Pratt & Whitney PW4090-3
Service difficulty reports · 2,638
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW40903' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW40903' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2024081600449Bearing Seal · leakingDUE TO THE INFLIGHT SHUTDOWN ENGINE #2 WINDMILLING INSPECTION REQUIRED IAW AMM TASK 72-00-00-210-809-N02 ENG2 SN. 222183 (TSI= 3082, CSI 348 CYC). OIL LEAK IN TAIL PIPE REVIEWED AND DETERMINED TO BE LEAKING NR 3 BEARING. SEAL. MX. PERFM. PG SNAPSHOT SHOW OIL PSDR CALA2017103003841Engine · surgesCREW REPORTS LEFT ENGINE SURGED, SURGE WAS AUDIBLE AND ENGINE HAD ROLLBACK, ENGINE RECOVERED AND OPERATED NORMALLY. ACCOMPLISHED FIM 71-05-00-810-819-N00 AND FIM TASK 71-05-00-810-819 BORO, MCD, AND GVI NO DEFECT NOTED. PER ENGINEERING REQUEST, ENGINE REPLACSDR CALA2016082395661Lamp · inoperativeSIDEWALL LIGHT INOPERATIVE 39ABC REPLACED THE LAMP, ALL OPS NOW SATISFACTORYSDR CALA2016082395662Control Unit · failedSAARU FAILURE, INERTIAL REFERENCE FAILURE, AIR DATA FAILURE OR TOTAL FAILURE OF THE LRU OR AIRPLANE TYPE MISCOMPARE. REPLACED SAARU AS REQ, AND UPDATED OPC SOFTWARE. SAARU MESSAGE EXTINGUISHED. AMM 34-21-02SDR CALA2016080995608Light · inoperativeEMERGENCY LIGHTS AT MID GALLEY LIGHTS BROKEN. LIGHTS LOCATED AT DIVIDERS AT L2 AND R2 DOORS. REPLACED LIGHTS IAW MM 33-51-05-201 OPS CHECKED OK.SDR CALA2016080995607Lamp · brokenLOWER EMERGENCY LIGHT AT SEAT 9H HAS A BROKEN LAMP AND LENS MISSING. REPLACED LIGHT ASSY IAW MM 33-51-00. OPS CHECKED GOOD.SDR CALA2016072895589Lamp · inoperativeEMERGENCY EXIT LIGHTS FLASHING AT L4 DOOR. REPLACED THE LAMP, OPS CHECKED GOODSDR CALA2016072895590Pin · brokenSLIDE PI-PIN ON TOP OF FWD LAVE DOOR THAT SLIDES THRU TRACK IN BROKEN R & R ROD, SPRING ASSY, GUIDE TRIM ASSY.SDR CALA2016072595581Ballast · odorCREW REPORTED PERSISTANT ELECTRICAL ODOR FROM L3 DOOR AREA. RECIRCULATION FANS ON AND OFF NO CHANGE. TURNED CABIN LIGHTS TO NIGHT MODE AND THE ODOR DISAPPATED. AFTER APPROX 6 HRS ELECTRICAL ODOR RETURNED. ACCOMPLISHED INSPECTION IAW MM 05-51-50. NO ABNORMASDR CALA2016072295572Power Supply · odorELECTRICAL BURNING ODOR DETECTED AT THE L3 DOOR. ON ARRIVAL, ODOR DISSIPATED, OPERATED ALL FANS AND INSPECTED AREA FOR LIGHTS, ALL OK. RAN ENGINES WITH NO ODOR. MORE DETAILED INSPECTION, CHANGED L3 DOOR EMERGENCY LIGHT BATTERY AND POWER PACKSDR CALA2016072195569Power Supply · failedCIRCUIT BREAKER FOR EMERGENCY LIGHTS AT POSITION 3L IS TRIPPED. L3 DOOR EMERGENCY LIGHT CIRCUIT BREAKER FAULT WAS CAUSED BY FAILURE OF THE LLAR POWER SUPPLY UNIT AND BATTERY WHICH HAD A STRONG ELECRICAL ODOR. ASSY REPLACED IAW AMM 33-29- 01 AND TESTED OPS SDR CALA2016071895567Chiller · odorSTRONG ELECTRICAL ODOR THROUGH ENTIRE AIRCRAFT, LASTED 30 MINUTES OF FLIGHT. REMOVED AND REPLACED CHILLER C21 IAW AMM 25-33-01. PERFORMED INSPECTION OF CABIN NO ODOR NOTED.SDR CALA2016070895511Precooler · damagedSOUND & VIBRATION OCCURED FOR A FEW SECONDS DURING CLIMB AT 10K FT, NOISE HEARD AT DOORS L1, 2, AND R2. LOW RUMBLING SOUND AND VIBRATION. DISSIPATED THEN HEARD AGAIN IN CRUISE ROW 8-10 UNDER FLOORBOARD. IAW AMM 05-51-38-201 AIRFRAME VIBRATION CONDITIONAL INSDR CALA2016070895512Ballast · odorAPPROXIMATELY 3-4 HOURS INTO FLIGHT, CREW REPORTED THE R3 LAVATORY SMOKE DETECTOR SOUNDED. REPLACED BALLAST IAW WD 33-29-41 P1A. OPS CHECKED OK. NO ODORS.SDR CALA2016070195496Duct · damagedSOUND-VIBRATION OCCURED FOR A FEW SECONDS DURING CLIMB AT 10K FT CREW REPORT NOISE HEARD AT DR1L, 2L, AND 2R. LOW RUMBLING SOUND AND VIBRATION. DISSIPATED THEN HEARD AGAIN IN CRUISE ROW 8-10 UNDER FLOORBOARD, NOT AS LOUD THOUGH. IAW AMM 05-51-38-201 AIRFRAMESDR CALA2016061595451Structure · dentedDENT BETWEEN FRAME 676 LT AND FRAME 679 LT, STR39L AND STR 40L DIMENSION L 6.5" X W 6.0" X
D 0.216" REF ECRA 5300-02342, PERFORMED PARTS 1 AND 2 OF ECRA.SDR CALA2016061395445Battery · dischargedDOOR 1R EPAS LIGHTS NOT FLASHING. REPLACED 2 EACH, 9 VOLT BATTERY IAW 51-11-20. LIGHTS OPS CK GOOD.SDR CALA2016061395443Structure · dentedDENT BETWEEN FRAME 676 LT AND FRAME 679 LT, STR 39L AND STR 40L DIMENSION L6.5 IN X W6.0 IN DEPTH 0.216 IN CUTOUT DAMAGE, REF SRM 5 3-00-01, REPAIR-7 AND NR 6696869.SDR CALA2016060795437Unknown · smokeVERY LIGHT GREY SMOKE & BURNING ODOR IN AFT GALLEY OF ACFT. HALON BOTTLE EXTINGUISHED IN AREA & SMELL SUBSIDED. ACCOMPLISHED SMOKE INSPECTION IAW 05-51-50 WITH NO DEFECTS NOTED. FORM 46.6020 FILLED OUT.SDR CALA2016060895440Unknown · smokeFLIGHT ATTEND REPORTED VISIBLE SMOKE & ODOR FROM AFT GALLEY VENT. HALON EXT DISCHARGED INTO VENT. ALL AC FEED CB'S PULLED TO REMOVE POWER FROM GALLEY. COMPLIED WITH CONDITIONAL INSPECTION AS REQUESTED. REF SEQ 5382009 & LM 4914. NO EVIDENCE OF SMOKE OR SMSDR CALA2016060695435Light · inoperativeEXIT PATH LIGHT OUT AT 20D. REPLACED EMER EXIT PATH LIGHT LENS AT 20D IAW AMM 33-51-05. ALL OPERATIONS NOW NORMAL.SDR CALA2016052095376Power Supply · inoperativeEMERGENCY LIGHTS IN ECONOMY CLASS, SEATS FAILED TO ILLUMINATE DURING TEST. REPLACED POWER SUPPLY & BATTERY PACK IAW AMM 33-51-06. SYS OP CHECKED NORMAL, ALL LIGHTS FUNCTIONING.SDR CALA2016050495335Seat Track · chafedCABIN BS 1046 - 1200, LBL 11 SEAT TRACK OTBD FLANGE, FOUND SURFACE CHAFING. SURFACE CHAFING SMOOTHED OUT IAW SRM 51-10-02 & PROTECTED IAW SRM 51-20-01.SDR CALA2016040795257Wire · brokenFOUND BROKEN WIRE UNDER SEAT 27G DURING EMER LIGHT CHECK, SPLICED WIRE. PERFORMED OPERATIONS CHECK, CHECKED GOOD IAW SWPM 20-10-13.SDR CALA2016040795260Actuator · malfunctionedENGINE 222047 EXPERIENCED EGT OVERTEMP & SURGE AT LANDING, DETECTED & REPORTED BY CREW. REPLACED SVA IAW AMM 75-31-02 C02 PG4XX. ENG 2 FMU REPLACED. ENG 2 FF XMTR REPLACED. WIRING CHECKED IAW FIM 75-31 TASK 811 ENG 2 WET MOTOR, FUEL SYS PRIMING & POST TESTSDR CALA2016033195236Engine · vibrationHEAVY VIBRATION 5 HRS INTO FLIGHT. SPARKS OBSERVED BY DEADHEADING PILOTS FROM TAIL CONE. ALL ENG PARAMETERS DISPLAY NORMAL ON EICAS, HOWEVER, WHEN POWER REDUCED TO 65% N1 VIBRATION CEASED. REPLACED NR 1 ENG IAW AMM 71-00-02 PG 401.SDR CALA2016032395227Light · inoperativePOSITION SEAT 36KJH, CEILING EMER LIGHTS FOUND NIL ILLUMINATION. REPLACED EMER AREA LIGHT LAMP ON POSITION SEAT 36KJH & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM 33-51-03.SDR CALA2016032195221Battery Pack · dischargedDOOR 4R FWD M33408 EMER LIGHT FAILED ON BATTERY CAPACITANCE TEST. REPLACED DOOR 4R FWD M33408 EMER LIGHT BATTERY PACK & CARRIED OUT EMER LIGHT TEST, FOUND NORMAL IAW AMM 33-51-00.SDR CALA2016032195222Light · inoperativePOSITION SEAT 9AB, CEILING EMER LIGHTS FOUND NO ILLUMINATION. REPLACED SEAT 9AB CEILING AREA EMER LIGHT LAMP & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM 33-51-03.SDR CALA2016032195223Battery Pack · dischargedDOOR 2L FWD M33096 EMER LIGHT FAILED ON BATTERY CAPACITANCE TEST. REPLACED DOOR 2L FWD M33096 EMER LIGHT BATTERY PACK & CARRIED OUT EMER LIGHT TEST, FOUND NORMAL IAW AMM 33-51-00.SDR CALA2016022995177Battery Pack · failedDOOR 2 RT M33098 AFT EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 2 RT M33098 AFT EMER LIGHT BATTERY PACK & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995178Battery Pack · failedDOOR 4 LT M33407 FWD EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 4 LT M33407 FWD EMER LIGHT BATTERY PACK & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995179Battery Pack · failedDOOR 3 LT M33405 AFT EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 3 LT M33405 AFT EMER LIGHT BATTERY PACK & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995180Battery Pack · failedDOOR 3 RT M33404 FWD EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 3 RT M33404 FWD EMER LIGHT BATTERY PACK & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995181Battery Pack · failedDOOR 2 LT M33096 FWD EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 2 LT M33096 FWD EMER LIGHT BATTERY PACK & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995182Battery Pack · failedDOOR 3 RT M33401 AFT EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 3 RT M33401 AFT EMER LIGHT BATTERY PACK & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995183Battery Pack · failedDOOR 4 RT M33409 AFT EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 4 RT M33409 AFT EMER LIGHT BATTERY PACK & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995184Battery Pack · failedDOOR 1 RT M33094 EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 1 RT M33094 EMER LIGHT BATTERY PACK & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995185Battery Pack · failedDOOR 4 RT M33408 FWD EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 4 RT M33408 FWD EMER LIGHT BATTERY PACK & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995186Battery Pack · failedDOOR 1 LT M33093 FWD EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 1 LT M33093 FWD EMER LIGHT BATTERY PACK & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995187Battery Pack · failedDOOR 1 LT M33424 AFT EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 1 LT M33424 AFT EMER LIGHT BATTERY PACK & PERFORMED OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995188Battery Pack · failedDOOR 2 LT M33099 AFT EMER LIGHT BATTERY CAPACITY CHECK FAILED. DOOR 2 LT M33099 AFT EMER LIGHT BATTERY PACK REPLACED. CARRIED OUT OPERATIONS TEST & FOUND NORMAL IAW AMM.SDR CALA2016022995189Battery Pack · failedDOOR 3 LT M33400 FWD EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED EMER LIGHT BATTERY PACK ON DOOR 3 FWD & CARRIED OUT OPERATIONAL TEST FOUND NORMAL IAW AMM.SDR CALA2016022495134Oven · contaminatedBUS CLASS GALLEY OVEN 31 SMOKING, CABIN & VENT NOT CLEARING AIR. INADEQUATE STOWAGE OF FOOD IN THE TOP SHELF, FOOD TRAYS STOWED WITHOUT LID. LED TO CONTAMINATION WITH CINNABON ON THE GRILL THAT PROTECTS THE FAN & HEATER ELEMENT. TOP OF THE OVEN CLEANED AS PSDR CALA2016022495131Cooling Fan · faultyEQUIPMENT COOLING ADVISORY & EQUIP COOLING VENT FAN STATUS MSG DISPLAYED, AT BLOCK IN. CREW ALSO NOTICED AN ELEC ODOR. REPLACED EQUIP COOLING FAN IAW MM 21-27-20. OPERATIONS CHECKED NORMAL.SDR CALA2016021695111Socket · burnedELECTRICAL SMELL IN CABIN CONSISTENTLY AT LAVATORY AT 2L, NOTICED AT LAVATORY 3L & AROUND ROWS 25 - 27. ACCOMPLISHED AMM 05-51-50, TO STEP C T. FOUND A BURNED SOCKET ON THE MIRROR LIGHT FIXTURE AT DOOR 2L, ISOLATED LIGHT BALLAST FROM THE SOCKET. ALSO USED FSDR CALA2016020495087Warning Message · intermittentPRIOR TO DEPARTURE, CREW CALL RT ENG VIB MONITOR MSG DISPLAYED. CYCLED BREAKER, NO HELP. ACCOMPLISHED FIM 77-31-826, DETERMINED INTERMITTENT FAULT, NO MSG LATCHED.SDR CALA2016020395074Battery Pack · dischargedDOOR 2 PROXIMITY EXIT LIGHT FWD, FOUND INOPERATIVE. DOOR 2 RT M33097 FWD BATTERY PACK REPLACED & OPERATIONS TEST CARRIED OUT, FOUND NORMAL IAW AMM 33-51-06.SDR CALA2016020395075Battery Pack · dischargedDOOR 3 RT PROXIMITY EXIT LIGHT AFT FOUND INOPERATIVE. DOOR 3 RT M33401 AFT BATTERY PACK REPLACED & OPERATIONS TEST CARRIED OUT FOUND NORMAL IAW AMM 33-51-06.SDR CALA2016020395073Receptacle · burnedLAVATORY 3L BURNING SMELL. ACCOMPLISHED INSPECTIONS IAW MM 05-51-50. FOUND MIRROR LIGHT FWD LAMP RECEPTACLE BURNT & CAUSING ODOR. REMOVED LAMP, DISCONNECTED & SAFETIED BALLAST M004 CONNECTOR IAW STANDARD PRACTICES. COMPLIED WITH MEL.
Back to Pratt & Whitney PW4090-3