Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011092705214Light · inoperativeDOOR ARMED LIGHT INOPERATIVE AT DOOR 3L. NOTICED DURING CLIMBOUT. SECURED DOOR ARMED LIGHT ASSY, OPS GOOD.SDR UALA2011092705216Flap System · malfunctionedRECEIVED A TRAILING EDGE FLAP DISAGREE EICAS MESSAGE. MESSAGE CAME ON BETWEEN FLAPS 20 & 25. BITE CHECKED FSEU NR1 SHOWED INTERMITTENT FLAP FAULT. CLEARED FAULT, OPERATED FLAPS SEVERAL TIMES ALL CHECKED NORMAL.SDR UALA2011092705218Warning Light · false activationRIGHT AFT ENTRY DOOR LIGHT INTERMITTENT. ENTRY DOOR 4R EICAS MESSAGE AND OVERHEAD LIGHT ON WITH DOOR CLOSED. VERIFIED DOOR IS CLOSED AND DOOR SLIDE ARMS PROPERLY PERSDR UALA2011092605171Light · dirtyEMERGENCY LIGHTING STRIP RAISED ABOVE IT'S RECESS AT 11ABC. REMOVED DEBRIS FROM UNDER EMERGENCY LIGHT STRIP.SDR UALA2011092605183Light · inoperativeDOOR 4R ARM LIGHT WILL NOT COME WHEN ARMED. RIGHT AFT DOOR SLIDE LIGHT FLICKERING. INTERNAL CONTACT ON SWITCH IS STICKING ON DOOR ESCAPE SLIDE GIRT BAR ENGAGEMENT LIGHT ON DOOR 4R. CLEANED & LUBED DOOR 4R GIRT BAR MECHANISM, LIGHT WORKS NORMAL. STILL INOPERSDR UALA2011092605182Light · inoperativeL2 DOOR LOWER EMERGENCY EXIT SIGN INOPERATIVE. REPLACED EMERGENCY LIGHT ASSY, OPS CHECKED GOOD.SDR UALA2011092705213Control Panel · faultyLEFT VHF COMMS AUDIO RECEPTION POOR AT 1 POSTITION. RECEPTION OK AT OTHER CREW POSITIONS. (01=CAPT POS'N, 02=1ST OFF POS'N, 03=OBS POS'N). CAPT'S SIDE TONE INEXPLICABLY INTERMITTENT ON VHF 1. REPLACED CAPT AUDIO CONTROL PANEL. CHECKED OKAY.SDR UALA2011092605193Door · damagedPASSENGER ENTRY-SERVICE DOOR R1 FWD NOISE FROM AIR LEAK.FOUND PREVIOUS REPAIR COMPLETELY BLOWN OUT (SEALANT NOT CURED). CLEANED AREA AND REAPPLIED SEALANT. AFTER PRESSURE CHECKED DOOR. STILL LEAKS. CHECKED DOOR STOPS. ALL GOOD. REMOVED REN FROM FWD AND ASDR UALA2011092605205Actuator · failedRIGHT FUEL SPAR VALVE EICAS MESSAGE DURING ENGINE START ATTEMPT. CREW TRIED TO CYCLE CIRCUIT BREAKER E02, FUEL VALVES RIGHT SPAR. BREAKER WOULD NOT STAY CLOSED. REPLACED RT SPAR VALVE ACTUATOR, OPS CHECKED OKAY.SDR UALA2011092605169Stringer · corrodedCORROSION ON STRINGER 28R BETWEEN STA 1372 -1378. MAJOR REPAIR ACCOMPLISHED. REPLACED STRINGER SPLICE PER SRM ON NR 3175N00238.SDR UALA2011092605165Slide · dislodgedDOOR 1R SLIDE PACK FELL DOWN WHEN DOOR WAS CLOSED. REINSTALLED SLIDE AND OPS CHECKED OPERATION. ALL CHECKED NORMAL.SDR UALA2011092605170Heating Element · failedAFTER PUSHBACK AND ENGINE START HAD EICAS MESSAGE: 'CAPT PITOT' ALSO HAD DISCRETE LIGHT. REPLACED CAPT PITOT PROBE AFTER CONFIRMING PROBE HEATING ELEMENT OHMED OUT WITH BAD ELEMENT IAW MM34-11-01 PG 401 & MM 34-11-01 PG 501. STARTED NR 2 ENGINE AND CONFIRMEDSDR UALA2011092605201Pilot Valve · inoperativeAT LOW POWER SETTINGS DUCT PRESSURE DROPS TO AROUND 5 PSI, NOT ENOUGH AIR FOR COOLING. RAN BOTH ENGINES. NR1 PERFORMED NORMALLY BUT NR 2 PRODUCES ONLY 5 PSI AS NOTED. NR 2 BLEED TURNED OFF AT SWITCH AND IS CONSIDERED INOPERATIVE. REPLACED HIGH STAGE PILOT.SDR UALA2011092605168Pin · installedFOUND AT DOOR 4R SLIDE BOTTLE PIN INSTALLED AND SHOWING IN BOTTLE WINDOW. THE PIN NEEDS TO BE REMOVED FROM DOOR 4R, PLUS ALL DOORS (1L&R, 2L&R, 4L) REQUIRE A CHECK TO VERIFY SAFETY PINS ARE 'NOT' INSTALLED.SDR UALA2011092605161Pressure Deck · corrodedCORROSION ON PRESSURE DECK AT PREVIOUS REPAIR STA 1680, RBL 10 - 30. MAJOR REPAIR ACCOMPLISHED. REPLACED DOUBLER PER EA PD57-53-191 ON NR 3175N00177.SDR UALA2011092605163Floor Support · corrodedMAIN CABIN STA 1020 - 1040 RBL 65 FLOOR SUPPORT CORRODED. MAJOR REPAIR ACCOMPLISHED. REPLACED CREASE BEAM INBD CHORD, SPLICE STRAP AND SPLICE CHANNEL PER PEMCO EA PD57-53-203 ON PEMCO NR 3175N00460.SDR UALA2011092305156Floorbeam · corrodedFLOORBEAM AT BS 345 CORRODED FROM BL 0 - RBL 45. MAJOR REPAIR ACCOMPLISHED REPLACED TEE'S, ANGLES, AND STRAPS PER SRM.SDR UALA2011092305157Floorbeam · corrodedFLOORBEAM TEE CORRODED AT BS 1661 FROM BL 0 TO LBL15. REPLACED TEE'S AND STRAPS PER SRM.SDR UALA2011092605162Frame · dentedAFT PIT BELT FRAME DENTED JUST OTBD OF LEFT TRANSITION PANEL, AT BS 1420. REMOVED & INSTALLED NEW BELT FRAME FROM STR 24L TO 27L.SDR UALA2011092305132Terminal · damagedFOUND CAPTS WINDOW HEAT TERMINAL J1 WILL NOT REACH TORQUE. REMOVED AND REPLACED WINDSHIELD REF MM.SDR UALA2011092305144Placard · missingSEAT 34C 'LIFE VEST UNDER SEAT' PLACARD MISSING. INSTALLED ON TRAY TABLE. INSTALLED CORRECT PLACARD.SDR UALA2011092305158Skin · gougedSMALL HALF INCH BLEMISH AND POSSIBLE CRACK ON RIGHT NACELLE AFT CORE COWL 10 O'CLOCK POSITION. .375L X .0310D X .5W. PIXS POSTED. OUT OF SRM LIMITS. REPAIRED BLEMISH AT 10 O'CLOCK POSITION NO CRACKS FOUND. CHECKED IAW SRM.SDR UALA2011092605159Circuit Card · faultyAURAL WARNING WILL COME ON WHEN STANDBY SWITCH TURNED OFF. TRIED SWAPPING POWER SUPPLY AND TRIED NEW LANDING CONFIG WARNING MODULE M983, NO HELP. TAKEOFF CONFIG WARNING TEST FAILED ON WARN ELEX-A. REPLACED M620 TAKE OFF CONFIGURATION CARD. CHECKED OKAY.SDR UALA2011092605160Blades · nickedON LEFT ENGINE FAN, FOUND NICKS ON SEVERAL BLADES. CHECKED FOUND 3 BLADES ON LEADING OF BLADE ON NUMBER TWO INDEX AREA. ACCOMPLISHED EDDY CURRENT INSPECTION OF BLENDED FAN BLADES ON NR 1 ENG PER MM. NO CRACKS FOUND. ACCOMPLISHED FINAL BLEND OF BLADES.SDR UALA2011092605179Blades · nickedLEFT ENGINE FOUND NICKS ON SEVERAL FAN BLADES. CHECKED AND FOUND 3 BLADES ON LEADING OF BLADE ON NR 2 INDEX AREA. BLENDED BLADES LEFT ENGINE.SDR UALA2011092305155Blade · nickedLEFT ENGINE FOUND NICKS ON SEVERAL FAN BLADES. REF MM 72-31-02 PAGE 612. BLENDED BLADES LEFT ENGINE REF MM.SDR UALA2011092605164Unknown · unknownCREW REPORTS ON TAKEOFF ROLL AT 130 KIAS (ALL 3 GEAR STILL ON THE GROUND), CREW FELT A MOMENTARY JOLT-YAW-LATERAL MOVEMENT NOSE LEFT. CREW COUNTERED WITH SLIGHT RT RUDDER. CREW DID NOT FEEL ANY MOVEMENT IN RUDDER PEDALS PRIOR TO COUNTERING THE YAW. RUNWAY WSDR UALA2011092605188Circuit Breaker · trippedACFT WILL NOT TAKE FUEL, FOUND C-B OUT A9 FUELING VALVES ON THE P34 PANEL MAIN E&E BAY. FLT DECK. P6-1 PANEL C-B E6 FOR FUELING VALVES POPPED.SDR UALA2011092205117Seal · leakingAT GATE, FOUND NLG STRUT LEAKING OIL & LOW, CLEANED, TOWED ACFT TO HANGAR, NLG STRUT CONTINUES TO LEAK OIL. REPLACED NLG STRUT SEALS PER MM. FOUND LEAKING TO CEASE WITH NO DECREASE TO DIMENSION X. CHECKED EXTENSION AND FOUND IT 1.5" LOW. SERVICED STRUT WITHSDR UALA2011092305130Floorbeam · corrodedFLOORBEAM CORRODED AT STA 324 RBL 38 UP TO CREASE BEAM. MAJOR REPAIR ACCOMPLISHED REPAIRED STRAPS AND REPAIRED ANGLES PER EC-RA 5310-05399. THIS IS A CAT B RPR. ALSO REF EVA 81311. N-R 9949355.SDR UALA2011092305131Floorbeam · damagedLEFT CABIN FLOORBEAM, BS 984, HAS TOOLING MARKS AT INBD END AND FWD UPPER EDGE. REPAIRED PER EC-RA 5310-05 402. DAMAGE REMOVED, TREATED AND PRIMED.SDR UALA2011092305136Skin · crackedDOOR 1R, FWD CUTOUT HAS CRACKED REVEAL, LOCATED JUST ABOVE UPPER HINGE ARM. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER RPR PER SRM. NDT AFTER DAMAGE CUTOUT REF NDT PT 6, 53-10, NO DAMAGE NOTED.SDR UALA2011092305133Lamp · inoperativeEMEGENCY LIGHT DAMAGED LEFT SIDE FROM EMERGENCY EXIT TO DOOR 2L. REPLACED AND INSTALLED NEW LAMP AND CLEAR STRIP COVER.SDR UALA2011092305134Tire · out of roundNOSE WHEEL VIBRATES AT GEAR RETRACTION. NOSE WHEELS OUT OF ROUND. REPLACED LT AND RT NOSE TIRES PER AMM.SDR UALA2011092205115Floorbeam · corrodedFLOORBEAM CORRODED AT BS 365 AT BL 0 T0 RBL 33 UNDERSIDE. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION, MATERIAL LOSS OUT OF LIMITS PER SRM. CUT OUT DAMAGE, FABRICATED AND INSTALLED REPAIR ANGLES, STRAPS AND TEE IAW SRM.SDR UALA2011092205128Control Panel · faultyNO BACKGROUND LIGHTING ON F/O'S MIC-AUDIO SELECTOR PANEL. REPLACED F/O'S AUDIO CONTROL PANEL, CHECKED OKAY.SDR UALA2011092205126Ring · out of positionUNABLE TO ARM DOOR. FOUND D-RING NOT STOWED, STOWED D-RING. CYCLED DOOR AND ARMS NORMALLY.SDR UALA2011092205127Girt Bar · dirtyTHE 1R DOOR WILL NOT ARM HANDLE IS JAMMED. FOUND DEBRIS IN GIRT AREA, ARMING OPS CHECKED GOOD.SDR UALA2011092005079Relay · faultyAPU WON'T START. REPLACED APU CRANK CONTACT OR RELAY PER MM. APU START NORMAL.SDR UALA2011092005075Light · inoperativeAFT R DOOR SLIDE LIGHT WON'T ILLUMINATE. DOOR 3R DOOR SLIDE RELAMPED.SDR UALA2011092005096Pcu · faultyLT ELEV PCU STATUS MSG. MSG WOULD NOT CLEAR, NO TIME TO TROUBLESHOOT. THE LEFT OUTBOARD PCA (RT HYD SYSTEM) FAILED FIM TEST WITH TEST BOX. NEED TO REPLACE THE LT OTBD PCA IAW MM. REPLACED LT OUTBOARD ELEV PCA PER MM, OPS CHK LEAK CHK RIG CHK OKAY.SDR UALA2011092105108Line · leakingHYD LEAK OUTBOARD LEFT WING. OPENED ALL LOWER WING ACCESS PANELS FROM OUTBOARD AILERON INBOARD. UNABLE TO FIND ANY LEAKAGE WITH SYSTEM PRESSURIZED. LEAKAGE APPEARS WITH PRESSURE OFF SYSTEM, BUT UNABLE TO DETERMINE EXACT LOCATION OF LEAK. LEAKAGE RATE DOES SDR UALA2011092005085Structure · wornNR 1 ENG PYLON HYD PRESSURE LINE FITTING STRUCTURE WORN BEYOND LIMITS. HOLE ELONGATION EXCEEDS 1.60 LIMIT. REPAIRED STRUCTURE REF SRM ON OV WU B4752X.SDR UALA2011092105107Sensor · inoperativeTHE R2 DOOR ARMED LIGHT INOPERATIVE. REPLACED R2 DOOR GIRT BAR PROXIMITY SENSORS A (S10220) AND B (S102211). R2 DOOR ARM LIGHT CHECKED OKAY.SDR UALA2011091905042Seal · unsecureF/A REPORTS AIR LEAK AT DOOR 4L DURING CLIMBOUT AND DESCENT. FOUND LWR FWD AREA OF DOOR SEAL UNEVEN. REPAIRED REF SERVICE TIP 52-09-01. ALSO FOUND DOOR SEAL OUT OF IT'S RETAINER IN SAME AREA. SECURED DOOR SEAL.SDR UALA2011092005092Pin · severedFIRE, L ENG OVHT, FIRE & OVHT LIGHTS FAILED TO ILLUMINATE DURING ENG-APU-CARGO FIRE-OVHT TEST. APPROPRIATE EICAS MSG WAS DISPLAYED. CREW COMMENTS: ENG OVHT LT NO TEST. REPLACED SEVERED PIN AT NR 2 LOCATION ON L ENG OVERHEAT LIGHT ON ENG FIRE CONTROL PANEL.SDR UALA2011092005093Unknown · odorSTRONG SMOKE SMELL IN FORWARD GALLEY. ODOR CLEARED WITH VENTILATION BUT COULD NOT REPRODUCE CONDITION. LOWERED GALLEY OVERHEAD PANELS, CHECKED ALL LIGHT BALLASTS, COFFEEMAKERS, & CHILLER UNITS FOR HEAT OR DISCREPANT CONDITIONS, NONE FOUND. OVENS COLD, NOT ASDR UALA2011092005095Cover · looseEEL STRIP LOOSE ON FLOOR AT ROW 12. REPLACED COVER.SDR UALA2011091905039Floor Support · corrodedFLOORBEAM AT BS 365 CORRODED AT BL 0. MAJOR REPAIR ACCOMPLISHED. DEFECT TEXT SHOULD READ FLOOR SUPPORT AT BS 365 AT BL 0 CORRODED . REMOVED CORROSION & FOUND MATERIAL LOSS OUT OF LIMITS. REPLACED FLOOR SUPPORT P/N 141N5191-1 FROM BS 324-430 AT BL 0.SDR UALA2011091905035Windshield · defectiveFIRST OFFICERS WINDSHIELD CONNECTOR J1 DOES NOT SIT PARALLEL TO TERMINAL. REPLACED F/O NR 1 WINDSHIELD.
Back to Pratt & Whitney PW2037