SDR 2000UALA00167Light · damagedEEL AND TRIM TORN AFT GALLEY. REPLACED GALLEY EEL STRIP. OPS CHECK GOOD.SDR 2000UALA00157Compressor · failedHOT ELECTRICAL ODOR SMELLED IN COCKPIT AND FRONT OF FIRST CLASS AREA. *S/D* POTABLE WATER SYSTEM AIR COMPRESSOR WAS FOUND TO HAVE BEEN OVERHEATING AND SMOKING. SHOP FINDINGS FOUND WATER IN COMPRESSOR. REPLACED AIR COMPRESSOR AND UNLOADER CHECK VALVE.SDR 2000UALA00122Spar · burnedAPPROX .375 INCH DIAM ARCING BURN-THROUGH DAMAGE TO NR 2 PYLON FWD MID SPAR WEB AT CORNER OF LIGHTENING HOLE. DAMAGE WAS DUE TO ARCING BURN-THROUGH OF WORN GENERATOR FEED CABLE TO NR 2 PYLON FWD MID SPAR WEB (P/N: 311U4156-1). A WEB DOUBLER REPAIR ADAPTED FRSDR AU000197Valve · failed(AUS) INBOARD NR 3 FUEL TANK OVERRIDE/JETTISON PUMP INLET CHECK VALVEFLAPPER SEPARATED CAUSING DAMAGE TO THE PUMP. METAL IN NO3 ENGINE FUEL FILTER.SDR CA000320025Pump · failed(CAN) EICAS MESSAGE INDICATING NR 1 HYD SYS FAILURE. AIR DRIVEN PUMP FAILED. EDP UNDER MEL. ALTERNATE SELECTION WAS USED FOR LANDING GEAR. REPLACED ADP AND REACTIVATER EDP BY REPLACING TWO HYD LINES A/C SERVICEABLE.SDR CA000320024Line · cracked(CAN) EICAS MESSAGE NR 1 HYD SYS PRESSURE DECREASED, NR 1 SYS SHUT OFF, EMER LANDING CARRIED OUT. DEACTIVATED NR 1, FOUND LEAK ON TWO LINES, ONE CRACKED, REPLACED TWO LINES A/C SERVICEABLE.SDR 2000UALA00091Tube · crackedENGINE NUMBER TWO OIL QUANT ZERO, OIL PRESSURE DECREASING. SHUT DOWN NR 2WITH 73 PSI. WINDMILL OIL PRESS 15-16 PSI. NR 2 ENGINE IN FLIGHT SHUT DOWN DUE TO LOSS OF OIL PRESSURE AND OIL QTY. ENGINE WILL REQUIRE REMOVAL. OIL LOSS WAS CAUSED BY A CRACKED NUMBSDR 2000UALA00081Slide · deployedDOOR 5L SLIDE DEPLOYED DURING CONDITIONAL CHECK OF DOOR. BUSTLE REMOVED AND SLIDE WAS LOOSE, FELL TO FLOOR AND DEPLOYED INSIDE OF CABIN. *S/D* CENTER RELEASE MECHANISM WAS TRIGGERED DURING MAINTENANCE INSPECTION. SLIDE BUSTLE WAS REMOVED AND SLIDE DEPLOYEDSDR 2000UALA00067Line · crackedNR 4 ENGINE OIL QTY DROPPED TO ZERO IN FLIGHT. OIL PRESSDECREASING AND OIL TEMP INCREASING. IN FLIGHT SHUT DOWN AND RETURNED TO FIELD. *S/D* ANGLE GEARBOX OIL PRESSURE LINE (LP09) FAILED BEHIND THE FORWARD B-NUT CONNECTION. THE LINE FAILED DUE TO HIGH CYCSDR 2000UALA00068Duct · crackedNR 3 ENG SHUTDOWN BY CREW DUE TO FIRE WARNING. BOTTLES NOT DISCHARGED. *S/D* IPCV (PN: 773856-19 ) SEPARATION OCCURRED AT THE INLET BRAZE WELD WHICH JOINS THE INLET DUCT TO THE MAIN ASSY OF THE IPCV (REF HAMILTON SUNDSTRAND CMM 36-12-06 PAGE 520 VIEW B) ALLSDR 99UAL900641Switch · malfunctionedEMERGENCY LIGHTS STAY ON WITH COCKPIT SWITCH OFF. AUTOMATIC FUNCTION WORKS NORMALLY WITH SWITCH ARMED. *S/D* REPLACED 1 RT DOOR EMERGENCY LIGHT SWITCH AND SWITCH GARD (CH7724). BOEING IS IN THE PROCESS OF DETERMINING A SOLUTION TO THE FAULTY CARD SWITCH. SDR 99UAL900620Light · malfunctionedEMERGENCY LIGHTS EICAS ADVISORY MESSAGE DISPLAYED. EMERGENCY LIGHTS SWITCH NOT IN ARMED POSITION, OR SWITCH IN ARMED POSITION ON AND EMERGENCY LIGHTS TURNED ON BY FLIGHT ATTENDANT SWITCH.SDR 99UAL900613Light · malfunctionedEMERGENCY LIGHTS EICAS ADVISORY MESSAGE DISPLAYED. EMERGENCY LIGHTS SWITCH NOT IN ARMED POSITION AND EMERGENCY LIGHTS TURNED ON BY FLIGHT ATTENDANT SWITCH.SDR 99UAL900573Light · inopRT SIDE OVERWING EMERGENCY LIGHT IS INOP, MOST FWD LIGHT ASSEMBLY AFT LAMP ONLY.SDR 99UAL900572Light · malfunctionedALL EMERGENCY LIGHTS CAME ON AT LEVEL OFF. CYCLING BOTH SWITCHES AND CB'S, NO HELP.SDR 99UAL900543Power Pack · inopEMERGENCY EXIT LIGHTS AT ROWS 15-18 LEFT SIDE ARE INTERMITTENT. UPPER DECK EEL POWER PACK FAILED. REPLACED POWER PACK.SDR CA991103091Tire · failed(CAN) DURING WALK-AROUND, FOUND NR 11 TIRE TREAD PEELED OFF CAUSING DAMARE TO SEVERAL PANELS AND HARNESS DAMAGE. TIRE REPLACED, PANELS AND HARNESS REPAIRED.SDR AU991015Rod · worn(AUS) FOLLOWING REMOVAL OF THE RT PYLON BOAT FAIRING FOR REPAIR THE FOLLOWING DEFECTS WERE FOUND: 1. RT ENGINE DRIVEN HYDRAULIC PUMP PRESSURE AND SUPPLY LINE ELBOW JAM NUTS BACKED OFF AND ELBOW FRETTING IN PYLON RECEPTACLES2S. 2. INBOARD VERTICAL STRAKESDR 99UAL900461Light · inopEMERGENCY LIGHT IN CEILING NEXT TO DOOR 3 LEFT, INOP. RELAMPED CHECKS GOOD.SDR 99UAL900448Tube · tornSLIDE/RAFT (P/N 7A1479-13) (S/N G1863) FAILED FLAT FIRE INFLATION TEST. UPPER INFLATION TUBE RUPTURED AT THE TOP RT CORNER. THIS IS THE FIRST UAL SHOP VISIT FOR THIS UNIT. DATE OF MANUFACTURE WAS 4/96 AND LAST OVERHAUL BY VENDOR WAS 5/30/96. *S/D* PROBABLSDR CA990927082Oven · malfunctioned(CAN) EN ROUTE ELECTRICAL SMELL IN FORWARD GALLEY, GALLEY POWER TURNED OFF BURN SMELL PERSISTED, EMERGENCY DECLARED AND AIRCRAFT LANDED. OVEN REMOVED AND ROUTED FOR REPAIR. NEW OVEN INSTALLED AND RUN FOR ONE HOUR AND NO SMELL.SDR 99UAL900375Wire · broken1L MED EMERGENCY SLIDE LIGHT (ON DOOR) ILLUMINATES WHEN POWER IS OFF AIRCRAFT. THIS PROBLEM WAS CAUSED BY A DISCONTINUITY IN THE CIRCUIT. A GROUND WIRE WAS FOUND BROKEN (ROUTING OF WIRE IS FROM DX317, PIN 1 TO GD6338). WIRE W2078-001-20 WAS REPLACED (REF WSDR 99UAL900357Structure · damagedTHE FUSELAGE SKIN, BETWEEN BS 480 AND 520, STR 37R TO 40R WAS DAMAGED DUE TO CONTACT WITH GROUND EQUIPMENT. THE FRAME AT STA 500 ALSO WAS DAMAGED BETWEEN STR 37 AND 39 AT THE SKIN ATTACHMENT AND STRINGERS 38, 39 AND 40 WERE DAMAGED. THE 3 STRINGERS WERE REPLSDR CA990614081Actuator · failed(CAN) AILERON LOCK-OUT ON EICAS STATUS REPORT. LEFT AILERON ACTUATOR REPLACED.SDR 99ZZZX2776Engine · malfunctionedGOB/LON - FLT 016 - AIR TURN-BACK. DURING LIFT-OFF, LEFT ENGINE STARTED TO STALL. EGT WENT TO 802. LEFT ENGINE WAS REDUCED AND STALL CONDITION DISAPPEARED. AIRCRAFT RETURNED AND MADE AN OVERWEIGHT LANDING WITH LEFT ENGINE IN IDLE. SUBMITTER STATED ENGINE SDR CA990719035Computer · failed(CAN) JUST AFTER TAKEOFF, STICK SHAKER ACTIVATED FOR 3 SECONDS. CONTINUED TO FL 310, ALTIMETER DISAGREE AMBER MESSAGE ON EICAS. QUICK REF PROCEDURE RESULTED IN CAPTAIN'S ADI TO C AND FIRST OFFICER TO L, MESSAGE EXTINGUISHED. TRIED TO CONTINUE BUT ON CLIMB ABSDR 99UAL900310Air Dist · odorINBOUND CREW REPORTED BAD SMELL THROUGH THE WHOLE AIRPLANE.SDR 99UAL900299Bolts · looseRIGHT WING LANDING GEAR BEAM OUTBOARD END GATE FITTING SUPPORT ASSEMBLY (P/N 65B08186-30) SHOWED SIGNS OF MOVEMENT DUE TO BROKEN SEALANT. INSPECTION REVEALED TWO UPPER BOLTS (P/N BACB30US10K54) AND LOWER BOLTS (P/N BACB30PE10C45W) WERE LOOSE. THE BOLTS ATTACSDR 99UAL900274Battery · dischargedEEL LIGHT INOP UPPER DECK FROM SEAT 15AB TO 18AB. REPLACED BATTERY, CHECKS OK.SDR 99UAL900216Battery Pack · dischargedUPPER DECK RIGHT HAND EXIT DOOR BATTERY WOULD NOT TEST. *S/D* REMOVED AND RESET BATTERY ON PACK.SDR 99UAL900144Intercostal · crackedAT APPROXIMATELY BODY STATION 322, THERE EXISTS A CRACK IN THE 141U8007-502 INTERCOSTAL. THE CRACK EXISTS IN THE LOWER HORIZONTAL FLANGE AND EXTENDS TO THE SECOND FASTENER HOLE COMMON TO THE 141U8007-501 SPLICE. *S/D* 141U8007-502 TRIMMED OUT AROUND CRACKED ASDR 99UAL900105Switch · malfunctionedEMERGENCY LIGHTS ON WHEN SELECTED TO OFF. *S/D* RESET EMERGENCY LIGHT SWITCH AT DOOR 1L, OVERHEAD SWITCH. NOW CHECKS NORMAL.SDR 99UAL900059Humidifier · dirtySMOKE IN COCKPIT SUDDENLY OCCURRED DURING CRUISE FLIGHT. SELECTED HUMIDIFIER OFF AND SMOKE DISSIPATED. *S/D* HEAVY CALCIUM DEPOSITS IN UNIT. SUSPECT SMOKE WAS ACTUALLY CALCIUM IN DUCTS. SHOP CLEANED AND CHECKED UNIT SERVICEABLE.SDR 99UAL900061Humidifier · smokingSMOKE IN COCKPIT SUDDENLY OCCURRED DURING CRUISE FLIGHT. SELECTED HUMIDIFIER OFF AND SMOKE DISSIPATED.SDR 99UAL900030Light · brokenEEL LIGHT BROKEN AT RIGHT-HAND MIDDLE GALLEY AREA. REPLACED EEL LIGHT AT RIGHT-HAND GALLEY AND REPLACED FEEDER WITH COVER.SDR 99UAL900033Light · inopEEL STRIP AT DOOR 2R IS TORN AND THE CONNECTOR IS RIPPED OFF. ALSO, THE COVER IS MISSING. *S/D* REPAIRED AND CHECKS OK.SDR 98UAL900609Strip · damagedEEL STRIP AT DOOR 2L DAMAGED. REPLACED ENCAPSULATED 72 INCH EEL STRIP AT DOOR 2L. OPS CHECKS OK.SDR 98UAL900557Pump · damagedFUEL OVERRIDE/JETTISON PUMP PART NR 60-72101 DASH 2 RECOVERED FROM THE NR 2 MAIN FUEL TANK (FWD POSITION) OF ACFT 8407 WAS FOUND TO EXHIBIT EXCESSIVE IMPELLER END-PLAY AND GOUGING OF THE IMPELLER UNIT WITH THE INLET ADAPTER. TESTING OF THE PUMP BY THE VENDOR SDR 98UAL900562Pump · damagedFUEL OVERRIDE/JETTISON PUMP PART NR 60-72101 DASH 1 RECOVERED FROM THE CENTER WING FUEL TANK OF ACFT 8480 WAS FOUND TO EXHIBIT EXCESSIVE IMPELLER END-PLAY AND GOUGING OF THE IMPELLER UNIT WITH THE INLET ADAPTER. THE THRUST WASHER/BEARING IS SUSPECTED TO HAVE SDR 98UAL900560Pump · damagedFUEL OVERRIDE/JETTISON PUMP PART NR 60-72101 DASH 1 RECOVERED FROM THE CENTER WING FUEL TANK OF ACFT 8188 WAS FOUND TO EXHIBIT EXCESSIVE IMPELLER END-PLAY AND GOUGING OF THE IMPELLER UNIT WITH THE INLET ADAPTER. THE THRUST WASHER/BEARING IS SUSPECTED TO HAVE SDR 98UAL900555Pump · damagedFUEL OVERRIDE/JETTISON PUMP PART NR 60-72101 DASH 2 RECOVERED FROM THE NR 2 MAIN FUEL TANK (AFT POSITION) OF ACFT 8407 WAS FOUND TO EXHIBIT EXCESSIVE IMPELLER END-PLAY AND GOUGING OF THE IMPELLER UNIT WITH THE INLET ADAPTER. TESTING OF THE PUMP BY THE VENDOR SDR 98UAL900561Pump · damagedFUEL OVERRIDE/JETTISON PUMP PART NR 60-72101 DASH 1 RECOVERED FROM THE CENTER WING FUEL TANK OF ACFT 8672 WAS FOUND TO EXHIBIT EXCESSIVE IMPELLER END-PLAY AND GOUGING OF THE IMPELLER UNIT WITH THE INLET ADAPTER. THE THRUST WASHER/BEARING IS SUSPECTED TO HAVE SDR 98UAL900558Pump · damagedFUEL OVERRIDE/JETTISON PUMP PART NR 60-72101 DASH 1 RECOVERED FROM THE CENTER WING FUEL TANK OF ACFT 8192 WAS FOUND TO EXHIBIT EXCESSIVE IMPELLER END-PLAY AND GOUGING OF THE IMPELLER UNIT WITH THE INLET ADAPTER. THE THRUST WASHER/BEARING IS SUSPECTED TO HAVE SDR 98UAL900559Pump · damagedFUEL OVERRIDE/JETTISON PUMP PART NR 60-72101 DASH 1 RECOVERED FROM THE CENTER WING FUEL TANK OF ACFT 8496 WAS FOUND TO EXHIBIT EXCESSIVE IMPELLER END-PLAY AND GOUGING OF THE IMPELLER UNIT WITH THE INLET ADAPTER. THE THRUST WASHER/BEARING IS SUSPECTED TO HAVE SDR CA981113021Engine · failed(CAN) ON LIFT-OFF, NR 3 ENGINE HAD A COMPRESSOR STALL ALONG WITH A RAPID RISE IN EGT TO 700 DEGREES CELSIUS. ENGINE WAS SHUT DOWN. POST-FLIGHT BORESCOPE INSPECTION OF HIGH AND LOW COMPRESSORS AND TURBINES CARRIED OUT, ALL PARAMETERS NORMAL. PRECAUTIONARY CHSDR 98UAL900498Tube · tornSLIDE/RAFT FAILED PROOF TEST DURING UNIT OVERHAUL IN HOME SHOP, CAUSING A 6 FOOT TEAR IN THE TOP TUBE CENTER CROSSOVER TUBE. CAUSE COULD NOT BE DETERMINED. SENT UNIT TO VENDOR FOR EVALUATION AND REPAIR.SDR 98UAL900514Tube · tornSLIDE/RAFT FAILED PROOF TEST DURING OVERHAUL DUE TO A 6 FOOT TEAR IN THE TOP TUBE CENTER CROSSOVER TUBE.SDR 98UAL900494Sill · crackedVERY LOUD WHISTLE OUT OF NR 3 COCKPIT WINDOW, RIGHT REAR WINDOW ON FO SIDE WAS NOTICED ON DEPT AND ARRIVAL WITH CAB DIFF PRESS AT 5.O. *S/D* DUE TO SQUEALING, THE WINDOW WAS REMOVED AND CORROSION DAMAGE WAS FOUND AT THE LOWER AFT CORNER STA 338. THE DAMAGE SDR 98UAL900463Brace · gougedA .060 INCH DEEP GOUGE IN PYLON NUMBER ONE DIAGONAL BRACE. THE GOUGE IS 40 INCHES FORWARD OF AFT END OF DIAGONAL BRACE AND 1.74 INCHES LONG BY .5 INCH WIDE. CAUSED BY CONTACT WITH STEEL PNEUMATIC LINE. PYLON NUMBER ONE DIAGONAL BRACE REPLACED BEFORE FURTHERSDR 98UAL900423Bulb · failedOVERHEAD EMERGENCY LIGHT INOP AT SEAT 33CD AISLE LIGHT. REPLACED 1317 LAMP IN LIGHT ASSEMBLY, OPERATIONAL CHECK GOOD.
Back to Pratt & Whitney PW4056