · unknownNEED WINDOW HT TERMINAL LUG SCREW CAP L3 WINDOW. PLACED L-3 WINDOW HEAT INOP PER MEL3041E.SDR UALA2012121207177Oxygen System · low pressureCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED CREW O2 TO LIMITS AS PER AMM. BEFORE SERV 1200 PSI. AFTER SERV 1500 PSI.SDR UALA2012121207181Module · faultyELEV ASYM EICAS MSG ON TAXI IN. REPLACED LEFT SAM M524 REF MM27-09-00 AND FIM 27-09-00, ACCOMPLISHED CAT III TEST, NO FAULTS.SDR UALA2012121007151Stringer · damagedSTRINGER 16 LEFT BETWEEN STA 600 AND 620 HAS ELONGATED HOLES. CATEGORY 'A' STRINGER REPAIR INSTALLED TO S-16L BETWEEN STA 593 AND 645 REQUIRES SUPPLEMENTAL INSP PER SRM 53-00-03 REPAIR 1 TABLE 4 ON PG 211.SDR UALA2012121007134Switch · reversedFOUND FWD AND AFT CARGO FIRE EXTINGUISHING ARMING SWITCHES REVERSED. SWAPPED LENSE CAPS, TEST OK. CONFIRMED POSITIONS WITH PILOTS FLIGHT MANUAL.SDR UALA2012121207180Actuator · faultyELEV ASYM STATUS MESSAGE ON CLIMBOUT. CONTROLS FEEL NORMAL AND ELEV INDICATORS APPEAR NORMAL. REMOVED AND REPLACED ASYMMETRY LIMITER ACTUATOR IAW AMM, OPS CHECKS GOOD.SDR UALA2012120707106Shutoff Valve · faultyLEFT ENGINE BLD OFF LIGHT ON WHEN LEFT ENG HEAT SWITCHED TO ON POSITION. REPLACED PRSOV PER MM AND AIR SUPPLY OVERTEMP SWITCH.SDR UALA2012120707094Structure · dentedLWR FUSELAGE HAS DENT JUST BELOW FWD RT NOSE NUMBER. AT C CHECK FOUND DENT TO BE OUT OF LIMITS. CUT OUT DAMAGE AND INSTALLED CATAGORY 'B' RPR DBLR PER SRM 53-00-01 RPR 3.SDR UALA2012120707095Skin · damagedFUSELAGE SKIN AT R-4 DOOR CUTOUT LOWER EDGE HAD 3 EACH MISDRILLED HOLES. INTERIM REPAIR INSTALLED STA 1655-1675 BETWEEN S-15R AND S-19R PER ECRA 5330-04378 REQUIRES REPEAT INSP PER STEP 11 OF ECRA.SDR UALA2012120707105Filter · faultyRIGHT RECIRC FAN IS LOUD ENOUGH IN CRZ TO INTERFERE WITH NORMAL COCKPIT COMMUNICATIONS. REPLACE RIGHT RECIRC FAN FILTER IAW AMM. RIGHT RECIRC FAN OPS NORMAL.SDR UALA2012120707107Block · faultyAFT CARGO FIRE IND LIGHT ON CTR CONSOLE BULB IS BLOWN. REPLACED DIODE BLOCK IN SWITCH, OP OKAY.SDR UALA2012121207169Girt Bar · jammedPRIOR TO DEPARTURE, 1R HARD TO ARM. UNJAMMED ARMING SLIDE ON GIRT BAR. OPS OK, SLIDE LIGHT OK.SDR UALA2012120707089Wire Harness · faultyLEFT SIDE WINDOW HEAT INOP. DISCONNECTED CONN D41578J INSULATED AND SECURED REF WDM 20-41-12 PG 1. REPLACED WIRE HARNESS.SDR UALA2012120707091Receptacle · damagedGROUND POWER RECEPTICLE DAMAGED. CASING IS CRACKED, 4 PINS DAMAGED. REPLACED RECEPTACLE PER MM.SDR UALA2012120707108Fitting · dirty1R UNABLE TO ARM. CLEANED GIRT FITTINGS, OPS GOOD.SDR UALA2012120707110Pseu · faultyEICAS STATUS MESSAGE--NOSE A-G DISAGREE. REPLACED THE PSEU, SYSTEM CHECKED OKAY.SDR UALA2012120607056Pouch · brokenCABIN SVC REPORTS: 14DE LIFE VEST POUCH BROKEN. SECURED LIFE VEST POUCH.SDR UALA2012120406951Control Panel · faultyWX RETURNS ERRATIC ON WXR DISPLAY. CREW COMMENTS: FELT LIKE IT WAS MAGENTA TEST IS NORMAL PATTERN. REPLACED WEATHER RADAR TRANSCEIVER, AND TESTED PER AMM 34-43-01. REPLACED WEATHER RADAR CONTROL PANEL, AND TESTED PER AMM 34-43-02.SDR UALA2012120607058Seal · kinkedDOOR 1L HAS LOUD SQUEAL BELOW FL180 POSSOBLE SEAL LEAK. FWD EDGE DOOR SEAL KINKED BY LOWER GATE AREA, LOWER DOOR HINGE LEAKING, ALSO DUE TO EXCESSIVE SEALANT. ADJUSTED LOWER FWD SEAL TO REMOVE KINK, PRESSURIZED AC TO 4 PSI.SDR UALA2012120607057Angle · corrodedMAIN CABIN FLOOR STRUCTURE STA 301 RBL 60 CREASE BEAM INNER CORD ANGLE HAS CORROSION. INSTALLED NEW CORD ANGLE IAW DWS141N8422 AND SRM 51-40-02.SDR UALA2012120607069Regulator · faultyLEFT DUCT PRESSURE FLUCTUATING FROM 25 - 45 PSI AT 41000 FEET CRUISE ALTITUDE. REPLACED LT ENGINE PRSOV REGULATOR IAW AMM. CHECK PNEU BLEED LINE TO PRSOV AND REV FLOW VALVE AND PRSOV REG ALL LINE ARE SECURED AND TIGHT. ACP'D ENGINE RUN WAS GOOD LT AND RT PNSDR UALA2012121007143Medical Kit · unserviceableNO SAFETY WIRE ON BP CUFFS OF EMERGENCY MEDKIT IN COCKPIT. PLACED ON DF REF MEL 2564H. REPLACED COCKPIT EMERGENCY MEDKIT.SDR UALA2012120406948Threshold · damagedAFT GALLEY FLOORBOARD CAME OFF. FLOORBOARD OK. PLASTIC THRESHOLD BETWEEN UNDER CART FLOOR COVER AND GALLEY AREA RUBBER MAT PULLED UP AND TORN. REMOVED DAMAGED THRESHOLD AND SECURED AREA WITH TAPE 20-DAY LIMIT.SDR UALA2012120407030Connector · dirtyFWD CARGO DET 1 STATUS MSG NO CLEAR :NO TIME. CLEANED CONNECTOR AT FWD DETECTOR AND OPS NW NORMAL.SDR UALA2012120406940Skin · damagedSKIN DENTED STA 729, STR 32R TO 33R, 3 PLACES. MAJOR REPAIR ACCOMPLISHED: DAMAGE IS AT STA 729, BETWEEN STR 24R AND 25R. DOUBLER REPAIR INSTALLED PER SRM 53-00-01, REPAIR 3 FIGURE 201.SDR UALA2012120406941Skin · damagedFUSELAGE SKIN CREASED AT STA 615 BETWEEN STR 28L AND 28R (SEE CF9043). MAJOR REPAIR ACCOMPLISHED: DOUBLER REPAIR INSTALLED PER SRM 53-00-01 REPAIR 3 FIGURE 201.SDR UALA2012120406947O-Ring · leakingHYDRAULIC QUANTITY LOW - SYSTEM RT. FOUND HYDRAULIC LEAK AT SPOILER NR 11. FOUND DAMAGED O-RING AT FITTING, REPLACED SAME NAS1612-16, LEAKS AND OPS CHECKS GOOD. HYDRAULIC SYSTEM SERVICED TO FULL.SDR DALA1256060603Inlet · damagedNR 1 ENGINE INLET COWL RT SIDE 9 OCLOCK POSITION HAS A DENT. DENT OUT OF LIMITS IAW SRM 54-11-01. R & R NR 1 ENGINE INLET COWL IAW AMM 71-11-01.SDR UALA2012120306916Skin · dentedFUSELAGE CREASE APPROX 1 FT AFT OF DOOR 3R AT MID LEVEL. MAJOR REPAIR ACCOMPLISHED. FUSELAGE SKIN DENT IS SMOOTH, CRACK FREE & WITHIN LIMITS PER SRM 53-00-01PG101. NO ACTION REQUIRED. DAMAGE WAS AT STA 1707, BETWEEN STR 15R & 16R. FOUND TO BE OUT OF LIMISDR UALA2012120306928Skin · damagedFUSELAGE SKIN AT R-1 DOOR CUTOUT LOWER EDGE HAS 6 EACH MIS-DRILLED HOLES. INTERIM REPAIR INSTALLED STA 320-370 BETWEEN S-15R AND S-18R PER ECRA 5330-04377.SDR UALA2012120406990Spar · damagedINTERIM REPAIR TO THE RIGHT INBD MAIN FLAP FRONT SPAR LWR CHORD AT MFS 223. REF ECRA 5750-04506.SDR UALA2012120406984Structure · corrodedPASSENGER CABIN BS 1712 RBL 50 WL 208 UPPER SURFACE OF SUBFLOOR HAS SMALL AREA OF BARE METAL. MAJOR REPAIR ACCOMPLISHED: REMOVED CORR BY BLENDING OUT DAMAGE, OUT OF LIMITS IAW 53-00-51. REPAIRED AREA BY FAB REP AIR DOUBLER AND FILLER PER ECRA 5330-04259.SDR UALA2012120306909Structure · damagedCLASS B DOUBLER REPAIR INSTALLED AT ST 1707 BETWEEN STR 15R AND 16R, PER SRM 53-00-01 REPAIR 3 FIG 201 (REF PTT# 7646052). REFER TO SRM 53-00-01, REPAIR 3, FIG 201, TABLE 5.SDR UALA2012120306910Skin · damagedCLASS 'B' FUSELAGE SKIN DOUBLER REPAIR INSTALLED AT STA 610, STR 16L, PER SRM 53-00-01 REPAIR 2, FIG 201, (REF PTT# 7646050). INSTALLED DOUBLER REPAIR PER SRM 53-00-01 REPAIR 2, FIGURE 201. REPAIR WAS ACP ON NR1468535. REFER TO SRM 53-00-01 REPAIR 2 FIG 201
Back to Pratt & Whitney PW2037