- Certificate number
- NKVR853G
- Designator
- NKVR
- Name on the FAA list
- PRECISION SUPPORT SERVICES LLC
- Address
- 3800 NE THREE MILE LANE
MCMINNVILLE, OR 97128 - Phone
- (503) 687-0108
- Accountable manager
- BARROWS, GRAYSON
(503) 537-0108
grayson@flyprecision.com - Liaison
- BARROWS, GRAYSON
(503) 537-0108
grayson@flyprecision.com - On the FAA list
- On the list of October 26, 2026; listed since October 26, 2026 or earlier (OpenAirDocs’ first copy)
- Difficulty reports filed
- 5
From the FAA’s Find a Facility dashboard. The FAA writes names in capitals; the mixed case here is OpenAirDocs’ . The dashboard has no certificate dates, and nothing on it shows whether a certificate is in good standing: confirm with the station or its FAA office.
On this page
Ratings
What the FAA certificated the station to work on (14 CFR 145.59 and 145.61). A limited rating covers only the makes and models in the station’s operations specifications, which the FAA doesn’t publish.
| Rating | Class | What it covers |
|---|---|---|
| Airframe | Class 1 | Composite construction of small aircraft |
| Class 3 | All-metal construction of small aircraft | |
| Limited | Only the makes and models in its operations specifications | |
| Powerplant | Class 1 | Reciprocating engines of 400 horsepower or less |
| Limited | Only the makes and models in its operations specifications | |
| Radio | Limited | Only the makes and models in its operations specifications |
| Instrument | Limited | Only the makes and models in its operations specifications |
Service difficulty reports · 5
Reports the station filed (under its designator NKVR), newest first.
| 2015 | 4 |
|---|---|
| 2016 | 1 |
SDR NKVR2016030901Mount · crackedENGINE WAS REMOVED FOR O/H, THE ENGINE MOUNT WAS INSPECTED AND REJECTED DUE TO CRACKS.SDR NKVR20150908002Stiffener · crackedDURING INSPECTION, STIFFENER NEAR TAIL BOOM ATTACH INSPECTION PANEL FOUND TO BE CRACKED.SDR NKVR20150908001Stiffener · crackedDURING INSPECTION, STIFFENER FOUND TO BE CRACKED NEAR TAIL BOOM ATTACH INSPECTION PANEL.SDR NKVR20150817002Support · crackedDURING INSPECTION, RT LG TUNNEL SUPPORT FOUND TO BE CRACKED.SDR NKVR20150817001Support · crackedDURING INSPECTION, FOUND RT LG TUNNEL CRACKED, STATION 125, WL 21, RBL 13.5 & LBL 13.5, UPON FURTHER INSPECTION A CRACK IN THE SAME LOCATION WAS FOUND ON THE LT SIDE AS WELL. STOP DRILLED & FABRICATED REPAIR PARTS FROM NEW PART & INSTALLED IAW SRM 1 CHAPTER 5
STCs held under this name
STC holders whose name matches the station’s, matched by OpenAirDocs. A shared name can be another company.