JASC 2150
Service difficulty reports · 12,389
Reports filed under 2150 · Cabin Cooling System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2023012336903A/C Pack · odorFUME EVENT DURING DECENT PACK 1-PERFORMED MX TASK IAW AMM 05-50-00. PERFORMED OPS TEST OF PACK 1. FOUND NO EVIDENCE OF FUME EVENT THOUGH CABIN OR COKPIT. OPS TEST GOOD NO DEFECTS NOTEDSDR GTIA2023012336902A/C Pack · odorSTRONG ODOR OF SOCKS/ROTTEN EGGS DURING DECENT AROUND 10,000FT.-PREFORMED TSM 05-50-810-831 TO ISOLAT FUME EVENT. ISOLATED TO PACK ONE. DEFER PACK 1 ON LP 3059568-2SDR ASAA2023012141638Warning Light · false activationR PACK LIGHT ILLUMINATES WITH RECALL CHECK. GROUNDED - YES. PERFORMED PACK/ZONE TEMP. CONTROLLER BITE TEST REF. B737-800 AMM 21-61-00-700-806-002. BITE TEST GOOD. NO HISTORY FOR 30 DAYS. ORIG SUB DATE: 1/25/2023SDR ASAA2023012141636Modulating Valve · faultedL PACK LIGHT ILLUMINATES ON RECALL AND EXTINGUISHES ON RESET. GROUNDED - YES. REMOVED AND REPLACED LEFT PACK TEMP CTL VALVE PER B737-900 AMM 21-51-10. ORIG SUB DATE: 1/25/2023SDR NACA2023012000003Control Valve · failedNO EICAS MESSAGE OR PACK OFF LIGHT FOR RIGHT PACK. REMOVED AND REPLACED FLOW CONTROL VALVE IAW AMM 21-51-01 OPS CHECKED GOOD NO DEFECTS NOTED. NO TIME INFO FOR PART IN TRAX.SDR ASAA2023012301583Modulating Valve · faultedZONE TEMP CONT CAB INOP. GROUNDED - YES. PERFORMED PACK /ZONE TEMPERATURE CONTROLLER BITE TEST REF B737-900 AMM 21-61-00. PACK CONTROLLER 2 FLAGGED FLIGHT DECK TRIM VALVE ON "BIT" AND " PREV FLT" VERIFY ON BOTH BOXES SHOW GREEN. PER B737-900 FIM 21-62 TASK 832SDR ASAA2023012301582Actuator · degradedLEFT "PACK" LIGHT ILLUMINATED ON PRESURIZATION PANEL PASSING FL180 DURING CLIMB. LIGHT EXTINGUSHED AFTER RUNNING QRH PROCEDURE WITH TRIP RESET APPROX 2 MIN LATER LEFT "PACK" LIGHT CAME ON AGAIN AND PACK WAS SHUT OFF PER QRH PROCEDURE - LIGHT REMAINED ILLUMIUATSDR F3LA2023230100014A/C Pack · odorDURING CRUISE. TURNED UP COCKPIT HEAT, IMMEDIATELY GOT AN ODOR OF HOT DUCTING IN COCKPIT. TURNED HOT DOWN &ODOR SEEMED TO DISSIPATE. PERFORMED ELIMINATION OF ODOR IN FLT DECK/CABIN. PACK 1 SUSPECTED. TURNED OFF PACK 1 IAW QRL, NO ODOR DETECTED. LT PACK OFF FOSDR GTIA2023012336899A/C Pack · odorFUME/ODOR EVENT ON PACK 1 IN DESCENT DIRTY SOCKS SMELL PROCDURE COMPLIED WITH AND ODOR WENT AWAY WITH PACK 1 OFF-PERFORMED TSM PROCEDURES IN TSM 05-50-00-810-031A FOUND ODER TO BE PACK 1 SYS PACK 2 SYS OPS CHECK NORMAL NO ODER / DEFECT NOTED REF LOG PAGE 29467SDR GTIA2023012336898A/C Pack · odor"FUME / AIR QUALITY / OVER EVENT APROACH. FLIGHT ATTENDENTS DESCRIBED BUENT RUBBER/ ELECTRICAL SMOKE ODOR. ODOR IN THE COCKPIT WAS MUSTY GYM SOCKS AND BURNT RUBBER, BUT NO TOO STRONG -ACCOMPLISHED TSM 05-50-00-810-831. FOR CABIN ODOR FOUND PACK 1 TO BE SOURCESDR GTIA2023011936896A/C Pack · odorDIRTY SOCKS ODOR ON DECENT FUME REMOVALC CHECKLIST AVAILABLE ISOLATED TO PACK 1 ( PACKS A319 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - AT OR BELOW FL 370 )SDR ASAA2023011971558Control Valve · faultedLEFT ECS PACK ANALOG DISCRETE TO FMC DOES NOT INDICATE "OFF" WITH LEFT PACK SWITCH PLACED TO OFF. GROUNDED - YES. REMOVED AND REPLACED LH PACK CONTROL VALVE REF AMM 21-51-01-400-805-002.SDR GTIA2023011636891A/C Pack · odorFUME EVENT WHILE IN CRUISE FLIGHT LEAD FA CALLED TO REPORT A DIRTY DIAPER ODOR IN THE BACK OF THE PLANE PERFORMED THE QRM PROCEDURE FOUND WHEN PACK 2 OFF SMELL WENT AWAY. LATER IN CRUISE FA SAID THE FOUL ODOR RETURNED WE PERFORMEWD AIR PACK 1 +2 FAULT PROCEDUSDR ASAA2023011951559Modulating Valve · faultedRIGHT PACK LIGHT ILLUMINATED IN TAXI. EXTINGUISHES WITH MASTER RESET. GROUNDED - YES. REMOVED & REPLACED R. PACK TEMP CONTROL VALVE, REF B737-900 AMM 21-51-10.SDR ABXA2023011609Acm · inoperativeLEFT AIR CONDITIONING PACK INOP. AIRCRAFT BACK TO BLOCK AND GROUNDED BY MAINTENANCE. MAINTENANCE DEFERRED LEFT AIR CONDITONING PACK IAW MEL 21-51-1-1. AIRCRAFT RETURNED TO SERVICE.SDR ASAA2023011741540Modulating Valve · faultedR PACK LIGHT - RESETS. GROUNDED - YES. FOUND FAULT THIS PACK TCV (V141). REMOVED AND REPLACED RIGHT TCV IAW B737-800 AMM 21-51-10.SDR ASAA2023011441537Modulating Valve · faulted"CONT CABIN" ZONE TEMP LIGHT ILLUMINATES ON RECALL IT EXTINGUISHES WITH MASTER CAUTION RESET. GROUNDED - YES. REMOVED AND REPLACED TEMPERATURE CONTROL VALVE IN REF TO B737-800 AMM 21-51-10.SDR GTIA2023011636886A/C Pack · odorFUME EVENT DESENDING THROUGH 4500. SMELL DISSIPATED WHEN PACK 1 SELECTED OFF ( PACKS A320 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED )--SDR GTIA2023011636885A/C Pack · odorMUSTY SOCK SMELL ON T/O GOES AWAY AT THRUST REDUCTION RETURNS IN DECENT ISOLATED TO PACK 1-PERFORMED TSM 05-50-00-810-831-A AND VERIFIED ODOR COMING FROM PACK 1 REF LP 2905468-1 FOR FURTHER ACTIONSDR GTIA2023011636884A/C Pack · odorFUME EVENT DESCENDING THROUGH 4000FT TURNED PACK 1 OFF AND SMELL DISSIPATED ( PACKS A320 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED )-REACTIVATED PACK #1 ISDR SWIA202301167116A/C Pack · smokeTROUBLESHOOT PACK 1 AUTO FAIL. STATES COCK PIT SMELLS LIKE OIL BADLY AND SMOKEY MIST IN THE AIR FOR ABOUT 20 SECONDS THROUGHOUT THE COCKPIT AND CABIN. (FILED CLOSED)TROUBLESHOT PACK 1 AUTO FAIL, PILOT STATED COCKPIT SMELLS LIKE OIL AND SMOKEY MIST IN THE AIR. SDR CALA2023011300109Control Valve · inoperativeTECH SUPPORT...DUE TO CHRONIC RIGHT PACK TRIP ON T/O ROLL, REF FIM 21-53 T/820.WOULD START BY CHECKING THE BYPASS CHECK VLV. ASSY FOR OPS AND MAKE SURE ITS INSTALLED AS THIS WILL CAUSE TRIP ON T/O ROLL IF MISSING OR BAD. CARRIED BY ELB REF AMM 21-51-11-400 OPSSDR SWAA2023011329584Acm · defectiveAT CRUISE F/A HEARD A BANG NOISE MID CABIN. COCKPIT AND CABIN THEN SMELLED FAINT SMELL OF SMOKE. RUN QRH; SMELL IMMEDIATELY CLEARED OUT.<[01] PERFORMED CONDITIONAL INSPECTION FOR SMOKE IN CABIN PER AMM 05-51-56. DETERMINED CAUSE OF SMOKE & ODOR TO BE A DEFECTISDR GTIA2023011236876A/C Pack · odorFUME EVENT DURING FINAL APPROACH. VERY STRONG DIRTY SOCK ODOR IN COCKPIT & CABIN. (FRONT AND REAR) SEEMED PREDOMINATLY FROM PACK 1-PREFORMED TSM 05-50-00-810-831-A ISOLATED TO PACK 1 PER TSM. PACK 1 DEFREED ON LOG PAGE 2982218-1SDR ASAA2023011341497Modulating Valve · faultedLEFT PACK LIGHT ILLUMINATED ON RECALL EXTINGUISHED WITH MASTER CAUTION RESET. GROUNDED - YES. REPLACED TRIM CONTROL VALVE PER B737-900 AMM 21-51-10.SDR DALA2023011100209Acm · seizedSHIP 3131 - AIR PACK 1 OVHT DISPLAYED ON ECAM TEMERATURE WAS UNCONTROLLABLE MAX OUTLET COCKPIT TEMP WAS 134. THERE WAS A PLASTIC ODOR. CORRECTIVE ACTION: REPLACED ACM 10HM1 PER A319 AMM 21-52-21 LEAK & OPS TEST OK. (9397947)SDR 6CBA2023011323013Evaporator · faultedDURING FLIGHT FROM KBOS TO KAVL, THE FLIGHT CREW REPORTED LOUD GRINDING SOUND AND BURNING SMELL FROM COCKPIT OUTLETS. THE FLIGHT CREW DIVERTED TO KTEB, DID NOT DECLARE AN EMERGENCY, AND LANDED WITHOUT INCIDENT. REMOVED COCKPIT EVAPORATOR IAW PAMM PC24-A-E21-SDR QMLA2023010920002Compressor · failedDURING MAINTENANCE CHECK FLIGHT FOR SPACER TUBE REPLACEMENT (MAST REMOVAL/INSTALL, FLIGHT CONTROLS DISCONNECTED), THE PILOT AND I HEARD A SOFT THUD FOLLOWED BY A 3-5 SECOND HISSING NOISE. THIS OCCURRED NOT LONG AFTER TAKEOFF, WHILE CLIMBING APPROX. 2 MILES FROSDR DALA2023010600091A/C Pack · contaminatedSTRONG SMELL OF DE ICE FLUID. C/W ODI PREVENTION AMDS CARD 0550-2002.SDR YENA2023010600016A/C Pack · odorFLT#492, LAX-BUF. 'ON CLIMB OUT STRONG OIL FUMES IN COCKPIT FWD AND AFT GALLEYS ABATED AFTER 10 MIN. FOLLOWED THE ISOLATION GUIDE FUMES STRONGLY RETURNED IN THE TOP OF DESCENT SURVEY COMPLETED. T/S FOUND SOURCE OF SMELL TO BE NR 2 PACK, PERFORMED HIGH POWER SDR ASAA2023010341403A/C Pack · faultedL PACK LIGHT ULLUMINATED AT LEVEL FLIGHT. FL350. ACCOMPLISHED QRH PROCEDURE, PACK LIGHT REMAINED ILLUMINATED. GROUNDED - YES. FOUND MX MESSAGE 21.55100-21-55030. RESET PER B737-9 FIM 21-51-00-810-807. MESSAGE CLEARED AND LH PACK REMAINS EXTINGUISHED.SDR ASAA2023010921436Acm · seizedAT GATE AFTER TURNING ON RIGHT PACK PASSENGERS REPORTED BURNING SMELL. SIMULTANEOUSLY THE RIGHT "PACK" LIGHT ILLUMINATED. GROUNDED - YES. FOUND RIGHT HAND ACM SEIZED. REMOVED AND REPLACED R/H PACK AIR CYCLE MACHINE, OPS AND LEAK CHECK GOOD. NO MAINT LIGHT OR PSDR ASAA2023010241378Acm · faultedRIGHT PACK TEMPERATURE RAPIDLY CLIMBED TO 90 DEGREES WHEN TURNED ON. KEPT FROM OVER TEMP BY TURNING OFF. GROUNDED - YES. REMOVED AND REPLACED RH ACM IN REF TO B737-900 AMM 21-51-04-/401. PERFORMED ACM INSTALL TEST REF AMM 21-51-04-860-025-002 LEAK CHECK GOOD. SDR ASAA2023010241321Modulating Valve · faultedRT PACK LIGHT ILLUMINATED. RT PACK TEMP IS HIGH. GROUNDED - YES. FOUND R/H PACK TEMP INOP. REPLACED PACK TEMP BULB T489, AND TEMP CONTROL VALVE. ALL OPS NML. GROUND VERIFICATON SATISFACTORY. REF AMM 21-51-60 & 21-51-10.SDR YENA2023010300001Filter · failedFLT#2752, SJU-TPA. 'LEVEL 1 ODOR FROM #1 PACK DURING DESCENT STRONG ODOR FROM COCKPIT TO MID-CABIN TURNED OFF #1 PACK AND ODOR DISSIPATED TURNED BACK ON AFTER 5 MINS AND ODOR RETURNED TURNED OFF AGAIN AN ODOR STOPPED; C/W INFO NOTICE 2017-T015 J CONFIRMED MX-2SDR YENA2023010301303A/C Pack · odorFLT 2752, SJU-TPA. LEVEL 1 ODOR FROM NR 1 PACK, DURING DESCENT STRONG ODOR FROM COCKPIT TO MID-CABIN TURNED OFF NR 1 PACK AND ODOR DISSIPATED. TURNED BACK ON AFTER 5 MINS AND ODOR RETURNED, TURNED OFF AGAIN AN ODOR STOPPED. C/W INFO NOTICE 2017-T015 J CONFISDR ASAA2023010141325Warning Message · false activationLEFT PACK ILLUMINATED AT CRUISE. RAN QRH DID NOT EXTINGUISH. GROUNDED - YES. ACCOMPLISHED B737-9 IFIM 21-51-00-810-807 FOR LATCHED FAULT 21-55030. FAULT RESET, LATCHED MSG NO LONGER DISPLAYED. LEFT PACK LIGHT EXTINGUISHED.SDR ASAA2022123141368Bulb · faultyAFTER 4 HOURS IN CRUISE R PACK TEMP INDICATES LOW. NO ISSUES CONTROLLING CABIN TEMP NOTED. AT FL400, L PACK 32, R PACK 2, PAX CABIN 26. GROUNDED - YES. REPLACED RH PACK TEMP BULB PER B737-900 AMM 21-51-60. OPS CHECK GOOD.SDR ASAA2022123141323Modulating Valve · faultedLEFT PACK LIGHT ILLUMINATED ON MC RECALL. "PACK" LIGHT EXTINGUISHED WHEN SYSTEM RESET. GROUNDED - YES. ACCOMPLISHED B737-800 FIM 21-62 TASK 801, FOUND R TCV FAULT. REMOVED AND INSTALLED NEW RIGHT TCV PER AMM 21-51-10/401, OPS NORMAL. GROUND VERIFICATION SUCCESSDR ASAA2022123041326Warning Light · false activation#2 PACK LIGHT ILLUMINATES ON MASTER CAUTION RECALL. PACK LIGHT EXTINGUISHES UPON MASTER CAUTION RESET. GROUNDED - YES. ACCOMPLISHED PACK ZONE TEMP CONTROL BITE PER B737-900 FIM 21-62 TASK 801. LOGGED EXIT, FAULT CLEARED.SDR I5PA2022123075705Reheater · faultedFLT NO. MGE300. ESI - RIGHT PACK TEMP INOP LIGHT (MEL 21-61-03). REMOVED AND REPLACED RIGHT PACK REHEATER IAW AMM 21-51-07. RIGHT PACK NORMAL.SDR F3LA2023030100002Acm · contaminatedAIR RETURN, STRONG BURNING SMELL STARTED IN REAR OF ACT DURING CLIMBOUT APPOX 1000FT MCT POWER SETTING. ODOR QUICKLY CONTINUING TO MOVE FORWARD TO FRONT CABIN THEN FLIGHT DECK. CLEANED OIL CONTAMINATION IN LT A/C BAY, REMOVED AND REPLACED PRIMARY MAIN HEAT SDR ASAA2022123001306Warning Message · false activationLEFT PACK LIGHT ILLUMINATES DURING RECALL AND RESETS WHEN MASTER CAUTION PUSHED. FOLLOWED ASA QRH AND BOTH PACK LIGHTS ARE EXTINGUISHED. GROUNDED - YES. #1 PACK TEMP CONTROL BITE LOGGED RAM AIR DOOR ACT, FAULT RESETS. ACCOMPLISHED BITE TEST FOUR MORE TIMES, NOSDR JJBA20221230030A/C Pack · odorBAD ODOR COMING FROM PACKS. PERFORMED DECONTAMINATION OF AIR CONDITIONING SYSTEM. NO FURTHER ODORS NOTED.SDR GTIA2022122936860A/C Pack · contaminatedDIRTY SOCK SMELL ON FINAL DES 12000 FT, PACK 1 OFF. RESOLVE THE PROBLEM IDLE POWER, PERFORMED INSPECTION OF APU COMP IAW AMM 49-13-00. NO DEFECTS FOUND. PERFORMED OPS CK OF BOTH PACKS IAW AMM 21-61-00. PACK NR 1 FOUND TO BE COMTAMINATED.SDR ASAA2022122841322Modulating Valve · failedRIGHT PACK LIGHT ILLUMINATED, RESET ON MASTER CAUTION RESET. GROUNDED - YES. CONFIRMED FAULT, R/H PACK LIGHT ILLUMINATES WHEN RECALLED. NO.2 PACK/ZONE TEMP CONTROLLER SHOWS HARD FAIL "TCV-2". REMOVED & REPLACED TCV-2 (V141) REF B737-800 AMM 21-51-10.SDR ASAA2022122541278Actuator · faultedLEFT PACK INOP DESCENT RECALL CHECKLIST. GROUNDED - YES. REPEAT DISCREPANCY OF LEFT RAM AIR ACTUATOR FAULT LOGGED BUT RESETS DURING PZTC BITE. OBSERVED ACTUATOR DURING BITE AND NOTICED NO GLARING ABNOMALIES. REMOVED & REPLACED LEFT RAM AIR ACTUATOR PER B737-80SDR ASAA2022122751227Warning Light · false activationAFTER START LEFT PACK LIGHT ILLUMINATED. GROUNDED - YES. PERFORMED B737-800 FIM 21-53 TASK 821, PERFORMED BITE CHECK PER FIM 21-62TASK 801 FOUND IN RAM AIR ACT FAULT IN PREVIOUS FLIGHT BUT CLEARS IN BIT CHECK, THIS IS AN INTERMITTIEN FAULT.SDR GTIA2022122736855A/C Pack · odorFUME EVENT PACK 1 STRONG SMELL -PER TSM 05-50-00-810-831-A. FOUND PACK 1 HAS FUME EVENT. PACK 2 IS CLEAR WITH APU & ENG RUN IAW AMM 71-00-00 & 49-00-00.SDR CALA2022122303479Heat Exchanger · leakingRIGHT PACK PRIMARY HEAT EXCHANGER HAS LARGE LEAK UPPER FORWARD LNBD CORNER. FOUND SECONDARY HEAT EXCHANGER CRACKED AT FWD UPPER INBD CORNER. REMOVED PRIMARY AND SECONDARY HEAT EXCHANGER AND DIFFUSER ASSY. REF AMM 21-51-03-000-805-002. REPLACED SECONDARY HEA
Back to JASC 2150