Rolls-Royce RB211-535E4 series
Service difficulty reports · 2,136
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'RB211535E4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'RB211535E4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA120423014Monitor · inoperative(CAN) ABOUT AN HOUR FROM DESTINATION THE PILOTS SMELLED AN ELECTRICAL ODOR IN THE COCKPIT FOR A SHORT DURATION. THERE WERE NO ABNORMAL INDICATIONS AND THE ODOR DISSIPATED QUICKLY. THE CAPTAIN ASKED THE F/A IF THEY SMELLED ANYTHING AND THEY REPORTED THAT THEYSDR USAA2012041900004Flow Valve · debondedPHL - FLT 1451 PHL TO PUJ. ABORT TAKEOFF AT 80 KNOTS. AT 80 KNOTS, DID NOT HAVE 1.4 EPR ON RIGHT ENGINE. AT 80 KNOTS, RIGHT EEC LIGHT & RIGHT ENGINE LIMITER LIGHT ON. REPLACED RIGHT FUEL FLOW GOVERNOR. OP'S & LEAK CHECK OK. P4 ORIFICE DEBONDED.SDR USAA2012040800004Sensor · leakingFLT 1579, ON DESCENT, AS POWER WAS ADVANCED TO LEVEL OFF AT 12,000, ALL 3 COCKPIT OCCUPANTS NOTICED A DIRTY SOCK ODOR. AFTER ABOUT 1 MINUTE TURNED OFF RIGHT PACK. ODOR PERSISTED. TURNED OFF LEFT PACK AND ODOR DISAPPEARED QUICKLY. ODOR NOT NOTICED IN CASDR CA120329006Hose · ruptured(CAN) CREW CALLED DISPATCH 1 HR OUT TO ADVISE THEY HAD LOST LT HYDRAULIC PRESSURE & QTY. ELECTED TO CONTINUE TO DESTINATION. HAD ALTERNATE GEAR AND FLAP EXTENSION, NO EMERGENCY WAS DECLARED. MAINTENANCE DISCOVERED MLG DOWN LOCK ACTUATOR HAS A RUPTURED HOSE.SDR CA120316007Bearing · worn(CAN) DURING A LIGHTNING STRIKE INSPECTION, WHERE THE EXIT POINT WAS ON THE LT ELEVATOR, THE ELEVATOR PCA WERE INSPECTED AS REQUIRED. THE LT ELEVATOR CENTER PCA LINK ASSY BEARING WAS FOUND TO BE VERY LOOSE AND WORN, UNRELATED TO THE LIGHTNING STRIKE. THE BEARSDR CA120314006Line · leaking(CAN) AFTER GEAR DOWN SELECTION ON APPROACH, THE CREW NOTICED THE LT HYD QTY WAS DEPLETING. AFTER LANDING, THE CREW REPORTED THE LT HYD SYSTEM WAS EMPTY. MAINTENANCE INVESTIGATION FOUND THAT THE RETURN FLEX LINE FROM THE LT DOWNLOCK ACTUATOR WAS LEAKING, IPC SDR CA120313004Bolt · broken(CAN) DURING A ROUTINE ACFT INSPECTION MAINTENANCE NOTICED A BROKEN THROUGH BOLT ON THE NR 1 MAIN WHEEL. NUT AND TAIL OF BOLT WERE NOT FOUND. NR 1 MAIN WHEEL REPLACED.SDR NOCA02612Unknown · fireEXPERIENCED A TAIL PIPE FIRE DURING THE STEPS IN REMOVING THE NR 2 ENGINE (S/N 31811). THE AIRCRAFT SUFFERED SIGNIFICANT DAMAGE TO THE RT ENGINE PYLON, SURROUNDING UNDER WING PANELS, RT INBOARD FLAP CANOE AND THE RT INBOARD FLAP. A PRELIMINARY INVESTIGATION SDR USAA2012022700002Blade · out of balanceFLT 1079 EN ROUTE. WHILE IN CRUISE, RIGHT ENGINE VIBRATION HIGH, READS 2.8 WITH NO EICAS MSG. ENG INDICATIONS WERE NORMAL. VIBRATION RETURNED BELOW 2.5 WITH THRUST LEVER RETARDED. MAINTENANCE ACCOMPLISHED SATISFACTORY ALTERNATE FAN TRIM BALANCE PROCEDURE.SDR CA120228016Ballast · overheated(CAN) AIRCRAFT RETURNED TO DEPARTURE AIRPORT DUE TO AN ELECTRICAL ODOR IN THE FORWARD LAVATORY. CREW PULLED APPROPRIATE CIRCUIT BREAKERS TO ISOLATE AND RETURNED WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTION DISCOVERED THE FORWARD L1 LAVATORY LIGHT BALLASTSDR CA120222006Line · cracked(CAN) CREW REPORTED A HYD FLUID LEAK FROM THE NR 1 ENGINE PYLON AND THE NR 1 THRUST REVERSER INOPERATIVE. MAINTENANCE DISCOVERED THE PRESSURE RETURN LINE FROM THE LT THRUST REVERSER CONTROL VALVE CRACKED. PN 271N6311-1151, IPC 29-11-51-45 -585. MAINTENANCE RSDR FDEA201202080516Control Unit · failedCLIMBING THROUGH 16,000 FT RECEIVED A MASTER CAUTION AND SIMULTANEOUS RT ENGINE EEC AND RT ENGINE LIMITER EICAS MESSAGE WITH RED EXCEEDENCE INDICATIONS ON EGT AND N2. R & R RT ENGINE DEDICATED GENERATOR REF MM 73-21-08-4 AND RT ENGINE DEDICATED GENERATOR CSDR USAA2012020100012Bolt · looseCLT FLT 885 EN ROUTE CLT TO CUN. LEFT ENGINE LO OIL PRESS LIGHT. LEFT ENGINE OIL QUANTITY 0. COMPLIED WITH QRH PROCEDURE TO SHUT DOWN LEFT ENGINE. FLIGHT RETURNED TO CLT AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED THE LEFT ENGINE. ALL ENGSDR WOWY2012012601Fuel Control · unserviceableDISCOVERED OCCURRENCE WHEN A UNIT WAS RETURNED FOR AN N1 OVERSPEED EVENT. UNIT WAS RETURNED THOUGH THE REPAIR STATION AND INVESTIGATED AT MFG. HOWEVER, WE RECENTLY DISCOVERED THAT THE EVENT HAD OCCURRED ON THE 21ST OF MAY 2011. THE UNIT WAS FOUND TO HAVE A FSDR CA120126011Conduit · short(CAN) DURING TAXI THE ANTI-SKID WARNING LIGHT ILLUMINATED INTERMITTENTLY. THE ANTI-SKID SYS WAS DEFERRED IAW THE MEL 32-42-01-1. THERE WAS SIMILAR OCCURRENCE ON 22 DEC 2011 ON THIS SAME ACFT WHICH WAS REPORTED ON SDR 20111228002. AT THE NEXT MAINTENANCE OPPOSDR CA111228002Clamp · broken(CAN) DURING TAXI THE ANTI-SKID WARNING LIGHT ILLUMINATED. THE ANTI-SKID SYSTEM WAS DEFERRED IAW THE MEL 32-42-01-1 AND THE ACFT RETURNED TO A MAINTENANCE BASE. INVESTIGATION REVEALED THAT CLAMP ASSY, PN BC1083-074S, AIPC 32-61-52-02H, ITEM 747, FAILED SPECIFSDR FDEA201112025132Battery Pack · inoperativeRT EMERGENCY EXIT LIGHTS DO NOT TEST. R & R BATTERY PACKS.SDR NOCA11011Unknown · malfunctionedNR 2 ENGINE HAD A LAG IN POWER DURING DESCENT INTO BWI. WHICH CAUSED THE A/C TO YAW AUTOTHROTTLES WERE ENGAGED. ITEM REMAINS OPEN.SDR IPXA11570580Skin · dentedDENT ON FUSELAGE SKIN PANEL BS 297-439 S4L TO 4R. TRIMMED OUT DENT AND ACCOMPLISHED REQUIRED INSPECTONS, FABRICATED DOUBLER AND INSTALLED IAW EA 111367 EO B757-5330-44963-A.SDR IPXA11569606Engine · vibrationLT ENGINE N3 VIBRATION INDICATED 2.7 DURING CLIMB FOR 340-370. RETURNED TO NORMAL RANGE AFTER LEVEL OFF. NO OTHER VIBRATIONS NOTED DURING RETURN. N3 91 PERCENT, N2 90 PERCENT, EGT 710. IAW TECH ALERT K151367 REINSTALLED ORIGINAL BAL WEIGHTS TO PREVIOUS BALSDR FDEA201109083754Engine · malfunctionedCLIMBING THROUGH 15000' AGL HEARD A LOUD BOOM ACCOMPANIED BY AN ACFT SHUTTER. IMMEDIATELY, SMELLED A SLIGHT SMOKEY ODOR, WHICH WENT AWAY AFTER 10 SECONDS. RETURNED TO AIRPORT FOR AN UNEVENTFUL LANDING. ALL ENGINE PARAMETERS AND FLT CHARACTERISTICS SEEMED NSDR USAA2011081800008Seal · leakingFLT 1043 ENROUTE, RIGHT ENGINE OVERHEATING. THE CREW POWERED BACK THE RIGHT ENGINE AND DECLARED AN EMERGENCY. THE FLIGHT DIVERTED TO PLS AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTED AND FOUND RING SEAL CLAMP LOOSE ON HP2 DUCT OFF TAKE. REPLASDR IPXA11568428Engine · fireRT ENGINE FIRE IN FLT, QRH PROCEDURES FOLLOWED, ENG SHUTDOWN. ACFT OOS.SDR IPXA1568428Fire Detector · false activationRT ENGINE FIRE IN FLT QRH PROCEDURES FOLLOWED, ENG SHUTDOWN. AC OOS. FIRE BOTTLES 1 & 2 DISCHARGED. R & R ENGINE FIRE BOTTLE NR 1 AND NR 2 IAW AMM 26-21-01-4. TESTS SATISFACTORY. INSPECTED RT ENGINE FOR SIGNS OF FIRE OR OVERHEAT AND NO DAMAGE FOUND. ACCOMSDR FDEA201107262945Pressure Switch · inoperativeDURING TAKEOFF, GOT LT OIL FILTER EICAS AT 80 KTS. DURING TAXI BACK, DID NOT HAVE ANY OTHER INDICATIONS. EICAS MESSAGE STAYED ON THROUGH SHUTDOWN. REPEAT. FOUND INOP LT ENG SCAVENGER OIL FILTER DIFFERENTIAL PRESSURE SWITCH, R & R IAW MM 79-35-02-4 AND TESTSDR AALA20110712HNL01Governor · failedHNL - CREW REPORTED NUMBER 2 ENGINE UNABLE TO MAKE CLIMB POWER WITH AT ENGAGED. FUEL FLOW WAS MUCH LESS AT LOW POWER SETTINGS. TURNED OFF EEC WITH NO CHANGES. EMERGENCY DECLARED FLIGHT RETURNED HNL LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. RSDR AALA20110708SJU01Compressor · stalledSJU INFLIGHT STT-JFK. CREW REPORTED ON CLIMBOUT RIGHT ENGINE COMPRESSOR STALLS. RETARDING RIGHT THROTTLE AND COMPRESSOR STALL CEASED. EMERGENCY DECLARED FLIGHT DIVERTED SJU LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED RIGHT ENGINE AT SSDR AALA20110708LGW01Plug · missingSNN - INFLIGHT-JFK-MAN. CREW REPORTED RIGHT ENGINE LOSS OF OIL PRESSURE AND QUANTITY. RIGHT ENGINE SHUTDOWN (SINGLE ENGINE TIME 80 MINS). EMERGENCY DECLARED FLIGHT DIVERTED SNN LANDED WITHOUT INCIDENT. FOUND GEARBOX CORE PLUG IN COWLING. RE-SECURED PLUG. SDR IPXA11567316Floor Panel · damagedINSPECTION TYPE:C, CK MAIN CABIN FLOOR PANEL NR231 XAF, FABRICATED NEW FLOOR BOARD IAW EO 757-5320-9692-G ON WO 21617/1000-0007.SDR IPXA11567317Frame · wornINSPECTION TYPE:C, CK MAIN CARGO FRAME AT BS 1540 INBD FLANGE HAS WEAR BETWEEN STR 15-16R. REPAIRED FRAME DAMAGE IAW EA 110577.SDR FDEA201106102188Tube · crackedON TAKEOFF ALL WAS NORMAL AT 1000 AGL/3800 MSL THE RT EPR GAGE WAS SLIGHTLY HIGHER THAN THE LT EPR. AS WE CLIMBED, THE LT EPR CONTINUED PROGRESSIVELY GET HIGHER (BIGGER SPLIT) N1 EGT N2, N3. FF APPEARED CORRECT. NO QRH PROCEDURES FOR EPR GAGE SO COMPLIED WISDR IPXA11567576Frame · dentedINSPECTION TYPE:C, AFT PIT BS 1320 FRAME IN DENTED ON INNER FLANGE AT STR 25L. REMOVED DAMAGE AND REPAIRED FRAME SECTION IAW SRM 53-00-07-2R, REPAIR 5, DET 3.SDR IPXA11566987Control Unit · inoperativeEMERGENCY DECLARED - L/E SLAT SYS EICAS MESSAGE L/E SLAT DISAGREE DISPLAYED WITH FLAP LEVER IN 1. BOTH FLAP POINTERS INDICATED 1/2 LOWERED FLAPS WITH ALTERNATE FLAP SECURED. TROUBLESHOT IAW FIM 27-81-00, BLOCK 1 & 26. FOUND FS CK NR 2 FAULT. R & R FSCU IAWSDR IPXA1567369Beam · corrodedINSPECTION TYPE:C1, FLOORBEAM AT STA 1040 +15" RBL 26-45 CORRODED. FABRICATED FLOORBEAM AND INSTALLED IAW SRM 5300-52-1A.SDR IPXA11566966Floor Panel · damagedINSPECTION TYPE:C1, MAIN CARGO COMPARTMENT FLOOR PANEL 242XFF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR FDEA201105251985Connector · malfunctionedDIVERTED, DUE TO HEAVY VIBRATIONS FROM LT ENGINE IN CLIMB. REDUCED POWER TO IDLE AND VIBRATIONS REDUCED TO ACCEPTABLE LEVEL (DID NOT SHUTDOWN). INSPECTED CHIP DETECTOR AND OIL FILTER, NO DEFECTS NOTED REF AMM 79-21-00, INSPECTED ENGINE COWL, LP COMPRESSOR BSDR IPXA11566969Floor Panel · damagedINSPECTION TYPE:C1, MAIN CARGO COMPARTMENT FLOOR PANEL 242XAF IS DAMAGED. FABRICATED NEW FLOOR PANEL 242XAF IAW EO B757-5320-9692-G.SDR IPXA11566970Floor Panel · damagedINSPECTION TYPE:C1, MAIN CABIN FLOOR PANEL 241XGF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA11566971Floor Panel · damagedINSPECTION TYPE:C1, MAIN CARGO COMPARTMENT FLOOR PANEL 241XDF IS DAMAGED FABRICATED NEW FLOOR PANEL 241XDF IAW EO B757-5320-9692-G.SDR IPXA11566972Floor Panel · damagedINSPECTION TYPE:C1, MAIN CARGO COMPARTMENT FLOOR PANEL NR251XFF IS DAMAGED AS MARKED. FABRICATED REPLACEMENT FLOOR PANEL NR251XFF IAW B757-5320-9692-G.SDR IPXA11566973Floor Panel · damagedINSPECTION TYPE:C1, MAIN CARGO COMPARTMENT FLOOR PANEL 241XAF IS DAMAGED. FABRICATED NEW FLOOR PANEL 241XAF IAW EO B757-5320-9692-G.SDR IPXA11566974Floor Panel · damagedINSPECTION TYPE:C1, MAIN CARGO COMPARTMENT FLOOR PANEL 242XKF IS DAMAGED. FABRICATED NEW FLOOR PANEL 242XKF IAW EO B757-5320-9692-G.SDR IPXA11566975Floor Panel · damagedINSPECTION TYPE:C1, MAIN CARGO COMPARTMENT FLOOR PANEL 242XMF IS DAMAGED AND MISSING A INSERT. FABRICATED NEW FLOOR PANEL 242XMF IAW EO B757-5320-9692-G.SDR IPXA11567311Cargo Track · wornINSPECTION TYPE:C4, MAIN CARGO FLOOR TRACK IS WORN AT FRONT OF TRACK SEGMENT AT BS 440, RBL 44 TO 48. FABRICATED NEW FLOOR TRACK IAW SRM 53-00-52-2R 5.SDR FDEA201105201936Skin · dentedPROTRUDING DENT, EXTERIOR SKIN BS 540, STR 17L. DENT OUT OF LIMITS IAW SRM 53-00-01 FIG 101. CUT OUT DAMAGED AREA IAW SRM 52-30-01 FIGURE 201 REPAIR 4. FABRICATED DOUBLER AND FILLER IAW SRM 52-30-01 FIGURE 201 REPAIR 4 AND INSTALLED IAW SRM 52-30-01 FIGURE SDR IPXA11567314Floor Panel · corrodedINSPECTION TYPE:C4, FLIGHT DECK FLOOR PANEL JUST LT AND AFT OF CONTROL STAND HAS CORROSION. FABRICATED AND INSTALLED NEW FLOOR PANEL 141N5810-481.SDR IPXA11567315Frame · dentedINSPECTION TYPE:C, CK AFT CARGO COMPARTMENT STA 1340 FRAME DENTED BETWEEN STR 23L AND 24L. REPAIRED AFT CARGO FRAME STA 1340 BETWEEN S-23L AND S-24L IAW SRM 53-00-07-2R-5 AND EA 110563.SDR IPXA1566630Floor Panel · dentedMAIN CARGO DECK FLOOR PANEL POSITION 5 RT SIDE HAS 3 SMALL DENTS. ID FLOOR PANEL AS PN 143N5457-90 AT BS 780-820 RT SIDE IAW EO B757-5320-969 2 FABRICATED A REPLACEMENT FLOOR PANEL.SDR NOCA04511Engine · bird ingestionSUSPECTED BIRD STRIKE DURING ROTATION, ODOR IN COCKPIT FOR APPROXIMATELY 2 MINUTES. ALL ENGINE INDICATIONS NORMAL. CABIN CREW DID NOT DETECT ODOR. ACCOMPLISHED INLET AND EXHAUST INSPECTION ACCOMPLISHED BOROSCOPE PER MM 72-00-00 AND TAP TEST OF FAN BLADES, PSDR IPXA1565868Compressor · stalledCOMPRESSOR STALL RT ENGINE AFTER T/O LEVEL AT 4000'. PERPFORMED ACCELERATION AND DECELERATION TEST NR 11. SYS TESTS NORMAL. REF MM 71-00-00-5.
Back to Rolls-Royce RB211-535E4 series