Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011112706490Skin · dentedON INSPECTION OF FIXED LEADING EDGE, UNDER RT INBOARD SLAT NR 6 FOUND DAMAGED. TWO, SIX INCH OVAL DENTS MEASURING 1-4 INCH DEEP IN COMPOSITE STRUCTURE. REPAIRED PER SRM.SDR UALA2011112206435Light · inoperativeLAST SECTION OF EMERGENCY LIGHT EEL DID NOT COME ON DURING EEL BATTERY DRAIN CHECK. INSTALLED NEW SECTION EEL STRIP AND OPS CHECKS NORMAL JIC 5R33AD216 DURING HMV 3 VISIT.SDR UALA2011112106396Skin · delaminatedCREW REPORT: SKIN DELAMINATION ON RT INBD SLAT. ABOUT 12 INCH PIECE CAME OFF DURING CLMB. NO ADVRS CNTR. SAMC TEXT: CREW REPORTS NO VIBRATION FELT AND NO AIRCRAFT TRIM NEEDED. MAINT TEXT: RT INBOARD LEADING EDGE SLAT HAS A LARGE AREA AT THE TRAILING EDGESDR UALA2011112206416Light · inoperativeDOOR 1R SLIDE LIGHT DID NOT COME ON DURING EEL BATTERY TEST. RELAMPED AND OPS CHECKS NORMAL.SDR UALA2011112206417Light · inoperativeDOOR 1R SLIDE LIGHT DID NOT COME ON DURING EEL BATTERY DRAIN TEST. RELAMPED AND OPS CHECKS NORMAL.SDR UALA2011112206419Lamp · inoperativeLAVATORY LIGHTS INOPERATIVE AT DOOR-3L AFT-CABIN AFT LAVATORY. RELAMPED DOME LIGHT.SDR UALA2011112206441Girt Bar · obstructedDOOR 4R WILL NOT ARM. REMOVED DEBRIS FROM GIRT BAR RECEPTICAL.SDR UALA2011112106343Rvdt · out of adjustSPOILER EICAS MSG. DUE TO THE HISTORY OF THE SPOILER EICAS MSG AND ASC LIGHT, ADJ THE CONTROL WHEEL RVDTS PER MM 27-61-00 P515. POSSIBLE PARTS REQ RVDT TS5082 PCN 480-9277. VERIFY EFFECTIVITY WITH ONLINE IPC. FOUND LT CONTROL WHEEL RVDT AT-.50 VOLTS. FOUNSDR UALA2011112106394Skin · cracked(.125) OF AN INCH CRACK VERIFIED IN CROWN SKIN AT STATION 407. FOUND CRACK INDICATION AT STR 4L STA 406 APPROX 1-8TH IN LONG AT CHEM MILL RADIUS.SDR UALA2011112106379Skin · damagedDOOR 4R CUTOUT HAS 2 EA ATTACH HOLES FOR SCUFF PLATE THAT ARE ELONGATED ALONG FUSE SKIN EDGE. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SKIN AND INSTALLED DOUBLER-TRIPLER-QUAD REPAIR REF EC-RA 5330-04171 AND EVA 81518.SDR UALA2011112106380Light · inoperativeEMERGENCY EEL AISLE LIGHT AT ROW 34L DID NOT COME ON DURING EEL BATTERY DRAIN TEST. RELAMPED, OPS CHECKS NORMAL.SDR UALA2011112106381Light · inoperativeL-H NO-W EMERGENCY ESCAPE LIGHT DID NOT COME ON DURING EEL BATTERY DRAIN TEST. RELAMPED EMERGENCY LIGHT.SDR UALA2011112106386Charger · inoperativeEMERGENCY LIGHTS L56, L57, L60, AND L1065 DID COME ON DURING EEL BATTERY DRAIN TEST (COMMON TO POWER SUPPLY M10817). REPLACED M10818 BATTERY CHARGER AND OPS CHECKS NORMAL.SDR UALA2011112106353Wire · disconnectedL REV ISLN VAL' MESSAGE NOT DISPLAYED DURING NR 1 ENGINE AUTO RESTOW CHECK. REF A-CHECK JOB CARD 5-5501. FOUND WIRE W3386-2521B-20 REMOVED FROM D5014 AND CAP & STOWED (CONT OF AMIS ITEM 9732002). INSTALLED CONTACT ON WIRE AND REPLACED IN CONNECTOR, THRUST RSDR UALA2011112106351Light · inoperativeDOOR 2R EMERGENCY EXIT LIGHT IS INOP. CLEANED SOCKET & RELAMPED. CHECKS NORMAL.SDR UALA2011112106363Door Frame · icedPASSENGERS COMPLAIN ABOUT ICE FORMING ON INSIDE FRAME OF EMER EXIT WINDOW AT 20A. COLD AIR TOO. INSPECTED DOOR FRAME AND SURROUND AT 20A, FOUND NO EVIDENCE OF ICE OR DAMPNESS. NO COMPLAINTS OR HISTORY OF LEAKS AT HATCH AREA.SDR UALA2011112106342Actuator · out of adjustSPOILER EICAS MSG CAME ON IN CRUISE. CHECK RVDT ADJUSTMENT AND RIG ADJUSTMENT ON NR 4 SPOILER. CHECKED RVDT ADJUSTMENT AND ADJUSTED. CHECKED RIG ON SPOILER AND ADJUSTED NR 4 SPOILER. OP CHECKED GOOD.SDR UALA2011111806320Oxygen Mask · defectiveCREW REPORT: O2 DEPLETES APPROX 10 PSI-SEC WHEN CAPTS MASK IS TESTED. REPLACED CAPTAIN'S OXYGEN MASK, OPS CHECKS GOOD.SDR UALA2011111806323Cap · missingEMERGENCY ESCAPE LIGHTING STRIP END CAPS MISSING NEXT TO 1B. REPLACED END CAP.SDR UALA2011111806324Cap · missingEMERGENCY ESCAPE LIGHTING STRIP END CAPS MISSING AT 40C. REPLACED END CAP.SDR UALA2011111806325Frame · corrodedFRAME STA 1400 HAS CORROSION FROM RBL 7 TO RBL 12. MAJOR REPAIR ACCOMPLISHED IAW ECRA 5311-01536, EVA 81492, AND S-CO NR 9953206.SDR UALA2011111806326Tee Fitting · corrodedCARGO DOOR LOWER T-CHORD AT STA 1377 HAS CORROSION ON VERT AND HORIZ LEGS. MAJOR REPAIR ACCOMPLISHED IAW ECRA 5310-05421, EVA 81493, AND S-CO NR 9954083.SDR UALA2011112106344Plate · faultyGALLEY HOT PLATE WON'T HEAT AT 411H. CREW COMMENTS: WON'T HEAT. FWD GALLEY LOWER HOT PLATE H12 IS INOP. REPLACED HOT PLATE AT FWD GALLEY POSITION H12, OPS NORMAL.SDR UALA2011111806336Sink · unknownFWD GALLEY FLOODED WITH WATER. FOUND AN EXCESSIVE AMOUNT OF LIQUID DUMPED THRU FWD GALLEY TRASH SHOOT LEAKING DOWN THE SIDE OF TRASH CONTAINER. TRASH CAN LINER WAS NOT INSTALLED PROPERLY CAUSING FLUID TO LEAK ON THE SIDES OF THE TRASH CAN AND DOWN TO THE FLOOSDR UALA2011111806337Control Module · faultyRUDDER TRIM COMPLETELY INOP. INDICATOR AND RUDDER DO NOT MOVE. MAINT TEXT: DUE HISTORY, RECOMMEND REPLACEMENT OF RUDDER TRIM ACTUATOR REF SVC TIP. PCN 563-9038 AVAIL SFO. REPLACED AILERON AND RUDDER TRIM CONTROL MODULE PER MM, OPS CHECKED GOOD.SDR UALA2011111706314Beam · damagedRIGHT SIDE STUB BEAM STA 984 NR 3 AND NR 5 HOLES OUT OF ROUND. BOTH REPAIRED IAW ECRA 5340-01453,EVA 81473A,TIME LIMITED REPAIR TO BE REPLACED WITHIN 24 MONTHS FROM 02NOV11 OR WITH 3000 CYCLES. REF ECRA 5340-01453, REPLACE RIGHT SIDE STUB BEAM STA 984 WITHINSDR UALA2011111606276Sensor · obstructedDOOR 4R 'ARMED' LIGHT INOP. CLEANED DEBRIS FROM GIRT BAR SENSORS, OPS CHECKS GOOD.SDR UALA2011111606278Light · inoperativeDOOR FOUR RIGHT EMERGENCY LIGHT OUT. RELAMPED PER MM.SDR UALA2011111706297Beam · damagedRIGHT SIDE STUB BEAM STA 984 FASTENER HOLE NR 3 OUT OF ROUND REF AVO ESC111018-5684-1. INTERIM REPAIR INSTALLED PER ECRA 5340-01453, EVA 81473, AND S-CO NR 9953844.SDR UALA2011111706298Beam · damagedLEFT SIDE STUB BEAM AT STA 984 FASTENER HOLE NR 5 OUT OF ROUND. INTERIM REPAIR ACCOMPLISHED IAW ECRA 5340-01452, EVA 81474, AND S-CO NR 9953892.SDR UALA2011111706299Beam · damagedRIGHT SIDE STUB BEAM AT STA 984 FASTENER HOLE NR 5 ELONGATED. INTERIM REPAIR ACCOMPLISHED IAW ECRA 5340-01453, EVA 81473A, AND S-CO NR 9953846. STUB BEAM REQUIRES REPLACEMENT WITHIN 24 MONTHS FROM 02NOV11, OR 3000C, WHICHEVER OCCURS 1ST.SDR UALA2011111706300Beam · damagedLEFT SIDE STUB BEAM AT STA 984 FASTENER HOLE OUT OF ROUND. INTERIM REPAIR INSTALLED PER ECRA 5340-01452, EVA 81474, AND S-CO NR 9953891, STUB BEAM REQUIRES REPLACEMENT BEFORE 24 MONTHS FROM 2NOV11.SDR UALA2011111706301Beam · damagedLEFT SIDE STUB BEAM AT STA 984 FASTNER HOLE NR 3 AND NR 5 OUT OF ROUND. INTERIM REPAIR INSTALLED IAW ECRA 5340-01452 AND EVA 81474. REF ECRA 5340-01452 LEFT STUB BEAM STA 984 TO BE REPLACED WITHIN 24 MONTHS FROM 02NOV11 OR WITHIN 3000CYCLES. CURRENT PTC 212SDR UALA2011111706302Strap · corrodedAFT PIT STA 1400, CORROSION AT INTERNAL SKIN STRAP BETWEEN STR 29R-28R. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE AND INSTALLED DOUBLER RPR REF EC-RA 5330-04169 AND EVA 81500. N-R 9953560.SDR UALA2011111706303Strap · corrodedAFT CARGO STA 1400, IGC CORROSION AT INTERNAL STRAP BETWEEN STR 29R AND 28R BELOW RIB. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE AND INSTALLED DOUBLER REPAIR. CF9088 CREATED FOR DTA. REF EVA 81500 AND EC-RA 5330-04169.SDR UALA2011111606285Actuator · faultyEICAS MESSAGE 'SPOILERS' DISPLAYED. SPOILERS LIGHT ILLUMINATED WITH SPEEDBRAKE LEVER SELECTED TO DOWN. DEFERRED REF MEL 2761A LOCKED OUT SPOILERS 4 AND 9. FOUND NR 4 PCA RVDT OUT OF RANGE, WITH NO RESPONSE WHEN TRYING TO MAKE AN ADJUSTMENT. NEED TO REPLACESDR UALA2011111606270Duct · obstructedABNORMAL NOISE & VIB IN FLT DECK. FOUND DEBRIS IN CENTER DIST DUCTING. DUCTING HAS BEEN CLEANED FROM ROW 40 FWD TO ROW 30. NEED TO COMPLETE DUCT CLEANING FROM ROW 30 FWD. REMOVED LARGE DEBRIS ITEMS, FROM FLT DECK MAIN DIST DUCT AT TEMP BULB (WITH HOLE MULTSDR UALA2011111706289Carbon Seal · leakingEVIDENCE OF OIL LEAK NR 2 ENG. NR 2 ENGINE RUN FOR APPROXIMATELY 5 MINUTES, NO LEAKS NOTED. ONE HOUR AFTER HIGH POWER BAG CHECK. IDG DRIVE PAD DRAIN STARTED LEAKING 60 DROPS PER MIN STATIC. DRAINED IDG AND STARTED DISCONNECTING FOR REMOVAL. REPLACED DRIVE SDR UALA2011111606283Oven · noisyCREW REPORTS FWD GALLEY OVEN (R12) FAN MAKING NOISE. NEEDS NEW OVEN- C-B PULLED AND COLLARED AND DOOR PLACARD. OVEN (028-9005) ITEM NR 1 OF IPC. OVEN OPS CHK OK NOISE LEVEL NORMAL PER LAXMM.SDR UALA2011111506241Engine · making metalNR 2 ENG RPL 5552-2 ESN 728701: DUE TO METAL FOUND ON THE ANGLE GEAR BOX CHIP DETECTOR AND THE MAIN OIL FILTER EXCEEDING MM LIMITS. REMOVED THE METAL FOUND ON THE AGB CHIP DETECTOR AND PUT INTO A PLASTIC BAG. CLEANED THE CHIP DETECTOR. RE-INSTALL THE AGB CSDR UALA2011111606284Module · faultyFIRE SYS FAIL LIGHT INOPERATIVE. REPLACED M10445 S2 FAIL LIGHT ANNUNCIATOR AND ACP'D OPERATIONAL TEST OF ENGINE FIRE AND OVERHEAT DETECTION SYSTEM PER MM, CHECKS OKAY.SDR UALA2011111506263Carbon Seal · leakingNR 1 ENG FUEL PUMP CARBON SEAL LEAKING OIL OUT OF DRAIN. REPLACED CARBON SEAL PER MM.SDR UALA2011111506264Unknown · vibrationABNORMAL NOISE, VIBRATION IN CENTER MAIN CABIN CEILING. CREW COMMENTS: OVERHEAD AIR NOISE LOUD BETWEEN ROWS 11 - 21 MAINT TEXT: OVERHEAD DISTRIBUTION PANELS OPENED AND CHECKED FOR LEAKS. NONE FOUND. AIRFLOW AT FWD CABIN CHECKS GOOD BUT BEGIN TO DIMINISH SIGSDR UALA2011111506265Oxygen Mask · defectiveF-O MASK MIC HOT. REPLACED F-O'S OXYGEN MASK ASSY. MIC NOW CHECKS GOOD.SDR UALA2011111506266Oxygen Mask · defectiveCAPTAIN'S O2 MASK HOT MIC. REPLACED CAPT OXYGEN MASK ASSY. MIC NOW CHECKS GOOD.SDR UALA2011111506267Cover · separatedCREW REPORT: DOOR 2L EXIT SIGN COVER SEPARATED AND IS ON THE OPEN DOOR NOW. SECURED EXIT SIGN COVER.SDR UALA2011111406181Amu · faultyACARS NO COMM. RESET BREAKER, NO HELP. REPLACED ACARS MANAGEMENT UNIT M172 PER AMM, OPS CHECK NORMAL.SDR UALA2011111406214Fuel/Oil Cooler · leakingNR 1 ENG HIGH OIL CONSUMPTION EXCEEDS LIMIT. REPLACED NR 1 ENGINE FUEL OIL HEAT EXCHANGER PER MM, OPS & LEAK CHECK OKAY.SDR UALA2011111406190Fuel/Oil Cooler · leakingCREW REPORTED OIL LEAK NR 1 ENGINE. OPENED ENG COWL, CLEANED AND INSPECTED NR 1 ENGINE. NO LEAK FOUND. ACCOMPLISHED ENGINE IDLE RUN. FOUND OIL DRIPS FROM FUEL-OIL HEAT EXCHANGER. THREE DROPS PER MINUTE AFTER SHUTDOWN. LEAK RATE IN LIMITS.SDR UALA2011111406194Control Valve · faultyLEFT PACK OFF LIGHT ON AFTER ENG START. REPLACED LEFT PACK CONTROLLER, NO HELP. CLEANED CONNECTOR ON FLOW CONTROL VALVE, NO HELP. ALL DONE WITH REFERENCE TO LOG 1. REPLACED LT PACK FLOW CONTROL VALVE AND PACK OPS NORMAL PER MM.
Back to Pratt & Whitney PW2037