SDR 2002UALA01557Warning Light · illuminatedAIRCRAFT LANDED UNDER AMBER ALERT WHEN BOTH LT AND RT DC FAIL LIGHTS ILLUMINATED IN FLIGHT. SUPPLEMENTAL DATA UPDATE RESET C-B GEN POWER CONT ON P6-5. OPS CHECKED NORMALSDR GLBA2002155Control Panel · failedLEFT DC GENERATOR FAILED ON TAKE OFF, REPLACED DC POWER PANEL.SDR UIEA200200035Control Unit · failedON CLIMBOUT, NR 3 AND NR 4 BUS TIES OPENED. SPLIT BUS SYSTEM OPEN. NR 3 GENERATOR WAS DISCONNECTED. NR 4 GENERATOR CHECKED GOOD VOLTS/ FREQ. NR 3 BUS LOST POWER AND COULD NOT REPOWER. DUMPED 17.0 KGS OF FUEL PRIOR TO LANDING. REMOVED AND REPLACED RIGHT SDR MALA020426Gcu · failedINFLIGHT ON 3238, THE RT GEN LIGHT CAME ON FOLLOWED QRH GEN RESET APPROXIMATLEY 5 MINUTES RT GEN LIGHT COMES ON, FOLLOWED QRH GEN WOULD NOT RESET. AIR RETURN TO DTW. MAINTENANCE REMOVED AND REPLACED RT DC GEN AND RT GCU.ALL CHECKS GOOD AT THIS TIME.SDR VNAA0207013Sensor · failedDURING CLIMBOUT, THE CREW RECEIVED A RIGHT HAND GENERATOR FAIL MESSAGE AND RETURNED TO DAY. MAINTENANCE INSPECTED AND REPLACED THE RIGHT HAND WING HALL EFFECT SENSOR IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 24-00-00. OPERATIONAL CHECKS WERE PERFORMED ANSDR MALA020395BatteryDURING EMERGENCY BATTERY CAPACITY CHECK, JC #243501 EMERGENCY BATTERY FAILED VOLTAGE/CAPACITY CHECK. MAINTENANCE REMOVED AND REPLACED EMERGENCY BATTERY IAW JC #243502. ALL CHECKS GOOD.SDR COMA0210026GeneratorFLIGHT 5067 #1 GENERATOR FAILED AFTER T/O.DEFERRED MAINT ON #1 GENERATOR PER MEL.SDR VNAA0206004Sensor · failedDURING CLIMBOUT, THE CREW RECEIVED A LEFT HAND DC GENERATOR FAIL CAS MESSAGE AND RETURNED TO PIT. MAINTENANCE INSPECTED AND REPLACED THE HALL EFFECT SENSOR IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 24-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCSDR HEEA079717Relay · intermittentRELAY CONTACTOR INTERMITTENTLY STICKS OPEN.SDR HEEA079716Relay · intermittentRELAY INTERMITTENTLY WHEN STARTER SWITCH ACTUATED NOTHING WOULD HAPPEN.SDR HEEA079368Relay · stuckCONTACTOR STUCK IN THE ENERGIZED POSITION ALLOWING STARTER TO BE POWERED ANYTIME AIRCRAFT POWER AND MASTER START WAS PLACED ON.SDR HEEA079367Relay · stuckRELAY CONTACTS SERVICING PINS 21, 22 AND 23 ARE STUCK IN THE ENERGIZED POSITION.SDR RAIA00205166Gcu · inoperative5533-PIA- RIGHT GENERATOR WILL NOT COME ON LINE. MAINTENANCE REMOVED AND REPLACED THE GENERATOR CONTROL UNIT.SDR MALA020297GcuDURING TAXI ON FLIGHT #3116, RH DC GEN WENT OFF LINE 2 TIMES DURING TAXI OUT TO RUNWAY, RESET BOTH TIMES AND FELL OFFLINE AGAIN ON RETURN TO GATE. MAINTENANCE REMOVED AND REPLACED RH GCU.ALL CHECKS GOOD.SDR LS1R088279Volt Regulator · malfunctionedGENERATOR WILL COME ON. REPLACED VOLT REGULATORSDR COMA0260323IdgFLIGHT 5268 DURING TAKE OFF ROLL RECEIVED AN IDG AND GENERATOR #1 MESSAGE, TAKE OFF WAS ABORTED AND RETURNED TO THE GATE.SERVICED THE #1 ENGINE IDG WITH OIL AND PERFORMED FUNCTIONAL CHECK, AIRCRAFT RETURNED TO SERVICE.SDR ASOA02211Gcu · failedFLT 4592 - DURING FLIGHT FROM ATL TO ISP, WITH HAVING THE AUXILIARY POWER UNIT PREVIOUSLY DEFERRED, THE RIGHT INTERGRATED DRIVE GENERATOR FAILED. AN EMERGENCY WAS DECLARED. AIRCRAFT DIVERTED AND LANDED SAFELY IN RDU. MAINTENANCE REMOVED AND REPLACED THE RIGSDR VNAA0204002Sensor · failedDURING FLIGHT 4053 PIT-YYZ THE LEFT DC GENERATOR FAILED. THE FLIGHT CREW PERFORMED THE PROCEDURES REQUIRED PER THE QUICK REFERENCE HANDBOOK AND THE FAILED GENERATOR WOULD NOT RESET. DUE TO THE WEATHER CONDITIONS THE FLIGHT CREW RETURNED TO PIT. A NORMAL LANSDR CA020401002Volt Regulator · failed(CAN) LEFT GENERATOR SYSTEM FAILED DURING CLIMB.SDR AALA20020388Gcu · failedMIA - FLT 68 - STARTED CYCLING ON AND OFF PRIOR TO OCEANIC ENTRY POINT AND CONTINUED FOR REMAINDER OF FLIGHT DIVERT TO MIA. REMOVED AND REPLACED LGCB AND RGBC. CHECKED GROUNDS AND GROUND WIRE BACK TO BPCU, CHECKS NORMAL. RAN ENGINES, STILL NO HELP. REMOVEDSDR C2XA02CL084Generator · contaminatedCLE FLIGHT# 3194 THE CREW REPORTED ALL 4 GENERATORS FELL OFF LINE AFTER GEAR RETRACTION.THE #4 GENERATOR DID COME BACK ONLINE. THE AIRCRAFT RETURNED TO CLEVELAND AND LANDED WITHOUT FURTHER INCIDENT.MAINTENANCE INSPECTED AND FOUND ALL FOUR GENERATORS TO BE CONTSDR AUS20020311Relay · faulty(AUS) REVERSE CURRENT RELAY (RCR) FAILED. BATTERY DISCHARGED ANDRESULTED IN A TOTAL POWER FAILURE.SDR RAIA00201030Sensor · inoperative5600-STL- #1 GENERATOR FAULTED. MAINTENANCE REMOVED AND REPLACED THE #1 HALL EFFECTS SENSOR. OPS CK OK.SDR AUS20020051Cable · worn(AUS) ALTERNATOR OUTPUT CABLE ARCING ON ALTERNATOR GROUND CABLE. CABLEHAD BEEN REMANUFACTURED FROM MIL-W-22759/16-4 MATERIAL.SDR QXEA0200074Generator · inoperativeSEA-#1 DC GENERATOR CAUTION LIGHT ILLUMINATED ON TAXI FOR TAKEOFF. RAN EMERGENCY CHECK LIST. REMOVED AND REPLACED #1 DC GENERATOR AND GCU. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.SDR VNAA0201015Sensor · failedDURING TAKEOFF, THE CREW RECEIVED A RIGHT HAND GENERATOR FAIL MESSAGE AND ABORTED TAKEOFF. THE AIRCRAFT WAS THEN FERRIED TO DAY WHERE MAINTENANCE INSPECTED AND REPLACED THE HALL EFFECT SENSOR IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 24-00-00. OPERATIONASDR AUS20020026Limiter · failed(AUS) DURING ENGINE EMERGENCY SHUTDOWN THE NR 2 ELECTRICAL SYSTEM BUS LIMITERS (225A) FAILED.SDR DLM88011912Battery · overheatedAT APU START ATTEMPT ON GATE A LOUD BANG WAS HEARD UNDER TH E GALLEY - FOUND A/C BATTERY SWELLED - PROBABLE EXPLOSIONSDR DL73K011865Circuit Breaker · defectiveON PUSHBACK ENG START NR 2 GEN ON LINE POWER DUMPED AND ALL FUEL PUMPS C/BS POPPED EXCEPT AFT NR 1 LOW PRESS LIGHTS AND NO PWR ON TR 2 & 3. CHECKED C/BS FOUND SEVERAL OPEN. RESET C/BS, OPN GOOD ON CLIMBOUT PASSING FL200 A/P DISCONNECTED SAME IND BEFORE FUEL SDR HEEA076991Control Unit · failedCAUSES GENERATOR TO KICK OFF LINE. PENDING VENDOR REPAIR.SDR LS1R076932Rccb · failedRCCB HAS NO OUTPUT.SDR PCAA0109113Generator · failedPWM-LGA FLIGHT#3738. CREW REPORTED WHILE AT 6,000 FT OVER HVN AIRPORT #2 ENGINE D.C. GENERATOR HOT LIGHT ILLUMINATED. #2 GENERATOR TURNED OFF, THEN NUMBER TWO ENGINE EXPERIENCED TORQUE AND PROP VIBRATION. THE NUMBER TWO ENGINE SHUT DOWN AND SECURED. FLIGHT DIVSDR DL764011535Relay · failedON CLIMBOUT, STBY BUS C/B POPPED. T/S FOUND BAD K106 RELAY NASI. REMOVED ACCESS PNL P6 C/B PANEL AND REMOVED K105 A/C STBY PW RELAY DPN 241202153. REMOVED AND REPLACED RELAY K105, OPS CKS NORMAL PER M/M 24-33-00-6-02. INSTALLED ACCESS PANEL.SDR DLM11011328Rccb · failedWHILE VERIFYING BOTH RCCBS B1-1649 AND B1-391 TO BE IN OPEN STATE REFERENCE MEL 28-22-06E L2 FWD AUX PUMP LOW PRESSURE CONDITION RCCB BI-1649 L2 PUMP WOULD NOT GO TO THE OPEN CONDITION, STUCK IN THE CLOSE CONDITION. REMOVED AND REPLACED RCCB B1-1649 PER M/M PESDR RAIA00108010Generator · failed7496-STL-RIGHT GENERATOR FELL OFF LINE DURING FLIGHT. MAINTENANCE INSPECTED AND REPLACED RIGHT STARTER GENERATOR.SDR RAIA00107035Gcu · failed5393-BWI-LEFT GENERATOR FELL OFF LINE, AMBER CAPTION ILLUMINATED DURING TAXI. MAINTENANCE INSPECTED AND REPLACED LEFT GENERATOR CONTROL UNIT.SDR FE62002F00000Converter · failedCONVERTER FAILED AND BEGAN TO MELT THE SIDEPANEL CARPET (WHICH WAS LYING ON TOP OF IT). AT THIS TIME THE CAUSE OF THE FAILURE IS UNCERTAIN.SDR 01FDEA00517Electrical Sys · malfunctionedDURING CLIMB GOT BUS R EMER OFF LEVEL 1 ALERT. DUMP 65,000 LBS FUEL. DOWN POWERED AND POWERED UP A/C, AC RETURN TO NORMAL. AS PRECAUTION REPLACED B1-138 R EMER A/C FEED RCCB3 PER MM 24-50-01-4 & EPCU RTS TEST PASSED PER MM 24-08-01-5.SDR DL777011029Battery · unserviceableAPU STATUS MSG APU BATTERY.APU CHARGER.ADDITIONAL APU BATTERY OVERHEAT.OVERHEAT WENT AWAY VOLTS APU BATTERY DOWN TO 19V STEADY 1 AMP DISCHARGE__T/S PER FIM R AND R APU BATTERY AND APU BATTERY CHARGER PER FIM STATUS MESSAGE CLEARED CHECKS OK SDR QXEA0101061Receptacle · damagedPDX- FOUND THE GROUND POWER RECEPTICAL DAMAGED. REPAIRED GOUND POWER RECEPTICAL IN ACCORDENCE WITH ENGINEERING AUTHORIZATION 6-53-16. OPERATIONAL CHECKS GOOD. REQUIRED INSPECTION COMPLIED WITH. AIRCRAFT RETURNED TO SERVICE.SDR RAIA00106009Generator · intermittent7324-STL-DC BUS WENT OFFLINE TWICE WHILE TAXIING. MAINTENANCE INSPECTED AND REPLACED LEFT STARTER GENERATOR.SDR MWEA010946Charger · defectiveON CLIMB OUT THROUGH FL 200 BATTERY CHARGER C.B. POPPED. -- REMOVED AND REPLACED BATTERY CHARGER. REMOVED AND REPLACED LEFT AND RIGHT SHIP BATTERIES.SDR 2001F00039Fuse · blownCREW NOTICED SMELL OF SMOKE, LEFT ALTERNATOR OUT LIGHT ILLUMINATED, FOUND LEFT ALTERNATOR FIELD FUSE BLOWN. MECHANIC REPLACED FUSE, INSPECTED ALTERNATOR WIRING, ALTERNATOR, VOLTAGE REGULATORS. NO DEFECTS NOTED. AIRCRAFT RETURNED TO SERVICE.SDR DLM88010743Transformer · damagedFWD E/E ABOVE TR L-2 HAS EVIDENCE OF HIGH HEAT TEMPERATURE DUE TO INSULATION BLANKET DAMAGE AND WORN FRAME AT STA 48 LBL 20. REPAIRED DAMAGE.SDR AUS20010395Filter · intermittent(AUS) LH NOISE FILTER INTERMITTENT IN OPERATION.SDR AUS20010392Generator · faulty(AUS) DC GENERATION SYSTEM FAULTY.SDR HEEA071964Contactor · failedCONTACTOR STUCK CLOSED.SDR GLBA2001057Wire · looseRETURN TO BLOCK - LEFT GENERATOR FELL OFF LINE. INSPECTED FOUND LOOSE WIRES ON DC PWR PANEL. OPS CHECKED GOOD.SDR MALA010210Power Supply · failedAIR RETURN DUE TO EMERGENCY POWER PROBLEM. LOST EMERGENCY POWER AFTER TAKEOFF. VOLTAGE WAS NORMAL. LOST STANDBY HORIZON AND COM 1. MAINTENANCE REMOVED AND REPLACED EMERGENCY POWER SUPPLY (P/N 501-1712-02) (S/N ON 1679) (S/N OFF 4585) PER SAAB AMM 24-35-10-SDR 01FDEA00083Transformer · failedOUTPUT DIFFERENCE BETWEEN TR 1 & 2 VS ESSENTIAL TR. REMOVED AND REPLACED NR 1 T/R PER IAW MM 24-53-000 & SYS OPS CK NORMAL.
Back to JASC 2430