JASC 2160
Service difficulty reports · 3,040
Reports filed under 2160 · Cabin Temperature Control System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2020020392049Warning Light · false activationCLIMBING OUT OF SFO PASSING 10000 FEET "AIR COND MASTER CAUTION AND CONT CAB, ZONE TEMP. RAN QRH ZONE TEMP PROCEDURE EXTINGUISH. SUPPLY DUCT TEMPERATURE NOPRMAL. PER NOTE QRH- " NO FUTHER ACTION REQUIRED. CONTINUE TO OGG. GROUNDED - YES. PERFORMED PACK/ZONE TESDR ASAA202002032030Controller · malfunctionedAT TOP OF DESCENT CONT CAB TEMP CONTROLLER ZONE TEMP ILLUMINATED ON RECALL. GROUNDED - YES. ACCOMPLISHED OPS TEST B737-800 AMM TASK 21-61-00-700-807-002 FOR CABIN TEMP CONTROL AND INDICATION, OPS TEST GOOD NO FAULTS FOUND.SDR ASAA2020013192031Valve · faultedON RECALL CONT CAB ZONE TEMP LIGHT ILLUMINATED, GOES OUT WHEN RESET. GROUNDED - YES. PERFORMED ZONE TEMP CONT BITE IAW FIM 21-62, TASK 801. FOUND NR 2 CONTROL FAULT, CONTROL CABIN TRIM VALVE. REMOVED AND REPLACED V143 TRIM VALVE IAW AMM 21-61-211. OPS CSDR ASAA2020013082018Warning Light · false activationON PUSHBACK, CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED, EXTINGUISHED WITH MASTER CAUTION RESET. GROUNDED - YES. REL PER MEL 21-21G FLIGHT DECK ZONE PRIMARY TEMP CONT INOP. ENROUTE MEL - #2 ZONE TEMP CONT LOGGED TRIM AIR VALVE FAULT FLT DECK. FAULT CLEARED &SDR AALA202001289031Sensor · faultyAIRCRAFT WAS GROUNDED: CABIN AIR TEMP EXCESSIVE COLD ACCOMPLISHED QRH STEP 1-6 TEMP FIN ALLY START TO RISE. WENT TO STEP 24. CONTINUE FLT WITH MX AND DX CONCURANCE WITH BOTH CONTROLLERS IN STBY. APPROX 2HRS LATER CAB IN TEMP UNABLE TO CONTROL EXCESSIVE COLD. QSDR DXTA2020012703390Shutoff Valve · malfunctionedWITH THE BLEEDS ON, A BURNING ODOR CAN BE SMELLED IN THE COCKPIT AT LOWER ALTITUDES. ECS SYSTEM IN AUTO & MANUAL TEMP SELECTED TO BELOW 20C, COCKPIT DUCT TEMP SHOWED 43C. CABIN SET AT SAME SETTING DUCT TEMP SHOWED 16C. COCKPIT DUCT CONSISTENTLY INDICATES HOSDR ASAA2020012861984Warning Light · false activationDURING RECALL, CONT CAB ZONE TEMP CAUTION LIGHT ILLUMINATED. EXTINGUISHED ON RESET. GROUNDED - YES. ACCOMPLISHED LEFT AND RT PACK FLOW TEMPERATURE CONTROLLER BITE TEST IAW AMM 21-61-00-740-801-002. NO ACTIVE FAULTS LOGGED. ACCOMPLISHED FLT DECK FILTER CLEANISDR ASAA2020012743959Warning Light · false activationCONT CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL AND RESETS. GROUNDED - YES. PERFORMED PACK TEMP CONTROL BITE PROCEDURE IAW FIM 21-62, TASK 801. RESET PACK TEMP CONTROLLER AND RAN PACKS, CONT CABIN ZONE TEMP LIGHT REMAINS EXTINGUISHED ON RECALL.SDR ASAA2020012733958Warning Light · false activationFLT DECK PRIMARY TEMP (ZONE TEMP) LIGHT ILLUMINATED ON MASTER RECALL. RAN QRH ZONE TEMP 2.22 LIGHT EXTINGUISHED WHEN PUSHING MASTER CAUTION RESET. GROUNDED - YES. RAN AMM 21-61-00, PACK ZONE BITE AND NO STORED FAULTS RAN PACKS IAW 21-00-00 AND NO FAULTS FOUNDSDR ASAA2020012213933Warning Light · false activationAFTER START CONT CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL AND EXTINGUISHED ON MASTER CAUTION RESET. GROUNDED - YES. PERFORMED A BITE CHECK ON THE NR 2 CONTROLLER. FAULT, FLT DECK TRIM VALVE RESET, BITE CHECKED GOOD.SDR ASAA2020012201934Warning Light · false activationAFTER START CONT CAB LIGHT ILLUMINATED DURING RECALL. THE CONT CAB LIGHT EXTINGUISHES DURING MASTER CAUTION RESET. GROUNDED - YES. PERFORMED A TEMP CONTROLLER BITE CHECK IAW FIM 21-60 TASK 801, NO FAULTS LOGGED.SDR ASAA2020012201927Warning Message · false activationCONT CAB ZONE TEMP. EXTINGUISHES UPON RECALL. GROUNDED - YES. NR 2 ZTC LOGGED FLT DECK TRIM VALVE. BITE TESTED GOOD. FAULT RESET.SDR ASAA2020012203926Warning Message · false activationCONT CABIN ZONE TEMP LIGHT ILLUMINATES ON MASTER RECALL. EXTINGUISHES WHEN RESET. GROUNDED - YES. ACCOMPLISHED FIM 21-62 TASK 801. RT PZTC SHOWED FLT DECK TRIM VALVE FAULT. RESET CONTROLLER.SDR ASAA2020012181901Sensor · dirtyCONT CABIN ZONE TEMP LIGHT ILLUMINATED. GROUNDED - YES. UNABLE TO DUPLICATE DEFECT. BITE OF PACK/ZONE TEMP CONTROLLERS PER B737-900 FIM 21-62 TASK 801 SHOWED NO FAULTS. CLEANED CONTROL CABIN TEMP SENSOR AND FILTER AND PERFORMED CABIN TEMP CONTROL AND INDICATIOSDR ASAA2020012181893Warning Light · false activationON RECALL CONT CAB ZONE TEMP ILLUMINATES & GOES OUT ON MASTER CONTROL RESET. GROUNDED - YES. T/S SYSTEM AMM 21-61-00-700-806-002, AND AMM TASK 21-61-00-700-807-002. OPS CHECKED GOOD.SDR ASAA2020012171897Warning Light · false activationCONT CAB ZONE TEMP LIGHT ILLUMINATED ON RECALL AND WAS RESETTABLE. GROUNDED - YES. INITIAL EVALUATION, HAD ZONE TEMP LIGHT ILLUMINATED ON RECALL. PERFORMED PACK TEMP CONTROL BITE PROCEDURE FOLLOWING B737-900 FIM 21-62 TASK 842. PREVIOUS FLT HAD FLT DECK TRIM VSDR ASAA2020011631867Warning System · false activationDURING THE AFTER START CHECKLIST AFTER PUSHING RECALL. THE ZONE TEMP LIGHT ON THE CONT CAB ILLUMINATED. THE QRH WAS ACCOMPLISHED AND THE ZONE TEMP LIGHT EXTINGUISHED UPON PUSHING THE MASTER CAUTION LIGHT. GROUNDED - YES. ACCOMPLISHED FIM 21-62 TASK 801. LT PZTSDR ASAA2020011531863Warning System · false activationCAB ZONE TEMP LIGHT ILLUMINATES ON RECALL GOES OUT ON RESET. GROUNDED - YES. CK OF PACK TEMP CONTROLLER FOUND LATCHED FAULT ON NR 2 PACK TEMP CONTROLLER FLT DECK TRIM VALVE. SUBSEQUENT BITE TEST PASSED - OPS CK OF PACK SYS & TRIM AIR NML. LITE EXTINGUISHED. OPSDR ASAA2020011331828Warning System · false activationUPON RECALL "ZONE TEMP" FOR THE FWD CAB LIGHT ILLUM. RESET WITH MASTER CAUTION RESET BUTTON. GROUNDED - YES. RESET PACK CONTROL TEMP IAW FIM 21-62-801 CONTROL SEQIT FAULT CAB TEMP FAULT NO LONGER PRESENT.SDR ASAA2020011331827Control Valve · failedAFTER START, FLT DECK CONT CAB ZONE LIGHT ILLUMINATED. GROUNDED - YES. RT PACK ZONE TEMP CONTROLLER SHOWS FLIGHT DECK TCV (V143) FAIL. REMOVED & REPLACED TCV REF AMM 21-61-21, LK CK & OPS CK NML. ACCOMPLISHED RT PACK ZONE TEMP CONTROLLER BITE TEST REF AMM 21-6SDR UIEA2020010700025Warning System · false activationAFT CABIN TEMP EICAS CAUTION MSG IN FLIGHT.(<P>PERFORMED BITE CHECK ON THE ZONE TEMP CONTROL UNIT. NO CURRENT FAULT, NO MESSAGES PRESENT. REF AMM 21-61-00.</P>)SDR ASAA2020010731769Warning System · false activationCONT CAB ZONE TEMP LIGHT ILLUMINATED ON DESCENT OUT OF FL25000. GROUNDED - YES. REF B737-800 FIM TASK 21-62 TASK 842, BOTH PZTC BITE TESTS GOOD. VERIFIED PACKS OPS CHECKED NORMAL ON GND W/O FAULTS. REMOVED MEL 21-21G, C/N 05042592.SDR UIEA2020010640017Modulating Valve · malfunctionedAFT CABIN TEMP EICAS MESSAGE ON THE GROUND. REMOVED AND REPLACED AFT TRIM MODULATING VALVE IAW AMM 21-61-02-004-006, AND 21-61-02-404-041. OPS CHECKED GOOD.SDR UIEA2020010700034Relay · failedEICAS MSG: AFT CABIN TEMP.(<P><SPAN>REMOVED AND REPLACED AFT TRIM AIR VALVE RELAY IAW SWPM 20-81-00. PREVIOUSLY AFT TRIM AIR VALVE WAS REPLACED PER FIM 21-60-FT 804. REPLACE K240 RELAY IF PROBLEM CONTINUES. OPS CHECK NORMAL IAW AMM 21-61-00.</SPAN><BR /></P>)SDR UIEA2020010200004Modulating Valve · faultyEICAS MSG AFT CABIN TEMP(<P>PERFORMED ZONE TEMP CONTROLLER BITE IAW FIM 21-60 F/T 804. FOUND AFT ZONE TRIM MODULATING VALVE FAULT. REMOVED AND REPLACED AFT ZONE TRIM MODULATING VALVE IAW AMM 21-61-07. OPS CHECK GOOD. NO DEFECTS NOTED.<BR /></P>)SDR ASAA2020010331743Control Valve · intermittentRIGHT PACK LIGHT ILLUMINATES DURING RECALL AND EXTINGUISHES WHEN PRESSING MASTER CAUTION RESET. GROUNDED - YES. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE TEST. FOUND FAULT TCV#2. REMOVED AND REPLACED #2 TEMP CONTROL VALVE REF B737-900 AMM 21-51-10. BITE TESTSDR ASAA2019123071717Warning Message · false activationHAD ZONE TEMP ON RECALL ENROUTE RAN QRH AND IT WENT OUT. GROUNDED - YES. PERFORMED PACK TEMP CONTROL BITE PROCEDURE PER B737-900 FIM 21-62 TASK 801. HAD FAULT FLT DECK TRIM VALVE ON PREVIOUS FLIGHT. PERFORMED FIM 21-62 TASK 832 AND DURING INITIAL EVALUATION FASDR ASAA2019123051699Warning Message · false activationCONT CAB ZONE TEMP LIGHT ON RECALL EXTINGUISHES ON MASTER CAUTION RESET. GROUNDED - YES. PERFORMED BITE PER B737-800 AMM TASK 21-62-00 SHOWS FLIGHT DECK TRIM VALVE ON CONTROLLER. CONT CAB ZONE TEMP/PRIMARY INOP. AIRCRAFT CHECKED AND RELEASED PER MEL 21-21G. (RSDR ASAA2019122633702Warning Light · false activationCONT CAB ZONE TEMP LIGHT ILLUMINATES WITH MASTER CAUTION RECALL. CAUTION LIGHT EXTINGUISHES WITH MASTER CAUTION RESET. GROUNDED - YES. FOUND FAULT ON ZONE TEMP CONT #2,TRIM VALVE FLT DECK. PERFORMED BITE TEST PER B737-900 AMM 21-61-002, FAULT CLEARED, OPS CHK SDR ASAA2019122423688Sensor · dirtyCONT CAB ZONE TEMP LIGHT MASTER CAUTION RECALL LIGHT EXTINGUISHED WHEN RESET. GROUNDED - YES. CLEANED CAB ZONE FILTER AND RECHECKED MASTER CAUTION RECALL, NO CAB ZONE TEMP LIGHT NOTED. PACK TEMP CONTROL BITE FIM 21-62 TASK 801 AND NO FAULTS NOTED.SDR UIEA2019122316119Control System · malfunctionedAUTO FUNCTION FOR AFT AND FWD TEMP CONTROL INOPERATIVE. PERFORMED FIM 21-61 FT 915, ALL TESTS PASSED.SDR ASAA2019122603703Warning Light · false activationZONE TEMP LIGHT ILLUMINATED ON RECALL FOR CONT CAB RESET ON MASTER CAUTION RECALL RESET. GROUNDED - YES. ACCOMPLISHED TEMP CONTROL BITE TEST, #2 FLT DECK TRIM LOGGED AS FAULT, RESETTED FAULTS, OPS NML REF B737-800 FIM 21-62 TASK 801.SDR ASAA2019124231686Warning Message · false activationCONTROL CAB ZONE TEMP ILLUMINATED ON RECALL. GROUNDED - YES. PER FIM TASK 21-62-801 BITE TEST SUCCESSFULLY ACCOMPLISHED. A/C OK FOR SERVICE.SDR ASAA2019121973638Controller · inoperativeL PACK LIGHT CAME DURING T/O ROLL. ABORTED T/O AT 75-80KTS. GROUNDED - YES. INSPECTED AND FOUND LEFT PACK/ZONE FAULT LIGHT STAYING "ON". WOULD NOT RESET. ATTEMPTED TO PERFORMED BITE PER 21-60-00-700-806-002. NO HELP. ACCOMPLISHED TASK 21-62 TASK 802. CONFIRMEDSDR DXTA2019121703213Sensor · defectiveCOCKPIT ODOR - VERY STRONG, ACRID ODOR COMING FROM THE AIR CONDITIONING SYSTEM. REMOVED PRECOOLER TEMP SENSOR AND INSTALLED NEW SERVICEABLE TEMP SENSOR AND PERFORMED OPS TEST OF PRECCOOLER RAM AIR DOOR WITH NO DEFECTS NOTED. ALL MAINTENANCE PERFORMED IAW AMMSDR ASAA2019122061640Modulating Valve · inoperativeCONTROL CABIN TEMP SELECTOR ADJUSTED TO NEAR FULL WARM POSITION, ABLE TO INCREASE/DECREASE TEMP ON SUPPLY DUCT GAUGE BUT FLIGHT DECK CONTINUES TO BE VERY COLD. GROUNDED - YES. REMOVED & REPLACED FLIGHT DECK TCV (V143) PER B737-800 AMM 21-61-21, LK CK & OPS CK SDR ASAA2019122061637Warning Light · false activationCONT CAB ZONE TEMP ILLUMINATED ON M/C RECALL. EXTINGUISHES ON RESET. GROUNDED - YES. ON DEFERRAL.SDR UIEA2019121766089Status Message · false activationCARGO A/C TEMP STATUS MSG.(<P>PERFORMED OPS CHECK ON A/C TEMP SYSTEM. OPS CHECK NORMAL. NO DEFECT NOTED IAW AMM 21-61-00.</P>)SDR ASAA2019121841598Control Valve · failedAFTER ENGINE START #1 "PACK" OVHD LIGHT ILLUMINATED / "AIR COND" MC. GROUNDED - YES. #1 CONTROLLER FAULTS THE TEMPERATURE CONTROL VALVE. THE FAULT WILL NOT RESET ON BOX AFTER RUNNING VERIFY. IN THE COCKPIT THE PACK LIGHT DOES GO OUT AFTER RESETTING THE SIX PACSDR ASAA2019121641601Warning Light · false activationZONE TEMP CONT CAB ILLUMINATES ON RECALL. GROUNDED - YES. RAN TEMP CONTROL BITE CHECK - #2 TEMP CONTROLLER HAS FLT DECK TRIM VALVE FAULT. RESET FAULT AND RAN BITE CHECK 3 TIMES - NO FAULTS NOTED REF B737-800 FIM 21-62 TASK 801.SDR DXTA2019121203191Modulating Valve · defectiveDUCT 1 OVER TEMP YELLOW CAS ILLUMINATED - DUCT 1 OVER TEMP CAS ILLUMINATED CLIMBING IN THE MID 20S FLIGHT LEVEL. FOLLOWED QRH, WENT TO MANUAL HEAT, BLEED ONE OFF, CROSS BLEED OFF AND THEN MOVED THRUST LEVER TO FLIGHT IDLE BEFORE LIGHT SLOWLY EXTINGUISHED, MAY SDR UIEA2019121216051Sensor · malfunctionedAFT CABIN ZONE TEMP INOP, LIGHT ILLUMINATES INTERMITTENTLY. REMOVED AND REPLACED CABIN AIR SENSOR IAW AMM 21-61-01. OPS CHECKED GOOD.SDR UIEA2019120906029Warning Message · false activationAFT CABIN TEMP EICAS MESSAGE DISPLAYED ON DESCENT.(<P>PERFORMED BITE ON ZONE CONTROL UNIT REF FIM 21-61 FT 803, OPS CHECK NORMAL. </P>)SDR UIEA2019121086021Modulating Valve · malfunctionedCOCKPIT TEMP REGULATION IS ERRATIC, VALVE CYCLES FROM WARM TO COLD (FULL DEFLECTION). COCKPIT TEMP VARIES CONSTANTLY, UNABLE TO COOL COCKPIT BELOW 21C. (<P>TRANSFERRED TO DMI 121748 PER MEL 21-61-04-02. PLACARDS INSTALLED AND MCC NOTIFIED.</P><P>LP 1224647 - MSDR ASAA2019120971527Warning Message · false activationCONT CABIN ZONE TEMP LIGHT ILLUMINATED DURING RECALL. GROUNDED - YES. ACCOMPLISHED BIT CK ON BOTH CONTROLLERS B737-800 AMM 21-61-00, VERIFY GREEN LIGHT W/ NO REMAINING FAULTS.SDR ASAA2019120971526Valve · faultedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATES ON MASTER CAUTION RECALL. RESETS WITH MASTER CAUTION RESET. GROUNDED - YES. FOUND PZTC 2 FAULT FLT DECK TRIM VALVE. CW B737-800 FIM 21-62 TASK 832 FAULT CLEARED COND CABIN ZONE TEMP LIGHT NO LONGER ILLUMINATES ON RECALSDR UIEA2019120976014Filter · dirtyUNABLE TO REGULATE FLIGHT DECK TEMP IN AUTO MODE. WITH DECK RHEOSTAT SELECTED TO WARM AND TRIM VALVE POINTER ON "W", COLD AIR STILL COMES OUT OF THE GASPERS. AIR EVENTUALLY BECOMES TOO WARM, BUT THEN CYCLES TOO COLD.(<P>CLEANED FLIGHT DECK ZONE TEMP SENSOR FILSDR UIEA2019120706017Warning Message · false activationEICAS MSG AFT CABIN TEMP ON CLIMBOUT.(<P>PERFORMED BITE TEST ON ZONE CONTROL BOX REF FIM 21-60 FT 804, OPS CHECK NORMAL.</P>)SDR UIEA2019120986019Valve · malfunctionedAFT CABIN TEMP ADVISORY MESSAGE. (<P>T/S PER FIM 21-60-806 AND FOUND TEMP CONTROL FAULT LIGHT FOR AFT ON. TRANSFERRED TO MDDR #121719 IAW MEL 21-61-01-02, CAT 'C', DUE DATE: 17-DEC-2019. </P><P>LP 1075672 - M3: PERFORMED FIM 21-61 FT 804, AFT ZONE TRIM AIR VASDR ASAA2019120631524Warning Light · illuminatedAFTER ENGINE START, ON MASTER RECALL CONT CAB ZONE TEMP LIGHT ILLUMINATES. EXTINGUISHES ON RESET. GROUNDED - YES. UNABLE TO DUPLICATE DEFECT - MASTER CAUTION RECALL SHOWS NO ZONE TEMP LIGHTS. BITE TEST OF PACK/ZONE TEMP CONTROLLERS NR 1 AND 2 SHOWS NO FAULTS A
Back to JASC 2160