Pratt & Whitney PW4060
Service difficulty reports · 7,186
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009011900188Acoustic Liner · damagedNR 2 ENG ACOUSTIC LINER 8 O'CLOCK POS DAMAGED. NR 2 ENG INNER ACOUSTIC PANEL 8 O'CLOCK POSITION CRACKED 4.5 INCHES FORWARD OF LPC BLADES. REPLACED NR 2 ENG NOSE COWL.SDR UALA2009011400159Start Valve · failedLEFT STARTER VALVE STAYED ON AFTER SW RTRND TO AUTO RAN QRCT. REPLACED LEFT STARTER VALVE. SATISFACTORY ENGINE START. RAN ENGINE PER JRH.SDR UALA2009011500170Pump · faultyONE HOUR AFTER TAKEOFF, FUEL CONFIG LIGHT WITH RT TANK 4000 LBS LESS THAN LT. REPLACED RT FUEL OVERRIDE PUMP. OPS CHECK GOOD.SDR UALA2009011400155Slide · out of positionUPON 1L DOOR OPENING SLIDE PACK DROPPED OUT, DID NOT DEPLOY. SLIDE INSPECTION PERFORMED IAW AMM 25-66-01-6, NO DAMAGE FOUND. INSTALLED SLIDE. ALL SYSTEMS CHECKED, OPS NORMAL. ALL WORK HAS BEEN PERFORMED.SDR UALA2009011300150Disc · damagedLOW BOTTLE. DAMAGE TO BURST DISC CAUSING A SLOW LEAK. R&R BURST DISC.SDR UALA2009011200117Resolver · faultyLT THROTTLE AHEAD. THROTTLES NOT ALIGNED WITHIN 1 INCH AT KNOB AT SAME EPR AT LOW PWR, OK CRUISE AND CLIMB. EEC'S ON. LT THROTTLE FWD OF RT THROTTLE ABOUT ONE INCH IN CRUISE WITH MATCHING EPRS AND N1S. FOUND NR 2 ENG TLA RESOLVER OUT OF RANGE (34.2). ADJUSTED SDR UALA2009011200118Light · inoperativeFLOOR EEL LIGHT ADJACENT TO DR 1R INOP. INSTALLED NEW EEL STRIP, P S-CHECKED OK.SDR UALA2009011200119Wire Harness · faultyFLOOR EEL LIGHT AT SEAT 1EF INOP. REPAIRED FLEX HARNESS TO EEL LIGHT, OPS CHECKS GOOD.SDR UALA2009011200120Connector · looseFLOOR EEL LIGHT AT SEAT 5EF INOP. SECURED EEL'S CONNECTOR, OPS CHECKS OK.SDR UALA2009011200121Light · inoperativeFLOOR EEL LIGHT RT OF MID-GALLEY INOP. REPLACED EEL LIGHT. OPS CHECKS OKAY.SDR UALA2009011200122Light · inoperativeAFT GALLEY'S X AISLE EEL LIGHT INOP. REPLACED EEL LIGHT, OPS CHECKS GOOD.SDR DL76L090043Blade · failedNR 1 ENGINE DUE FAILED BORO 7 STG HPC. INSP 7TH STAGE HPC BLADE ROOT FOUND 1 BLADE DAMAGED .185 IN AREA C. BEYOND AMM LIMITS. NR 1 ENGINE CHANGE REQUIRED.SDR HALA2009011000010Seal · leakingETOPS SIGNIFICANT SYSTEM - SERVICED NR 2 ENG WITH 4 PINTS OF OIL. RAN ENG AND PERFORMED LEAK CK PER AMM 71-71-00 FOUND PMA SEALS LEAKING BEYOND LIMITS. FOUND PMA CARBON SEALS LEAKING. REPLACED SEALS ON NR 2 ENG AS PER BOEING MTC MANUAL TASK 72-61-05 LEAKS CKSSDR UALA2009011200106Sign · unsecureRT OVER WING EXIT SIGN OVER AISLE LENS ON AFT SIDE WILL NOT STAY ON LIGHT ASSY. SECURED IN PLACED WITH TAPE.SDR UALA2009011200132Aspirator · leakingASPIRATOR LEAKING. MFG DEFECT. REPLACED BARREL.SDR UALA2009010800082Switch · faultySUSPECT AIR-GRD PROBLEM. FOUND 200V AT PITOT HEAD ON GRD ENG'S OFF. REPLACED SYS 1 AIR-GROUND RELAY K552, LT PROBE HEAT TEST RELAY K643 & GEAR TILT RT MLG RELAY K10446. ACCOMPLISHED CONTINUITY CHECKS. REMOVED RELAYS K514, 515 & 516 AIR GROUND SYS RELAY ESTASDR UALA2009031000082Sensor · faultySUSPECT AIR-GRD PROBLEM. FOUND 200V AT CAPT'S PITOT HEAD ON GROUND ENG'S OFF. CONTINUING TO T-S BUT SUSPECT TILT SWITCH S10598 FAULTED. REPLACED SYS 1 AIR-GROUND RELAY K552, LT PROBE HEAT TEST RELAY K643 & GEAR TILT RIGHT GEAR RELAY K10446. ACCOMPLISHED CONTSDR UALA2009010600076O-Ring · damagedLOW BOTTLE PRESSURE. LEAKING AROUND GAUGE ADAPTER. R&R O-RING.SDR UALA2009010800079Barrel · defectiveLOW BOTTLE PRESSURE. BARREL NOT SEALING. REPLACED BARREL.SDR UALA2009031000076O-Ring · unserviceableLOW BOTTLE PRESSURE. LEAKING AROUND GAUGE ADAPTER. R & R O-RING.SDR UALA2009031000079Barrel · leakingLOW BOTTLE PRESSURE. BARREL NOT SEALING. REPLACED BARREL.SDR HALA2009010500005Filter · cloggedETOPS SIGNIFICANT SYS - L OIL FILTER STATUS MSG. REPLACED OIL FILTER NR 1 ENG. GRD RUN CK GOOD.SDR DL76L090022Engine · failedNR 1 ENGINE REPLACED DUE TO FAN EXIT CASE DAMAGE.SDR UALA2009010500046Actuator · faultyDURING START OF RT ENG, 'R FUEL SPAR VAL' EICAS MSG AND SPAR VLV LIGHT ILLUMINATED. ENG SUBSEQUENTLY SPOOLED DOWN. REPLACED ENG FUEL SHUTOFF ACTUATOR AND ACP ENG OPS CHECK.SDR UALA2009010500047Battery · dischargedEXTERIOR EMERGENCY LIGHTS INOP. REPLACED BULB. OPS CHECK GOOD AND ALLOWED BATTERIES TO CHARGE.SDR UALA2009010500048Light · inoperativeRT MID CLOSET FLOOR EEL INOP. REPLACED RT MID CLOSET FLOOR EEL LIGHT BAR AND OPS CHECK GOOD.SDR UALA2009010500036Pin · backed outSEAT 20 HJ EMERGENCY LIGHT INOP RELAMP NO HELP RED OVERWING EXIT. FOUND PUSHED BACK PIN, SECURED PIN AT CONNECTOR. OPS NORMAL.SDR UALA2009010500037Skin · delaminatedLT INBD ELEVATOR UPPER SURFACE OB END DELAMINATED. REMOVED DELAMINATED PLIES AND INSTALLED REPAIR.SDR UALA2009010500039Angle · crackedCRACKS FOUND ON NR1 PYLON CLOSEOUT ANGLE, 2ND FASTENER FROM INBD EDGE AT 0:00 POS AND 0900 POS. MAJOR REPAIR ACCOMPLISHED: STOPPED DRILLED CRACKS AND INSTALLED FILLER AND STRAP DOUBLER REPAIR.SDR UALA2009010500055Start Valve · faultyRT ENG STARTER EICAS MSG, TERMINATED START CYC. INSTALLED NEW START VALVE. ENGINE STARTER OPS NORMAL.SDR UALA2009010500038Slide · faultyLT OVERWING INFLATION HOSE IS FLATTENED 12 INCHES AT THE SLIDE COMPARTMENT ELBOW. SLIDE REPLACED.SDR UALA2009031000038Hose · failedLT OVERWING INFLATION HOSE IS FLATTENED 12 INCHES AT THE SLIDE COMPARTMENT ELBOW. SLIDE REPLACED.SDR UALA2009010500026Skin · crackedCRACK ON UPPER FWD RADIUS ON PANEL CUTOUT NR 2 PYLON INBOARD SIDE, PANEL 446BL. MAJOR REPAIR ACCOMPLISHED, STOP DRILLED 2 EA CRACKS. INSTALLED REPAIR DOUBLERS.SDR UALA2009010500027Housing · brokenLEFT OVERWING SLIDE COMPARTMENT, DISCONNECT HOUSING IS BROKEN. REPLACED DISCONNECT HOUSING. REINSTALLED LT DISCONNECT CAM ASSY. EXAMINED INFLATION CABLE FOR FREEDOM OF MOVEMENT, CHECKS GOOD.SDR UALA2009010500028Slide · unserviceableDOOR L1 SLIDE COMING UNLACED. INSTALLED NEW SLIDE AT DOOR L-1.SDR UALA2009010500053Switch · failedFUEL CONFIG EICAS AND LIGHT. RT TANK 2.6 LOW. DURING BALANCE PROCEDURE THE RT AFT FUEL PUMP EICAS NOT DISPLAYED. NEEDS SWITCH ASSY. REMOVED AND REPLACED AFT PRESSURE SWITCH. OPS CKS NORMAL.SDR UALA2009010200024Hydraulic Line · leakingHYD LEAK FROM LT OTBD AILERON PCU HYD LINE. TUBE REPAIRED WITH FITTING. LEAK CHECK ACCOMPLISHED. LT HYD SYS SERVICED TO GREEN BAND.SDR UALA2009010200010Actuator · disconnectedL ENG EEC C1 AND L ENG CONTROL STATUS MESSAGES ON THE WAY TO THE GATE. INSTALLED NEW SVA NR 1 ENG. INSTALLED NEW SVA NR 1 ENG.SDR UALA2009010200003Wire · chafedNR 1 ENGINE UPPER PYLON POSSIBLE FIRE LOOP HARNESS RED 01TR-W-20 CHAFED 2 PLACES. FOUND WIRE IN QUESTION TO BE W0380-01TR (W)-20 USED FOR EVB WIRE TYPE RQ. REPAIRED SHIELD WIRE. RESECURED WIRES, CLAMPS AND PROTECTED WITH TEFLON & FIBERGLASS TAPE. REPAIRED SDR UALA2008123107053Eec · faultyLT ENG CONTROL EICAS MSG DISPLAYED ON LANDING. REPLACED NR 1 ENG EEC.SDR HALA2008122900911Oil System · lowOPEN, ETOPS SIGNIFICANT SYSTEM, NR 1 ENG REQUIRED 10 PTS OIL SERVICE (.366PPH). REPAIR IN WORK.SDR UALA2008123007044Oven · contaminatedELECTRICAL ODOR IN CABIN. FLIGHT DIVERTED. DOOR AREA HEATER CB PULLED R12 ON OVERHEAD P11 PANEL TO SEE IF ODOR GOES AWAY. THERE IS NO SIGN OF ANY SMOKE. REPLACED RT AFT DOOR HEATER. WARMING OVEN DIRECTLY BELOW W51 HAD MELTED PLASTIC INSIDE CAUSING BURNED OSDR UALA2008122907027Light · inoperativeRT EXTERIOR EMERG LIGHT INOP RT SLIDE LIGHT. RELAMPED, OPS OK.SDR UALA2008122907036Relay · faultyUNABLE TO FUEL ACFT, FUELING VALVES (ALL) DO NOT OPEN AUTOMATICALLY. RPL RELAYS K357 FUELING PWR TRANS ON THE P36 AND K181 OVERFILL CONT ON THE P36. ALSO RPL THE ASSY FUEL LEVEL SENSOR CARD. RPL RELAY K180. REPLACED FUEL QTY PROCESSOR. FUELER WAS ABLE TO PRSDR HALA2008122700912Oil System · lowETOPS SIGNIFICANT SYSTEM, NR 2 ENG REQ 4 PINTS OF OIL. ACP VISUAL INSP OF NR 2 ENG, NO LEAKS NOTED OK FOR
SERVICE.SDR HALA2008122700913Oil System · lowETOPS SIGNIFICANT SYSTEM, NR 2 ENG REQ 4 PINTS OF OIL. ACP VISUAL INSP OF NR 2 ENG. NO LEAKS NOTED OK FOR SERVICE.SDR UALA2008122607013Oven · odorELECTRICAL ODOR REPORTED IN AFT GALLEY. NO ODOR WITH GALLEY POWER OFF. CHECKED IN CEILING ABOVE AFT GALLEY ALL OK. FOUND WARMING OVEN W51 HAD MELTED PLASTIC INSIDE AND STRONG BURNED ODOR. CLEANED OVEN. RAN FOR SEVERAL HOURS. CHECKED OK.SDR HALA2008122600912Indication Sys · trippedETOPS SIGNIFICANT SYSTEM, R IDG VALVE STATUS MSG. CHECKED IDG FILTER DPI FOR POPPED CONDITION, CHECKED NORMAL. CHECKED SERVICE OF RT IDG, CHECKED GOOD. PERFORMED FIM 31-41-00, FIG 109, CLEARED EICAS MESSAGE. OK FOR SERVICE.SDR UALA2008123007050Charger · faultyAPU SHUTS DOWN WITH ELEC OR PNEUMATIC LOAD. REPLACED BATTERY CHARGER AS PER SERVICE TIP. CLEARED APU CONTROLLER OF ALL FAULTS. RAN ENG 3 TIMES TO PUT LOAD ON APU, AT MAX HAD 40 P.S.I. ALSO SERVICED APU OIL.SDR UALA2008122607009Wire · burnedFWD CARGO COMPARTMENT P35 POPPING CB`S AS FOLLOW: C171, C173, C167, C168 & C169. FOUND 24 WIRES BURNED OUT UNDER PNL PDU 7L. ALL WIRES ISOLATED AND AFFECTED PDU'S ELECT PLUGS REMOVED AND ISOLATED. FWD CARGO HDG SYS INOP. STARTED TO IDENTIFY WIRES WITH LABE
Back to Pratt & Whitney PW4060