SDR 2001UALA01528Fan · defectiveSMELL OF ELECTRICAL SMOKE, STRONGEST NEAR AFT GALLEY LOWER DECK. UTILITY BUSSES DROPPED OFF, SWITCHES WERE TURNED OFF, SYSTEM WENT TO SMOKE CLEARING MODE, SMELL WENT AWAY, UTILITY BUSSES LEFT OFF. THE RIGHT OVERHEAD RECIRCULATION FAN WAS FOUND DEFECTIVE. THESDR 2001UALA01527Light · inoperativeEMERGENCY EEL LIGHT INOP UNDER CLOSET JUST FORWARD OF LAV 104. *S/D* REPLACED EEL STRIP, CHECKS OK.SDR 2001UALA01421Light · inoperativeEEL LIGHT INOP ON SEATS 2A AFT AND 4A FWD AND AFT.SDR S01472020Engine · surgesB-18207 DUE PERFORMANCE A "PACK OFF",MAX THRUST T/O PERFORMED,AT 500 FT ENG-3 SURGED,THRUST REDUCED ALL PARAMETERS NORMAL.C/A:1.IAW FIM 71-00-00,FIG 107,INSPECT ENG INLET/EXHAUST AREA,MCDS AND BLEED PORTS,BORESCOPE INSPECTED FOR COMPRESSOR/TURBINE BLADES,ALL CSDR S00473057Fuel ControlB-18202 DURING ENG START #1 ENG TAIL PIPE FIRE. NO FIRE WARNING PRESENT, CREW SHUT DOWN ENG, BOTH FIRE EXTINGUISHERS DISCHARGED.C/A:1.ENG INLET & EXHAUST VISUAL CK NML. 2.ENG REV. COWLING OPEN VISUAL CK NML. 3.EXCITER, CABLE, INGITOR PLUG RPLD. 4.ENG FIRE EXTISDR 2001UALA01302Fitting · damagedMAJOR REPAIR REPORTING THE 65B38230-3 AFT CARGO DOOR FORWARD ACTUATOR SUPPORT FITTING AND BRACKET WERE DAMAGED. REPAIR ACCOMPLISHED PER EVAG-7736 REV A REPAIR HAS BOEING APPROVAL AND DER APPROVAL.SDR 2001UALA00877Light · inoperativeEMERGENCY LIGHT INOP AT DOOR 1 LEFT AFT SILL. RELAMPED.SDR S01472016Engine · failedCOMPLETE REGISTRATION NUMBER (B18273) AFTER T/O THRUST HAS SET ON T/O ROLLING, LOUD BANG SOUND WAS HEARD, T/O IS ABORTED AT 110 KNOTS. (1) IAW FIM 71-00-00, ENGINE SURGE DURING FORWARD THRUST FIG 107 PERFORM ENGINE 4 INLET FAN BLADE, FAN CASE DUCT SEGMENTS, TUSDR 2001UALA00567Video Unit · inoperativeWHEN VIDEO CLOSET DOOR WAS PULLED UP IT HIT SOMETHING BEHIND THE VIDEO EQUIPMENT, SPARKS AND ELECTRICAL SMELL REPORTED BY CREW. VIDEO SYSTEM IS INOP.SDR 2001UALA00493Wire · brokenEMERGENCY EXIT LIGHTS-FLOOR LIGHT DAMAGED. SUPPLEMENTAL DATA UPDATE CAUSE: WIRE W2086-005-20 (REF. WDM33-51-52 PAGE 3 SHEET 1) 2 INCHES FROM CONNECTOR DX321 LOCATED AT DR4L. REPAIRED WIRE PER GNMM 2-0-15-1 PAGE 7.SDR 2001UALA00171Skin · crackedDURING ROUTINE MNTC AT SFO, MECHANIC SAW LIGHT COMING INTO RIGHT SIDE APU BATTERY COMPARTMENT FROM OUTSIDE. UPON INVESTIGATION, IT WAS DISCOVERED THAT 65B02777-601 SKIN ASSY WAS CRACKED THRU AT APPROX 3 O''CLOCK POSITION. IT APPEARS THAT THE AFT STR 11(65B02SDR 20010321CW004Seal · defectiveDURING TO, ENGINE SURGED AND DECREASING NR 2 ROTOR SPEED AND INCREASING EGT TAKEOFF CONTINUED, ENGINE SHUT DOWN AND AIR TURNBACK ACCOMPLISHED. DISASSEMBLY INSPECTION REVEALED HTP 1ST STAGE OUTER AIRSEAL (ROTATING) FAILED MATERIAL HAS BEEN SENT FOR REVIEW ANDSDR 2001UALA00138Light · shortedAPU FIRE HANDLE LIGHT ON INTERMITTENLY, ALSO EICAS MESSAGE BUT NO FIRE WARNING AURAL CREW DIVERTING. *S/D* INVESTIGATION INDICATES THAT THE INTERMITTENT FLICKERING OF THE APU FIRE HANDLE, ALSO KNOWN AS FIRE EXTINGUISHING SWITCH ASSEMBLY, APPEARS TO HAVE BEESDR S01427003Flap · damagedB18275 AFT LANDING FOUND LH INBD FORE FLAP DAMAGED.C/A:1.LH INBD FORE FLAP, MIDFLAP, LINK, SEQUENCE CARRIAGE, FITTING AND FIX PANEL DAMAGED WERE FOUND. 2.SENT AOG TEAM TO BKK, DAMAGED PARTS WERE REPAIRED OR REPLD. A/C RETURNED TO TPE ON 2001/02/03. 3.MIDFLAP, SDR 2001UALA00066Window · failedNUMBER THREE COCKPIT LEFT WINDOW INNER PANE SHATTERED INFLIGHT. CREW NOTED PRIOR TO WINDSHIELD FAILURE WINDOW WAS FROSTED OVER AND NOT DEFOGGING. REMOVED WINDOW AND FOUND CORROSION ON UPPER AND AFT LOWER SIDES.SDR ANCF200100005Pump · failedDURING FLIGHT FROM FRA TO SJU RH EDP HYD LOW PRESSURE CAME ON, FLIGHT PROCEDED TO BAQ. RT EDP WAS REPLACED IAW AMM 29-11-05, TEST WAS SATISFACTORYSDR 2001UALA00026Terminal · burnedIN CRZ HAD ELEC BURNING ODOR AND VISIBLE SMOKE AROUND CAPTS SIDE OF THE COCKPIT. UNABLE TO DETERMINE SOURCE. SCHEDULED: MEL TO LAX, DIVERTED TO PAGO PAGO. *S/D* PERFORMED DETAILED VISUAL INSPECTION OF THE COCKPIT AND FOUND LOWER LEFT L1 WINDSHIELD HEAT LUGSDR ANCF200100004Connector · dirtyAFTER T/O BOTH FLAP POINTERS WERE ON 1° WITH THE FLAP LEVER IN UP POSITION, AIRCRAFT RETURNED TO MEX. CLEANED CONNECTORS AT FSEU PERFORMED BITE TEST AND OPERATIONAL TEST IAW AMM 27-58-05 TEST OK, COULD NOT DUPLICATED FAULT, FLAP/SLAT VISUAL CHECK OK.SDR ANCF200100002Indicator · failedDURING TAKE OFF CAPTAIN AIRSPEED INDICATOR GOT STUCK AT 100 KNTS. TAKE OFF WAS ABORTED AT 116 KNTS. DEFERRED AIRSPEED INDICATOR INOPERATIVE PER MEL 34-13-1 ITEM 199 CAT C, ALSO CHECKED EFIS AIRSPEED INDICATOR ON CAPTAIN SIDE, IT WORKS NORMALLY.SDR 2000UALA00812Floorbeam · damagedMAJOR REPAIR ACCOMPLISHED TO FLOORBEAM WEB PER SRM 51-70-13-001 DOUBLER INSTALLED AFT SIDE OF CABIN FLOORBEAM BS 880 RBL 9 WL 199 HEIGHT OF BEAM APPROX 7 INCHES WIDE. *S/D* DAMAGE CAUSED AT CURRENT MAINTENANCE CHECK BY ACCIDENT WHEN PERFORMING WORK IN VICINISDR 2000UALA00807Fan · failedACRID ELECTRICAL BURNING SMELL THROUGHOUT CABIN AND COCKPIT. ISOLATED SMELL TO LOWER RIGHT RECORD. FAN. VERIFIED FAN INOP. WITH COCKPIT SWITCH ON. LEFT LOWER FAN OPERATES NORMALLY.SDR 2000UALA00810Controller · malfunctionedRUDDER TRAVELS TO FULL LEFT POSITION WITH RUDDER PEDALS IN NEUTRAL, WITH HYDRAULICS ON.SDR S00472102Engine · making metalB-18209 NR 3 ENGINE VIB 4.5, OIL TEMP 150,OIL PRESSURE 40 PSI,FOLLOW QRH PROCEDURE IFSD,ENG WINDMILL 41 MIN.A/C DIVERT TO HND.C/A:1.GRN INSP FOUND ALL 6 EA M.C.D & MAIN OIL FILTER HAD LOTS OF METAL CHIPS. ALSO FAN CASE RUBSTRIP WAS SEVERELY WORN OUT BY FAN BLASDR ANCF200000003Warning Light · illuminatedDURING TAKE OFF RT REVERSER ISOLATION VALVE MESSAGE. DISPLAYED AND REVERSER ISOLATION LITE ILLUMINATED, AND , T/O WAS ABORTED. ACCORDING FIM78-34-00 RT REVERSER SYSTEM WAS CHECKED AND FOUND SYSTEM FAILURE. WAS TRANSFER TO DMI 189 AS PER MEL 78-31-1 CAT C.SDR 2000UALA00692Light · inoperativeEEL LIGHT INOP IN FRONT OF LAV 102 B-ZONE RIGHT HAND SIDE.SDR 2000UALA00684Coffeemaker · dirtyAIRCRAFT AIR HAS UNUSUAL SMELL. *S/D* SUSPECT FOREIGN MATERIAL BURNT ON H22 HOT PLATE IN THE G2A GALLEY COMPLEX. NO MAINTENANCE PERFORMED PRIOR TO EVENT THAT WOULD CAUSE UNUSUAL SMELL. RECORD WAS INITIALLY CLOSED ON 12/07/2000. RECORD WAS UPDATED ON 1/05SDR ANCF200000002Controller · malfunctionedDURING CRUISE, LT ENGINE BLEED OFF DISPLAYED AND ENGINE BLEED AIR VALVE OFF LIGHT ILLUMINATED, WITH SWITCH ON. DUCT PRESS WAS ZERO PSI, NACELLE ANTI-ICE OPERATION NOT CHECKED. DURING GROUND CHECK FAIL HPSOV AND EICAS MESSAGE. IAW AMM 36-11-07 PAGE 401, THE SDR CA001110012Engine · flamed out(CAN) NR 4 ENGINE FLAME OUT DURING CRUISE.NO RESTART ATTEMPTED DUE TO HIGH VIBRATION. NR 4 ENGINE CHANGED.FURTHER DETAILS WILL FOLLOW AFTER INVESTIGATION. 2000,11-14TC: AWAIT FOLLOW-UP REPORT FROM ORIGINATOR.SDR 2000UALA00618Controller · malfunctionedEMERGENCY EXIT LIGHTS ILLUMINATED AFTER T/O AND REMAINED ON FOR APPROXMATLEY 1 HR (INTERMITTENT) WENT OFF JUST BEFORE DESCENT.SDR 2000UALA00619Light · malfunctionedCREW REPORTING EMERGENCY EXIT LIGHTS BLINKING ON AND OFF.SDR 2000UALA00622Light · malfunctionedTHE EMERGENCY LIGHTS IN CABIN ARE FLASHING. REMOVED SYSTEM POWER TO STOP.SDR 2000UALA00623Light · malfunctionedEEL IN ALL CABINS AND AFT CREW REST CAME ON INTERMITTENTLY FOR ABOUT 45 MINUTES THEN STOPPED.SDR 2000UALA00591Controller · malfunctionedFWD CARGO DOOR OPENED BY ITSELF WHEN CB PUSHED IN. ON ARRIVAL, CIRCUIT BREAKERS WERE PUSHED IN, WHEN PRESSURE RELIEF DOOR HANDLE WAS OPENED THE DOOR LATCHES OPENED AND THEN THE DOOR OPENED ON ITS OWN. COULD NOT DUPLICATE PROBLEM AFTER INITIAL OPENING.SDR CA001110018Light · failed(CAN) NUMEROUS EMERGENCY LIGHTS OUT ON AIRCRAFT FLOOR PATH LIGHTING. LIGHTS REPAIRED AT R1 DOOR, ISLES R3 AND UPPER DECK LIGHT SYSTEM CHECKED SERVICEABLE.SDR 2000UALA00580Tube · tornP/N 7A1479-13 EVACUATION SLIDE/RAFT DOOR 2 LT FAILED FLAT FIRE TEST IN HOME SHOP DURING SLIDE/RAFTS ROUTINE OVERHAUL. UPPER TUBE DEVELOPED A TEAR IN THE LT UPPER CROSSOVER TUBE AT THE BOTTOM CORNER. THE CAUSE OF THE TEAR APPEARS TO BE DAMAGE TO THE TUBE MATESDR 2000UALA00583Battery Pack · dischargedEMERGENCY LIGHTS IN CABIN BLINKING ON AND OFF. *S/D* REPLACED BATTERY PACK, CHECKED OK.SDR 0302277Alternator · leakingDURING FLIGHT RH ENGINE OIL DROPPED TO ZERO (0), OIL PRESS. WAS NORMAL, ONE HOUR DEFORE LANDING AT BOG OIL PRESS. WAS INTERMITTENT BETWEEN 120-104 PSI, LATER ON, THE PRESS. DROPPED TO 104-92 PSI THEM IT WENT TO 78 PSI WHEN ENGINE WAS IN IDLE POWER, FOR PRECAUTSDR 2000UALA00517Intercostal · damagedE-ZONE CABIN FLOOR INTERCOSTAL UPPER CHORD HAS EXCESSIVE MATERIAL. REMOVED AT BS 1834 - 1838. 30 PERCENT OF PARENT MAT''''L REMOVED AND LBL 41 AFTER CORROSION REMOVAL. MAJOR REPAIR WAS ACCOMPLISHED PER SRM 53-00-52 FIG 202.SDR 2000UALA00476A/C Pack · odorOILY SMELL FROM PACKS DURING CLIMB AND DESCENT. NOTE, PACKS IN HI-FLOW.SDR 2000UALA00349Line · leakingSTRONG HYDRAULIC SMELL IN THE COCKPIT. *S/D* SMELL DUE TO HYDRAULIC LEAK OF HYD SYSTEM NR 1 TUBE LOCATED IN FWD PIT AT AFT SIDE OF STA 900, STRINGER 28L. PIN HOLE DEVELOPED DUE TO CHAFING UNDER CLAMP. ACCOMPLISHED TUBE RINGLOCK REPAIR. LEAK CHECK ACCOMPLISDR 2000UALA00333Motor · failedAT CRUISE FL370 THE MAIN AND UPPER DECK EXPERIENCED STRONG ELECTRICAL PLASTIC SMELL UNDETERMINED ORIGIN BUT BARELY NOTICEABLE IN COCKPIT. THE SMELL MOVED RAPIDLY THROUGHOUT CABIN. TURNED OFF L-R UTILITY. SMELL DISSIPATED ON GROUND. F/A REPORTED AN ARCING NOSDR 2000UALA00325Light · illuminatedEMERGENCY LIGHTS ILLUMINATED ON EICAS. *S/D* RESET EMERGENCY LIGHT SWITCH AT DOOR 1 LEFT, OPS NORMAL. NOHISTORY.SDR 2000UALA00323Warning Light · illuminatedREJECTED TAKEOFF AT APPROXIMATELY 110 KNOTS DUE TO DOOR 5L WARNING LIGHT ON ICAS. *S/D* THE DOOR WAS CYCLED SEVERAL TIMES, AND THE SWITCH AND CONNECTOR WERE INSPECTED AND FOUND OK. THEN THE CABIN WAS PRESSURIZED TO 4.0 PSID AND NO DOOR WARNING OCCURRED. TSDR 2000UALA00307Slide · splitDURING SHOP OVERHAUL OF THE SLIDE RAFT, (P/N 7A1479-3) (S/N G185) A FOUR INCH SEAM SEPARATION DEVELOPED IN THE LOWER TUBE. THE SEPARATION IS BETWEEN THE LOWER TUBE ASPIRATOR FILL TUBE AND THE MAIN LOWER TUBE. THE UNIT WAS SENT TO THE VENDOR FOR EVALUATION SDR 2000UALA00270Light · inoperativeEEL LIGHT AT CROSSAISLE DOOR 5L AND 5R DOES NOT ILLUMINATE. *S/D* REPLACED EEL LIGHT ASSY, OPS CHECKED OK.SDR 2000UALA00243Bolt · crackedON WALKAROUND, FOUND 1.125 INCH DIA H-11 BOLT BROKEN AT STATION 1480 BODY LANDING GEAR INBOARD TRUNNION SUPPORT FITTING. *S/D* CAUSE WAS DUE TO STRESS CORROSION. REPLACED BOLT (69B13682-1) AND PERFORMED ULTRASONIC INSPECTED ADJACENT (2) BOLTS COMMON TO FITTSDR 2000UALA00206Unknown · odorSTRONG ELECTRIC BURNING ODOR IN UPPER DECK GALLEY. TURNED OFF ALL ELECTRIC SWITCHES AND SMELL SEEMED TO DIMINISH BUT DID NOT GO AWAY. STRONGEST AROUND COFFEEMAKER. ALSO ELECTRIC ODOR AROUND UPPER DECK DOORS, MOVED PASSENGERS. CREW WRITE UP STATES F/A''S RESDR 2000UALA00205Gasper Fan · failedREPORT OF BURNING SMELL IN COACH CABIN. TURNED OFF RECIRCULATING FANS AND SMELL WENT AWAY. *S/D* GASPER FAN REPLACED. NO FURTHER PROBLEMS.SDR 2000UALA00195Oven · smokeOVEN IN 1ST CLASS STARTED SMOKING INTERNALLY. NO FIRE OR FLAMEOBSERVED. USED HALON AND WATER EXTINGUISHER INSIDE OVEN. ALL CB''S PULLEDFOR THAT GALLEY AREA PRECAUTIONARY. DID NOT APPEAR TO BE ELECTRICPROBLEM. MAY HAVE BEEN OBJECTS INSIDE. *S/D* SUSPECT SDR 2000UALA00194Heater · failedELECTRIC BURN SMELL IN COCKPIT. TURNED OFF LOWER RECIRCULATING FAN PER MEL. SMELL WENT AWAY. *S/D* REPLACED PILOTS SHOULDER HEATER (P/N: 2831-2). NO PROBLEMS AFTER, PROBABLE CAUSE WAS INTERNAL FAILURE.
Back to Pratt & Whitney PW4056