SDR CALA2013093091579Battery · failedDL3387 SHORT STBY PWR OPERATIONAL CHECK FAILED. REPLACED MAIN BATTERY & ACCOMPLISHED TEST IAW MM24-31-01, SHORT STBY PWR CHECKED NOW NORMAL IAW CALJIC.SDR CALA2013093091591Light · inoperativeDURING MAINTENANCE CHECK, CABIN PAX SEAT ROW 23ABC, 23HJK, 40HKJ, 42ABC, 53ABC, 56ABC & 4A EMERGENCY EXIT LIGHT FOUND INOPERATIVE. RELAMPED SEAT ROW 23ABC, 23HJK, 40HKJ, 42ABC, 53ABC, 56ABC & 4A IN SEAT EMERGENCY EXIT LIGHT, OPERATIONS CHECKED NORMAL IAW AMM SDR CALA2013100191621Starter · failedLT ENG NO ROTATION GOT START VALVE INDICATION & PNEU PRESSURE DROP BUT NO ROTATION. REPLACED STARTER IAW MM. OPERATION CHECKED NORMAL, IAW LM7346 FOR STARTER COVER REPLACEMENT.SDR CALA2013093091558Pump · faultyRT HYD PRIM PUMP EICAS ON STEADY AT TAXI OUT. R & R NR 2 ENG EDP IAW AMM, FAILED OPERATIONS CHECK, SMC 4 CREATED TO COVER FAILED OPERATIONS CHECK. REMOVED RT ENGINE DRIVEN PUMP, PULLED RT FIRE HANDLE IAW AMM 29-11-05. NEEDS FILTERS, R & R PUMP INSTALLATION. SDR CALA2013093091562Valve · faultyAPU SHUTDOWN DURING ENGINE START ACCOMPANIED BY FAULT LIGHT. REPLACED APU SURGE VALVE IAW AMM, APU OPERATIONS NORMAL.SDR CALA2013100191629Light · unsecureEXIT LIGHT FELL OFF AT 1R. RE-SECURED LIGHT, OPERATIONS CHECKED GOOD.SDR CALA2013100291670Actuator · failedBLG STEERING MALFUNCTION ON PUSHBACK FROM GATE. RT SIDE TURNS, LT SIDE FAILS TO MOVE. CHECKED HISTORY, NON FDE. FOUND MESSAGE 'LEFT BODY GEAR LEFT ACTUATOR LOCK SWITCHES DISAGREE'. REPLACED LT BLG, LT ACTUATOR IAW AMM. GROUND TEST & LEAK CHECK PASSED.SDR CALA2013093091555Life Vest · missingNEED ONE LIFE VEST SEAT 40F. REPLACED LIFE VEST.SDR CALA2013100191626Fuse · blownTWO OF FOUR EMERGENCY EXIT LIGHTS INOPERATIVE FOR RT SIDE OVER WING SLIDE. CHANGED POWER SUPPLY, REPLACED FUSES IN THE OLD POWER SUPPLY & REINSTALLED OLD POWER SUPPLY. OPERATIONS CHECKED RT EXTERIOR EGRESS EMERGENCY EXIT LIGHTS & ALL FOUR LIGHT ASSEMBLY OPERSDR CALA2013092791504Light · inoperative59C EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED LIGHT AT SEAT 59C, OPS CHECKED GOOD.SDR CALA2013092691471Connector · faultyNR 2 VHF COMM TRANSMISSION & RECEPTION INOPERATIVE AT ALL CREW STATIONS, 1=L VHF, 2=R VHF. R & R NR 2 VHF ANTENNA CONNECTOR D7 IAW WDM 23-12-02 & SWP 20-51-15. OPERATIONS CHECKED SATISFACTORY.SDR CALA2013092691499Guide Vane · erodedNR 1 ENG FAN EXIT GUIDE VANES HAVE SEVERAL LE FOIL TAPE REPAIRS ERODED. REPLACED TAPES ON LE GUIDE VANES ON NR 1 ENG.SDR CALA2013092691474Skin · dentedAFT CARGO DOOR IS DENTED ABOVE LATCH & AT CTR OF DOOR. DENT IS CRACK FREE & WITHIN MM 52-30-01 LIMITS. NO FURTHER ACTION IS REQUIRED.SDR CALA2013092591422Skin · corrodedMAIN DECK FUSE SKIN AT BS 1475 STRINGER 15L TO 16L FOUND CORRODED. CUTOUT & REMOVED DAMAGED SKIN, HFEC CUTOUT & FASTENER HOLES, NO DEFECT NOTED. FABRICATED & INSTALLED REPAIR DOUBLER AT BS1475 STRINGER 15L TO 16L IAW SRM 53-00-01 RPR15 FIG 201 DETAIL I, PG 2SDR CALA2013092691497Cover · brokenDOOR 2R ARM-DISARM COVER BROKEN. REPLACED 2R ARM-DISARM COVER IAW AMM.SDR CALA2013092691498Fire Warning · failedFIRE TEST FAIL CARGO COM CHRONIC LEVEL 1.SDR CALA2013092691500Unknown · odorAFT GALLEY HAD SMOKE & ELECTRICAL SMELL ALONG WITH AN EICAS MESSAGE UTILITY BUS L. CREW ACP CHECKLIST, DESELECTED L UTILITY BUS, SMOKE DISSIPATED. AHM SHOWS EE CEILING SUP FAN STATUS MESSAGE. CREW INDICATED NO VISIBLE SMOKE IN CABIN. FOUND UPPER FAN POWERSDR CALA2013092691501Light · inoperativeNO SMOKE SIGN INOP ACROSS FROM JUMP SEAT 5L. RELAMPED, OPS CHECKED OKAY.SDR CALA2013092791508Sensor · faultyAPU AUTO SHUT DOWN, CAUSING GATE RETURN. TROUBLE SHOT IAW FIM 49-1 1-00, FOUND REVERSE FLOW ON BITE. R & R INLET TEMPERATURE SENSOR IAW AMM. R & R FLOW SENSING MODULE IAW AMM. ALL OPERATIONS & LEAKS CHECK GOOD AT THIS TIME. APU OK TO CONTINUE.SDR CALA2013092491388Line · leakingNR 4 FRONT BRAKE BODY GEAR BRAKE LINE LEAKING BEYOND LIMITS. PLUGGED & CAPPED BRAKE LINE BOTH ENDS. NEED BRAKE LINE 180-0265. SEE IPC 32-41-00-010 ITEM 20. INOPERATIVE NR 4 BRAKE IAW METHOD 2. THE BRAKE DEACTIVATED IS NR 6 ACCORDING TO BOEING DIAGRAM. REPSDR CALA2013092491402Light · unsecureLAVATORY 102 EMERGENCY LIGHTS OUTSIDE DOOR ARE FALLING OFF WALL. SECURED LIGHT ASSEMBLY & PERFORMED, OPERATIONS CHECKED OKAY.SDR CALA2013092491413Cover · unsecureEXIT COVER AT 1L FELL OFF. EXIT COVER AT DR 1L REFITTED. INSTALLATION & SECURITY CHECKED SATISFACTORY.SDR CALA2013092591461Lens · missingAPU FIRE DISCHARGE LIGHT MISSING LENS COCKPIT CENTER PEDESTAL. REPLACED APU FIRE DISCHARGE KORRY SW, OPERATIONS CHECKED GOOD IAW BSWPM 20-84-18.SDR CALA2013092491400Guard · looseEMERGENCY LIGHT TURN ON WITH THE SWITCH IN THE OFF POSITION, LIGHTS CAME ON, ON LANDING THEN WENT OUT. AT DR 1L FOUND ATTENDANT EMERGENCY LIGHT SWITCH GUARD LOOSE & CAUSING LIGHTS TO ILLUMINATE. SECURED GUARD OPERATIONS CHECKED OK.SDR CALA2013092491401Gate · corrodedR1 DOOR LOWER GATE CORROSION FOUND. R1 DOOR LOWER GATE REPLACED IAW AMM 52-11-01.SDR CALA2013092391351Coupler · failedCAPTAIN GETTING RADIO BLEED OVER ON RCP 1FLT INTERPHONE. LT HF INOPERATIVE. COMPLIED WITH MEL REQUIREMENTS. REPLACED CAP AUDIO SELECT PANEL, NO HELP. RPLD AMU REF AMM 23-51-04 -401. NEED OP CK WHEN PLANE IS OUT OF HANGER FOR VHF L AND R PER AMM TASK 23-51-00SDR CALA2013092391359Bleed Valve · failedAPU PNEUMATICS FAILED. REPAIRED & REPLACED APU BLEED VALVE IAW AMM. VERIFIED OPERATIONS & LEAK CHECKED GOOD. PLACARDS REMOVED.SDR CALA2013092391374Unknown · malfunctionedR2 DOOR ARM DISARM LEVER WILL NOT MOVE TO ALL THE WAY DOWN POSITION. BLOCKED THE UNUSABLE SEATS & DOOR IAW MEL 5211J. CONFIRMED THE DOOR IS CLOSED.SDR CALA2013092391375Circuit Card · faultyNR 2 FUEL CUTOFF SWITCH LIGHT INTERMITTENT DURING FIRE TEST. TEST FAILS WITH OVHT. REPLACED AFOLTS CARD & CLEANED FLT DESK TEST SW. TESTED ABOVE 4 TIMES PASSED.SDR CALA2013092391376Connector · unsecureUNABLE TO TEST LT IN SATCOM SYS SELECT SWITCH ALL CBS ARE IN PROG TEXT: - ITEM ROLLED FORWARD. SECURED SWITCH CONNECTOR.SDR CALA2013092491396Girt Bar · faultyR2 DOOR ARM DISARM LEVER WILL NOT MOVE TO ALL THE WAY DOWN POSITION. BLOCKED THE UNUSABLE SEATS & DOOR IAW MEL 5211J. CONFIRMED THE DOOR IS CLOSED. REPLACED NR 2 RT DOOR GIRT SLIDE BAR IAW AMM & ALONG WITH GRIT BAR FITTING. OPERATIONS CHECKED DOOR ARMING SSDR CALA2013092491412Actuator · malfunctionedLT PACK TEMPERATURE EICAS ON FINAL WON'T CANCEL. LT PACK INOPERATIVE IN AUTO, WORKS OK IN STAND BY. LT PACK TEMPERATURE CONTROLLER M126 BITE PROCEDURE CARRIED OUT IAW FIM 21-51-00,101. BIT SHOWS RAM OUTLET ACTR FAULT, VERIFY SHOWS ALSO RAM OUTLET ACTR FAULTSDR CALA2013092091316Light · inoperativeEMERGENCY EXIT LIGHT DOOR 2 CROSS AISLE FWD WALL MIDDLE LAMP INOPERATIVE. RELAMPED IAW MM. VERIFIED.SDR CALA2013092091317Light · missingSEAT 45H MISSING EMERGENCY EXIT LIGHT STRIP. REPLACED EMERGENCY EXIT LIGHT STRIP IAW MM. VERIFIED IAW MM.SDR CALA2013092091318Light · inoperativeDOOR 4R FWD SILL EMERGENCY LIGHT INOPERATIVE. RELAMPED 1317 DOOR 4R FWD SILL EMERGENCY LIGHT. OPERATION CHECKED GOOD.SDR CALA2013092391327Skin · crackedNR 3 INBD REVERSER SLEEVE OUTER SKIN CRACKED 3 O'CLOCK POSITION, APPROXIMATELY 10" IN LENGTH. REPLACED NR 3 INBD REVERSER SLEEVE IAW AMM. OPERATIONS CHECKED NORMAL.SDR CALA2013092391328Floorbeam · corrodedMAIN DECK FLOOR BEAM AT BS 1660 LBL40 TO RBL40 FOUND CORRODED. BLENDED OUT OF MD FLOOR BEAM AT BS1660 FROM LBL 40 TO RBL40. MATERIAL LOSS EXCEED SRM ALLOWABLE LIMITS. TRIMMED UPPER CHORD, ACCOMPLISHED HFEC NO DEFECT NOTED. FABRICATED & INSTALLED UPPER T-CHSDR CALA2013092391329Floorbeam · corrodedMAIN DECK FLOOR BEAM AT BS1700 LBL2 TO RBL 28 FOUND CORRODED. BLENDED OUT CORROSION OF MAIN DECK FLOOR BEAM AT BS 1700 LBL2 TO RBL 28. MATERIAL LOSS EXCEEDED SRM ALLOWABLE LIMITS. TRIMMED UPPER T CHORD, ACCOMPLISHED HFEC, NO DEFECT NOTED. FABRICATED & INSTASDR CALA2013092391353Control Switch · faultyLT WING FLT CONTROL SHUTOFF SWITCH ON AUX PANEL WAS FOUND IN OUT OFF POSITION. LT WING FLT CONTROL SHUTOFF VALVE DEFERRED INOPERATIVE IAW MEL. CONTROL SWITCH REQUIRED REPLACEMENT. MEL DEACTIVATION PROCEDURE & TEST ACCOMPLISHED.SDR CALA2013092391360Circuit Card · faultyLT ENG FIRE LOOP 2 STATUS MSG INTERMITTENTLY COMES ON & GOES OFF. R & R NR 2 LOOP ENG 1 CARD FILE M682 IAW AMM 26-10-01-401, IAW FIM 26-11-00 & OPERATIONS CHECKED AMM 26-11-00.OPERATIONS CHECK GOOD.SDR CALA2013092491398Light · inoperativeDOOR 4R FWD SILL EMERGENCY LIGHT INOPERATIVE. RELAMPED 1317 DOOR 4R FWD SILL EMERGENCY LIGHT. OPERATIONS CHECKED GOOD.SDR CALA2013092491399Light · missing24H SEAT MOUNTED EMERGENCY EXIT LIGHT MISSING. REPLACED SEAT MOUNTED EMERGENCY EXIT LIGHT AT 24H IAW MM, OPERATIONS CHECKED OKAY.SDR CALA2013092091300Actuator · leakingREPORTS OF FUEL LEAK FROM RT ENG DRAIN. FOUND FUEL LEAKING FROM TCC AIR VALVE ACTUATOR. R & R TCC AIR VALVE ACTUATOR IAW MM. OPERATIONS & LEAK CHECKED GOOD.SDR CALA2013092091301Battery · failedMAIN AIRCRAFT BATTERY DEAD. R & R MAIN AIRCRAFT BATTERY IAW AMM 24-31-01.SDR CALA2013092091302Warning System · false activationON LANDING DECELERATING THRU 120KTS AURAL GEAR WARNING & CONFIG LITE WITH SPEED BRAKE LITE. ACCOMPLISHED PSEU BITE NO EXISTING FAULTS, LANDING CONFIG WARNING TEST TAKE OFF & LANDING PASSED, RA-NO FAULTS, SPOILER CONTROL MODULES NO FAULTS, INSPECTED WW & GEAR SDR CALA2013092091303Tape · deterioratedNR 2 ENGINE EXIT GUIDE VANES HAS NUMEROUS REFLECTIVE TAPE DETERIORATING AT LE.SDR CALA2013092391377Connector · unsecureLOWER CARGO SMOKE DETECTOR SYSTEM VACUUM TUBE CONNECTOR HOSE COMING LOOSE. RESECURED, REPLACED HOSE CONNECTOR PART NUMBER 453U2803-2 IPC IAW 26-16-00-005 PAGE 27 ITEM 85.SDR CALA2013092091309Doubler · crackedL5 DOOR FWD CUTOUT DOUBLER CRACKED. CUTOUT DAMAGED SKIN, ACCOMPLISHED HFEC, NO DEFECT NOTED. FABRICATED & INSTALLED REPAIRED DOUBLER IAW SRM 53-60-15 REPAIR 3.SDR CALA2013092091310Doubler · crackedR5 DOOR FWD CUTOUT REVEALED DOUBLER CRACKED. CUTOUT DAMAGED SKIN, ACCOMPLISHED HFEC NO DEFECT NOTED. FABRICATED & INSTALLED REPAIRED DOUBLER IAW SRM53-60-15 REPAIR 3.SDR CALA2013091891286Oxygen Mask · failedSECOND OBSERVERS OXYGEN MASK FAILED TEST.
Back to Pratt & Whitney PW4056