20000822026329I

Incident

FAA incident report · Braero HAWKER1000 · Las Vegas, NV · August 22, 2000

Date
August 22, 2000 · 19:07 local
Place
Las Vegas, NV
Airport
Mc Carran International
Phase of flight
Normal Cruise
Operating rules
Air taxi and commuter (Part 135)
Aircraft
N546QS
Reported as
Braero HAWKER1000
Pilot’s flight hours
7,093 total2,503 in this make and model197 in the last 90 days

From the FAA’s Accident/Incident Data System (AIDS), through its Aviation Safety Information Portal, as reported. The NTSB investigates accidents separately, and its record of an accident is the fuller one. The aircraft is matched to the registry by N-number and event date, checked against the reported make and model; the registry’s history has gaps, so older matches can be wrong. Compare the reported make and model.

What happened

The FAA’s narrative, in sentence case. The FAA writes it in capitals and removes private details.

(-23) While cruising at FL370, "main hyd lo level" light came on. After 1-2 minutes, LH and RH "hyd lo press" came on. Within 5 minutes, hyd supply press gauge read zero. Maintenance action: found hydraulic transducer leaking at hydraulic module. Awaiting seal from exec jet aviation. Inspected aft equipment bay area, replaced failed seal, p/m 100-904-1109, on pressure transmitter at hydraulic module assembly, iaw 125-1000 mm ch 29-30-00. Bled and serviced main and auxiliary hydraulic reservoirs with 5606 iaw 125-1000 MM12-10-20, performed gear retraction test iaw 125-1000 MM32-30-00, with no defects noted. Ran engines and leak checked ok, closed and secured access. Operator submitted mrr. Closed.

As the FAA filed it

(-23) WHILE CRUISING AT FL370, "MAIN HYD LO LEVEL" LIGHT CAME ON. AFTER 1-2 MINUTES, LH AND RH "HYD LO PRESS" CAME ON. WITHIN 5 MINUTES, HYD SUPPLY PRESS GAUGE READ ZERO. MAINTENANCE ACTION: FOUND HYDRAULIC TRANSDUCER LEAKING AT HYDRAULIC MODULE. AWAITING SEAL FROM EXEC JET AVIATION. INSPECTED AFT EQUIPMENT BAY AREA, REPLACED FAILED SEAL, P/M 100-904-1109, ON PRESSURE TRANSMITTER AT HYDRAULIC MODULE ASSEMBLY, IAW 125-1000 MM CH 29-30-00. BLED AND SERVICED MAIN AND AUXILIARY HYDRAULIC RESERVOIRS WITH 5606 IAW 125-1000 MM12-10-20, PERFORMED GEAR RETRACTION TEST IAW 125-1000 MM32-30-00, WITH NO DEFECTS NOTED. RAN ENGINES AND LEAK CHECKED OK, CLOSED AND SECURED ACCESS. OPERATOR SUBMITTED MRR. CLOSED.