Pratt & Whitney PW4060
Service difficulty reports · 7,186
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012020600690Slide · unserviceableLEFT WING OW SLIDE INFLATION HOSE KINKED AND TWISTED OUT OF LIMITS. REMOVED & REPLACED LEFT OVERWING SLIDE.SDR UALA2012020600689Actuator · faultyRUDDER RATIO LIGHT & EICAS MSG, RTFL. FAULT BALL FOUND IN PCA POSTION ON BOTH RRCM'S. REPLACED RRCA WITH BORROWED PART S-N 1008. OPS CHECKS GOOD, NO FAULTS.SDR UALA2012020600693Filter · leakingMAIN OIL FILTER WAS REPLACED AND ENGINE WAS MOTORED, BUT ENGINE STILL NEEDS 5 MIN ENGINE RUN, UNABLE TO RUN ENGINE DUE TO LACK OF HYDS. RAN ENGINE FOR 5 MINUTES, NO LEAKS FOUND.SDR UALA2012020600688Feeder Cable · damagedCLEANERS VACUUMED UP PORTION OF EEL LIGHTING AFT OF DOOR 1L. REPLACED FEEDER CABLE. GROUND CHECKS NORMAL.SDR UALA2012020600718Regulator · leakingPRIOR TO COA 615671 FOUND O2 SYSTEM LEAKING WHEN SUPPLY WAS SHUTOFF. OXYGEN LEAK EXCEEDS LIMITS. OXY PRESS REG RPLC'D, OPS CK LEAK CKD SYS GOOD.SDR UALA2012020600716Antenna · failedWXR FAIL DSPLYD ON HSI. WXR FAIL WEAK DSPLYD ON HSI IN WXR TEST POS'N. CREW COMMENTS: WXR FAIL WEAK RT DISPLAYS. REPLACED WXR RADAR ANTENNA, ALL OPS CHECKS SATISFACTORY.SDR UALA2012020600717Transceiver · defectiveWXR WEAK MESSAGE INTERMITTENTLY DISPLAYED OI CAP AND F/O HSI. REPLACED WXR XCVR PER MM, CHECKS GOOD.SDR UALA2012020600711Valve · faultyDIFFICULT TO CONTROL TEMP IN COCKPIT. MIX VALVE SHOWS FULL WARM WITH COLD AIR STILL BLOWING. FLT DECK TRIM VLV SHOWS WARM, BUT COLD AIR IS COMING IN, CREW CYCLED MASTER TRIM VLV AND OPERATED FLT DECK TRIM VLV IN MANUAL, NO HELP. REPLACED TRIM AIR VALVE.SDR UALA2012020200622Skin · corrodedBS 1540 AT BL 0 AFT BULK CARGO COMPARTMENT INTERNAL FUSELAGE SKIN CORRODED AT DRAIN VALVE (N-R 4175N00498). MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE, FABBED AND INSTALLED DOUBLER AND FILLER AND PART MARKED PER SRM AND GNMM 1-01-007 ON NR 4175N00498.SDR UALA2012020200637Skin · damagedDAMAGE TO FUSELAGE SKIN BELOW FWD LWR CORNER OF BULK CARGO DOOR APROX 10" LONG X 4.5" WIDE LOCATED AT BS 1428 ABOVE & BELOW STRINGER S34L. MAJOR REPAIR ACCOMPLISHED. EVALUATED DENT & FOUND OUT OF LIMITS OF SRM. CUT OUT DAMAGE & ACP VISUAL & NDT INSP FOR CRASDR UALA2012020300664Stop Fitting · damagedAFT CARGO DOOR AFT FRAME LWR STOP FITTING (NR 10) HAD INTERIM REPAIR ACCOMPLISHED DURING C-14 CHECK IN TPA PER EC-RA 5360-01181. DAMAGE CAREFULLY BLENDED REF EA PD67-53-065 & UAL EC-RA 5360-01181. PERFORMED HFEC INSPECTION OF BLENDED AREA. NO DEFECTS NOTED.SDR UALA2012020200652Modulating Valve · faultyTEMPERATURE OSCILLATES + AND - 10 DEGREES IN BOTH CABIN & COCKPIT. NEEDS MORE TIME TO T/S. REPLACED ZONE TRIM AIR MODULATING VALVE PER MM, OPS TEST NORMAL.SDR UALA2012020300662Servo Valve · faultyAIRFRAME VIBRATION. WITH CTR A-P ENGAGED VIBRATION FELT IN BOTH YOKES, NOT FELT IF USING LEFT OR RT AUTOPILOTS. CARRIED OUT BPCU BITE AND CARRIED OUT MCDP TESTS NO FAULTS NOTED. SERVICE TIP IS FOR ENGINES RUNNING IN FLIGHT, ON GROUND ENGINES OFF AP STILL HASDR UALA2012020200659Rub Strip · looseNR 2 ENG RUB STRIP LOOSE LEADING EDGE OF REV COWL. INTERIM REPAIR ACCOMPLISHED PER ECRA 7111-01296. CLEANED AREA WITH SOLVENT PER GPM. APPLIED 3 LAYERS OF ALUMINUM TAPE 2524-2-0200 TO DISCREPANT AREAS. TAPE TO BE RE-INSPECTED EVERY 25 HOURS BEGINNING PTT 8SDR UALA2012020200620Nut · looseLANDING GEAR MONITOR STATUS EICAS MSG REPORTED BY CREW AFTER GEAR RETRACTION. TIGHTENED LOOSE NUT RT FWD NLG IDLER HINGE, TORQUED NUT PER AMM. ACCMP'D GEAR SWING SEVERAL TIMES PER AMM. EICAS MSG WAS CLEAR ON NR 4175N00193.SDR UALA2012020200633Slide · unserviceableRT OFF WING ESCAPE SLIDE INFLATION HOSE IS COLLAPSED AND APPEARS INTERNALLY DETERIORATED ALONG 80 PERCENT OF ITS LENGTH. REPLACED RT OFF-WING SLIDE PACK PER MM. ACCOMPLISHED RII INSPECTION, CRITICAL STEPS GROUP NR 1, OF RT OFF WING SLIDE INSTALLATION.SDR UALA2012020200621Light · inoperativeEEL PATH LIGHT INOP AT FWD VIDEO CLOSET. REPLACED EEL LIGHT AT FWD VIDEO CLOSET, OPS CHECK GOOD PER AMM ON NR 4175N00542.SDR UALA2012013000606Monitor · faultyRT HYD SYSTEM QTY IS 0.02; R HYD QTY EICAS MSG DISPLAYED. SAMC TEXT: WITH RT QTY LOW LIGHT ALSO. TOMC MAINT TEXT: PER CREW, PUMP LOW PRESS LIGHTS DID NOT ILLUMINATE PRESSURE NORMAL. NO SIGNS OF EXTERNAL LEAKAGE. REPLACED HYD QTY MONITOR UNIT PER MM, QTY SYSDR UALA2012013000583Battery · dischargedEEL LEFT CENTER FLOOR STRIP AND CENTER CROSS AISLE FLOOR STRIP ARE INOP. REPLACED EEL BATTERY BY SEAT 22A. OPS CHECKS NORMAL.SDR UALA2012013000585Rvdt · faultyAFTER FLAP EXTENSION, GOT FLAP SLAT ELEC STATUS MSG AND DURING FLAP SLAT RETRACTION GOT T/E CAUTION LIGHT. REPLACED M548 SLAT TRANSDUCER RVDT PER MM 27-81-11 PAGE 412 AND ACP TESTS PER MM 27-51-00 PAGE 501 AND MM 27-81-00 PAGE 501 SYS PASSED OKAY.SDR UALA2012013000604Transceiver · inoperativeWX FAIL DISPLAYED ON NR 3 HSI(S). WXR TEST INOP. (1=CAPT, 2=1ST OFF, 3=BOTH). FOUND AS STATED DF PER MEL. ACP'D FAULT ISOLATION REF MM, WXR FAIL DISPLAYED ON EHSI, WRX UNIT DEAD, NO PWR. REPLACED WRX XCVR, SYSTEM TESTS OKAY.SDR UALA2012013000580Light · intermittentEMERGENCY PATH LIGHTS BY WINDOW EXIT LEFT SIDE 19A-B FLASH ON & OFF. CHECKED EEL FAULT. COULD NOT REPRODUCE, OK DURING GROUND CHECK.SDR UALA2012013000573Keelbeam · corrodedKEEL BEAM CORRODED ON UPPER SURFACE AROUND 2 EACH NUT PLATES AT STA 997.9 - 1002 RBL 10. BLENDED UPPER AREA OF KEEL BEAM 0.020' MATERIAL REMOVED FOUND TO BE WITHIN LIMITS PER SRM 53-50-12.SDR UALA2012013000574Keelbeam · corrodedKEEL BEAM CORRODED ON UPPER SURFACE AROUND NUT PLATE AT STA 1002 LBL 10. BLENDED KEEL BEAM UPPER SURFACE, MATERIAL LOSS 0.066", FOUND TO BE WITHIN LIMITS PER SRM.SDR UALA2012013000572Wire · brokenCARGO FIREX BOTTLE 1 AND 2 FAILS, DOES NOT SHOW ON EICAS. NO EICAS CARGO BOTTLE 2 LIGHT. RE-TERMINATED BROKEN WIRE AT D5673P PER SWPM 20-61-16, OPS CHECK GOOD PER AMM 26-23-00 AND TC 612224910.SDR UALA2012013000603Satcom · faultyNO COMM DISPLAYED ON ACARS DISPLAY UNIT OVER OCEAN. ACARS SENDS OK IN VHF RANGE. CREW COMMENTS: SATCOM CONSTANTLY REQUESTING LOGON. SAMC TEXT: MAINTENANCE REPORT SATCOM SYSTEM INOP HIGH & LOW GAIN. AFTER SAT AND ACARS SYSTEM RESET IDU SHOWS SATCOM ALWAYS ISDR UALA2012013000599Blade · nickedUNFILED NICK ON OUTER BLADE (7 O'CLOCK) POSITION ENG NR 1. FOUND NR 4 FAN BLADE WITH NICK AT LEADING EDGE 0185 INCH DEEP ABOUT FIVE EIGHT INCH FROM EDGE AND ONE TREE QUARTER OF INCH AT END. ACCOMPLISHED BLADE BLEND PER AMM. BLADE WILL REQUIRE EDDY CURRENT ISDR UALA2012012700555Light · inoperativeSEAT ROW 32 LT SIDE BULLNOSE EMERGENCY EXIT LIGHT INOP. REPLACED SEAT 32 LEFT BULLNOSE EEL LIGHT, OPS CK GOOD PER AMM ON NR 4175N00005.SDR UALA2012012700556Lens · missingSEATS 32 AND 37 J-K EEL LIGHTS MISSING LENS, OPERATES PROPERLY. REPLACED SEATS 32 AND 37 J-K EEL LIGHTS, OPS CK GOOD PER AMM 33-51-00 ON NR 4175N00004.SDR UALA2012012700569Selector Panel · faultyRT HF TRANSMISSIONS ARE INOP, WEAK, GARBLED, INTERMITTENT AT (1=CAPT,2=F-O,3=F-OB) STATION. OTHER STATIONS NORMAL. TRIED NEW TRANSCEIVER, NO HELP. REPLACED O/B AUDIO SEL PNL. OP CKS OK.SDR UALA2012012600548Engine · surgesNR 2 ENG SURGE DURING T/O. ABORTED T/O AT 40KTS. RPLC NR 2 ENG SN 717690 DUE ENGINE SURGE, RESULTING IN ABORTED TAKEOFF & RECENT PARAMETER SHIFT. RMV'D NR 2 ENG SN 717690. INSTALLED ENG 727968.SDR UALA2012012600554Fitting · wornLT MLG TRUNNION DOOR AFT HINGE HAS EXCESSIVE PLAY. FOUND AFT DOOR FITTING HAT BUSHINGS WORN AND PULLED OUT OF FITTING. NEW FITTING ASSY ON ORDER. WILL NEED FITTING 113T8313-6 AOG S5293. WORKING OUTSIDE. WILL REQUIRE GEAR SWING AFTER FITTING REPLACEMENT. SDR UALA2012012500526Floorbeam · corrodedPASS CABIN FLOOR STRUCTURE AT STA 347, LBL 43 - 49 FLOORBEAM IS CORRODED. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGE, FABBED AND REPLACED T-CAP, 2 ANGLES, AND STRAP REPAIR PER SRM 51-40-02 ON NR 3872N00516.SDR UALA2012012500527Stiffener · crackedNLG WHEEL WELL STA 287 LT VERT STIFFENER CHORD FAILED HFEC INSPECTION. CRACK INDICATION APPROX 55 INCHES ABOVE BOTTOM OF CHORD WHERE MARKED. CUT OUT DAMAGE, FABBED AND INSTALLED FILLER AND ANGLES (3 EA) PER SRM 51-40-02 ON NR 3872N00117.SDR UALA2012012500528Floorbeam · damagedPASSENGER CABIN AT STA 1197 RBL 56-80 FLOORBEAM IS SHOWING BARE METAL AROUND FASTENER HOLES AND GOUGES. COUNTER TOP REPLACED BY PEMCO VENDOR (REGENT) IAW 4 FLIGHT CMM 25-30-24, 8130 FURNISHED ON PEMCO NR 3872N00988. INCORRECT ACTION TAKEN FOR PTT 1552114, SHSDR UALA2012012400505Anti-Ice Valve · faultyLEFT ENG ANTI-ICE VALVE LIGHT ON. VERIFIED SOLENOID AND VALVE OPERATION PER MEL ITEM 3021C. MEL REF: 3021C. PARTS: 643-9002 MR30133 VALVE ASSY. REPLACED WITH NEW TAI VLV, OPS CHECKED NORMAL PER MMSDR CA120125001Engine · surges(CAN) ON FINAL APPROACH, CAPTAIN AND F/O OBSERVED THAT THE RIGHT HAND ENGINE WAS NOT RESPONDING PROPERLY TO THROTTLE INPUTS. EGT LIMITS EXCEEDED. ENGINE SURGING WAS NOTED AND PASSENGER REPORTED HAVING OBSERVED TORCHING.SDR UALA2012012400485Bearing · faultySUSPECT NOSE GEAR DOOR SLIGHTLY DROOPING AS FEEL LIGHT VIBRATION IN CRUISE FL 340 MACH .820. SAMC TEXT: CREW NOTICED RUMBLING MORE PRONOUNCED ON MID CABIN LEFT SIDE. TURNED OFF FWD GALLEY EQUIPMENTS, INCREASE & DECREASED AIR SPEED, NO CHG. ENG'S PNEUMATIC SDR UALA2012012300482Brake · damagedNR 1R BRAKE LEAKING AND PUCKS DAMAGED ON ARRIVAL. REPLACED BRAKE PER MM.SDR UALA2012012300476Unknown · malfunctionedLEFT ENG ANTI ICE VALVE LT ON WITH ENG SHUT DOWN AND SWITCH IN OFF POS. CLEANED ELEC CONNECTOR ON ENG INLET THERMAL ANTI-ICE VLV. LIGHT EXTINGUISHED. PROBLEM RECURRED.SDR UALA2012012300477Computer · inoperativeTMC INOPERATIVE. REPLACED TMC PER MM. OPERATED NORMAL, AIRCRAFT REMOVED FROM CATIII, ACCOUNT OF TMC CHANGE SEE DEFERRED ITEM FOR CATIII CHECK.SDR UALA2012012000432Door · saturatedCF968 AND CF967 WATER INGRESS ON MLG DOORS, DOORS REMOVED TALKED TO SHOP WITH EST FOR DOORS RETURN IS 0700-23. LT MLG DOOR IS ON R&R R57058, RT MLG IS ON R57057, SAILTAIL IS ON R57059* SHOP REPORTS SPARE RT MLG DOOR AVAIL BY TOMORROW.SDR UALA2012012000436Computer · faultyR EICAS CMPTR STATUS. REPLACED RT EICAS COMPUTER. DOWNLOADED DATA PER MM. OPS CKS OKAY.SDR UALA2012011900412Control Unit · faultyFLAP-SLAT MSG. TRBLSTG PER FIM. NEW FSEU, NO HELP. FAULTING M548 OTBD SLAT POS XDCR. ON AOG, E5555 ETA 0450. DMM 0240. REPLACED FSCU PER MM. SYSTEM OPERATED NORMAL. NO EICAS OR STATUS MSG. PRESENT.SDR UALA2012011900393Skin · dentedEXT FUSELAGE SKIN DENTED STA 654+110, STR 30L. DENT WITHIN LIMITS, HFEC OF AREA FOUND MATERIAL DISTRESSED. CUT OUT DAMAGE, FABBED AND INSTALLED DOUBLER AND FILLER IAW SRM 53-00-01 AND 51-40-02 ON PEMCO NR 3872N00076.SDR UALA2012011900422Transceiver · faultyNR 1 VHF COMM XMISSIONS ABNORMAL AT ALL CREW STAT'N (1= L VHF, 2=R VHF). REMOVED AND REPLACED LT VHF TRANSCEIVER. OPS CK GOOD IAW B767-300 MM.SDR UALA2012011800372Floorbeam · corrodedBS 287 FLOORBEAM RT UPPER T-CAP REPAIR HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. RMV'D EXISTING REPAIR, FABBED AND INSTALLED T-CUP, 2 EA ANGLES, AND 1 EA STRAP PER SRM 51-40-02 ON PEMCO NR 3811N00414.SDR UALA2012011700356Actuator · faultyAILERON LOCK-OUT, RTFL. REPLACED RIGHT AND LEFT AILERON LOCKOUT ACTUATORS REF MM. LOCKOUT ACTUATOR AND MECHANISM TEST GOOD ON RIGHT AND LEFT SIDE.SDR UALA2012011600346Wire Harness · defectiveRIGHT VIBRATION GAUGE INDICATES 0 BOTH N1 AND N2. REPLACED NR 2 ENGINE ACCELEROMETER. ACP'D IDLE RUN AND N1 SHOWED 0.0 TO 0.1, N2 STAYED AT 0.0. IDLE RUN INCONCLUSIVE. REPLACED WIRE HARNESS FROM PLUG D8836P TO ACCELEROMETER D10994 DUE TO OPEN WIRE W3504-01TSDR UALA2012011600319Apu · faultyAPU FIELD OFF LIGHT ON AFTER APU REPLACEMENT DURING OPS CHECK. REPLACED APU FUEL CONTROL, NO HELP. APU AUTO SHUTDOWN FAULT LIGHT ON OVERTEMP ECU MESSAGE. MR49305 ON-86 OFF159. TRIED TWO FUEL CONTROL UNITS. SAME RESULT. SWAPPED APU CONTROL UNIT (ECU) AND
Back to Pratt & Whitney PW4060