Elevate MRO, LLC
Service difficulty reports · 30
Reports filed under designator K5SR by a repair station, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE submitter_designator = 'K5SR' AND submitter_type_code = 'B' ORDER BY difficulty_date DESC, sdr_id DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE submitter_designator = 'K5SR' AND submitter_type_code = 'B' ORDER BY difficulty_date DESC, sdr_id DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR K5SR2021T30126Circuit Card · malfunctionedAGM #2 ADVANCED GRAPHIC MODULE FAILED DURING FLIGHT. AGM #2 ADVANCED GRAPHIC MODULE P/N 7036410-1902 S/N 10046276 WAS REMOVED. THIS CARD WAS REPLACED IN SEPT 2019 AT ACTT 1953.2. UNIT HAS 276.5 HOURS ON IT BEFORE FAILURE. ORDERED REPLACEMENT AGM #2 ADVANCEDSDR K5SR202008103599Controller · malfunctionedCUSTOMER SQUAWK OF NO HEAT IN CABIN AREA. INSTALLED MODIFIED VCSC CONTROLLER FROM ENVIRO SYSTEMS INC P/N 1300640-10 S/N 00216. OPERATION CHECKED SATISFACTORY. AIRCRAFT FLEW ABOUT 2 HOURS AND CUSTOMER SQUAWKED THAT THERE WAS NOW NO COCKPIT HEAT AND WINDSHIELDSDR K5SR2019091100000Module · malfunctionedAGM #2 ADVANCED GRAPHIC MODULE FAILED ON START UP. ORDERED REPLACEMENT AGM #2 ADVANCED GRAPHIC MODULE PART NUMBER 7036410-1902 UNIT WAS REPAIRED UNDER THEIR WORK ORDER 9342026 DATED 8/21/19. THE UNIT WE RECEIVED HAD A FAIL FOR CAS MESSAGE 2 SCREENS FAILED. AFTSDR K5SR2018041228697Actuator · inoperativeSTICK PUSHER INDICATION WONT CLEAR EVEN AFTER STICK PUSHER TEST. SHAKER WORKS BUT NO PUSHER WHEN DOING THE TEST WITH ENGINE RUNNING. INSTALLED NEW STICK SHAKER SERVO ACTUATOR. OPERATIONAL CHECKED SATISFACTORY.SDR K5SR201712218497Controller · inoperativeKMC 9200 FLIGHT CONTROLLER MINIMUMS KNOB WILL NOT SELECT BAROMETER, ONLY RA. INSTALLED A REPAIRED FLIGHT CONTROLLER VNAV. CHECKED SATISFACTORY.SDR K5SR2017122128497Display · failedDURING FLIGHT THE UPPER CENTER MULTIFUNCTIONAL DISPLAY KDU-1080 WENT PINK AND THEN BLACK. INSTALLED A REPAIRED CENTER MULTIFUNCTIONAL DISPLAY. OPS CHECKED SATSIFACTORY.SDR K5SR2017T28286Control Lever · bindingWHILE ON APPROACH PILOT HAD A LANDING GEAR CONTROL LEVER DISAGREE. GEAR CONTROL LEVER GOES UP HALFWAY IN RETRACTION CYCLE, BUT DOWN ALL THE WAY IN EXTENSION CYCLE. LANDING GEAR CONTROL SELECTOR LEVER ASSEMBLY WAS REMOVED AND A VISUAL INSPECTION OF THE LEVER ASDR K5SR20170117P2752Filter · collapsedCUSTOMER REPORTED THAT HIS TKS SYSTEM HAD LITTLE TO NO FLOW IN-FLIGHT AND ON GROUND. PERFORMED OPERATIONAL CHECK AND CONFIRMED DISCREPANCY. PERFORMED INSPECTION OF TKS FILTER AND FOUND THAT FILTER HAD COLLAPSED AND SWELLED, WHICH CAUSED THE TKS #1 AND #2 METESDR K5SR2016T27895Starter Gen · malfunctionedDURING NR 2 ENGINE START, THE STARTER GENERATOR AUTOMATIC CUTOUT FEATURE WHICH IS TO OCCUR AT 60 PERCENT N2 DID WORK. PILOT HAD TO MANUALLY DE-SELECT STARTER GENERATOR FROM OPERATING. REMOVED AND REPLACED THE STARTER GENERATOR. OPS CHECKED SATISFACTORY.SDR K5SR2016050927516Contactor · stuckPILOT REPORTED THAT THE UNDER FLOOR HEATER TRIPS THE CIRCUIT BREAKER AND WILL NOT RESET. PERFORMED TROUBLESHOOTING OF UNDER FLOOR HEATER SYS. FOUND UNDER FLOOR HEATER K665 CONTACTOR HAD STUCK IN ENERGIZED CLOSED POSITION CAUSING 28 VOLTS TO CONSTANTLY FEED HESDR K5SR2016T27503Socket · burnedWHILE PERFORMING AN AIRCRAFT SERVICE CHECK, FOUND EXTERIOR LOGO LIGHTS INOPERATIVE. PERFORMED TROUBLESHOOTING AND FOUND THAT THE P3 AND J3 PLUG AND CONNECTOR HAD SHORTED AT PIN DD AND MELTED THE PIN AND FEMALE PIN RECEPTACLE. CONNECTOR AND PLUG ARE LOCATED INSDR K5SR2016032227429Timer · failedALTERNATE DE-ICE TIMER FAILED DURING FUNCTIONAL TEST. ORDERED AND INSTALLED REPAIRED ALTERNATE PNEUMATIC TIMER, PN 3D2485-06, SN U1179 UNDER WO SAPO15-49894 DATED 10/15/15. PERFORMED FUNCTIONAL CHECK AND UNIT FAILED FUNCTIONAL CHECK. OUT OF BOX FAILURE, REMSDR K5SR2015112327126Brake Assy · crackedWHILE PERFORMING THE NR 1 AND NR 2 WHEEL AND TIRE CHANGE. UPON REMOVING THE WHEEL ASSEMBLIES FROM THE ACFT FOUND NR 1 AND NR 2 BRAKE ASSEMBLY CARBON ROTOR ASSEMBLIES TO BE CRACKED AND BROKEN OFF FROM THE KEY WAY GUIDES IN SEVERAL PLACES. R & R NR 1 AND NR 2 SDR K5SR201411181912Cable Assy · frayedWHILE PERFORMING A WALK AROUND INSPECTION OF THE AIRCRAFT PRIOR TO MAINTENANCE, WAS CHECKING THE MOVEMENT OF THE AILERONS AND HEARD A STRANGE GRINDING NOISE. UPON FURTHER INSPECTION FOUND NOISE COMING FROM THE LT AILERON AREA. GAINED ACCESS TO THE LT AILERONSDR K5SR201411181911Adapter · brokenPILOT EXPERIENCED LT ENGINE FAILURE IN-FLIGHT DUE TO AN OIL LEAK. AFTER LANDING, INVESTIGATED OIL LEAK AND FOUND THAT THE OIL FILTER ADAPTER ASSEMBLY HAD CRACKED AND BROKEN OFF BELOW THE OIL FILTER, CAUSING THE LOSS OF OIL. INSTALLED NEW OIL FILTER ADAPTER, PSDR K5SR2014092426219Elbow · crackedWHILE PERFORMING A SERVICE CHECK ON THE ACFT, NOTICED HYDRAULIC FLUID LEAKING FROM THE LT MLG WHEEL WELL. ON FURTHER INVESTIGATION, FOUND AUXILARY SYS SUCTION LINE LEAKING. REMOVED LINE ASSY AND FOUND 90 DEGREE ELBOW CRACKED. R & R SUCTION LINE AND 90 DEGRESDR K5SR201404042365Magneto · failedAT CRUISE POWER, ENGINE RAN ROUGH AND MISSED. RETURN TO DEPARTURE AND FOUND RT MAGNETO TO BE THE PROBLEM. MAGNETO WAS INSTALLED NEW IN THE ACFT ON 01/28/2014. TOTAL TIME ON MAGNETO WAS 26.0 HOURS UNTIL FAILURE. INSTALLED NEW MAGNETO, CHECKED SATISFACTORY.SDR K5SR2014012325725Line · chafedFOUND RT ENGINE HYD PUMP PRESSURE LINE FROM PUMP TO PYLON CHAFED THRU. CHAFING WAS CAUSED BY ADEL CLAMP SECURING LINE. THE RUBBER AROUND THE CLAMP HAD SLIPPED OFF, CAUSING THE CHAFING.SDR K5SR2013121825634Starter Gen · erraticRIGHT STARTER GENERATOR REQUIRED SEVERAL RESETS DURING LAST TRIP, ON FINAL LEG STARTER/GEN WOULD NOT COME ONLINE. MAINTENANCE PEFORMED VISUAL INSPECTION OF STARTER GENERATOR. FOUND STARTER GENERATOR BRUSHES WORN BEYOND SERVICEABLE LIMITS. STARTER GENRATOR HSDR K5SR2013093025526Annunciator · failedON ENGINE START UP, WHILE PERFORM PRE-TAXI CHECKS, CREW DISCOVERED THE "AC" FAIL LIGHT WAS ILLUMINATED ON THE ANNUNCIATOR PANEL AND WOULD NOT EXTINGUISH. MX PERFORMED TROUBLESHOTTING OF THE SYS AND FOUND THAT THE ANNUCIATOR PANEL WAS THE PROBLEM. THIS WAS THSDR K5SR2013041425122Cooling Fan · vibrationVAPOR CYCLE SYSTEM GROUND COOLING FAN DEVELOPED LOUD NOISE AND VIBRATION THAT WAS FELT AND HEARD IN CABIN. MX TROUBLESHOT AND FOUND THAT THE COOLING FAN ASSY HAD COME LOOSE INSIDE OF UNIT AND BANGED AROUND IN CASE. VAPOR CYCLE SYSTEM AND GROUND COOLING FAN INOSDR K5SR2013010824637Switch · brokenON AIRCRAFT DEPARTURE THE AIRCREW ATTEMPTED TO RETRACT THE FLAPS. FLAPS DID NOT REPSOND TO THE UP COMMAND. AIRCRAFT RETURNED TO THE AIRPORT, DURING THE APPROACH SELECTED THE FLAPS TO FULL FOR LANDING AND THE FLAPS WENT TO FULL DOWN. AFTER LANDING THE AIRCRESDR K5SR2012121124361Hydraulic Line · splitTROUBLESHOT HYDRAULIC LEAK ON RIGHT ENGINE. FOUND RIGHT HYDRAULIC PRESSURE HOSE FROM ENGINE DRIVEN PUMP TO BE LEAKING FROM PYLON AREA. REMOVED HOSE FOUND HOSE SPLIT. INSTALLED NEW HOSE P/N 624023-6-0246. LEAK AND OPERATIONAL CHECKED SATISFACTORY.SDR K5SR2012050323539Brake Assy · brokenATTEMPTED TO TAXI, ACFT WOULD NOT MOVE. FOUND THE LT BRAKE FROZEN. REMOVED LT MLG WHEEL AND TIRE ASSY AND FOUND LT BRAKE ASSY DISC HAD COME APART. LEFT BRAKE ASSY REMOVED. INSTALLED O/H BRAKE ASSY IAW AMM 32-42-01. BLEED, LEAK AND OPS CHECKED SATISFACTORYSDR K5SR2012050123537Wire · chafedWHILE PERFORMING ACFT SERVICE CHECK, NOTICED LARGE AMOUNT OF HYD FLUID AROUND APU COMPARTMENT. TROUBLESHOT WITH SYS PRESSURIZIED MOVED WIRE BUNDLE NEAR COMBINED HYD MANIFOLD AND WIRING SPARKED. FOUND 60HZ INVERTER WIRE HAD CHAFED THRU THE HYD PRESSURE LINE SDR K5SR2012050123536Shimmy Dampener · leakingAFT WAS LANDING WHEN A VIOLENT SHIMMY AND VIBRATION OCCURRED BETWEEN 40 TO 50 KTS, EMANATING FROM THE NOSE LANDING GEAR. THE AIRCRAFT WAS BROUGHT INTO MAINTENANCE. FOUND SHIMMY DAMPER LEAKING FLUID. NOSE LANDING GEAR SHIMMY DAMPENER, PN 5543001-11, S/N 684,SDR K5SR2012012823151Computer · malfunctionedACFT WAS ENROUTE WHEN AT FL200 WITH AN OAT OF -18, THE COMPUTER WAS PUSHER CAUTION LIGHT ILLUMINATED 5 TO 10 SECONDS AFTER THE INITIAL SEPARATOR AND PROP DE-ICE WAS TURNED ON DUE TO ICE. THE ACFT RETURNED TO DEPARTURE FOR REPAIRS. PERFORMED TROUBLESHOOTING OFSDR 99ZZZX2338Bulb · failedAL-1235-1097 BULB FAILED AFTER 85.9 HOURS OF SERVICE. BULB FAILED APPROXIMATELY 1 INCH FROM END THROUGH PIN HOLE MELTED IN GLASS. ESCAPING HOT GAS BURNED A HOLE OF APPROXIMATELY .75 INCH IN AIRCRAFT INTERIOR BEFORE STOPPING.SDR 96ZZZX5276Duct · crackedAIR CONDITIONING RAM AIR INTAKE TO REFRIGERATION UNIT INLET DUCT SEVERELY CRACKED ON LT AND RT SIDES LOWER AREA. RT SIDE LOWER CONNECTION PORT (CAPPED FOR THIS INSTALLATION) COMPLETELY SEPARATED FROM DUCT AND FOUND LAYING ON ELEVATOR FLIGHT CONTROL CABLES DURSDR 96ZZZX2030Downlock · low tensionLEFT MAIN TIRE WAS SKIDDED ON RUNWAY TO THE POINT OF TIRE FAILURE. LEFT MAIN GEAR THEN COLLAPSED. INVESTIGATION REVEALED LANDING GEAR DOWNLOCK TENSION WAS 15-20 POUNDS. BEECHCRAFT SM REQUIRES DOWNLOCK TENSION TO BE 45-65 POUNDS. IT IS SUPPOSED THE ADDITION
Back to Elevate MRO, LLC