Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011111406212Power Cable · burnedPC POWER CABLE FROM SIDEWALL TO SEAT 1CD BURNT AT SEAT CONNECTION, BREAKERS POPPED AT P37 PNL. WALL TO SEAT CABLE AND JUNCTION BOX DAMAGED. NIS SEA. INOPED PER MEL. NOTE: SEATS DO NOT HAVE PC JACKS INSTALLED THIS AC. BREAKERS PULLED AND CAPPED. REPLACED SDR UALA2011111406233B-Nut · strippedB-NUT TO FUEL BYPASS ELBOW STRIPPED. OIL LINE GOES TO SCAVENGE PUMP (NR 2 ENG). INSTALLED NEW OIL LINE FROM SCAVENGE OIL PUMP TO FUEL OIL HEAT EXCHANGER, NR 2 ENG.SDR UALA2011111406193Floorbeam · corrodedCORROSION ON FLOORBEAM AT STA 1640 BL 0 - RBL 62. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION & FOUND BLEND OUT OF SRM LIMITS. CUT OUT DAMAGED UPPER CHORD SECTION OF FLOORBEAM FROM LBL 10 TO RIGHT END OF FLOORBEAM REF PEMCO EA PD57-53-231 & SRM 53-00-51 FISDR UALA2011111406199Pressure Deck · corrodedCORROSION ON PRESSURE DECK AT STA 1715 - 1720 AT RBL 20-62. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION & FOUND BLEND OUT OF LIMITS OF SRM. REMOVED FASTENERS IN REPAIR AREA & ACP NDT OF OPEN HOLES. NO CRACKS FOUND. FABRICATED & INSTALLED EXTERNAL DOUBLERSDR UALA2011111406200Floorbeam · corrodedAFT DECK AREA AT STA 1681 FLOORBEAM AT RBL 32 HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION & FOUND BLEND OUT OF LIMITS OF SRM. CUT OUT DAMAGED AREA & ACP NDT OF OF OPEN HOLES COMMON TO REPAIR AREA FOR CRACKS. NONE FOUND. ACP INSURANCE CUT. SDR UALA2011111406185Unknown · noisyVERY HIGH COCKPIT NOISE LEVELS FROM PACK-RECIRC FAN. ACP'D CHECK OF RECIC FANS AND FILTERS. FANS AND FILTERS ARE CLEAN. ACP'D FLIGHT DECK GROUND NOISE LEVEL CHECK. FLIGHT DECK NOISE WAS BELOW LIMITS OF 70.5 DB.SDR UALA2011111406191Generator · inoperativeCREW REPORTS APU GEN INOPERATIVE. REPLACED APU GENERATOR PER MM. ACCOMPLISHED SUCCESSFUL OPERATIONAL CHECK.SDR UALA2011111106159Slide · deployedSLIDE NEEDS TO BE REPLACED DUE TO DEPLOYMENT. INSTALLED SLIDE 4L UP TO STEP 'F' ON PAGE 415 OF MM.SDR UALA2011111106160Oxygen Bottle · lowCREW COMMENTS: USED OXYGEN BOTTLE LOCATED AT 1A. SERVICE BOTTLES TO FULL. 3 EACH BOTTLES USED 2 FWD AND 1 AFT.SDR UALA2011111406178Skin · damagedDEEP BLEND OUTS FOUND ON CROWN AT STR 2L, STA 1418. ITEM REPAIRED IAW ECRA 53 60-01167, EVA 81468. EXT SKIN DOUBLER REPAIR INSTALLED AT STA 1418, STR 2L PER SCAL ECRA 5360-01167 AND EVA 81468. SKIN REPAIR MUST RECEIVE NEW FAA FORM 8100-9 SHOWING COMPLIANCE SDR UALA2011111406179Skin · damagedSKIN HAS PREVIOUS DEEP BLEND OUT FROM LIGHTNING STRIKE WITH COUNTER SUNK RIVET IN CENTER OF BLEND, STA 240, 3' OTBD OF LT SIDE ACCESSORY DOOR CUTOUT (E&E DOOR). MAJOR REPAIR ACCOMPLISHED. REPAIR DOUBLER INSTALLED PER SCAL ECRA 5330-04161, EVA 81452, AND NR 9SDR UALA2011111406180Skin · damagedDEEP BLEND OUT ON CROWN STA 1280 TO 1300, STR 2L. MAJOR REPAIR ACCOMPLISHED. REPAIR DOUBLER INSTALLED IAW SCAL ECRA 5360-01166, EVA 81469, AND SCAL NR 9951619.SDR UALA2011111406182Pressure Deck · corrodedCORROSION ON PRESSURE DECK FROM 1681-1686 LBL 18 - RBL 62. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION FROM AFT DECK PLATE P/N 146N5318-10 AND FOUND BLEND OUT OF LIMITS OF SRM. ACP NDT FOR CRACKS & PERFORMED INSURANCE CUT ALL PER PEMCO EA57-53-228. ACP NDSDR UALA2011111406213Skin · damagedBS 1420-1446 FUSELAGE SKIN REPAIR INCORPORATING AIRFONE ANTENNA DOUBLER REPAIR BETWEEN STRINGERS S-29L & S-30 RECEIVED FIRST STAGE APPROVAL FOR STATIC STRENGTH ONLY. THIS REPAIR WAS ACP PER EA PD57-53-229 & UA-EVA 81494 ON N-R 3550N00031 WITHOUT DEVIATION. RSDR UALA2011111106161Bulb · missingMISSING TWO 1864 BULBS FROM SPARE BULB KIT. NO TIME. REPLACED BULBS.SDR UALA2011111106168Windshield · delaminatedCAPTAIN'S WINDSHIELD'S VISIBILITY IS AFFECTED BY DEFECTS, REPLACE FIRST AVAILABLE. CREW COMMENTS: U SHAPED DELAMINATION BUBBLE WINDOW 1L LOWER RT CORNER. REPLACED CAPT'S WINDSHIELD PER MM.SDR UALA2011111106169Sealant · damagedFUEL LEAKING FROM LEFT WING OTBD FLAP INBD TRACK FAIRING. ONE DROP EVERY 90 SECONDS. FOUND FWD OUTBOARD BOLT ON LOWER ATTACH FITTING LEAKING. RESEALED AT 0600 ON 11-11-11.SDR UALA2011111106167Control Valve · faultyCREW REPORTED OIL SMELL. ACP SMOKE OR FUMES PER FIM. REMOVED ENGINE AND AIR CONDITIONING DISTRIBUTION DUCTS FOR PRESENCE OF OIL. NO INDICATION OF OIL INSIDE OF THE DUCTS. NEED TO PERFORM ENG RUN FOR BLEED PRESS SPLIT. BLEED SHIFT OCCURS ON BOTH ENGS AT 80% NSDR UALA2011111106154Floorbeam · corrodedCABIN FLOORBEAM STA 324, RBL 44 IS CORRODED. MAJOR REPAIR ACCOMPLISHED: REPLACED UPPER T-CHORD SECTION AT STA 324 BETWEEN LBL 14 TO RT FRAME JOINT PER SCAL ECRA 5310-05412 AND EVA 81446.SDR UALA2011111106155Floorbeam · damagedCABIN FLOORBEAM UPPER CAP STA 365 FROM BL 0 TO RBL 63. (P54-221-011). MAJOR REPAIR ACCOMPLISHED: ITEM REPAIRED IAW SCAL EC RA 5310-05413, EVA81445, AND SCAL NR 9952160.SDR UALA2011111106156Floorbeam · corrodedCABIN FLOORBEAM STA 1640 LBL 33 TO RBL 58 HAS CORROSION ON UPPER CAP. ITEM REPAIRED IAW SCAL EC RA 5310-05411, EVA 81444, AND CAL NR 9952002.SDR UALA2011111006142Wire · exposedCAPTAIN'S HAND MIC HAS BARE WIRES EXPOSED. REPLACED MIC, OPS OKAY.SDR UALA2011111106152Light · inoperativeLEFT OVERWING EMERGENCY ESCAPE SLIDE LIGHT DID NOT COME ON DURING EEL BATTERY DRAIN TEST. LEFT OFF WING SLIDE LIGHT L568 WAS RELAMPED. WORK ACP PER AMM. OPS CHECKS OKAY.SDR UALA2011111106153Shim · out of adjustLEFT AFT OVERWING ESCAPE HATCH - UNABLE TO OPEN FROM THE OUTSIDE HANDLE - DIFFICULT FROM THE INSIDE. ADJUSTED LT AFT OVERWING ESCAPE HATCH SHIM PER AMM, ON S-CAL NR 9954366.SDR UALA2011111106174Girt Bar · dirtyDOOR 3L WILL NOT ARM. CLN'ED GIRT BAR AREA. ARMED AND DISARMED DOOR. OPS CHECKED NORMAL.SDR UALA2011111106177Valve · faultyFIRST START ATTEMPT NORMAL FF BUT NO LIGHT OFF. REPLACED LEFT WING SPAR VALVE. OPERATED VALVE SEVERAL TIMES, NORMAL OP'S.SDR UALA2011110906127Floorbeam · corrodedCORROSION ON FLOORBEAM AT STA 323 RBL 40.5 AND 60.0. MAJOR REPAIR ACCOMPLISHED: CORROSION AT STA 324 RBL 40.5 AND 60 REPAIRED PER INSTRUCTIONS ON EA PD57-53-225 AND UA EVA 81467 WITHOUT DEVIATION. CF CREATED FOR DTA.SDR UALA2011111006136Light · inoperativeSEVERAL LIGHTS INOP ENG 2 FIRE HANDLE. RELAMPED ENG 2 FIRE HANDLE AND OP CHECKED.SDR UALA2011111006149Link · out of adjustCAPTAIN'S SLIDING WINDOW WON'T UNLOCK. ADJUSTED LINK ARM.SDR UALA2011111106166Structure · crackedFERRY FROM SEA TO SFO FOR REPAIR BY SFO. DOOR 2R UPPER HINGE CUTOUT IS CRACKED APPROXIMATELY 0.28". ACP WALK AROUND OF ACFT.
MED 2R. UPPER HINGE CUT OUT CRACK APPROX 9-32 OF AND INCH. MAJOR REPAIR-DOUBLER INSTALLED PER SRM 52-10-02 REPAIR 1 AND UA-EVA-814SDR UALA2011110906103Idg · lack of lubeRIGHT GEN TRIPPED OFF ON T/O ROLL ABORTED T/O BELOW 60 KNOTS. REPLACED NR 2 ENG IDG PER MM. RAN 5 MINS, NO LEAKS. OPERATED OK UNDER LOAD. FOUND IDG LOW ON OIL ON REMOVAL. BPPC BITE CHECK SHOWS LOW IDG OIL. IDG TRIP. LOW FREQS. CALLED LM TO HAVE IDG OILSDR UALA2011110906130Pca · leakingRT ELEVATOR O/B PCA SHOWS EVIDENCE OF LEAKAGE. REMOVED & REPLACED RT ELEVATOR O/B PCA IAW B757 AMM, OPS CHECK GOOD. NO LEAKS NOTED.SDR UALA2011110906131Floorbeam · damagedDUE TO A MAJOR REPAIR OF THE BS 324 FLOORBEAM UPPER CHORD DURING HMV 3 VISIT, AN INITIAL FIRST STAGE APPROVAL WAS RECEIVED. THIS REPAIR MUST RECEIVE A NEW 8100-9 SHOWING COMPLAINCE TO 14CFR 25.571 AND 26.43(D) AND DTA INCORPORATED INTO THE AIRCRAFT MAINTENANCSDR UALA2011110806093Selector · faultyNOISE IN CABIN. REPLACED-: FLIGHT DECK ZONE TEMPERATURE SELECTOR & ZONE TEMPERATURE CONTROLLER IAW MM. REPLACED FLIGHT DECK ZONE TEMPERATURE SENSOR IAW MM FLT DECK NOISE CHECKED GOOD. DUE TO HISTORY OF LOUD COCKPIT NOISES AND UNCONTROLLABLE COCKPIT TEMPERATSDR UALA2011110806080Connector · not seatedOVERHEAD PRESSURIZATION IND PNL INTEG LIGHTING IS 75 PCT INOP DIFF NEEDLE AND DIAL NOT ILLUM. COMPLIED WITH MEL. RESEATED CONNECTORS ON OVERHEAD PRESSURIZATION PANEL LIGHTING, OPS CHECKS GOOD.SDR UALA2011110906102Oil System · leakingOIL DRIPPING FROM BOTH ENGINES. INSP'D BOTH ENG. FOUND OIL DRIPS FROM ACCUMULATED OIL ON BOTTOM OF COWL AROUND BREATHER HOLE. NO ACTIVE OIL LEAKS FROM DRAINS.SDR UALA2011110806076Wire · shortedLEFT ENG FUEL FILTER EICAS, FLIGHT DIVERTED. FOUND WIRE W3394-1019-18 SHORTED APPOX 10 INCHES FROM CONNECTOR D42036P PIN 4. REPAIRED WIRE PER GN-MM. WIRE HAS INSULATION DAMAGE ONLY. GRD CHECK GOOD. NO SHORT TO SHIELD, AFTER REPAIR.SDR UALA2011110906101Receptacle · dirtyLEFT MAIN FUEL QTY BLANK AT LAX. TROUBLESHOOTING NEW FUEL QTY PROCESSOR, NO HELP. NEW FUEL QTY PROCESSOR INSTALLED BY MECHANIC. NO HELP. PROCESSOR SHOWS PRESENT FAULTS (LM HI Z SHIELD OPEN AT SPAR G01). ACP TROUBLESHOOTING PER MM. RANG OUT WIRES FROM FUESDR UALA2011110906104Fcu · leakingCREW REPORT: HEAVY FUEL LEAK FROM APU UNDERSIDE AREA OF AIRCRAFT. FOUND FUEL LEAK AT THE APU FCU WITH APU RUNNING, WITH APU INOP FUEL LEAK STOPPED. WILL INOP THE APU PER MEL 4911A. WITH APU INOP THERE IS NO FUEL SUPPLIED TO APU. REVIEWED WITH SAMC-EMC. SSDR UALA2011110906118Lanyard · looseUNABLE TO ARM 4R. SECURED LOOSE GIRT BAR CORD.SDR UALA2011110806081Skin · dentedDOOR 4 RIGHT OUTER SKIN HAS A SMALL DENT AT THE FWD EDGE ADJACENT TO THE 3RD DOOR STOP FROM THE BOTTOM. MEASURED DENT AND FOUND TO BE WITHIN LIMITS IAW B757 SRM. NDT HFEC PERFORMED ON DENT AREA IAW B757 NDTM PART 6 AND FOUND NO CRACKS. TREATED, PRIMED AND PSDR UALA2011110706044Light · inoperativeDOOR 4L EXT EMERGENCY EXIT LIGHT INOP. RELAMPED PER MM.SDR UALA2011110706045Charger · faultyMAIN BATTERY CHARGER STATUS MESSAGE WILL NOT CLEAR. BATTERY CHARGER, OP CHECKS OKAY.SDR UALA2011110706073Plug · faultyWINDOW R2 MISSING WINDOW HEAT WIRE CAPS. FOUND PLUG ASSY WILL NOT ACCEPT CAP. REPLACED 566-1610 PLUG ASSY, OPS CHECK GOOD.SDR UALA2011110706021Shutoff Valve · faultyBOTH DUCT PSI IN DESCENT ONLY 10 PSI. POSSIBLE HI STAGE VLV ISSUE. RAN BOTH ENGINES WITH NO PACKS ON 10 PSI, WITH RT ENGINE ONLY WITH PACKS 5 PSI. WITH LT ENGINE PACKS 12 PSI. REPLACED PILOT REG AND HI STAGE SHUTOFF VALVE PER MM, OP'S CHECK GOOD.SDR UALA2011110706074Window · obstructedCAPT SLIDING WINDOW LOCK MECHANISM BOUND UP. HIGH PITCHED SQUEAL EMANATING FROM AFT PART OF F-O SLIDING WINDOW. LUBED OVER CENTER MECHANISM. CLN'D TRACK, ALSO CLEANED WINDOW SEAL AND AREA. REMOVED SOME HARD STUFF FROM SEAL. ADJUSTED CAPT NR 2 WINDOW PER MSDR UALA2011110706023Wire · shortedDOOR 1L & 1R - EXIT IDENTIFIER SIGNS DO NOT ILLUMINATE DURING TEST OF INTERIOR EMERGENCY LIGHTS. BY- 054816 :TRIED NEW POWER SUPPLY M731 AND INVERTER M10822 NO HELP. SEAT 1AB AND GALLEY AISLE LIGHT ALSO INOP. REF WDM 33-51-21 PG 5A SH1. CONT OF AMIS ITEM SDR UALA2011110706025Guard · out of adjustEMERGENCY EXIT LIGHT SWITCH IN COCKPIT IS VERY TOUCHY, NEEDS ADJUSTMENT. ADJUSTED GUARD ASSY. SYSTEM OP CHECK OK.SDR UALA2011110706009Connector · out of positionEMERGENCY EQUIPMENT LIGHTS AT LT AISLE SEATS 1AB, 5AB, 6AB, AND 7AB DO NOT ILLUMINATE DURING TEST OF INTERIOR EMERGENCY LIGHTS. SEAT 1AB IS COVERED BY SMC 8. RESET CONNECTOR AT M732, SEATS 5, 6, AND 7 NOW OK.SDR UALA2011110706067Anti-Ice Valve · defectiveLEFT ENG EPR FLUCTUATES ABRUPTLY WHEN TURNING ANTI-ICE ON AND OFF. REPLACED NR 1 ENGINE COWL ANTI-ICE VALVE AS PER MM. RAN ENG, OPS CHECK NORMAL.
Back to Pratt & Whitney PW2037