Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011121206829Blades · damagedFOUND FAN BLADE TIP WITH MINOR CURL LESS THAN .125". BLENDED BLADE. INSPECTED USING HFEC, NO CRACKS NOTED.SDR UALA2011120906769Sensor · malfunctionedNO DUCT PRESSURE WITH APU RUNNING AND BLEED OPEN. TRIED RE-SETTING CB'S -NO HELP. SCV, ECU AND FLOW SENSING MODULE REPLACED 06 DEC 11. REPLACED APU INLET PRESSURE (P2) SENSOR PER MM. RAN APU AND DUCT PRESSURE READS 35 PSI, MOTORED NR 2 ENGINE AND APU DUCTSDR UALA2011120906770Actuator · malfunctionedL/E SLAT DISAGREE EICAS, FLIGHT DIVERTED. MESSAGE DISPLAYED & LEADING EDGE LIGHT ILLUMINATED. FLAP INDICATOR NEEDLES STOPPED AT ONE HALF UNIT WITH NO SPLIT. FLAP HANDLE IN UP POSITION. CREW REPORTED NO ABNORMAL VIBRATION OR FLT CONTROL PROBLEMS. CREW FOLLSDR UALA2011120806755Structure · leakingLT WING INBD DRY BAY HAS FUEL LEAK. DUE TO SEVERAL REPORTS OF LEFT WING INBOARD DRY BAY STAIN WITH LEFT TANK FUELED, ACCOMPLISH LEAK CHECK PER MM AND EVALUATE PER FIGURE 602. AFTER COMPLETING THE EVALUATION ACCOMPLISH WING DRY BAY ACCESS DOOR INSPECTION AND SDR UALA2011120906756Connector · disconnectedEMERGENCY EXIT LIGHT STRIP AT LAVS INOP. FOUND PIGTAIL CONNECTION FOR THE EMERGENCY EXIT LIGHT STRIP AT LAVS DISCONNECTED. RE-CONNECTED PIGTAIL AND PERFORMED SUCCESSFUL OPS CHECKS IAW B757 AMM.SDR UALA2011120806743Hose · obstructedGALLEY DRAIN PLUGGED AT DOOR-1R FWD-CABIN FWD GALLEY. CLOG IN SAME AREA HOSE UPSTREAM OF PREVIOUS REPAIR ALSO DAMAGED. NO LEAKS NOTED IN EITHER LOCATIONS. CLEARED LINES AND REPLACED DAMAGED HOSES.SDR UALA2011120806753Actuator · malfunctionedUNWANTED FUEL TRANSFER FROM THE LT WING TO CTR TANK. WITH APU RUNNING AND APU FUEL PUMP ON, FUEL TRANSFERS FROM LT TO CENTER, WITH APU OFF, NO UNWANTED FUEL TRANSFER. UNABLE TO DUPLICATE. RAN APU, NO TRANSFER NOTED WITH OR WITHOUT APU RUNNING. UNWANTED FUESDR UALA2011121206827Pressure Switch · faultyLEFT HYD SYSTEM PRESS LIGHT & EICAS MSG NOT ON WITH PUMP OFF. REPLACED LT HYD SYS LOW PRESSURE LIGHT ASSY, NO HELP. EICAS MESSAGE OK WHEN HYD SWITCH TURNED OFF LIGHT IS INTERMITTENT. REPLACED LEFT SYS PRESSURE SWITCH. OPS CHECKED GOOD.SDR UALA2011120706732Charger · faultyAFTER STANDBY POWER CHECK, BATTERY SHOWS DISCHARGED. REPLACED MAIN CHARGER, TESTS OKAY.SDR UALA2011120706735Modulating Valve · inoperativeAFT CABIN TEMP INOPERATIVE IN AUTO. VERIFIED VALVE CLOSE BY PROCEDURE ONE (1). FAULT SHOWS AFT ZONE VALVE. REPLACED AFT CABIN MODULATING TRIM AIR VALVE PER AMM. OPS CHECKED NORMAL.SDR UALA2011120806736Actuator · malfunctionedSPOILERS EICAS MESSAGE, RTFL CLEANED NR 6 SPOILER PCA CONNECTOR. SWAPPED 1L & 3L SPOILER CONTROL MODULES. OPS CHECKED GOOD IAW MM 27-61-00.SDR UALA2011120606715Skin Splice · corrodedAFT CARGO COMPARTMENT SKIN SPLICE CORRODED BS 1398 - BS 1402, STR 26L - STR 26R. MAJOR REPAIR ACCOMPLISHED. FOUND SKIN SPLICE OUT OF LIMITS PER SRM BETWEEN STRINGERS 28L-29L, 29L-30, AND 30-29R AFTER CORROSION REMOVAL. REMOVED SHEAR TIES AND FABRICATED A NESDR UALA2011120606716Floorbeam · corrodedMAIN CABIN FLOORBEAM IS CORRODED AT STA 310.5 RBL 50. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED SECTION OF T-CAP AND FABRICATED A NEW T-CAP SECTION, REPAIR ANGLES AND STRAPS PER REO G14282, REV A AND EC-RA 5310-05423 ON NON ROUTINE 27866. THIS IS A CATEGORSDR UALA2011120706724Fitting · gougedMAIN CABIN L-2 DOOR AFT DOOR FRAME, INSIDE STRINGER FITTING GOUGED AT BS 728 AND STR 16L. MAJOR REPAIR ACCOMPLISHED. REMOVED THE L-2 DOOR STRINGER FITTING, P/N 143N8348-9, AND FABRICATED A NEW REPLACEMENT FITTING AND INSTALLED PER REO G14319, REV C AND EC-RASDR UALA2011120706726Door Frame · corrodedAFT CARGO DOOR FRAME AT BS 1380 AND RBL 20 IS CORRODED. MAJOR REPAIR ACCOMPLISHED. REMOVED EXISTING CORROSION AND FABRICATED A REPAIR ANGLE, AND PLUGGED 2 EACH OVERSIZED HOLES AND INSTALLED REPAIR PER REO G14321, REV A, AND EC-RA 5310-05424 ON NON ROUTINE 28SDR UALA2011120606717Lamp · inoperativeOVERWING FWD EXTERIOR EMERGENCY LIGHTS INOPERATIVE. RELAMPED, CHECKED GOOD.SDR UALA2011120606700Doubler · dentedEXTERNAL FUSELAGE SKIN DOUBLER HAS A DENT AT BS 610 BETWEEN STR 16L TO STR 17L. MAJOR REPAIR ACCOMPLISHED. REMOVED PREVIOUS BARN DOOR SKIN SPLICE REPAIR, AND FABRICATED A NEW SKIN SECTION AND SPLICE DOUBLERS AND FILLERS AND INSTALLED PER TIMCO REO G14217, RSDR UALA2011120606702Oxygen Mask · defectiveOXYGEN MASK DEFECTIVE AT3.(1=CAPT,2=1ST OFF,3=1ST OBS). CREW COMMENTS: F/O'S O2 MASK VERY HARD TO HEAR. SWITCHED WITH OBS MASK, NO HELP. BOTH TESTED OKAY IN OBS POSITION. REPLACED OXYGEN MASK PER AMM.SDR UALA2011120606703Floorbeam · corrodedFLOORBEAM CORRODED STA 324, RBL 45-RBL 62, T-CAP CORRODED. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED SECTION OF T-CAP AND FABRICATED A NEW T-CAP, REPAIR ANGLES AND STRAPS AND INSTALLED AT BS 324 AND RBL 45- RBL 62 PER REO G14229, REV B AND UAL EVA 81564 ON SDR UALA2011120606704Switch · faultyRAT SWITCH NEEDS SHEAR WIRE. SAFETIED RAT SWITCH ON FLIGHT STATION OVERHEAD P11 PANEL PER MM ON NON ROUTINE 27209.SDR UALA2011120606705Light · inoperativeAFT CABIN EMERGENCY LIGHT MOUNTED ON FLOOR INOP. REMOVED AND REPLACED AFT CABIN EMERGENCY FLOOR LIGHT PER MM AND OPS CHECK GOOD PER MM ON NON ROUTINE.SDR UALA2011120606707Connector · looseEMERGENCY FLOOR LIGHTING INOP FROM DOOR 2L TO EXIT ROWS. SECURED LIGHT STRIP. SECURED CONNECTOR ON POWER SUPPLY, ALL CHECKS OK NOW.SDR UALA2011120506686Fseu · faultyFLAP-SLAT ELEC ON STATUS PAGE WON'T CLEAR. FSEU FAULTED NR 2 M10342. REPLACED UNIT PER MM. GROUND CHECKED NORMAL.SDR UALA2011120506657Feeder Cable · inoperativeINOP EEL LIGHTS AT MID TO AFT CABIN. FOUND FEEDER CABLE FROM THE WALL CUT PROBABLY DURING CARPET INSTALLATION. REPLACED CABLE, OP CHECKS GOOD.SDR UALA2011120506664Ecu · malfunctionedLOW PNEUMATIC PRESSURE 5 PSI. UNABLE TO REVIVE AIR PRESSURE. ONLY 5PSI. NEED GROUND START. REPLACED ECU PER MM SINCE IT WOULDN'T RESET AFTER LAMP TEST. REPLACED FLOW SENSE MODULE PER MM AS PER FIM AND WIRING CHECKS WERE GOOD.SDR UALA2011120606688Skin · damagedAIRCRAFT DAMAGE FWD OF L2 DOOR 6 FT FWD OF DOOR. A HOLE THROUGH FUSELAGE APPROX 6 INCHES LONG BY 1 INCH WIDE. MAJOR REPAIR ACCOMPLISHED. DAMAGE IS AT STATION 627 JUST BELOW STRINGER 17L. REMOVED EXISTING REPAIR DOUBLER & CUT OUT DAMAGED SKIN.SDR UALA2011120506652Shear Web · corrodedMAIN CABIN SHEAR WEB DOUBLER, AFT PRESSURE DECK PLATE CORRODED AT BS 1680, RBL 58. MAJOR REPAIR ACCOMPLISHED. REMOVED CORRODED DOUBLER BETWEEN RBL 45 TO RBL 52 AND FABRICATED AND INSTALLED A NEW REPAIR DOUBLER PER REO G14236, REV C AND UAL EVA 81559 ON NON RSDR UALA2011120506653Splice · corrodedMAIN CABIN SPLICE IS CORRODED AT BS 365 AND RBL 45. MAJOR REPAIR ACCOMPLISHED. REMOVED SPLICE AND FABRICATED A NEW REPAIR SPLICE AND SHIM PER REO G14273, REV A, AND UAL EVA 81560 AND INSTALLED ON NON ROUTINE 27862.SDR UALA2011120506654Floorbeam · corrodedMAIN CABIN FLOORBEAM T-CAP HAS EXFOLIATION CORROSION BS 1640, RBL 58.2. MAJOR REPAIR ACCOMPLISHED. T-CAP CORROSION WAS FOUND TO BE OUT OF LIMITS PER SRM. REMOVED DAMAGED SECTION OF FLOORBEAM AND FABRICATED AND INSTALLED REPAIR CHORD, ANGLES, AND STRAPS PER SDR UALA2011120506655Floorbeam · corrodedFLOORBEAM CORRODED AT BS 365 BL 0 - RBL 62, T-CAP. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED SECTION OF T-CAP AND FABRICATED A NEW REPAIR T-CAP AND SPLICE ANGLES AND INSTALLED PER SRM, REPAIR 3 ON NON ROUTINE 27775.SDR UALA2011120506656Stringer Splice · gougedMAIN CABIN - FUSELAGE STRINGER SPLICE GOUGED IN INNER U-CHANNEL RADIUS'S, UPPER AND LOWER, AT BS 783 AND STRINGER 16L SPLICE. MAJOR REPAIR ACCOMPLISHED: REMOVED STRINGER SPLICE AND ATTACH ANGLE, LOCATED AND DRILLED NEW STRINGER SPLICE, P/N 143N3800U13, AND ISDR UALA2011120506685Fseu · faultyFLAP-SLAT ON STATUS PAGE WON'T CLEAR. FSEU 1 & 3 BITE SHOWS NO FAULTS. FSEU 2 FAULTS AUTOSLAT CIRCUIT MESSAGE 201. REPLACE FSEU 2 & TESTED PER MM. TESTED OKAY.SDR UALA2011120506676Module · failedNO SYS FAIL LIGHT DURING FIRE LIGHT CHECK. REPLACED MASTER MODULE AND CIRCUIT BOARD FOR FAIL SWITCH ON FIRE OVERHEAT PANEL, CHECKED OKAY.SDR UALA2011120206635Floorbeam · corrodedFOUND EVIDENCE OF CORROSION ON FLOORBEAM ABOUT 6 INCHES FROM GALLEY WALL. ACCOMPLISHED CORROSION REMOVAL & CORROSION PREVENTION IAW MM.SDR UALA2011113006579Repair · debondedRUDDER LEFT UPPER SURFACE OLD REPAIR IS DISBONDING AND BREAKING OFF. AREA APPROX 4 INCHES BY 5 INCHES. COMPLIED WITH EVA-81567 AND MADE TEMP REPAIR WITH SPEEDTAPE.REFER TO SM-09-13-25-01-JD FOR PERMANENT REPAIR.SDR UALA2011120106614Placard · out of positionF/A REPORTED, UNABLE TO ARM L2 DOOR. FOUND GIRT BAR ARMING HANDLE RUBBING ON ARMING PLACARD. ADJUSTED PLACARD ASSY CHECKS OKAY PER CREW.SDR UALA2011120206626Plate · crackedR2 DOOR UPPER HINGE RECESS AREA PLATE CRACKED .387 INCH. DAMAGE WAS BLENDED OUT. CRACK IS NO LONGER PRESENT. MAJOR REPAIR PER MM 52-11-00.SDR UALA2011113006567Light · missingEEL LIGHTS MISSING ON SEATS 6B AND 10B AND 8B LOOSE. REPLACED MISSING LIGHTS AND SECURED LOOSE ONE, OPS CHECK GOOD.SDR UALA2011112906556Valve · malfunctionedCB POPPED Q27 R HI STG SW OVER. REPLACED RIGHT ENG HIGH STAGE PILOT & SERVICE TIP.SDR UALA2011112906561Lamp · inoperativeFIRE WARNING LIGHT DOES NOT ILLUMINATE ON LEFT ENGINE FUEL CONTROL SWITCH DURING TEST. RELAMPED LEFT ENG FUEL CONTROL SWITCH. FIRE TEST NORMAL.SDR UALA2011112906562Unknown · unknownGEAR DOORS EICAS AND LIGHT ABOVE HANDLE. CREW REPORTED GEAR HANDLE PLACED IN UP POSITION PER QRH PROCEDURE,VIBRATION AND NOISE WENT AWAY AND "DOORS" LIGHT AND EICAS EXTINGUISHED. CREW COULD NOT PINPOINT AREA OF VIBE-NOISE, BUT SUSPECT COMING FROM MAINS. PERSDR UALA2011112906557D-Ring · out of adjustRAFT SLIDE SURV KIT ATTACH 'D' RING 2L NEEDS ADJ REPAIRED "D" RING ATTACH POINT PER MM.SDR UALA2011112906558Audio Panel · malfunctionedCREW REPORT: ATC REPORTED STUCK MIC IN FLIGHT UNABLE TO COMMUNICATE W/ATC CAUSE UNDETERMINED ALL RADIOS. SAMC TEXT: F-O WAS USING THE RADIOS. COULD NOT XMIT OR RCV UNTIL OBS AUDIO PANEL WAS USED. SWAPPED WITH OBSERVERS AUDIO SEL PANEL, ALL VHF OPS NORMAL.SDR UALA2011112706513Wire · damagedLANDING GEAR ALTERNATE EXTENTION CIRCUIT BREAKER POPPED ON P6-1. REPAIRED DAMAGED WIRE BY SPLICE SP1544 REF WDM32-12-12, WIRE LOCATED IN LEFT MAIN GEAR WHEEL WELL NEAR GEAR DOOR CLOSED SWITCH.SDR UALA2011112706487Wire · brokenLEFT HYD SYSTEM PRESSURE LIGHT AND EICAS MESSAGE NOT DISPLAYED WITH NO LEFT HYD PRESSURE. REPAIRED BROKEN WIRE TO LOCAL GROUND AT HYD PRESSURE SWITCH S27. CHECKED OKAY.SDR UALA2011112706516Antenna · failedTCAS TEST FAILED. REPLACED TCAS LOWER ANTENNA PER MM, TCAS OPS CHECKED OKAY.SDR UALA2011112706492Gate · crackedMAIN CABIN L2 DOOR LOWER GATE IS CRACKED. REMOVED LOWER GATE & SEAL RETAINERS, WELD REPAIRED GATE AND REINSTALLED ON NON ROUTINE 27474.SDR UALA2011112706493Skin · crackedL4 DOOR INTERNAL SKIN HAS A CRACK 9 INCHES FROM FWD EDGE OF DOOR. MAJOR REPAIR ACCOMPLISHED. BLENDED OUT DAMAGE PER SRM AND FOUND TO BE OUT OF LIMITS. FORMED REPAIR DOUBLER AND SHIM AND INSTALLED PER SRM ON NON ROUTINE 2 7569.SDR UALA2011112706494Gate · corrodedL2 DOOR LOWER GATE IS CORRODED ON BOTTOM EDGE. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION BY BEAD BLASTING PER SM-09-13-25-10-JD AND ACCOMPLISHED ALL FINAL CORROSION PREVENTATIVE TREATEMENT, PRIME AND TOP COATED ON NON ROUTINE 27578.SDR UALA2011112706495Skin · crackedR4 DOOR INTERNAL SKIN CRACKED JUST ABOVE LOWER HINGE ARM. MAJOR REPAIR ACCOMPLISHED. BLENDED OUT DAMAGE PER SRM, FOUND TO BE OUT OF LIMITS. FORMED REPAIR DOUBLER AND FILLER PER SRM AND ALODINED AND PRIMED AND INSTALLED PER SRM ON ROUTINE 27592.
Back to Pratt & Whitney PW2037