SDR UALA2008123007050Charger · faultyAPU SHUTS DOWN WITH ELEC OR PNEUMATIC LOAD. REPLACED BATTERY CHARGER AS PER SERVICE TIP. CLEARED APU CONTROLLER OF ALL FAULTS. RAN ENG 3 TIMES TO PUT LOAD ON APU, AT MAX HAD 40 P.S.I. ALSO SERVICED APU OIL.SDR UALA2008122206953Battery · faultyBATTERY DISCHARGE LIGHT ILLUMINATED. REPLACED SHIP'S BATTERY.SDR UALA2008121806917Charger · failedMAIN BATTERY CHARGER EICAS MSG PRESENT. REPLACED MAIN BATTERY CHARGER UNIT. OP TESTED NORMAL.SDR UALA2008120806785Battery · faultyAPU BATTERY STATUS MESSAGE. REPLACED APU BATTERY.SDR UALA2008112606674Charger · inoperativeBATTERY CHARGER APU STATUS MSG. REPLACED APU CHARGER AND CHECK OK.SDR UALA2008112506671Battery · faultyEICAS MESSAGE, MAIN BATTERY CHARGER WILL NOT CLEAR. REPLACED MAIN BATTERY. OPS CHECKS GOOD. MESSAGE CLEARED.SDR UALA2008112406615Battery · faultySTATUS MSG BATTERY CHARGER MAIN. REPLACED MAIN BATTERY CHARGER AND BATTERY, NO HELP. SWAPPED APU BATTERY WITH MAIN BATTERY AND CHECKS OKAY.SDR UALA2008111806549Battery · reads lowEICAS MSG MAIN BATTERY CHARGER.SDR DL75E081479Circuit Breaker · poppedAPU DOOR STATUS MSG AFTER APU SHUTDOWN. RETURN TO GATE. FOUND APU BATT C/B POPPED. RESET SAME DOOR, OPN NOW NORMAL.SDR CA081110006Relay · failed(CAN) BATTERY WOULD NOT COME ONLINE ALTHOUGH FULL BATTERY VOLTAGE WAS OBSERVED AT BATTERY CONNECTIONS. BATTERY RELAY WAS REPLACED AND ACFT RETURNED TO SERVICE.SDR 2008UALA06302Battery · dischargedAPU WON`T START TRIED TWO TIMES. APU BATTERY ZERO VOLTS. REPLACED SHIP'S APU BATTERY. ALL START-RUN-CHARGE FUNCTIONS OKAY.SDR HALA2008102300826Battery · failedBATTERY CHARGER FAIL LIGHT ON CLIMBOUT. REPLACED ALL 3 BATTERIES PER AMM 24-34-01.SDR HALA2008102600829Battery · unknownETOPS SIGNIFICANT SYSTEM - UPON PUSHBACK BEFORE ENG START APU AUTO SHUT DOWN. REMOVED & REPLACED APU BATTERY PER AMM24-31-04. OPS CHECK OK. PERFORMED APU ECU BITE CK. NO FAULTS NOTED. OK FOR SERVICE. FOUND NO APU ELECTRICAL. REPLACED APU GCU PER AMM24-2SDR 2008UALA06296Battery · faultyAPU BATTERY AND APU CHARGER STATUS MESSAGE. REPLACED APU BATTERY & CHARGER. OP CHECKS NORMAL.SDR 2008UALA06089Battery · faultySTATUS MESSAGE "MAIN BATTERY". REPLACED & OP CHECKED MAIN BATTERY. MESSAGE CLEARED. BATTERY INDICATIONS NORMAL.
SDR 2008UALA06047Battery · faultySTATUS MSG APU BATTERY. REPLACED BATTERY, NO HELP. RELOADED ELMS P310 ELECTRONIC UNIT OPC AND OPS SWICH PER MM24-09-00. THIS CLEARED STORED FAULTS. AFTER RELOAD ACCPLISHED TEST OF APU BATTERY & CHAGER TO ENSURE PROPER OPS. NO MESSAGES FOUND ON EICAS. ACCOMPLISDR 2008UALA06046Charger · malfunctionedSTATUS MSG BATTERY CHARGER APU. REPLACED-CHARGER, NO HELP. RELOADED ELMS P310 ELECTRONIC UNIT OPC AND OPS SW PER MM24-09-00 PG201 THIS CLEARED THE FAULTS. AFTER RELOAD ACCOMPLISHED TEST OF APU BATTERY & CHARGER. RAN APU FOR HALF HOUR AND THE APU BAT CHARGER SDR USAASB08093Charger · failedDURING CRUISE, EN ROUTE FROM PHL TO PBI, CREW RECEIVED BOTH IRS DC FAIL LIGHTS. CREW SUSPECTS BATTERY CHARGER INOPERATIVE. BATTERY WAS AT 18 VOLTS WHEN DISPATCH WAS CONTACTED. BATTERY WAS AT 17 VOLTS WHEN THE SECOND MESSAGE WAS SENT THAT THE CIRCUIT BREAKERSDR 2008UALA06020Battery · inoperativeTHE "BAT CHARGE APU AND APU BATTERY" STATUS DISPLAYED ON LOWER EICAS. REPLACED CHARGER, NO HELP. REPLACED BATTERY & MESSAGE CLEARED.SDR CA081002004Battery · overheated(CAN) PASSENGERS WERE ON THE ACFT, ACFT WAS ON EXTERNAL GROUND POWER AT THE TIME. WHEN THE PILOTS WENT TO START THE APU, THEY NOTICED THE START WAS NOT NORMAL, AND THE APU ALSO DID NOT START. APU OVERSPEED CAUTION LIGHT ILLUMINATED. CAPTAIN WENT TO THE E&E SDR 2008UALA05935Relay · failedELEC STANDBY SYS ELECTRICAL DC-STANDBY POWER SYSTEM FAILED THE SYSTEM SELF-CHECK. STATUS MSG-2413035 ACTIVE DC MODE MSG-2413035 ACTIVE DC MODE. REPLACED MAIN BATTERY RELAY. CHECKS OKAY.
SDR AALA200802402Charger · faultedMAN INFLIGHT T54/21SEP. PRIOR TO FLAP EXTENSION LEADING EDGE ASYMMETRY AND EICAS MSG ILLUMINATED. LANDED WITHOUT INCIDENT MAN WITH 20 DEGREE FLAPS NO SLATS. CLEANED NR 10 SLAT SENSOR AND REPLACED MAIN BATTERY CHARGER. SYSTEM GROUND CHECKED NORMAL OPS.SDR 2008UALA05782Charger · faultyMAIN BATTERY CHARGER EICAS MESSAGE. REPLACED MAIN BATTERY CHARGER.SDR 2008UALA05685Battery · faultyBATTERY CHARGER STATUS MESSAGE WILL NOT ERASE. REPLACED BATTERY. OPS GOOD. NO FAULTS.SDR 2008UALA05628Charger · inoperativeSTATUS MESSAGE APU. APU BATTERY AND CHARGER INOP, NEEDS REPLACEMENT. CHARGER NOT CHARGING. FOUND APU BATTERY & CHARGER INOP. REPLACED APU BATTERY & APU BATTERY CHARGER. OPS CHECK NORMAL.SDR 2008UALA05639Charger · inoperativeMAIN BATTERY CHARGER STATUS MESSAGE. FOUND FAULTY BATTERY/CHARGER. REPLACED BATTERY & CHARGER. OP CHECKS OKAY FOR SERVICE.
SDR 2008UALA05545Battery · smokeSMOKE DETECTED IN AFT GALLEY BY OUTBD FA GATE. MECH IN COCKPIT TURNED OFF PWR TO AC. FOUND APU BATTERY SMOLDERED. REPLACED APU BATTERY & APU BATTERY CHARGER. ALL CHKS NORMAL.SDR CA080902002Battery · thermal runaway(CAN) DURING DAILY INSP OF ACFT, GPU USED. ACFT KEY TURNED (ON) TO CHARGE BATTERIES. APPROX. 2.5 HRS LATER, VENTING OF BATTERY NOTICED FROM ACFT. SMELL OF BURNING PLASTIC. GPU DISCONNECTED, KEY (OFF). ACFT MOVED OUTSIDE. AIRPORT FIRE DEPT. REMOVED NR 1 BATTERSDR FDEA200808253580Rectifier · inoperativeEMERGENCY PWR ON ALERT INFLIGHT. WHEN SELECTED OFF, DC3 DID NOT APPEAR POWERED. EMERGENCY PWR ARM AND ALERT STAYED ON. ADG DEPLOYED. ON SHORT FINAL DC3 UNPOWERED WITH LOSS OF ADG POWER RESULTING IN LOSS OF ASSOCIATED SYSTEMS. FLIGHT DIVERTED DFW AND LANDSDR 2008UALA05481Charger · faultySTATUS MESSAGE MAIN BATTERY CHARGER ON. FOUND MAIN BATTERY CHARGER FAILING. REPLACED MAIN SHIPS BATTERY CHARGER.SDR 08FDEA03580Rectifier · malfunctionedEMERGENCY PWR ON ALERT INFLIGHT. WHEN SELECTED OFF, DC3 DID NOT APPEAR POWERED. EMERGENCY PWR ARM AND ALERT STAYED ON. ADG DEPLOYED. ON SHORT FINAL DC3 UNPOWERED WITH LOSS OF ADG POWER RESULTING IN LOSS OF ASSOCIATED SYSTEMS. FLIGHT DIVERTED DFW AND LANSDR CA080815002Battery · overheated(CAN) DURING CLIMB OUT FROM YWK, THE CREW RECEIVED A "MAIN BAT HOT" RED WARNING MSG ASSOCIATED WITH A HIGH TEMPERATURE ON THE BATTERY TEMPERATURE MONITOR. THE ACFT RETURNED AND LANDED WITHOUT FURTHER INCIDENT. MX CONFIRMED THE BATTERY SUFFERED FROM A THERMAL RSDR 2008UALA04251Charger · faultyBATTERY CHARGER APU STATUS MSG. *S/D* FOUND FAULTY BATTERY CHARGER. REPLACED BATTERY CHARGER PER MM 24 -31-06, OP CHECK GOOD. AC OK FOR SERVICE.SDR CA080822005Battery · discharged(CAN) DURING ACFT START, THE BATTERY WAS FOUND WITH NO CHARGE, BATTERY REPLACED.SDR CA080728001Battery · overtemp(CAN) DURING CRUISE THE CREW RECEIVED A MAIN BATTERY HOT WARNING MESSAGE. THE HIGH TEMP WAS CONFIRMED ON THE BATTERY TEMP MONITOR. THE CREW DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. THE BATTERY TEMPERATURE WAS EVALUATED AT 180°C. THE BATTERY COMPARTMSDR 2008UALA03926Fuse · inoperativeAIRCRAFT BATTERY IS INOP. AIRCRAFT WILL NOT POWER UP. INSTALLED NEW BATTERY. STILL DID NOT POWER UP. REPLACED INTERLOCK FUSES IN P34 PANEL. CHECKS GOOD.
SDR C2X2008F00008Battery · overtempLCH - FLIGHT 2830, THE CREW REPORTED A BATTERY 2 OVERTEMP WARNING ON EICAS. THE AIRCRAFT DIVERTED TO LCH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE NUMBER TWO BATTERY, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APSDR KCS2008F00004Battery · fumesSMOKE AND FUMES IN COCKPIT. FOUND SHIP’S MAIN BATTERY EMITTING FUMES. REMOVE AND REPLACE MAIN BATTERY AND CHARGER WITH APU BATTERY AND CHARGER PER GMM 3-5-8. APU BATTERY P/N 40176-7, S/N 076021 INSTALLED IN MAIN POSITION PER AMM 24-31-01. APU BATTERY CHARGSDR SWAA083923Charger · faultyAIR TURNBACK, ACRID ODOR REPORTED IN CABIN AND FLIGHT DECK. REMOVED AND REPLACED BATTERY CHARGER PER MM.SDR FDEA200807132873Battery · dischargedAFTER LEVEL OFF AT FL390, APPROX 20 MIN AFTER TAKEOFF GOT LVL 1 BATT LOW ALERT. DIVERTED TO KLAS BATTERY SHOWED AMBER BOXED. REMOVED AND REPLACED ACFT BATTERIES IAW AMM 24-34-02-4. PERF DC TIE BUSS OPS CHK. REMOVED AND REPLACED BATTERY CHARGER. REMOVED ANSDR 08FDEA02873Battery · unknownAFTER LEVEL OFF AT FL390, APPROX 20 MIN AFTER T/O GOT LVL 1 BATT LOW ALERT. DIVERTED TO KLAS BATT SHOWED AMBER BOXED 8 OR 7. REMOVED AND REPLACED A/C BATTERIES IAW AMM 24-34-02-4. PERF DC TIE BUSS OPS CHECK. REMOVED AND REPLACED BATTERY CHARGER. REMOVED ASDR 2008UALA03462Battery · failedAIRCRAFT WILL NOT ACCEPT POWER. MAIN BATTERY FAILURE. REPLACED MAIN AIRCRAFT BATTERY, CHECKS GOOD.SDR ASAA0853022Charger · malfunctionedAUX BATTERY SHOWS A 2 AMP CHARGE AND HAS NOT DECREASED TO ZERO. DC VOLTS SHOWS 27 CKD AUX BATT AND AUX BATT CHGR REF 24 31 31, OPS CKS OK WITHIN.SDR 2008UALA03111Battery · faultyMAIN BATTERY CHARGER STATUS MESSAGE WOULD NOT ERASE. *S/D* SUSPECT FAULTY BATTERY. REPLACED MAIN BATTERY. OPS CHECKS GOOD. REF: MM 24-31-02. AC OK FOR SERVICE.SDR 2008UALA02993Battery · faultyTHE 'MAIN BAT CHGR' EICAS MSG DISPLAYED. CYCLED STBY POWER THROUGH OFF-BATT, NO HELP. FOUND BATTERY TO BE FAULTY. REPLACED BATTERY PER MM 24-31-01, OPS CHECKED OK. AC OK FOR SERVICE.SDR 2008UALA02960Battery · dischargedAPU WILL NOT START. SUSPECT FAULTY BATTERY. REPLACED BATTERY, OP CHECKED GOOD. AC OK FOR SERVICE.SDR CA080523006Battery · leaking(CAN) DURING DI FOUND THE BATTERY LEAKING, REPLACED WITH A NEW ONE.SDR HNAA0800177Warning System · faultyMAIN BATTERY HOT WARNING LIGHT ILLUMINATED DURING TAXI, BATTERY TEMP MONITOR PANEL READS NORMAL TEMP. INSPECTED WIRES AT MAIN BATTERY, NO DEFECTS NOTED. REMOVED AND REPLACED MAIN BATTERY GROUND RAN A/C, NO DEFECTS NOTED IAW 24-32-00.SDR DLM88080762Charger · failedBATTERY CHARGER FAILED - UPON SHOP EXAMINATION, FOUND C9 DAMAGED BY HEAT FROM R6. NOTE: THIS CHARGER HAS HAD SB 203BC102-24-06 COMPLIED WITH (MOVED R6 TO BASE OF C9 ASSEMBLY). THE DAMAGE TO C9 APPEARED TO BE ALMOST TO THE POINT OF CAUSING C9 TO IGNITE AND CSDR 2008UALA02700Charger · faultyAPU BATTERY CHARGE MESSAGE DISPLAYED ON EICAS. SUSPECT FAULTY BATTERY CHARGER. REPLACED BATTERY CHARGER PER MM 24-31-06. AC OK FOR SERVICE.