JASC 2160

Service difficulty reports · 3,041

Reports filed under 2160 · Cabin Temperature Control System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2160'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SPOA80310272013Control Valve · failedDUCT OVERHEAT LIGHT ON DURING CRUISE, EMERGENCY PRESSURIZATION LIGHT FLICKERING, CABIN ALTITUDE 5000 AGL. TROUBLESHOT AND FOUND FAILURE OF TORQUE MOTOR TEMPERATURE CONTROL VALVE, LEAR IPC CHAP 21-64-10, FIG 10, ITEM 3, SOLENOID.Oct 27, 2013 · N803GJ · Lear 55LEARSDR CALA2013102292263Unknown · malfunctionedHISTORY OF FLIGHT DECK TEMPS UNCONTROLLABLE. IAW SVC TIP MM 21-61-100E & PERFORM ALL STEPS OF FIM 21-60-00 FIG.106. CHECKED & INSPECTED FLIGHT DECK ZONE TEMP SENSOR FAN.Oct 19, 2013 · N579UA · Boeing 757222SDR ASAA2013101796191Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. NR 2 CONTROLLER SHOWS FLT DECK TRIM VALVE FAULT. RAN BITE AND FAULT CLEARED. BITE OPS NORMAL REF AMM 21-61-20.Oct 17, 2013 · N403AS · Boeing 737990ERSDR SWIA201334957Unknown · malfunctionedLT PACK BLOWS HOT AIR ONLY & SMOKES. FLT#6207 REPLACED THE LT PACK TEMPERATURE CONTROL VALVE, LT PACK DUCT TEMPERATURE SENSOR & LT ACM. PN 2204540-4 SN ON 986R SN OFF 17-254; PN 627962-2 PN 979990-1 SN ON 809 SN OFF 2008.Oct 16, 2013 · N586SW · Emb EMB120ERSDR DALA13050399215Controller · failedFLIGHT CREW REPORTED SLIGHT HAZE AND WARM AIR COMING FROM REAR OF ACFT. R & R LEFT TEMPERATURE CONTROL IAW AMM. OPS CHECKED GOOD. MCO/PLAC REMOVED.Oct 6, 2013 · N915DN · Doug MD9030SDR CALA2013100891872Regulator · faultyCREW OBSERVED ON COND PAGE AFT CARGO HEAT REG VLV GREEN & CLOSED, PIT TEMP 60. WHEN SELECTING TEMP SELECTOR FULL WARM, TEMP VLV & REG VLV REMAIN CLOSED. NO FAULTS DISPLAYED ON ECAM. REPLACED REGULATOR & TRIM VLV, OPERATIONS CHECKED OK.Oct 5, 2013 · N461UA · Airbus A320232SDR ASAA2013091896003Valve · faultedON MASTER RECALL CONT CABIN ZONE TEMP LIGHT ILLUMINATED. LIGHT EXTINGUISHES WITH MASTER CAUTION. ACFT GROUNDED. FOUND FLT DECK TRIM VALVE FAULT ON NR 2 TEMP CONTROLLER. ACCOMPLISHED BITE CHECK ON BOTH TEMP CONTROLLERS, FAULT CLEARED.Sep 18, 2013 · N537AS · Boeing 737890SDR ASAA2013091195949Warning Light · illuminatedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATES ON RECALL, RESETS WITH MASTER CAUTION RESET. ACFT GROUNDED. VERIFIED CONTROL CABIN ZONE TEMP ANNUNCIATOR ILLUMINATOR ON RECALL. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TEST FOUND FLT DECK TRIM VALVE FAULT LT ON NR 2Sep 11, 2013 · N568AS · Boeing 737890SDR CALA2013091191215Valve · faultyAUX MID ZONE TEMP CONTROLLER FAULTING AUX MID TRIM VALVE. REPLACED AUX MIDTRIM VALVE, NO HELP, STILL FAULTS AUX TRIM VALVE ON CONTROLLER & UNABLE TO MOVE VALVE POSITION FROM FLIGHT DECK. SUSPECT BAD VALVE FROM STOCK PCN (643-9023). REPLACED AFT AUX TRIM VALSep 8, 2013 · N651UA · Boeing 767322SDR CALA2013091091187Unknown · malfunctionedFWD CABIN TEMP TRIM VALVE FAILED. ACCOMPLISHED CFDS TEMP CONTROL TEST. TESTED OK. OPERATED PACKS & RAN FWD TEMP COLD TO HOT & BACK TO COLD, VALVE OPERATIONS CHECKED NORMAL, NO FAULTS.Sep 8, 2013 · N810UA · Airbus A319131SDR CALA2013090991145Unknown · malfunctionedREPEAT GRIP LT PACK UNCONTROLLABLE ALL MODES TEMPERATURE IN COCKPIT 98 DEGREES. COMPLIED WITH ZONE TEMPERATURE TOO HOT AMM 21-61-00, PACK TEMPERATURE CONTROL BITE 21-51-00 FIG 104, ZONE TEMPERATURE CONTROL BITE TEST 21-60-00 & OPERATIONS CHECKED 21-51-00. NOSep 8, 2013 · N576UA · Boeing 757222SDR ASAA2013090495922Filter · dirtyUNABLE TO CONTROL TEMP IN FWD CABIN WITH FWD CABIN TEMP CONTROL IN AUTO. AT 12 O`CLOCK POSITION SUPPLY DUCT IS BETWEEN 0 DEGREES AND 2 DEGREES C AT 2 O`CLOCK POSITION SUPPLY DUCT IS BETWEEN 60-70 DEGREES C. IN OFF TEMP IS STEADY AT 20 DEGREES C. ACFT GROUNDEDSep 4, 2013 · N594AS · Boeing 737890SDR ASAA2013082695887Controller · malfunctionedCONTROLLER IN CABIN DOES NOT WORK RIGHT IN AUTO. IN FULL COLD POSITION SUPPLY DUCT TEMP REACHED 60 C. ACFT GROUNDED. PERFORMED FIM TASK 21-61-861, NO FAULTS FOUND. PERFORMED BITE TEST ON BOTH TEMP CONTROLLERS IAW MM 21-61-801, NO FAULTS FOUND. INSPECTED ALLAug 26, 2013 · N588AS · Boeing 737890SDR ASAA2013082495877Control Module · malfunctionedAIR TEMP SUPPLY DUCT SELECTOR SWITCH VERY STIFF AND DOES NOT LINE UP WITH SELECTED TEMPS. ACFT GROUNDED. CONFIRMED FAULT. REPLACED TEMP CONTROL MODULE. SYS GROUND VERIFICATION SUCCESSFUL, REF MM 21-61-15, 21-61-32.Aug 24, 2013 · N585AS · Boeing 737890SDR ASAA2013082295871Valve · failedFORWARD CABIN ZONE TEMP ILLUMINATED DURING RECALL. LIGHT EXTINGUISHED WHEN MASTER CAUTION RESET IAW QRH 215. ACFT GROUNDED. NR 2 ZONE TEMP CONTROLLER BITE REF FIM 21-62, TASK 801 SHOW ZONE TRIM VALVE FAULT. FOUND AFT COMPARTMENT PASS. ZONE TRIM AIR MOD VALVEAug 22, 2013 · N519AS · Boeing 737890SDR ASAA2013082195859Sensor · dirtyAFT F/A SAID ITS COLD IN AFT PORTION OF CABIN. DUCT TEMP AT 20-22C W/ AFT CABIN TEMP SHOWING 30-32. TEMP KNOB MOVED TO 3-4 O`CLOCK POSITION WITH NO INCREASE IN HEAT. DISCUSSED W/ MX CONTROL VIA SAT COM. POSSIBLE AFT CABIN TEMP PROBE FAILURE/ CONTAMINATIONAug 21, 2013 · N558AS · Boeing 737890SDR LR7A2013082100706Control Box · unknownDURING SCHEDULED FLIGHT, CREW EXPERIENCED SMOKE AND FUMES ON FLIGHT DECK. BOTH CARGO AND FLIGHT DECK AIR CONDITIONING PACKS WERE SECURED AS A PRECAUTION AND AN AIR RETURN WAS EXECUTED. AFTER LANDING, A VISUAL INSPECTION OF THE CARGO COMPARTMENT AIR CONDITIAug 21, 2013 · N403LC · Lkheed 382GSDR CALA2013082290671Valve · faultyFLIGHT DECK TOO HOT WITH LT A/C PACK IN AUTO. ALSO TOO HOT WITH COCKPIT TRIM AIR OFF. REPLACED FLIGHT DECK TRIM AIR VALVE PER MM, OPERATIONS CHECKED NORMALAug 19, 2013 · N545UA · Boeing 757222SDR CALA2013081990561Modulating Valve · faultyFLIGHT DECK TRIM AIR VALVE DOES NOT MOVE IN AUTO OR MANUAL. REPLACED ZONE A, TRIM AIR MODULATING VALVE IAW AMM 21-61-02. TEST PASSED. PERFORMED LEAK CHECK. NO LEAKS DETECTED.Aug 19, 2013 · N209UA · Boeing 777222SDR ASAA2013081795822Warning Light · false activationON RECALL, CONT CABIN ZONE TEMP LIGHT ILLUMIINATED. RAN QRC AND LIGHT STAYED ON. ACFT GROUNDED. FLT DECK TRIM VALVE FAULT NR 2 ZONE TEMP CONTROLLER. RESET AND TESTS NORMAL IAW FIM 21-61, TASK 801. GROUND VERIFICATION SUCCESSFUL.Aug 17, 2013 · N587AS · Boeing 737890SDR CALA2013081990506Sensor · dirtyCOCKPIT TEMP CONTROL INOP COCKPIT TEMP AT 84 WITH ALL 3 SELECTORS AT FULL COLD. CLEANED COCKPIT TEMP SENSOR. GROUND AND SYS MCDU TEST OK.Aug 16, 2013 · N492UA · Airbus A320232SDR ASAA2013081295783Filter · dirtyMAIN CABIN TEMP HARD TO CONTROL WITH FWD & AFT CONTROLLERS ABOUT 10-11:00 O`CLOCK POSITION, AFT CABIN TEMP ABOUT 26-28C. AFTER 45 MINS AT FULL COLD AND SUPPLY TEMP AT 8-10C CABIN FINALLY COOLED TO ABOUT 21-22C. FWD AND AFT CONTROLLERS TO MAINTAIN 21C MUST BEAug 12, 2013 · N402AS · Boeing 737990ERSDR CALA2013081390422Controller · faultyTEMP IN CABIN AND COCKPIT VERY SLOW TO COOL DOWN. 1 HR INTO FLT STILL 10. REPLACED RT CABIN TEMP CONTROLLER, CHECKED GOOD.Aug 11, 2013 · N794UA · Boeing 777222SDR CALA2013081290343Valve · inoperativeDURING CLIMB PASSING 18000 FT, COCKPIT AND FWD CABIN WENT VERY HOT. CONTINUE HOT UNTIL TRIM AIR OFF. AT CRUISE, WENT BACK TO AUTO AND TEMPS OK. DEACTIVATED TRIM AIR VALVE.Aug 10, 2013 · N579UA · Boeing 757222SDR ASAA2013080995769Sensor · dirtyTEMPERATURE WOULD NOT COOL DOWN FROM ROW 6 TO ROW 10 IN CABIN. REST OF CABIN COOLED NORMALLY. ACFT GROUNDED. C/W FIM 21-61, TASK 801, CABIN TEMP CONTROLLER BITE TEST, NO FAULTS FOUND. BITE TESTS GOOD. C/W CABIN TEMP CONTROL & INDICATION OP TEST IAW AMM TASAug 9, 2013 · N593AS · Boeing 737890SDR CALA2013080990304Sensor · cloggedUNABLE TO MAINTAIN COCKPIT TEMP IN ANY MODE. TEMP VARIES FROM 61-85. FOUND SENSOR CLOGGED, CLEANED SENSOR AND OPERATES NORMALLY NOW.Aug 9, 2013 · N515UA · Boeing 757222SDR CALA2013080990291Controller · inoperativePACK LOW FLOW. UNACCEPTABLE TEMP, COCKPIT TEMP 89 DEGREES, CABIN TEMP 82 IN CLIMB. LT PACK OUT TEMP RUNNING +5 DEG. RT 10, R & R NR 1 PACK TEMP AND ZONE TEMP CONTROL IAW AMM. OPS CHECKED GOOD.Aug 8, 2013 · N411UA · Airbus A320232SDR CALA2013080790196Controller · faultyDURING NORMAL GROUND OPS, FLT DECK TEMP ROSE TO 80 IMMEDIATELY AFTER TAKE OFF. REPLACED THE ZONE CONTROLLER. OPS CHECKED NORMAL.Aug 6, 2013 · N429UA · Airbus A320232SDR CALA2013080590163Sensor · looseAFT CABIN TEMP UNCONTROLABLE WITH FULL HOT- HOT AIR SELECTOR AT 2.60 DRG. PAC 1 OUTLET WAS ACP CFDS CAB TEMP TEST AND OPS CHECK NORMAL, RAN PACK 1 AND TEMP FOLLOWED AND RESPONDED TO COCKPIT INPUT, REMOVED AND INSPECTED AFT CABIN TEMP SENSOR AND FOUND CLEAN. FOAug 4, 2013 · N497UA · Airbus A320232SDR UALA2013072605262Controller · faulty"PACK R" MESSAGE SHOWS ON STATUS. REPLACED RT CABIN TEMP CONTROLLER IAW MM, OPS CHECKED NORMAL.Jul 24, 2013 · N217UA · Boeing 777222SDR ASAA2013071195556Controller · faultedON APPROACH LANDING CHECKLIST RECALL MASTER CAUTION LIGHT STAYED ON LOOKED UP, AFT CAB ZONE TEMP LT ON RESET, LIGHT WENT OUT. ACFT GROUNDED. AFT CABIN ZONE TEMP ANNUNCIATOR DOES NOT ILLUMINATE. WITH MASTER CAUTION RECALL. NR 2 TEMP CONTROLLER DOES SHOW ON PJul 11, 2013 · N592AS · Boeing 737890SDR ASAA2013071095542Control Valve · failedCOULD NOT COOL AFT CABIN - NO LIGHTS ILLUMINATED. AFT SUPPLY DUCT STAYS AT 28 DEGREES C, AFT CABIN TEMP ( PASS CAB) INDICATES 32 DEGREES C. MX CONTROL TROUBLESHOOT INFLIGHT WAS UNSUCCESSFUL. ACFT GROUNDED. CONFIRMED PROBLEM. RAN VERIFY TEST ON NR 1 ZONE TJul 10, 2013 · N592AS · Boeing 737890SDR ASAA2013070995536Unknown · unknownF/A`S REPORT CABIN TOO WARM BETWEEN ROWS 6 & 10. PILOTS COOLED CABIN (FWD) NUMEROUS TIMES TO ABNORMALLY LOW SETTINGS AND STILL REPORTED TOO WARM. ACFT GROUNDED. PERFORMED BITE ON ZONE TEMP CONTROLLERS. NO FAULTS LOGGED. PERFORMED CABIN TEMP CONTROL OPS CHEJul 9, 2013 · N402AS · Boeing 737990ERSDR ASAA2013070895507Control Valve · failedZONE TEMP CONT ON WITH RECALL, RESETS WITH MASTER CAUTION. ACFT GROUNDED. ACCOMPLISHED PACK ZONE TEMP CONT BITE ON BOTH CONTS. NR 1 SHOWS NO FAULTS, NR 2 SHOWS FAULT FOR FLT DECK CONT VALVE (V143). CLEARED FAULT. CLEANED ALL 3 TEMP SENSOR FILTERS. RAN BOTJul 8, 2013 · N596AS · Boeing 737890SDR ASAA2013070795492Warning Light · illuminatedON RECALL, AFT CABIN ZONE TEMP LIGHT ILLUMINATED, RAN CHECKLIST. LIGHT WENT OUT WHEN MASTER CAUTION WAS PUSHED. ACFT GROUNDED. PERFORMED BIT TEST OF NR 1 AND NR 2 PACK/ZONE TEMP CONTROLLERS, CONTROL FAULT STANDBY PACK ILLUMINATED ON RECALL CONTROLLER NR 1 RJul 7, 2013 · N592AS · Boeing 737890SDR UALA2013070504686Controller · faultyCABIN TEMP EICAS MESSAGES ON TOUCH DOWN. REMOVED AND REPLACED CABIN ZONE TEMP CONTROLLER. PER AMM. CHECKED GOOD.Jul 4, 2013 · N669UA · Boeing 767322SDR UALA2013062704513Valve · faultyZONE "E" TRIM VALVE. ZONE "E" TRIM VALVE IS FAULTING FOR PAST SEVEN LEGS WITH MAINT MESSAGE 21-20006. TROUBLESHOT IAW FIM 21-61, TASK 841. REPLACED ZONE E TRIM VALVE. VALVE TESTED NORMAL IAW FIM 21-61, TASK 841 AND AMM 21-61-02Jun 26, 2013 · N216UA · Boeing 777222SDR UALA2013062704487Controller · inoperativeMID CABIN AUTO TEMP CONTROLLER INOPERATIVE.Jun 26, 2013 · N674UA · Boeing 767322SDR CA130624003Mixing Valve · damaged(CAN) DURING INVESTIGATION INTO PILOT REPORTED DEFECT, FULL COLD SELECTED, LT SIDE HOT, MAINTENANCE PERFORMED A FUNCTIONAL CHECK OF THE MIXING VALVE AND FOUND THE BUTTERFLY VALVE TO BE STAYING IN THE OPEN POSITION WHEN SELECTED CLOSED. VALVE ASSY REMOVED. THJun 21, 2013 · Swrngn SA227ACSDR UALA2013061304096Indicator · inaccurateFWD CABIN TEMP DISPLAY READS INCORRECTLY AT 50 DEGREES. REPLACED ZONE TEMP INDICATOR, OPS CHECKED NORMAL.Jun 11, 2013 · N562UA · Boeing 757222SDR ASAA2013061195074Control Valve · malfunctionedCONT CAB ZONE TEMP LIGHT COMES ON DURING MASTER CAUTION RECALL. ACFT GROUNDED. CONFIRMED FAULT. BITE TEST ON LT CONTROLLER ZONE TEMP CONTROLLER SHOWS LT TCV FAULT. R & R LT PACK TCV (V139) REF AMM TASK 21-61-21, OPS CK NORMAL.Jun 11, 2013 · N592AS · Boeing 737890SDR DALA13028419235Controller · failedDECLARED MEDICAL EMERGENCY ON FINAL. RT PACK UNABLE TO COOL ACFT. MULTIPLE PEOPLE BECAME ILL ON FLIGHT AND ONE PASSENGER PASSED OUT DUE TO CABIN BECOMING UNCOMFORTABLY HOT. MX TROUBLESHOT AND REMOVED AND REPLACED PACK AUTO TEMPERATURE CONTROLLER AND ANTICIPJun 10, 2013 · N935DN · Doug MD9030SDR ASAA2013060494988Controller · erraticFWD CAB TEMPERATURE CONTROLLER IS ERRATIC. UNABLE TO MAINTAIN THE IDEAL 21C -22C SUPPLY DUCT TEMP. AT APPROX 9 O`CLOCK POSITION THE SUPPLY DUCT TEMP IS 10 C IF THE TEMPERATURE CONTROLLER IS CLOCKWISE THERE IS NO CHANGE IN THE DUCT TEMPERATURE UNTIL ABOUT THJun 4, 2013 · N537AS · Boeing 737890SDR UALA2013060503902Valve · faultyTRIM AIR PRSOV RT. R & R RT TRIM AIR PRSOV IAW AMM 21-62-01. INSTALLATION TEST PASSED. LEAK CHECKED OK.Jun 1, 2013 · N212UA · Boeing 777222SDR UALA2013060303838Controller · faultyENGINES STAY IN HIGH IDLE. PROBLEM WAS CAUSED BY BOTH CHANNELS INOPERATIVE IN ZONE TEMP CONTROLLER. REPLACED ZONE TEMP CONTROLLER IAW AMM 21-63-34. OPS CHECKED GOOD.May 31, 2013 · N457UA · Airbus A320232SDR UALA2013052903736Shutoff Valve · failedFAILURE OF AFT CARGO HEAT SHUTOFF VALVE OR TEMP CONTROL VALVE. STATUS MESSAGE 2112031, INACTIVE ER MODE MESSAGE 2112031, LATCHED ER MODE. R & R TEMP CONTROL SHUTOFF VALVE IAW MM, OPS CHECKED NORMAL.May 29, 2013 · N217UA · Boeing 777222SDR UALA2013052803695Sensor · faultyFLIGHT DECK TEMP SLOWLY RISES TO HOT WITH FLIGHT DECK TEMP SWITCH IN AUTO. OK IN OFF POSITION. SUP: USED OPTION 1 TURNED OFF TRIM SWITCH AND OFF LIGHT ON TRIM VALVE AT 00. REPLACED DUCT AIR TEMP SENSOR AND OPS CHECKED.May 28, 2013 · N550UA · Boeing 757222SDR UALA2013052303579Valve · faultedAFT CABIN TEMP EXCESSIVELY WARM WHILE INDICATOR READS 70 DEGREES. UNABLE TO TROUBLESHOOT DUE TO AFT CABIN TRIM VALVE TRIPPING CIRCUIT BREAKER. REPLACED AFT CABIN TRIM AIR VALVE IAW AMM. RESET CONTROLLER AND TESTED GOOD.May 22, 2013 · N586UA · Boeing 757222SDR UALA2013052203549Sensor · faultyTEMP HARD TO CONTROL ZONES D-E-F. STAYS TOO COLD. REPLACED RT PACK COMPRESSOR DISCHARGE TEMP SENSOR M21520 IAW MM, OPS CHECKED GOOD.May 22, 2013 · N204UA · Boeing 777222SDR UALA2013052203554Control System · inoperativeAFT GALLEY FLOOR TEMP CONTROL INOPERATIVE.May 22, 2013 · N210UA · Boeing 777222
Back to JASC 2160