Pratt & Whitney PW4056
Service difficulty reports · 12,595
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4056' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014100792370Light · disconnectedROW 54 SEAT KJH EMER EXIT LIGHT INOPERATIVE. EMER EXIT LIGHT STRIP DISCONNECTED. SECURED EMER EXIT LIGHT STRIP. OPERATIONS CHECKED OK.SDR CALA2014100792371Light · unsecureAFT LAVATORY 116 WALL EMER EXIT LIGHT INOPERATIVE. SECURED EMER EXIT LIGHT. OPERATIONS CHECKED OK.SDR CALA2014100792372Light · inoperativeRIGHT SIDE OVERWING 3RD AFT EMER EXIT LIGHT INOPERATIVE. REPLACED LIGHT BULB. OPERATIONS CHECKED OK.SDR CALA2014100292355Battery · dischargedPER A CHECK, DOOR 5L SLIDE LIGHT DIM. AFTER CHARGING BATTERY ON LIGHT ASSEMBLY LIGHT NOW BRIGHT.SDR CALA2014100292356Light · defectivePER A CHECK DOOR 1L SLIDE LIGHT DIM. REPLACED DOOR 1L SLIDE LIGHT IAW MM 33-51-06. OPERATIONS CHECKED GOOD.SDR CALA2014092992350Light · inoperativeFOUND EMER LIGHT INOPERATIVE AT DOOR 2R. REPLACED THE RT NR 2 DOOR SLIDE EMER LIGHT & TESTED IAW AMM 33-51-06 REV 169 FOUND PASSED.SDR CALA2014092992351Seat Track · corrodedMAIN DECK SEAT TRACK FOUND CORRODED FROM STATION 1830 - 1870 LBL 11. REPLACED SEAT TRACK IAW DWG PXL 69B17959, SRM 51-40-05 & GMM 05-35-50 REV 55.SDR CALA2014092992352Seat Track · corrodedMAIN DECK SEAT TRACK FOUND CORRODED FROM STATION 1830 - 1870 LBL 33. REPLACED SEAT TRACK IAW DWG XPL 69B17959, SRM 51-40-05 & GMM 05-35-50 REV 5 5.SDR CALA2014092992353Seat Track · corrodedMAIN DECK SEAT TRACK FOUND CORRODED FROM STATION 1830 - 1870 RBL 11. REPLACED SEAT TRACK IAW DWG XPL 69B17959 REV A, SRM 51-40-05 REV 90 & GMM 05 -35-50 REV 55.SDR CALA2014092992339Floorbeam · corrodedFLOORBEAM CORROSION AROUND SCREW HOLE. FLOORBEAM UPPER CHORD REPAIRED IAW SRM 53-00-51 FIG 101.SDR CALA2014092992340Floor Support · corrodedMAIN DECK FLOOR STRAP CHANNEL FOUND CORRODED AROUND SCREW HOLE AT STATION 1790 LBL 12. CORRODED FLOOR SUPPORT REPLACED IAW DWG 140U5287 REV W DWG 146U5251 REV F & SRM 51-4 0-02.SDR CALA2014092992341Seat Track · corrodedMAIN DECK SEAT TRACK FOUND CORROSION FROM STATION 1890 - 1910 LBL 33. REPAIRED IAW SRM 53-00-52 REPAIR 9 & SRM 51-40-02.SDR CALA2014092992342Floorbeam · crackedMAIN DECK FLOORBEAM WEB FOUND CRACKED AT STATION 1660 RBL 33. REPAIRED IAW SRM 53-00-51 PG 201 REV 90.SDR CALA2014092992343Intercostal · corrodedMAIN DECK FLOOR INTERCOSTAL FOUND CORROSION AT STATION 1660 LBL 20. REPLACED IAW DWG 146U5620 & SRM 51-40-02 REV 90.SDR CALA2014092992344Intercostal · corrodedMAIN DECK FLOOR INTERCOSTAL STATION 1660 - 1640 BL0 FOUND CORRODED. REPLACED IAW DWG 146U5620 & SRM 51-40-02 DRV 9 0.SDR CALA2014092992345Floor Support · corrodedCORROSION ON CABIN FLOOR PANEL SUPPORT AT STATION 1660 - 1680 RBL 40. REPAIRED IAW SRM 53-00-52 FIG 201 REPAIR 5 REV 90.SDR CALA2014092992346Channel · corrodedMAIN DECK FLOOR STRAP CHANNEL FOUND CORROSION AT STATION 1700 RBL 11. REPAIRED IAW SRM 51-40-02 & 53-00-52 REPAIR 5.SDR CALA2014092992327Intercostal · corrodedMAIN DECK FLOOR INTERCOSTAL FOUND CORROSION AT STATION 1780 - 1795 LBL 5. FLOOR SUPPORT REPLACED IAW SRM 51-40-02 & DWG 146U5620 SH 10 REV A.SDR CALA2014092992328Floor Support · corrodedMAIN DECK FLOOR STRAP CHANNEL FOUND CORROSION AROUND SCREW HOLE AT STATION 1795 RBL 11. CORROSION FLOOR SUPPORT REPLACED IAW DWG 140U5287 REV W & 146U5251 REV F & SRM 51-40 -02.SDR CALA2014092992329Intercostal · corrodedMAIN DECK FLOOR INTERCOSTAL STATION 1740 - 1760 LBL 5.5 FOUND CORRODED. FLOOR SUPPORT REPLACED IAW SRM 51-40-02 & DWG 146U5620 SHT 10 REV A.SDR CALA2014092992330Intercostal · corrodedMAIN DECK FLOOR INTERCOSTAL FOUND CORRODED AT STATION 1700 - 1720 RBL 27.5. REPLACED IAW DWG 146U5253 SHT 28 & SRM 51-40-02.SDR CALA2014092492282Proximity Sensor · malfunctionedABORTED TAKEOFF 120-130 KTS, BRAKE TEMPS FROM 4 TO 7. FLIGHT DECK INDICATIONS SHOWED NR 1 REVERSER DEPLOYMENT. NO EVIDENCE OF REVERSER DEPLOYMENT, NO DAMAGE NOTED. CREW VERBAL:DURING T/O ROLL NR 1 REV AMBER UNLOCK INDICATOR PRESENT WITH NEED TO INCREASE SDR DALA2014092405211Engine · fireRETURNED TO DEPARTURE, WITH THE NR 4 ENGINE SHUTDOWN. CREW REPORTED THAT THEY HAD THE NR 4 ENGINE SURGE AT 600 FT AND THEN ABOUT 15 SECONDS LATER HAD A NR 4 ENGINE FIRE WARNING. FOLLOWED QRH AND BLEW BOTH FIRE BOTTLES, FIRE WARNING EXTINGUISHED. ENGINE CHANSDR CALA2014092492278Battery Pack · dischargedCABIN EMERGENCY EXIT LIGHT DIM FROM ROW 23 KJH - 43 KJH. REPLACED BATTERY PACKS. SYS CHECKED NORMAL.SDR CALA2014092492279Pdu · malfunctionedAFT CARGO FWD RT PDU INOPERATIVE, STARTED TO SMOKE. REPLACED AFT CARGO PIT FWD RT PDU PN 129100-3 IAW MM 25-53-0102.SDR CALA2014092402282Connector · unsecureUPPER DECK AFT FLOOR PROXIMITY EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED FWD EMERGENCY EXIT SIDE LIGHT, SECURED AFT & STAIRS EMERGENCY EXIT LIGHT CONNECTOR. OPERATIONS CHECKED OK.SDR CALA2014092990321Battery Pack · inoperativeUPPER DECK OVERHEAD STAIR EMER EXIT LIGHT INOPERATIVE. REPLACED BATTERY M5934, REPLACED FWD SIDEWALL EMER EXIT LIGHT STRIP. OPERATIONS CHECKED OK. SECURE AFT SIDEWALL & STAIRS EMER EXIT LIGHT CONNECTOR.SDR CALA2014092992324Light · inoperativeUPPER DECK AFT FLOOR PROXIMITY EMER EXIT LIGHT INOPERATIVE. REPLACED UPPER DECK STAIRS WALL FWD EMER EXIT LIGHT, FOUND IT DIM, REPLACED BATTERY. OPERATIONS CHECKED OK.SDR CALA2014092492275Pca · leakingAIRCRAFT DIVERTED DUE TO LT HYD SYS LOSS. QTY WAS AT .56 AT ITS LOWEST, .60 UPON ARRIVAL. UPON WALK AROUND FOUND EVIDENCE OF HYD LEAK AT RT ELEV PCA ACCESS PANELS. REPLACED RT OTBD ELEV PCA, SERVICED HYD TO FULL.SDR CALA2014092292254Floor Panel · corrodedCABIN FLOOR PANEL UPPER CHORD FOUND CORROSION AT STATION 1660 LBL 30. CABIN FLOOR PANEL UPPER CHORD AT STATION 1660 LBL 30. REPAIRED IAW SRM 53-60-51 FIG 201 REPAIR 1. NDT INSP IAW 5946 & BSOPM 20-20-02. NO CRACKS FOUND.SDR CALA2014092292247Floorbeam · corrodedMD FLOORBEAM FOUND CORROSION STATION 1700 RBL 19 TO 25. REPAIRED IAW SRM 53-60-51 REPAIR 1 FIG 2 01 REV 90. BSOPM 20-20-02 & CONDUCTIVITY TESTED IAW 5946 REV AA INSTEAD OF HFEC INSPECTION.SDR CALA2014092292248Floor Support · corrodedCABIN FLOOR PANEL SUPPORT FOUND CORROSION AT STATION 1660 - 1680 LBL 40. REPAIRED IAW SRM 53-00-52 FIG 201 REPAIR 5 & SRM 51-40-02.SDR CALA2014092292249Intercostal · corrodedMID FLOOR INTERCOSTAL AT STATION 1795 RBL 11 FOUND CORROSION. REPLACED IAW DWG 140U5607 REV B & SRM 51-60-02.SDR CALA2014092292250Channel · corrodedMID FLOOR STRAP CHANNEL FOUND CORROSION AT 1770 - 1800 RBL 40. REPAIR IAW SRM 53-00-52 FIG 201 RPE 5 & SRM 51-40-02. NDT INSP IAW PT6 51-00-00 PROC 23, NO CRACKS FOUND.SDR CALA2014092292251Floorbeam · corrodedFLOORBEAM FOUND CORROSION AROUND SCREW HOLE. REPAIRED IAW SRM 53-60-51 RPR 1 FIG 201.SDR CALA2014092292252Floor Support · corrodedMAIN DECK FLOOR PANEL SUPPORT FROM STATION 1830 - 1890 LBL CORROSION. REPAIRED IAW SRM 53-00-52 REPAIR 5 & SRM 51-40-02. NDT INSP IAW PT6 51-00-0 0 PROC 23. NO CRACK FOUND.SDR CALA2014091892246Light · damagedIAW A CHECK LAVATORY EEL AT DOOR 1R, TWO EACH FOUND DAMAGED & INOPERATIVE. REPLACED TWO EACH LIGHT ASSEMBLY CHARGER & BATTERY. OPERATIONS CHECKED OK.SDR CALA2014091892230Chiller · inoperativeAFT GALLEY SMOKE ODOR, CHILLER INOPERATIVE. R & R AFT RT GALLEY CHILLER IAW AMM 25-33-02. 28VDC PIN 6 NO 115VAC PINS 1, 2 & 3 AT CHILLER WDM 25-33-11, NO 115VAC AT RT AFT GALLEY POWER PANEL. SUSPECT RT AFT GALLEY ELCU TRIPPED. CYCLED RT UTILITY BUS SWITCH.SDR CALA2014091892236Unknown · odorTHE CABIN CREW REPORTS AN ODOR IN THE AFT GALLEY, AFT LT LAVATORY AREA. SMELL DISSIPATED APPROX 3 - 5 MINS AFTER SHUTTING OFF GALLEY EQUIPMENT IN AFT GALLEY. ACCOMPLISHED GALLEY, CABIN & LAVATORY INSPECTION & OPERATION IAW AMM 05-51-06-201. OPERATED AFT GALSDR CALA2014091292115Skin · damagedACFT SUSTAINED DAMAGE TO UPPER SKIN PANELS AFT OF THE BULKHEAD. ECRA 5310-06235 ACCOMPLISHED FOR REPAIR.SDR CALA2014091292108Skin · tornHOLE TEAR ON BOTTOM OF HORIZONTAL ELEVATOR BETWEEN FS STATION 157 & ELEV STATION 216 APPROX 8 - 10 INCHES LONG APPROX 1 INCH WIDE. REMOVED DAMAGE, VERIFIED NEW CORE MATERIAL, INSTALLED NEW CORE, SANDED SMOOTH, INSTALLED ADHESIVE FILM BMS 5-154. PERMANENT RESDR CALA2014090992100Light · inoperativeFLOOR PROXIMITY LIGHT EEL AT SEAT 19H INOPERATIVE. REPLACED LIGHT ASSEMBLY SEAT MOUNTED EEL CHECKED OK.SDR CALA2014090992101Light · inoperativeFLOOR PROXIMITY LIGHTS, EMER EXIT LIGHT AT SEAT 48H INOPERATIVE. REPLACED LIGHT ASSEMBLY . OPERATIONS CHECKED SEAT MOUNTED EMER EXIT LIGHT OK.SDR CALA2014090992095Wire Harness · damaged33K EEL LIGHT INOPERATIVE. REPLACED EEL LIGHT HARNESS. OPERATIONS CHECKED OK.SDR CALA2014090992096Light · inoperativeSEAT 9KJ AFT EEL LIGHT INOPERATIVE. REPLACED EEL LIGHT ASSEMBLY. OPERATIONS CHECKED OK.SDR CALA2014090392058Pump · leakingCENTER HYDRAULIC PRESSURE EICAS ALERT. HYDRAULIC PUMP LEAKING FLUID, CREW POWERED DOWN SYSTEM AND CONT. EMERGENCY DECLARED DURING ARRIVAL PHASE. LAND WITHOUT INCIDENT FOUND LINE FROM C2 PUMP TO CASE DRAIN FILTER LEAKING. TIGHTENED LINE, LEAK CHECK OF C2 PSDR CALA2014090392051Scavenge Pump · faultyNUMBER 1 ENG OIL TEMP AT TAKEOFF WAS 177 DEGREES & READING 28 QTS. MAINTAINED CLIMB UP TO 4000 FT. NR 1 ENG POWER WAS REDUCED & TEMP WENT TO 180 DEGREES & FLIGHT CREW SHUTDOWN ENG. REPLACED SCAVENGE PUMP IAW AMM 79-21-04-401, OIL TEMP THERMOCOUPLE IAW AMM79SDR CALA2014082892041Battery Pack · dischargedUPPER DECK LT DOOR BATTERY CHECK LIGHT DOES NOT TEST. REPLACED BATTERY PACK & POWER SUPPLY IAW AMM 52-23-14.SDR CALA2014082192000Structure · corrodedHORIZONTAL STAB TOP STRUCTURE CONSTANT BOX CTR SECTION ON RT HAS TWO EACH AREAS OF EXFOLIATION CORROSION BS 1725.5 & RBL 31, BS 1746.125 & RBL 35. REPAIRED TWO EACH AREAS OF HORIZONTAL STAB CONSTANT BOX CTR SECTION RT IAW SRM 55-10-01 & REO G18140. THIS REPASDR CALA2014082592018Skin · dentedSMALL DENT AFT OF RT AFT CARGO DOOR, FWD OF LIGHT. DAMAGED AREA CUT OUT BETWEEN BS 1351 & 1373, STRINGER 28R TO 29R. FABRICATED A REPAIR DOUBLER & TRIPLER, INSTALLED IAW REO G15668 REV B & ECRA 5361-01030. THE SKIN REPAIR RECEIVED FIRST STAGE APPROVAL. A N
Back to Pratt & Whitney PW4056