SDR UALA2009021700499Anti-Ice Valve · faultyRIGHT ENG ANTI-ICE REMAIN ON WITH SWITCH IN OFF POSITION. REPLACED RT ENG ANTI-ICE VALVE. VALVE OPS NORMAL.SDR UALA2009021800547Cable · defectiveAFTER T/O AFT GALLEY PIGTAIL SPARKING AND POPPING NOISE. AFT GALLEY LOST PWR2 OF 5 PNL'S. FWD GALLEY ALSO LOST PWR. RT HYD QUANTITY WENT TO ZERO AND RETURNED TO NORM TWICE, STABILIZED AT 0.93. RT FUEL QUANTITY BLANKED AND RETURNED TO NORM. PULLED C/B N52 ISDR UALA2009031000547Cable · defectiveAFTER T/O AFT GALLEY PIGTAIL SPARKING AND POPPING NOISE. AFT GALLEY LOST PWR 2 OF 5 PNL'S. FWD GALLEY ALSO LOST PWR. R HYD Q WENT TO ZERO AND RETURNED TO NORM TWICE, STABILIZED AT 0.93. RT FUEL Q BLANKED AND RETURNED TO NORM. PULLED CB N52 IN AFT GALLEY ASDR UALA2009021800546Battery · faultyRIGHT EMERGENCY ESCAPE SQUIB WON'T TEST. REPLACED BATTERY FOR RT SYSTEM. OPS CHECKS NORMAL ON GROUND.SDR UALA2009021300490Wire · exposedEMERGENCY EXIT LIGHT STRIP HAS EXPOSED WIRES LEFT SIDE FIRST CLASS. REPAIRED EMERGENCY LIGHTS STRIP.SDR DL76P090192Probe · unknownRIGHT ENGINE CONTROL EICAS MESSAGE AFTER ENGINE START. REPLACED P2/T2 PROBE, OPS NORMAL.SDR DL76G090193Pump · malfunctionedLT CENTER FUEL PUMP LIGHT ILLUMINATED. LT FUEL OVRD PUMP C/B OPEN. T/S PER FIM. OPEN ACCESS PNL FOR PUMP. REMOVED CONNECTOR INSPECTED PINS AND SOCKET NO TROUBLE FOUND. INSPECTED HARNESS VISUALLY IN HOUSING AREA NO DEFECTS NOTED C/B RESET OPERATED PUMP 25 SDR UALA2009021300474Power Supply · faultyEMERGENCY FLOOR LIGHTS AT RIGHT OVERWING EXIT FLICKER ON AND OFF. ARMED EMERGENCY LIGHTS AND RT EEL EXIT LIGHTS CAME ON. REPLACED EEL EMERGENCY POWER SUPPLY M1554, OPS OK.SDR UALA2009021300476Light · faultyEEL LIGHT BAR L985 AND L904 PARTIALLY ILLUMINATES. REMOVED BAD LIGHT BARS AND REPLACES WITH SERVICEABLE LIGHT BARS L985 AND L904 AT RT AFT LAV AND CENTER AFT GALLEY AREA AND OPS CHECK GOOD.SDR UALA2009021300477Light · faultyEEL LIGHT BAR L910 PARTIALLY ILLUMINATES. REMOVED BAD EEL LIGHT BAR AND INSTALLED SERVICEABLE LIGHT BAR L910 AT AFT LT LAV, AND OPS CHECK GOOD.SDR UALA2009021300478Light · faultyEEL LIGHT BAR L896 PARTIALLY ILLUMINATES. REPLACED LIGHT BAR L896 AT RT MID LAV-CLOSET AND OPS CHECK GOOD.SDR UALA2009021300479Light · faultyEEL LIGHT BARS L905 AND L897 DO NOT FULLY ILLUMINATE. REMOVED BAD LIGHT AND INSTALLED SERVICEABLE LIGHT BARS L905 AND L897 AT MID LT LAV AND CENTER PARTITION AND OPS CHECK GOOD.SDR UALA2009021300480Light · faultyEEL LIGHT BAR L901 NOT FULLY ILLUMINATED. REPLACED LIGHT BAR L901 AT FWD RT GALLEY AND REPLACED BATTERY AT CHARGER M730, OPS CHECK GOOD.SDR UALA2009021300481Light · faultyFWD EEL LIGHT BARS L900 AND L908 DO NOT FULLY ILLUMINATE. REMOVED BAD LIGHT BARS AND REPLACED WITH SERVICEABLE BARS L900 AND L908 AT FWD LT CLOSET AND CENTER GALLEY AREA, AND OPS CHECK GOOD.SDR CA090210011Duct · crackedDURING INSPECTION FOUND AC DUCT CRACK THE DAMAGE AIR CONDITIONING DUCT RUN’S FROM A TRIM AIR SUPPLY MODULATING VALVE (UNPRESSURIZE AREA) TO THE MIX MANIFOLD OUTLET DUCT (FWD CARGO PRESSURIZE AREA) THR : 60554 TCY : 9972 TLN : 9972.SDR CA090211002Duct · crackedDURING THE INSPECTION FOUND AC DUCT CRACK, THE DAMAGE AIR CONDITIONING DUCT RUN`S FROM A TRIM AIR SUPPLY MODULATING VALVE (UNPRESSURIZED AREA) TO THE MIX MANIFOLD OUTLET DUCT (FWD CARGO PRESSURIZE AREA).SDR HALA2009020600041Coil · burned1.5 HOURS OUTSIDE OF PDX, 39KFT, A/T DISCONNECT MESSAGE, ENGINE STARTED TO SPOOL DOWN. PDX MX FOUND CHIP DETECTORS CLEAN, SMALL AMOUNT OF METAL IN MAIN OIL FILTER, FUEL FILTER CLEAN. TRIED TO MOTOR ENGINE, HAD N1 INDICATION BUT NO N2 INDICATION. REMOVED PMASDR UALA2009020500399Apu · making metalAPU GEARBOX CHIP DETECTOR HAS AT LEAST 3 PARTICLES ABOVE .050 IN ADDITION TO SEVERAL SMALLER SHINY CHIPS ACCUMULATED. REPLACED APU. APU OPS CHECK AND LEAK CHECK GOOD.SDR UALA2009031000399Apu · making metalAPU GEARBOX CHIP DETECTOR HAS AT LEAST 3 PARTICLES ABOVE .050 IN ADDITION TO SEVERAL SMALLER SHINY CHIPS ACCUMULATED. REPLACED APU. APU OPS CHECK AND LEAK CHECK GOOD.SDR HALA2009020400040Engine · vibrationATB FIRST INDICATION, LOUD SOUND FROM RIGHT SIDE WITH VIBRATION, AUTO THROTTLE DISCONNECT, R ENGINE EEC MODE. PERFORMED CHECKLIST PROCEDURE, BOTH EEC IN ALTERNATE MODE. REMOVED NR 2 ENGINE.SDR UALA2009020400377Pump · faultyLEFT ENG PRIMARY HYD PUMP LIGHT ON WITH EICAS WHEN REVERSING ENG ON LANDING-ON FOR 3 MINUTES AFR. REPLACED LEFT ENG EDP. ACCMP'D LEFT ENG EDP, OPS CHECKS. ALL OPS & INDICATIONS NORMAL. ALSO REPLACED PRESSURE & CASE DRAIN FILTERS.SDR UALA2009020200364Feeder Cable · misinstalledNR 1 ENG IDG FEEDER CABLES ARE INCORRECTLY ROUTED. REROUTED FEEDER CABLES FROM UPPER ENG AREA TO NR 1 IDG DISCONNECT. SECURED HARNESS.SDR UALA2009020200345Light · inoperativeEMERGENCY LIGHT BARS FWD CABIN LEFT AND RIGHT ARE INOP. INSTALLED NEW LIGHT BARS, OPS CHECK GOOD. LT AND RT FWD CABIN.SDR UALA2009020200347Battery · dischargedAFT LT AND RT UPPER EXIT SIGN HANDLE ILLUMINATION ASSY INOP. INSTALLED NEW BATTERY, OPS CHECKS NORMAL. REPLACED LT AND RT UPPER SIGNS, OPS CHECKS NORMAL.SDR UALA2009013000326Seat Track · damagedMAIN CABIN STA 965 AT LBL 88.5 SEAT TRACK HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED SECTION OF SEAT TRACK, STA 944 TO 1032. INSTALLED NEW SECTION.SDR UALA2009012900311Battery Pack · inoperativeRT FWD ENTRY DOOR UPPER FWD EMERGENCY LIGHT INOP. REPLACED BATTERY PER MM 33- 51-07, OPS CHECKS GOOD.SDR UALA2009012900312Battery Pack · inoperativeLT FWD MAIN ENTRY DOOR CUTOUT UPPER FWD EMERGENCY LIGHT INOP. REPLACED BATTERY, OPS CHECKS NORMAL.SDR UALA2009012700296Connector · looseEEL LIGHTING BY LAV 124 COMES ON AND OFF UNCOMMANDED. FOUND SUSPECTED LOOSE CONNECTOR FWD OF LAV 124 AISLE. RESECURED CONNECTOR. CYCLED EMERGENCY LIGHTS AND UNABLE TO REPRODUCE FAULT. CONSIDERED OK FOR FURTHER SERVICE.SDR DL76L090114Blade · failedFAILED OP 50103 7TH STAGE BLADE INSPECTION. BLADE TEAR. ENGINE CHANGE IN PROGRESS.SDR UALA2009012600274Slide · low pressureDOOR 2L SLIDE PRESSURE BELOW SERVICEABLE LIMIT. REPLACED 2L SLIDE.SDR UALA2009012600278Fuse · faultyIN SEAT EEL LIGHTS INOP AT RT 27 THROUGH 34. REMOVED DADO PANEL AT SEAT ROWS 27 THROUGH 30 AND REPLACED BAD FUSE IN POWER SUPPLY AND OPS CHECK GOOD.SDR UALA2009012600260Stiffener · crackedRIGHT WING LEADING EDGE CAVITY, FRONT VERTICAL ANGLE STIFFENER AT L/E STA 652 IS CRACKED. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW STIFFENER.SDR UALA2009012600261Housing · brokenRIGHT WING OVERWING SLIDE DOOR, DISCONNECT HOUSING IS BROKEN. REPLACED DISCONNECT HOUSING.SDR UALA2009012600262Seat Track · corrodedMAIN CABIN STA 808 RBL 54.5 SEAT TRACK CORRODED. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW SECTION OF SEAT TRACK.SDR UALA2009012600265Housing · crackedLT OVERWING SLIDE DISCONNECT HOUSING CRACKED. INSTALLED NEW DISCONNECT HOUSING.SDR UALA2009012600267Anti-Ice Valve · faultyLEFT ENG A-I VALVE LIGHT ILLUMINATED WITH SWITCH IN OFF POSITION. REPLACED ANTI-ICE VALVE & CONNECTOR. OPS CHECK NORMAL.SDR UALA2009012200243Retainer · crackedRT FWD OVERWING DOOR PRESSURE SEAL RETAINER CRACKED UPPR FWD CORNER. REPLACED THE RETAINER.SDR UALA2009012200244Latch · wornRIGHT OVERWING SLIDE COMPARTMENT DOOR LATCH NR 2 WORN AND HARD TO OPERATE. REPLACED THE DOOR LATCH.SDR UALA2009012100233Panel · damagedRT WING NR 7 LEADING EDGE SLAT CLOSURE PANEL DAMAGED. REINSTALLED REPAIRED PANEL. OPS CHECK NORMAL, FAIR GOOD. REPAIRED PER GN-MM 1-0-1-24.SDR UALA2009012100225Latch · damagedLEFT WING OVERWING SLIDE DOOR, NR 3 LATCH HAS GROOVE IN SLIDER. REPLACED LT OVERWING SLIDE DOOR NR 3 LATCH. OPS CHECKS GOOD.SDR UALA2009012100226Latch · gougedRT OVERWING SLIDE COMPARTMENT DOOR NR 2 LATCH GOUGED. REPLACED RT OVERWING SLIDE COMPARTMENT DOOR NR 2 LATCH.SDR UALA2009012100227Smoke Detector · no testAC-3 LAV SMOKE DETECTOR DOES NOT TEST. REPLACED AC-3 LAV SMOKE DETECTOR. OPS CHECKS NORMAL.SDR UALA2009012100228Door · crackedNR 1 ENGINE HAS A CRACKED THRUST REVERSER BLOCKER DOOR LOCATED AT THE 11 O'CLOCK POSITION (AFT OF FAN EXIT GUIDE VANES). BLOCKER FAN REVERSER SLEEVE DOOR REMOVED.SDR UALA2009012000224Actuator · failedAILERON LOCKOUT LIGHT IS ON. REPLACED RT OUTBOARD AILERON LOCKOUT ACTUATOR.SDR HALA2009011800025Fmu · malfunctionedETOPS SIGNIFICANT SYSTEM, BTB LT ENG WOULD NOT START W/ENG VALVE LIGHT ON. N2-28 PERCENT WITH FUEL ON, NO LIGHT OFF. REPLACED FMU PER TASK 73-21-01 OPS CKS AND LEAK CKS GOOD. OK FOR SERVICE.SDR UALA2009011900213Anti-Ice Valve · faultyLEFT ENG ANTI-ICE VALVE DISAGREE LIGHT ILLUMINATED WITH SWITCH IN THE "ON" POSITION. REPLACED NR 1 ENGINE INLET THERMAL ANTI-VALVE.SDR UALA2009012000218Transmitter · defectiveFUEL FLOW XMTR MAY BE READING A BIT HIGH. ALTHOUGH THIS DOESN'T AFFECT FUEL BURN IT DOES AFFECT FUEL FLOW INDICATION. SUSPECT FUEL FLOW TRANSMITTER IS INACCURATE. REPLACED TRANSMITTER. RAN ENG. OP CHECKS GOOD.SDR HALA2009011700024Relay · malfunctionedETOPS SIGNIFICANT SYSTEM, BTB UNABLE TO START LT ENG, ENG VALVE REMAINED
ILLUMINATED 26 PERCENT N2. PERFORMED FIM 76-11-00 FIGURE 104. REPLACED RELAY K168 (L FUEL IGN CONT), OPS CHECKED GOOD.SDR HALA2009011500021Blades · damagedETOPS SIGNIFICANT SYSTEM, FOUND NICKS ON BLADES 321 AND NR 22 ON NR 2 ENG BLADE NR 21 3/32 BY 1 3/4 INCH BLADE 22 1/16 BY 1 1/4 INCH. BLENDED FAN BLADES NR 21 AND NR 22 PER AMM 767 72-31-02. NICKS IN AREA A ON BOTH BLADES. EDDY CURRENTED. NO CRACK INDICATISDR UALA2009011500169Engine · oil consumptionOIL CONSUMPTION IS TRENDING UP. REPLACED NR 2 ENGINE FCOC. RUN CHECK NORMAL, NO LEAKS.