Reports filed under 2160 · Cabin Temperature Control System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2019022603386Controller · malfunctionedUNABLE TO MAINTAIN CONSTANT COCKPIT TEMPERATURE, EITHER HOT OR COLD. PERFORMED FIM 21-61 F/T 803, AND 822. NO FAULTS FOUND. RACKED THE ZONE TEMP CONTROLLER. OPS TESTED THE CONTROLLER. OPS TESTED GOOD 21-30-17.SDR ASAA2019022748299Warning Light · false activationLEFT ZONE TEMP LIGHT ILLUMINATES ON RECALL. EXT ON RESET. GROUNDED - YES. REF B737-900 FIM 21-62 TASK 842, #2 PZTC BITE LOGGED FLT DECK TRIM VALVE FAULT. RESET FAULT MSG. PZTC BITE VERIFY TESTED GOOD WITHOUT FAULTS. VERIFIED BOTH PACKS OPS CHECKED NORMAL IN ALSDR ASAA2019022538300Control Valve · failedON MASTER CAUTION RECALL, CONT CAB ZONE TEMP LIGHT ILLUMINATES. EXTINGUISHES ON MASTER CAUTION RESET. GROUNDED - YES. REMOVED & REPLACED TCV V143 B737-800 AMM 21-61-21 OPS CHECK NORMAL.SDR ASAA2019022628303Control Valve · failedCONT CAB ZONE TEMP LIGHT ON RECALL. GROUNDED - YES. ZONE TEMP CONTROLLER BITE SHOWS HISTORY OF CONT CAB TRIM VALVE. REMOVED AND REPLACED CONT CABIN TRIM VALVE REF B737-800 AMM 21-61-21. OPERATIONAL CHECK AND LEAK CHECK GOOD. CONTROLLER BITE GOOD REF AMM 21-51-SDR ASAA2019022518304Control Valve · failedCONT CAB ZONE TEMP LIGHT ON DURING RECALL. GROUNDED - YES. PERFORMED PACK TEMP BITE TEST REF B737-800 AMM 21-62-801. R PACK CONTROLLER FLIGHT DECK TRIM VALVE FAULT LIGHT. REMOVED AND REPLACED ZONE TRIM AIR VALVE (V143) IAW AMM 21-61-21. REF B737-800 FIM 21-62 SDR ASAA2019022518298Controller · malfunctionedFWD CABIN TEMP CONTROLLER IN "AUTO" DOES NOT HOLD SELECTED TEMP. SUPPLY DUCT TEMP FLUCTUATES BETWEEN 0-60C RESULTING IN THE CABIN GETTING TOO HOT AND TOO COLD, BACK AND FORTH. GROUNDED - YES. REF B737-800 FIM 21-61 TASK 864. COULD NOT DUPLICATE. CLEANED FWD CASDR ASAA2019022518275Warning Light · false activationAFTER ENGINE START CONT CAB ZONE TEMP LITE ILLUMINATED WILL NOT EXTINGUISH AFTER FOLLOWING QRH. GROUNDED - YES. REF B737-800 FIM 21-61 TASK 801, #1 PZTC BITE TEST PASSED NO FAULT NOTED, #2 PZTC BITE TEST FAULTED FLT DECK TRIM VALVE, NO ACTIVE FAULT SHOWS AFTERSDR ASAA201902228274Warning Light · false activationCONT CABIN "ZONE TEMP" LIGHT ILLUMINATED WITH MASTER CAUTION RECALL - GOES OUT WITH RESET. GROUNDED - YES. ACCOMPLISHED PZTC BITE REF B737-900 FIM 21-62 TASK 801 NO FAULTS #1, #2 PZTC ON BIT AND PREV FLT LOGGED FLT DECK TRIM VALVE WITH A GREEN ON GO, RAN PACKSSDR UIEA2019022103298Controller · malfunctionedCAB AUTO 2 MSG. PLACED ON MDDR 107362. (<P>REPLACED CAB TEMP CONTROLLER 2. CKS GOOD PER AMM 21-31-02. CLOSED MDDR</P>)SDR ASAA2019022028261Warning System · false activationCONT CAB ZONE TEMP LIGHT ILLUM ON RECALL. ZONE TEMP LIGHT EXT WHEN MASTER CAUTION WAS RESET. GROUNDED - YES. RESET SYSTEM AND RAN BOTH PACKS FOR 20 MINUTES WITH APU AIR, THEN TESTED SYSTEM PER AMM 21-61-00-700-802-002, BOTH PACK/ZONE TEMPERATURE CONTROLLERS BISDR ASAA2019022028260Warning System · false activationCONT CAB ZONE TEMP LIGHT ILLUMINATED DURING MASTER CAUTION RECALL. GROUNDED - YES. FLIGHT DECK PRIMARY TEMP CONTROL INOP. INTERMITTENT F/D SELECTOR FAULT 21-51311, RESET & TESTS NML PER FIM 21-62 TASK 862. ETOPS SIGNIFICANT SYSTEM, GROUND VERIFICATION SUCCESSFSDR HALA2019022100059Controller · malfunctionedETOPS SIGNIFICANT SYSTEM, COCKPIT TEMP SYSTEM INOP. VERY HARD TO CONTROL TEMP IN COCKPIT IT EITHER TOO HOT OR TOO COLD. CKPT TEMP SHOWS 80*F BUT FEELS LIKE 70*F. RESET PACK CONT 1/2 AND ZONE CONT. PERFORMED ECS "BITE". NO FAULTS NOTED. OK FOR SVC.SDR UIEA201902213292Warning Message · false activation"CARGO A/C TEMP STATUS MSG"(<P>PERFORMED BITE TEST ON TEMP CONTROLLER AUX ZONE, NO FAULT SHOWN, STATUS MSG NO LONGER SHOWING. IAW FIM 21-61-00/101.</P>)SDR YENA201902228089Regulator Valve · failedFT # 1158, RETURNED TO FIELD. EXCESSIVE CABIN HEAT WHILE AT ALTITUDE FWD = 116 AFT = 106; REMOVED PACK 2 PANEL. CHECKS FLOW CONTROL VALVE SENSE LINES & CONNECTORS. NO ISSUES NOTED. PANEL REINSTALLED. HOT AIR PRESSURE REGULATING VALVE REMOVED AND REPLACED. SEESDR ASAA2019022078195Warning Light · false activationCONT CAB ZONE TEMP LIGHT ILLUMINATES ON MASTER RECALL PRESS. CLEARS ON RESET MC RESET. GROUNDED - YES. ACCOMPLISHED PZTC BITE REF B737-800 AMM TASK 21-61-00-700-806-002. FOUND RT PZTC FAULT LOGGED FLT DCK TRIM VLV. ABLE TO CLEAR FAULT AFTER BITE. LEFT PZTC LOGSDR ASAA2019021728193Warning System · false activationCONT CAB ZONE TEMP ILLUMINATED ON MASTER CAUTION RECALL. GROUNDED - YES. PERFORMED BITE TEST ON BOTH ZONE TEMP CONT PER FIM 21-61 TASK 801, FOUND TRIM VALVE FLT DECK FAULT ON CONT NR 2, CLEARED TRIM VALVE FLT DECK FAULT ON NR 2 CONTROLLER.SDR ASAA2019021528196Warning System · false activationZONE TEMP OVERHEAD LIGHT ILLUMINATED ON RECALL. CONT CAB. GROUNDED - YES. RELEASED MEL 21-21G PRIMARY FLIGHT DECK TEMP CONTROLLER INOP. PERFORMED PACK FLOW TEMP CONTROLLER BITE TEST REF MM 21-61-00. NO FAULTS FOUNDS. ZONE TMP LIGHT REMAINS EXTINGUISHED WITH RESDR ASAA2019021228156Warning System · false activationAFTER ENGINE START, "CONT CAB" "ZONE TEMP" ILLUMINATED ON RECALL, "ZONE TEMP" LIGHT EXTINGUISHED WHEN "MASTER CAUTION" LIGHT PUSHED. GROUNDED - YES. OPERATED LEFT AIR CONDITIONING PACK AND ZONE TEMP LIGHT DID NOT TURN ON. #1 AND #2 PFTC BITE TESTS GOOD; NO FAUSDR ASAA2019020928133Warning System · false activationON RECALL "CONT CAB" ZONE TEMP LIGHT REMAINED ILLUMINATED WITH AIR COND LIGHT. LIGHT EXTINGUISH WITH MASTER CAUTION RESET. GROUNDED - YES. UNABLE TO DUPLICATE DEFECT - MASTER CAUTION RECALL SHOWED NO ZONE TEMP LIGHTS, BITE OF BOTH PACK/ZONE TEMP CONTROLLERS PESDR UIEA2019020803165Valve · malfunctionedAFT CABIN TEMP EICAS MESSAGE AND AFT CABIN INOP LIGHT ILLUMINATED (<P>TRANSFERRED TO MDDR 107095 PER DDG 21-61-01-02 CAT "C" </P><P>LP 1034027-M2 REMOVED AND REPLACED TRIM AIR MODULATING VALVE IAW AMM 21-61-07 OPS CHECK OK. THIS CLEARS DMI # 107095, PLACARDS SDR ASAA2019020728132Warning System · false activationUPON RECALL ON AFTER START CHECKLIST, CONT CAB ZONE TEMP LIGHT ILLUMINATES ALONG WITH MASTER CAUTION AND AIR COND LIGHTS, ACCOMPLISHED QRH ITEMS. GROUNDED - YES. PERFORMED PACK TEMPERATURE CONTROL BITE PER FIM 21-62 TASK 801. FLT DECK TRIM VALVE FAULTED ON BITSDR ASAA2019020628104Valve · faultedCONTROL CAB SINGLE CHANNEL ZONE TEMP FAILURE LIGHT ILLUMINATED ON RECALL AND EXTINGUISHED ON RESET. GROUNDED - YES. NR 2 PZTC BITE FREV FLT SHOWS FLT DECK TRIM VALVE FAULT, RESET FAULT. VERIFIED BOTH PACKS OPS CHECKED NORMAL ON GND WITHOUT FAULTS. NR 1 AND NR SDR ASAA2019020628077Warning System · false activationZONE TEMP CONTROL ZONE CAUTION LIGHT ILLUMINATED ON RECALL AND RESET ON MASTER CAUTION RESET. GROUNDED - YES. PERFORMED FIM 21-61 TASK 801 BITE PROCS. NO HISTORY IN 30 DAYS. NO FAULT NOTED. RESET BOX. OPS NORMAL.SDR ASAA2019020528076Valve · faultedON RECALL AFTER ENGINE START, CONT CAB ZONE TEMP LIGHT ILLUMINATED. EXTINGUISHED WITH MASTER CAUTION RESET. GROUNDED - YES. BIT & PREV FLT OF NR 2 PACK/TEMP CTRLR SHOWS FLT DECK TRIM VALVE FAULT. RESET FAULT. FAULT DID NOT RETURN. BITE TEST SAME GOOD. GND VERISDR ASAA2019020428049Valve · faultedCONT CAB ZONE TEMP ILLUMINATES WITH MASTER RECALL AND EXTINGUISHES WITH RESET. GROUNDED - YES. RELEASED PER MEL 21-21G CONT CAB PRI TEMP CONT INOP. PERFORMED BITE TEST ON BOTH ZONE TEMP CONT PER FIM 21-61 TASK 801 FOUND TRIM VALVE FLT DECK FAULT ON CONT 2, CLESDR ASAA2019020428031Filter · dirtyON MASTER CAUTION RECALL AFTER START AIR COND. ZONE TEMP CONT CAB, ILLUMINATED. FOLLOWED QRH VERIFIED VALVE WORKED W/ PROCEDURE. GROUNDED - YES. RELEASED PER MEL 21-21G FLIGHT DECK PRIMARY TEMP CONT INOP. CLEANED CONT CABIN TEMP SENSOR FILTER. ACCOMP ZONE TEMPSDR ASAA2019020328155Warning System · false activationDURING CRUISE "CONT CABIN" AMBER LIGHT ILLUMINATED BRIEFLY DOES NOT ILLUMINATE ON RECALL. RAN QRC FOR ZONE TEMP. LIGHT WENT OUT BEFORE CHECKLIST COMPLETED LOWERED THE TEMP IN CONT CAB PER QRC LIGHT STAYED OUT. GROUNDED - YES. PERFORMED MASTER CAUTION RECALL NOSDR ASAA2019020328014Filter · dirtyDURING CRUISE, CONT CAB ZONE TEMP ILLUMINATED. LIGHT RESET WITH MASTER CAUTION. GROUNDED - YES. PERFORMED BITE OF BOTH PACK TEMP CONTROLLERS PER FIM 21-62 TASK 801 AND NO FAULTS FOUND. REMOVED 3 EA CABIN TEMP SENSOR FILTERS PER AMM 21-61-06. FOUND FILTHY. PERFSDR ASAA201902048013Warning Light · false activationTHE "CONT CAB" ZONE TEMP AMBER CAUTION LIGHT ILLUMINATED PERIODICALLY THROUGHOUT DURATION OF FLIGHT. DOES NOT ILLUMINATE ON RECALL. GROUNDED - YES. CYCLED C/B'S AS LISTED IN B737-800 FIM 21-61 TASK 861. PERFORMED BITE CHECK OF CONTROL TEMP CONTROL SYSTEM, WITHSDR UIEA2019020423087Unknown · unknownUNABLE TO COOL COCKPIT WITH BOTH PACK RUNNING (<P>PERFORMED ZONE CONTROL SYSTEM TEST IAW AMM 20-51-00 OPS CHECK GOOD</P>)SDR ASAA201902047997Control Valve · failedCONT CAB ZONE TEMP ON AFTERSTART RECALL. EXTINGUISHES ON RESET. GROUNDED - YES. REMOVED AND REPLACED CONT CAB TRIM AIR MODULATING VALVE V143 REF B737-800 AMM 21-61-21. RAN BOTH PACKS AT VARYING TEMPS, OPS NORMAL, PZTC BITE PASSED. ETOPS GROUND VERIFICATION SUCSDR ASAA201902047996Valve · failedLEFT PACK ZONE TEMP ILLUMINATES ON RECALL. GROUNDED - YES. REMOVED AND REPLACED LH (FLT DECK) ZONE TRIM AIR VALVE. REF AMM 21-61-21. OPS CHK GOOD.SDR ASAA2019012927971Switch · excess playSUPPLY DUCT AIR TEMP SELECTOR SWITCH HAS EXCESSIVE PLAY IN IT, FEELS LIKE IT IS CLOSE TO BREAKING. GROUNDED - YES. REPLACED CABIN TEMPERATURE SELECTOR PANEL REF AMM 21-61-07-000-803-802. OPS CHECK NORMAL.SDR UIEA2019012903049Unknown · malfunctionedALL 3 COMPARTMENT INOP LIGHTS ILLUMINATED (<P>CYCLED SYSTEM OPS CHECKED IAW AMM 21-61-00 NO DEFECTS NOTED AT THIS TIME </P>)SDR ASAA2019012827970Warning System · false activationCONT CABIN LIGHT ON RECALL. RESETS ON MASTER CAUTION RESET. GROUNDED - YES. VERIFIED - PERFORMED FIM 21-62 TASK 801 - NR 2 TEMP CNTLR SHOWED FLT DECK TRIM VALVE FAULT. PERFORMED FIM 21-67 TASK 833, FAULT RESET. RAN APU/PACKS AT VARYING CABIN TEMPS W/ NO FURTHESDR UIEA2019012803044Modulating Valve · faultyREMOVE AND REPLACE FWD ZONE TRIM AIR MODULATING VALVE PER MCC(<P>REMOVED AND REPLACED FWD ZONE TRIM AIR MODULATING VALVE PER MCC IAW AMM 21-61-07 AND OPS CHECK IS GOOD AT THIS TIME.</P>)SDR ASAA2019011827883Regulator · faultedPACK 1 REGUL FAULT GROUNDED - YES. RESET PACK 1 REGULATOR IAW AMM 21-61-00. OPS CHECK GOODSDR ASAA2019011527797Warning System · false activationON TAXI OUT AND SELECTING MASTER RECALL THE COCKPIT ZONE TEMP ILLUMINATES. GROUNDED - YES. NR 2 ZONE TEMP CONTROLLER LOGGED "TRIM VALVE" FLT DECK FAIL. PERFORMED ZONE TEMP CONTROLLER BITE TEST REF AMM TASK 21-61-00-700-806-002. RESET FAULT OP'S CHECKED NORMAL.SDR ASAA2019011427796Warning System · false activationCONT CAB ZONE TEMP LIGHT ILLUMINATED OF RECALL AFTER START. EXTINGUISHES WITH MASTER CAUTION RESET. GROUNDED - YES. PACK/ZONE TEMP CONTROLLER BITE AMM 21-61-00 OPS CHECK NORMAL GROUND VERIFICATION SUCCESSFUL.SDR ASAA2019011227744Modulating Valve · failedAFTER ENGINE START DURING MASTER RECALL, CONT CAB ZONE TEMP LIGHT ILLUMINATED. EXTINGUISHES WITH MASTER CAUTION RESET. GROUNDED - YES. REMOVED AND REPLACED FLIGHT DECK TRIM AIR MODULATING VALVE REF AMM 21-61-21. BITE CHECK GOOD. OPS AND LEAK CHECK GOOD. THIS CSDR UIEA2019011000055Unknown · malfunctionedTRIM AIR SYSTEM, STILL HAVING DIFFICULTY MAINTAINING A NORMAL TEMPERATURE (<P>PERFORMED FIM 21-61 FT 912 ZONE TEMP CONTROLLER BITE PROCEDURES, NO FAULTS NOTED, PERFORMED VISUAL ON FLIGHT DECK TRIM AIR VALVE NO FAULT NOTED, PERFORMED OPS CHECK OF FLIGHT DECK ZOSDR UIEA2019010900054Valve · faultyFLT DECK TEMP ADVISORY EICAS MSG REPEAT WRITE UP(<P>REMOVED AND REPLACED FLT DECK TRIM AIR VALVE OPS CHECK GOOD IAW AMM 21-61-01</P>)SDR HALA2019010900020Unknown · malfunctionedETOPS SIGNIFICANT SYSTEM - COCKPIT TEMPERATURE TRIM AIR VALVE, TEMPERATURE UNCONTROLLABLE, TRIM AIR TEMP GOES FROM 42C TO 124C WITH COCKPIT CONTROLLER SET ON INDEX MAKE. RESET THE C/B OF ZONE CONTROLLER AND PERFORMED THE SYSTEM TEST OF COCKPIT AND CABIN TEMP CSDR UIEA2019010900053Unknown · malfunctionedFLT DECK EICAS WOULD NOT COOL IN MANUAL SHUT OFF TRIM AIR (REPEAT WRITEUP) SET BOTH PACKS TO NORMAL CONTROL TEMP(<P>PERFORMED ZONE TEMP CONTROL AIR TEST IAW AMM 21-61-03 OPS CHECK ON NOT FAULTS OR MSG</P>)SDR ASAA2019010727707Unknown · malfunctionedDURING AFTER START CHECKLIST ON RECALL AMBER AIR COND ILLUMINATED WITH OVERHEAD ZONE TEMP. LIGHT EXTINGUISHED WITH MASTER CAUTION RESET. GROUNDED - YES. FLIGHT DECK PRIMARY TEMP CONTROL INOP. NR 2 PACK ZONE TEMP CONT SHOWS FLT DECK TRIM VALVE ON PREVIOUS FLT, SDR ASAA2019010727706Filter · dirtyCABIN TEMPERATURE ROWS 6-10 EXCESSIVELY WARM IN FLIGHT. GROUNDED - YES. NO FAULTS ON BOTH PZTC BITE. CLEANED FLT, FWD & AFT COMPARTMENT ZONE TEMP FILTERS REF AMM 21-61-06. RAN PACKS, OPS NORMAL.SDR ASAA2019010727701Warning System · false activationCLASS II MAINTENANCE MESSAGE TEMP CTL 2 GROUNDED - YES. RESET C/BS & PERFORMED CABIN TEMP CONTROL BITE TEST IAW AMM 21-63-00 OPS CHECK GOOD OK FOR SERVICE.SDR ASAA2019010627672Warning System · false activationCONT CABIN ZONE TEMP LIGHT ILLUMINATES ON RECALL. EXTINGUISHES WHEN MASTER CAUTION IS RESET. GROUNDED - YES. FLT DECK PRIMARY TEMP CONTROL INOP. ZONE TEMP CONT 2 LOGGED FLT DK TRIM VLV FAULT. CLEARED FAULT AND ACCOMP CONT BITE CK 3 TIMES. ALL SUCCESSFUL GREEN SDR UIEA2019010300003Warning System · false activation30 MINUTES INTO FLIGHT, EICAS MSG "FLT DECK TEMP", AFTER 1 HOUR IN MANUAL MODE TEMP ZONES 29/18/21 FLT DECK CONTROL IS INOP IN AUTO AND MANUAL MODES. (<P>PERFORMED BITE TEST IAW FIM 21-61 FAULT TREE 914. CLEARED MESSAGE AND PERFORMED OPS CHECK IAW AMM 21-61-07SDR ASAA2019010127644Warning System · false activationAFT ZONE TEMP ILLUMINATED ON MASTER RECALL DURING START CHECK LIST. GROUNDED - YES. ON DEFERRAL. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE AMM 21-60-00, NO FAULTS NOTED. GROUND VERIFICATION SUCCESSFUL PER AMM 21-61-21-400-801 AND SAME BITE.
Back to JASC 2160