JASC 2160
Service difficulty reports · 3,041
Reports filed under 2160 · Cabin Temperature Control System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013052203532Valve · failedMID-CABIN TEMP EICAS AND INOPERATIVE LIGHT. AUX ZONE TEMP CONTROLLER FAULTS AUX MID CABIN TRIM AIR VALVE. REPLACED AUX MID CABIN TRIM AIR VALVE.SDR SWAA2013051716194Regulator · faultyPACKS EXTREMELY TEMPERANTAL AND DIFFICULT TO MAINTAIN TEMP ON DESCENT. F/A REPORTS ODORS VARYING FROM FOUL TO AMMONIA TO SMOKEY. R & R CABIN TEMP REGULATOR IAW M/M.SDR UALA2013051703431Valve · unknownCABIN TEMP CONTROL ZONE "B" PUTTING OUT HOT AIR. TEST FAILED. VALVE LOCKED AT 20 PERCENT.SDR UALA2013051403347Computer · faultedAFTER 3 HOURS IN CRUISE, FWD CABIN TEMP RAN AWAY & HAD TO RUN IT AT THE FULL COLD STOP. NO WARNINGS OR FAILURE MESSAGES ON PFR. PREVIOUS LEGS HIT P1 CONT 7HH. REPLACED P1 CONT IAW 21-61-34-000-001-A AND 21-61-34-400-001-A. OPS TEST PASSED.SDR UALA2013050903264Controller · faultedNR 1 PACK OUTLET TEMPERATURE INDICATION INOPERATIVE ON BLEED SYSTEM ECAM PAGES. SWAPPED PACK CONTROLLERS 1 & 2 FOR TROUBLESHOOTING AND PROBLEM MOVED, RETURNED TO ORIGINAL CONFIG REF MM 21-61-34. PACK OPERATION IS NORMAL ONLY INDICATION ISSUE. REPLACED NR 1 SDR ASAA2013050894748Warning Light · false activationZONE TEMP CONT CAB ILLUMINATED ON RECALL. ACFT GROUNDED. TESTED RT PACK/ZONE CONTROLLER IAW FIM 21-62, TASK 801. FOUND A FAULT LIGHT FOR THE CONTROL CABIN TEMP VALVE. RESET PACK/ZONE CONTROLLER AND RETESTED 3 TIMES. NO FURTHER FAULT INDICATED. ALSO, DID NSDR VQI2013F00014Regulator Valve · faultyWHEN DISPATCHER RECEIVED AN AIRCELL CALL REGARDING A STRONG SMELL IN CABIN AND COCKPIT THAT SMELLED LIKE "SHARPIE MARKER". MX CONTROL SPOKE WITH CAPT AND CONFIRMED THERE WAS NO SMOKE IN CABIN OR COCKPIT AND THERE WAS NO ELECTRICAL OR BURNING SMELL. CREW SELESDR UALA2013043003026Control Panel · failedUNABLE TO RUN ALL TEST ON THE CSCP, LOCKS UP. REPLACED CSCP, OPS CHECKED GOOD.SDR UALA2013042502885Sensor · failedCOCKPIT TEMP STAYS AT 67 NO MATTER HOW WARM AUTO SELECTOR IS SET. REPLACED LEFT PACK OUTFLOW TEMP SENSOR, OPS CHECKED GOOD.SDR ASAA2013042094545Controller · malfunctionedAFTER ENGINE START , ON RECALL CONT CAB ZONE TEMP LT ILLUMINATED. LT EXTINGUISHES W/RESET. TEMP IS CONTROLLABLE W/SECONDARY CONTROLLER. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE TEST. CONTROLLER NR 2 LOGGED FLT DK TRIM VALVE FAULT. CLEARED & RERAN TEST PSDR UALA2013041802661Unknown · unknownFLT DECK WARMER THAN SELECTED WITH SWITCH ON & TEMP CONTROL IN AUTO. INOPERATIVE LIGHT EXISTING. 82' WITH FLT DECK CONTROLLER IN FULL COLD. PERFORMED FILTER AND SENSOR CLEANING. TEMP CONTROLLER LISTS NO FAULTS. BITE CHECKED GOOD. OPERATED LEFT PACK INSDR UALA2013041202503Unknown · malfunctionedFWD CABIN TEMP CONTROL ALMOST IMPOSSIBLE TO CONTROL. CONSTANT COMPLAINTS. SAMC TEXT: NO HELP WITH HOT AIR SWITCH TURNED OFF. BARELY MOVE CONTROLLERS WITH HOT AIR OFF AND STILL WAY UP AND DOWN AFTER PERIOD OF TIME. PEOPLE ARE REALLY COMPLAINING. OUTPUT NOSDR UALA2013040802301Valve · failedCABIN TEMP, ALL ZONES EXTREMELY ERRATIC AND IMPOSSIBLE TO CONTROL. ROAMS TO EXTREME. REPLACED HOT AIR PRESSURE REGULATING VALVE. OPS CHECKED GOOD.SDR ASAA2013040494369Valve · malfunctionedFWD CABIN ZONE TEMP MASTER CAUTION COMES ON WHEN PUSHING MASTER CAUTION. IT RESETS WHEN RESET IS PUSHED. ACFT GROUNDED. R & R FWD CABIN ZONE TEMP VALVE OPS AND LEAK CHECKED GOOD IAW AMM 21-61-21-000-801.SDR UALA2013040402246Actuator · faultyCOCKPIT TEMP TOO WARM. UNABLE TO GET BELOW 82 DEGREES WITH FULL COLD SELECTED. FOUND MIXER FLAP ACTUATOR FAULTING. REPLACED PER MM 21-51-52. OPS CHECK NORMAL ON GROUND.SDR UALA2013040402216Sensor · malfunctionedTEMP CONTROL ABNORMAL. COCKPIT AND FWD CABIN REQ TEMP KNOBS TURNED FULL CTR CLOCKWISE TO COOL. REPLACED OUTLET TEMP SENSOR AND WATER SENSOR IAW MM. OPERATED PACK, PACK OPS NORMAL.SDR UALA2013040302170Valve · faultedHOT AIR FAULT DISPLAYED ON UPPER ECAM SCREEN. REPLACED TRIM PRESSURE REGULATING VALVE, OPS CHECKED GOOD.SDR ASAA2013033094287Filter · malfunctionedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED DURING RECALL. EXTINGUISHES WHEN RESET IS PUSHED. PERFORMED BITE TEST ON BOTH ZONE TEMP CONTROLLERS. NR 2 ZONE TEMP CONTROLLER SHOWED FAULT FOR FLIGHT DECK TRIM VALVE. REPLACED CABIN TEMP SENSOR FILTER IAW AMM 21-6SDR UALA2013032802002Regulator Valve · failedCARGO HEAT ON FULL HOT FOR APPROX 20-30 MINS AND AFT CARGO TEMP IS GOING DOWN, CARGO TEMP IS 56 DEGREES, HOT AIR VALVE DOES NOT OPEN WITH TEMP AT FULL HOT. REPLACED TRIM AIR VALVE AND PRESSURE REGULATOR VALVE PER MM.SDR ASAA2013032594263Controller · malfunctionedCONT CAB LIGHT ON RECALL RESETS ON MC RECALL. CONFIRMED FAULT, CONT CABIN ZONE TEMP LIGHT ILLUMINATES ON MASTER RECALL. T/S FOUND NR 2 ZONE TEMP CONTROLLER WITH FLT DECK TRIM VALVE FAULT LIGHT ILLUMINATED AFTER INTERROGATION. PERFORMED NR 1 & NR 2 CABIN TESDR ASAA2013032594258Warning Light · false activationCONT CABIN ZONE TEMP LIGHT ILLUMINATES ON RECALL, RESETS. VERIFIED ZONE LIGHT WITH RECALL. PERFORMED M/M TASK 21-61-00-700-806-002. INITIAL FIND WAS FAULT LOGGED FOR NR 2 TEMP CONTROLLER FLT DECK TRIM VALVE. TEMP CONTROLLER BITE TEST VERIFY TEST PASSED WITHSDR ASAA2013031794211Valve · malfunctionedCONT CAB ZONE TEMP LIGHT ILLUMINATES ON RECALL, RESETS WITH MASTER CAUTION. ACFT GROUNDED. ZONE TEMP CONTROLLER NR 2 BITE FAULTS FLT DECK TRIM VALVE ON BITE AND PREVIOUS FLIGHT. REPLACED FLIGHT DECK TRIM VALVE (V143). BITE CHECK PASSES AND LEAK CK OK. REF SDR UALA2013030501321Controller · faultyCABIN TEMP REFERENCE IS BLANK ZONE B. REPLACED TRIM VALVE PER MM, OP CHECKED GOOD. CHECKED ALL WIRES FROM CTC TO ZONE 'B' TRIM AIR MODULATING VALVE, CHECKED GOOD. SWAPPED VALVE WITH KNOWN GOOD VALVE, CHECKED GOOD. CONFIRMED BAD VALVE. RESET CTC AND OPERASDR ASAA2013030394050Warning Light · false activationCONT CAB ZONE TEMP ILLUMINATED ON RECALL EXTINGUISHES ON MASTER CAUTION RESET. PERFORMED PACK/ZONE TEMP CONTROLLER BITE CK IAW AMM REF 21-61-00-700-806-002, TEST PASSED, OPERATED PACKS NO FAULTS NOTED, CONT CAB ZONE TEMP DOES NOT ILLUMINATE ON RECALL.SDR ASAA2013022593989Warning Light · false activationZONE TEMP LIGHT ON RECALL, EXTINGUISHES ON RESET. PERFORMED BITE IAW 21-62, TASK 801. FOUND NR 2 CONTROLLER FAULTS FLT DECK ZONE VALVE AND FLT DECK TRIM VALVE. ABLE TO RESET FAULTS. GROUND RAN RT PACK AND PERFORMED BITE AGAIN. NO FAULTS LOGGED.SDR ASAA2013022493986Warning Light · illuminatedCONT CABIN ZONE TEMP LIGHT ILLUMINATED. RESET FOR QRH. LIGHT ILLUMINATED TWICE MORE CONT EXTINGUISHED WHEN RECALL WAS SELECTED. BITE SHOWED NR 2 ZONE TEMP CONTROLLER FLT DECK TRIM VALVE FAULT, PREVIOUS BUT NOT CURRENT, VERIFY GOOD. NO HISTORY, OPS NORMAL.SDR ASAA2013021993943Controller · malfunctionedCONT CAB ZONE TEMP ILLUMINATED ON RECALL AFTER ENGINE START. RACKED NR 2 ZONE TEMP CONTROLLER IAW 21-61-20 AND PERFORMED SATISFACTORY BIT CHECK OF NR 2 ZONE TEMP CONTROLLER IAW AMM 21-61-20.SDR ASAA2013021693906Warning Light · false activationCONT CAB ZONE TEMP LIGHT ON. IAW FIM 21-62 / 842 C/W INIT EVAL - NO DEFECT NOTED, & C/W ZONE TEMP CONTROLLER BITE - NO DEFECT NOTED.SDR UALA2013021200839Controller · faultedCOCKPIT TEMP COMMANDING 100 DEGREES WITH CONTROL ON FULL COLD. TEMP UNCONTROLLABLE. REPLACED TEMP ZONE CONTROLLER. OP CHECKED OKAY.SDR ASAA2013020593829Filter · cloggedCONT CABIN ZONE TEMP LIGHT ILLUMINATES ON MASTER CAUTION RECALL. REPLACED FLIGHT COMPARTMENT ZONE - CABIN TEMP SENSOR FILTER REF AMM 21-61-06-400-801. PERFORMED PACK/ZONE TEMP CONTROLLER BITE CHECK, CHECKS GOOD REF FIM 21-62, TASK 801.SDR ASAA2013020493825Controller · malfunctionedON RECALL CONT CAB ZONE TEMP LIGHT ILLUMINATES AND EXTINGUISHES WITH PUSH TO RESET. FOUND FAULT ON NR 2 CONTROLLER FLIGHT DECK TRIM VALVE. ACCOMPLISHED RESET AND TEST PROCEDURES IAW TASK 21-61-20-400-801. FAULT CLEARED AND DID NOT REAPPEAR.SDR UALA2013020500710Valve · failedFLIGHT DECK TEMP INOPERATIVE ILLUMINATED IN AUTO. FLT DECK TEMP OPERATES NORMALLY IN MANUAL. FOUND FLIGHT DECK CABIN TEMP SENSOR CLOGGED WITH LINT. CLEANED SENSOR AND ACCOMPLISHED FLIGHT DECK TRIM AIR VALVE OPERATIONAL CHECK. NO FURTHER FAULTS NOTED AT TEMSDR UALA2013020100614Controller · failedAFT CABIN AUTO CONTROL FAILURE. INOPERATIVE LIGHT ON. AFT ZONE TEMP CONTROLLER FAULTED. REPLACED TEMP CONTROLLER PER MM, OPS CHECKED NORMAL.SDR UALA2013020100610Sensor · dirtyUNABLE TO CONTROL CABIN TEMP. CLEANED TEMP SENSORS AND OPS CHECKED OKAY.SDR ASAA2013012793767Controller · no indicationZONE TEMP CONTROLLER NR 2 HAS NO LIGHTS ILLUMINATED WHEN SELF TEST PRESSED. TROUBLESHOT IAW WDM 21-51-22. PERFORMED CONTINUITY CHECK FROM C15 OF D3860A TO CBC1161 AND READ 40 OHMS. REMOVED CONNECTOR D41822P AND PERFORMED GOOD CONTINUITY CHECK FROM D41822P TSDR ASAA2013012693746Warning Light · false activationCONT CABIN AMBER ZONE TEMP LIGHT ILLUMINATED, MASTER CAUTION RESETS LIGHT. PERFORMED BITE CK ON NR 1& NR 2 ZONE TEMP CONTROL. NR 2 SHOWED TRIM VALVE FAULT RESET CONTROLLER, NO FAULT, GROUND VERIFICATION TEST OK IAW AMM 21-61-00-700-806-002.SDR ASAA2013012593745Controller · malfunctionedCONTROL CAB ZONE TEMP LIGHT ILLUMINATED DURING MASTER CAUTION RECALL. PERFORMED AN OPS CHECK OF THE PACK SYSTEMS IAW AMM 21-00-00. ALSO, PERFORMED A BITE CHECK OF THE ZONE TEMP CONTROLLERS. NO FAULTS NOTED. OK FOR SERVICE.SDR ASAA2013012493744Controller · malfunctionedCONT CAB ZONE TEMP ILLUMINATES ON RECALL AND TURNS OFF ON MASTER CAUTION RESET. PERFORMED GOOD BITE PROCEDURE ON ZONE TEMP CONTROLLER NR 1. FAULT CLEARED, REF FIM TASK 21-62, TASK 801.SDR ASAA2013012393726Warning Light · false activationCONT CAB ZONE TEMP ILLUMINATED ON RECALL AFTER ENG START ACCOMPLISHED GROUND CHECKLIST. AFTER SELECTING COOLER TEMP AND PUSHING TRIP RESET ZONE TEMP LIGHT STAYED ILLUMINATED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE IAW FIM 21-62. NO DEFECTS NOTED.SDR UALA2013012300401Control Valve · failedDURING DESCENT THROUGH 12000, A/C PACK OFF MESSAGE ILLUMINATED. BITE CHECK OF ZONE TEMP CONTROLLERS SHOWS LT PACK TEMP CONTROL VALVE FAULTED. WILL NOT CLEAR. REMOVED AND REPLACED LEFT PACK TEMP CONTROL VALVE, INSTALLATION TEST NORMAL. NO LEAKS NOTED.SDR UALA2013012200389Valve · faultyCABIN ZONE TEMP SYNOPTIC SHOWS ZONE C BLANK. F/A REPORT AREA WARM. REPLACED ZONE C TRIM AIR MODULATING VALVE, TEST PASSED ALL INDICATIONS NORMAL.SDR ASAA2013012093703Filter · dirtyCONT CAB LIGHT ON RECALL ZONE TEMP. BITE TEST OF PACK/ZONE TEMP CONTROLLERS SHOWED NO FAULTS AND VERIFY TEST PASSED FOR BOTH WITH NO TRIM VALVE FAULTS. FOUND CONTROL CABIN ZONE TEMP SENSOR AND FILTER VERY DIRTY. CLEANED TEMP SENSOR IAW MM 21-61-10-100-801 ANSDR ASAA2013011293673Sensor · faultedAFTER ENGINE START, ON RECALL, CONTROL CABIN ZONE TEMP ILLUMINATEED FOLLOWED QRH 2.15. RESETS WITH MASTER CAUTION RESET. R & R T478, OPS CHECKED GOOD IAW MM 21-61-00.SDR UALA2013011100180Valve · faultedCOND TEMP SENSOR R BOTH RIGHT PACK CONDENSER INLET TEMPERATURE SENSORS FAILED. STATUS MSG01- LATCHED DESCENT MODE DEPENDENT; LOW LIMIT VALVE (R PACK) AC MOTOR IS NOT IN COMMANDED POSITION. DB- CABIN TEMPERATURE CONTROLLER (R CHAN1) MSG02- LATCHED DESCENT MODSDR UALA2013010700083Valve · faultyFWD CABIN TEMP EICAS, UNABLE TO OPEN VALVE EVEN IN MANUAL. PULLED CIRCUIT BREAKERS H2 & H5. REPLACED THE AUXILARY FORWARD TRIM AIR MODULATING VALVE (V152) IAW AMM. ACCOMPLISHED OPS TEST IAW AMM, ALL CHECKED GOOD.SDR ASAA2013010593610Valve · failedZONE TEMP LIGHT ON RECALL. PERFORMED PACK ZONE TEMP CONTROLLER BITE TEST ON NR 1 & 2 CONTROLLERS. NR 2 CONTROLLER FLIGHT DECK TRIM VALVE FAILED. RESET & VERIFIED TWICE. NO HISTORY FOR 90 DAYS. REF AMM 21-60-00.SDR UALA2013010400057Bypass Valve · faultyUNABLE TO GET CABIN FWD AND AFT ABOVE 68 DEGREES WITH BOTH FWD AND AFT CONT SET AT FULL WARM. SAMC TEXT: DUE TO LAST LEG REPORT OF P2 BYPASS VALVE FAULT, CHANGE 30HH BYPASS VALVE REF AMM 21-61-53, PCN 644-9042. REPLACED TURBINE BYPASS VALVE ON NUMBER 2 PACSDR ASAA2013010293595Sensor · looseTHERE IS A SOUND COMING FROM THE OVERHEAD PANEL OVER SEAT 1D AND BELOW THE CABIN BIN. FOUND VIBRATING FWD CABIN TEMP SENSOR. SECURED SENSOR AND VIBRATION GONE REF AMM 21-61-10.SDR ASAA2013010293594Valve · malfunctionedCONT CAB ZONE TEMP LIGHT ILLUMINATED ON TAXI OUT. ACFT GROUNDED. ZONE TEMP CONTROLLER NR 2 SHOWS FLT DECK TRIM VALVE FAULT ON BITE AND PREVIOUS FLT. REPLACED CONT CAB ZONE TEMP VALVE AS REQUIRED. OPS CHECKED GOOD, REF AMM 21-61-21-400-801.SDR ASAA2013010193589Warning Light · illuminatedON RECALL, AIR CONDITIONER & ZONE TEMP ILLUMINATED. EXTINGUISH ON RESET. NR 2 PACK ZONE TEMP CONTROLLER LOGGED FLT DECK TRIM VALVE FAULT. ACCOMPLISHED FIM TASK 21-62, TASK 832. FAULT CLEARED AND DID NOT COME BACK ON SUBSEQUENT TESTS. RAN PACKS WITH NO FAU
Back to JASC 2160