SDR 2008UALA02625Relay · faultyFOUND MSG 24-13783, ALSO APU BATTERY WILL NOT DROP BELOW 31 VOLT. REPLACED RELAY. MSG CLEARED. AC OK FOR SERVICE.SDR 2008UALA02302Battery · weakAPU ARRIVED AT GATE WITH AN APU WEAK BATTERY MESSAGE AND APU CHARGER MESSAGE. BATTERY VOLTS AT 24 VDC, CHARGER NO MORE THAN 1 AMP CHARGE. FOUND FAULTY CHARGER. REPLACED APU BATTERY CHARGER AND APU BATTERY, REF MM 24-31-06 AND MM 24-31-05. OPS TEST OK.AC OK SDR ASAA0852823Circuit Breaker · openFOUND BATTERY STANDBY POSITION INDICATOR CIRCUIT BREAKER OPEN. RESET STANDBY POWER CONTROL UNIT CIRCUIT BREAKER.SDR 2008UALA02208Battery · faultyMAIN BATTERY CHARGER STATUS MSG. SUSPECT FAULTY BATTERY. REPLACED MAIN BATTERY OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02203Charger · inoperativeBATTERY CHARGER MESSAGE ON EICAS. FOUND FAULTY BATTERY CHARGER AND BATTERY. REPLACED BATTERY AND BATTERY CHARGER. AC OK FOR SERVICE.SDR HALA0800454Battery · faultyETOPS SIGNIFICANT SYSTEM , EICAS MSG MAIN BATTERY CHARGER DISP BATTERY DISCHARGE LT DID NOT ILLUM. REMOVED AND REPLACED MAIN BATTERY PER AMM 24-31-01, OPS AND SECURITY CHECK GOOD.
SDR ARWA20080303Battery · dischargedON PRE-FLIGHT, FOUND BATTERY VOLTS READS ZERO. REMOVED 02 BATTERY IN ACCORDANCE WITH A/M/M 24-34-01. CHARGED 02 BATTERY IN ACCORDANCE WITH DC-10-A/M/M 24-34-01; REINSTALLED 02 BATTERY IN ACCORDANCE WITH 24-34-01. TEST CHECK OK IN ACCORDANCE WITH A/M/M 24-34SDR AMTA200800201Charger · unserviceableEICAS MESSAGE MAIN BATTERY CHARGER. REMOVED AND REPLACED MAIN BATTERY CHARGER IAW MM 24-31-02-4. TESTED GOOD. (K)SDR HALA0800306Battery · hotETOPS SIGNIFICANT SYSTEM, STATUS MSG "MAIN BATT CHGR" BATT VOLTAGE 26VDC, BATTERY HOT, CHARGER GREEN LT ON, FOUND DURING ETOPS 1 CHECK. T/S PER FIM 24-31-00 FIG 103A, REMOVED AND REPLACED MAIN A/C BATTERY PER AMM 24-31-01-004-001/404-006. VOLTAGE CHECK AND CSDR F3LA200800055Limiter · inoperativeDURING TAKEOFF, THE FLIGHT CREW REPORTED AN ELAC BCL2 FAULT ON THE ECAM. THE FLIGHT CREW PERFORMED AN AIR TURN BACK AND AN UNEVENTFUL LANDING WAS ACCOMPLISHED. MAINTENANCE REMOVED AND REPLACED THE NUMBER 2 BATTERY CHARGE LIMITER IN ACCORDANCE WITH THE REQUIRSDR 2008UALA00665Charger · faultyBATTERY CHARGER MAIN STATUS MSG DISPLAYED. SUSPECT FAULTY BATTERY CHARGER. REPLACED MAIN BATTERY CHARGER PER MM-24-31-02 MAIN BATTERY PER MM24-31-01. OPS CHECKED NORMAL. AC OK FOR SERVICE.SDR AMWA89766BCBattery · dischargedAFTER TAKEOFF, BATTERY CHARGE ANNUNCIATOR ILLUMINATED. MAINT REPLACED BATTERY AND CLEARED DISCREPANCY.SDR 2008UALA00387Battery · dischargedA/C LOST POWER AT GATE PRIOR TO DEPARTURE. ACFT WILL NOT POWER UP. SUSPECT BATTERY VOLTAGE LOW. REPLACE MAIN AND APU BATTERYS. REPLACED APU BATTERY CHARGER. OPERATION NORMAL. REPLACED MAIN BATTERY CHARGER. GRD CHECKED NORMAL. ACFT OK FOR SERVICE.
SDR 2008UALA00368Battery · faultyMAIN BATTERY CHARGER EICAS MESSAGE WILL NOT CLEAR. REPLACED MAIN BATTERY AND CHARGER PER MM24-31-01 AND 24-31-02. MESSAGE CLEARED. AIRCRAFT RETURNED TO SERVICE.SDR AMWA89563BCPcb · malfunctionedBATTERY CHARGE ANNUNCIATOR ILLUMINATED IN FLIGHT. MAINT REPLACED PCB A130 AND CLEARED DISCREPANCY.SDR AMWA89557BCBattery · dischargedBATTERY CHARGE ANNUNCIATOR LIGHT ILLUMINATED IN FLIGHT. MAINT REPLACED BATTERY AND CLEARED DISCREPANCY.SDR C2XA08IA016Panel · defectiveIAH - FLIGHT 2785, THE CREW REPORTED RECEIVING AN "EMERGENCY LIGHTS NOT ARMED" MESSAGE IN FLIGHT. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE REMOVED AND REPLACED THE MAIN BATTERY ELECTRICAL PANEL, OPERATIONALLY CHECKED WITH NO DEFECTS, AND SDR AMWA89439BCBattery · dischargedBATTERY CHARGE ANNUNCIATOR ILLUMINATED IN FLIGHT. MAINTENANCE FOUND EACH CELL TO BE LOW VOLTAGE, CLEANED POSITIVE BATTERY TERMINAL CORROSION, RETORQUED CELL LINKS, AND CHARGED BATTERY THEN CLEARED DISCREPANCY.SDR AMWA89426BCBattery · dischargedBATTERY CHARGE ILLUMINATED IN FLIGHT. MAINTENANCE REPLACED BATTERY AND CLEARED DISCREPANCY.SDR HALA0800006Battery · dischargedETOPS SIGNIFICANT SYSTEM, APU FAILED TO START. FAULT LT ILLUM AND EICAS MSG APU FAULT DISPLAYED TIME OAT -32 DEGREES FL 390 1S-3RD START ATTEMPTS UNSUCCESSFUL. ACCOMPLISHED FIM 49-11-00 FIG 103/106A, REPLACED APU BATTERY PER AMM 24-31-04 GRD OPS CHK OK.SDR COMA0860009Battery · faultyFLIGHT 5300 - RECEIVED INTERMITTENT BATTERY BUSS CAUTION MESSAGE. DIVERTED TO MCO, LANDED WITHOUT INCIDENT. REPLACED MAIN BATTERY. NO FURTHER DEFECTS.SDR ASAA0752443Charger · malfunctionedWHILE TAXIING OVERHEAD "ELEC" LIGHT ILLUMINATED. RAN FIM 24 31 TASK 801. ELECTRICAL MODULE SHOWED "BATTERY CHARGER INOP". CLEARED FAULT RERAN FIM TASK. NO FAULTS SHOWING. ALSO VISUALLY CHECKED BATTERY CHARGER INDICATION LIGHTS IAW FIM 24 31 TASK 824. BOTSDR AMWA89107BCBattery · dischargedBATTERY CHARGE ANNUNCIATOR ILLUMINATED IN FLIGHT. MAINTENANCE REPLACED BATTERY AND CLEARED DISCREPANCY.SDR AMWA18345BCBattery · dischargedBATTERY CHARGE ANNUNCIATOR ILLUMINATED IN FLIGHT. MAINTENANCE REPLACED BATTERY AND CLEARED DISCREPANCY.SDR AMWA88960BCBattery · dischargedBATTERY CHARGE ANNUNCIATOR ILLUMINATED IN FLIGHT. MAINTENANCE REPLACED BATTERY AND CLEARED DISCREPANCY.SDR AMWA88820BCBattery · dischargedDURING FLIGHT THE BATTERY CHARGE ANNUNCIATOR ILLUMINATED. MAINTENANCE CHARGED BATTERY AND CLEARED DISCREPANCY.SDR AMWA88803BCBattery · dischargedBATTERY CHARGE ANNUNCIATOR ILLUMINATED FOR A SHORT TIME. MAINTENANCE REPLACED BATTERY AND CLEARED DISCREPANCY.SDR CA071128012Battery · shorted(CAN) AC SUFFERED ALMOST AN ENTIRE ELECTRICAL FAILURE DURING CLIMBOUT. AFTER SUBSEQUENT UNSCHEDULED LANDING, IT WAS DETERMINED THAT THE BATTERY HAD ACQUIRED AN INTERNAL SHORT, WHICH DEPLETED THE GENERATOR OUTPUT AND CAUSED THE AVIONICS TO MALFUNCTION. BATTERYSDR AMWA88594BCBattery · dischargedDURING FLIGHT, THE BATTERY CHARGE ANNUNCIATOR ILLUMINATED. MAINTENANCE REPLACED BATTERY AND CLEARED DISCREPANCY.SDR AMWA88587BCBattery · dischargedBATTERY CHARGE ANNUNCIATOR ILLUMINATED 3 TIMES. MAINTENANCE REPLACED BATTERY AND CLEARED DISCREPANCY.SDR AFASVRA3181Battery · overheatedAIRCRAFT 12 VOLT BATTERY OVERHEATED CAUSING: ELECTROLYTE BOILING OVER, CORRODING OF ALUMINUM BATTERY BOX, LANDING LIGHT PLASTIC SWITCH MELTING, LANDING LIGHT PLASTIC CONNECTOR IN COWLING MELTING, LANDING LIGHT INOP AND ALTERNATOR FAILURE WITHOUT THE LANDING LISDR 2007UALA04637Charger · faultyAFTER BLOCKING OUT -MAIN BATTERY DISCHARGE- ADVISORY MESSAGE DISPLAY, WITH A -12 AMP DISCHARGE ON MAIN BATTERY. CYCLED STBY POWER SW ON OVERHEAD AND DISCHARGE DECREASED TO -2 AMP WITH 24 VDC ON MAIN BATTERY. REPLACED MAIN BATTERY CHARGER, OP CHECKED OK FOR SSDR AMWA88513BCBattery · dischargedAFTER TAKEOFF, HAD BRIEF BATTERY CHARGE ANNUNCIATOR ILLUMINATION. THEN, AFTER NEXT TAKEOFF ANNUNCIATOR REMAINED ILLUMINATED AND WAS ACCOMPANIED BY BATTERY AMMETER AND BOTH GENERATOR LOAD METERS CYCLING. AMMETER CYCLED FROM 0 TO 30A AND LOAD METERS CYCLED FROM SDR AMWA88479BCCircuit Board · inoperativeDURING FLIGHT BATTERY CHARGE ANNUNCIATOR ILLUMINATED. MAINTENANCE REPLACED A-130 PC BOARD AND CLEARED DISCREPANCY.SDR AMWA88451BCBattery · failedAFTER TAKEOFF THE BATTERY CHARGE ANNUNCIATOR ILLUMINATED. AIRCRAFT RETURNED TO FIELD AND BATTERY WAS REPLACED AND DISCREPANCY CLEARED.SDR AMWA88437BCBattery · failedDURING FLIGHT THE BATTERY CHARGE ANNUNCIATOR ILLUMINATED THEN WENT OUT. MAINTENANCE REPLACED BATTERY AND CLEARED DISCREPANCY.SDR AMWA88439BCBattery · failedDURING FLIGHT THE BATTERY CHARGE ANNUNCIATOR ILLUMINATED THEN WENT OUT. MAINTENANCE REMOVED AND REPLACED BATTERY AND CLEARED DISCREPANCY.SDR CA071109001Battery · failed(CAN) DURING ENGINE NR 2 START UP, THE NR STALLED AT 20 NR AND THE ITT INDICATOR REACHED 800 DEGREES CELSIUS. THE ENGINE START WAS ABORTED FOLLOWING BY A LOUD BANG FROM THE NOSE COMPARTMENT. MAINTENANCE WAS CALLED IN AND THEY FOUND THE MAIN BATTERY TOP COVER SDR AMWA88382BCBattery · malfunctionedBATTERY CHARGE ANNUNCIATOR ILLUMINATED IN FLIGHT MULTIPLE TIMES. BATTERY WAS REPLACED BY MAINTENANCE AND DISCREPANCY CLEARED.SDR AMWA88376BCBattery · malfunctionedBATTERY CHARGE ANNUNCIATOR ILLUMINATED TWICE IN FLIGHT. 1ST TIME IN CLIMB A FEW SECONDS AFTER GEAR RETRACTION AND CONTINUING THROUGH FL100 ALL AT ~10A. 2ND TIME WAS A FEW MINUTES INTO CRUISE FOR 2-3 MINUTES AT APPROXIMATELY 8A. MAINTENANCE REPLACED BATTERY ANDSDR AMWA88325BCBattery · malfunctionedBATTERY CHARGE ANNUNCIATOR ILLUMINATED MULTIPLE TIMES DURING FLIGHT. MAINTENANCE REPLACED BATTERY AND CLEARED DISCREPANCY. THIS TYPE DISCREPANCY IS CONSIDERED A DISTRACTION TO THE CREW AND A NUISANCE ITEM.SDR 2007UALA04411Battery · dischargedMAIN BATTERY DEAD. REPLACED MAIN BATTERY PER MM 24-31-01, OPS OK. ACFT OK FOR SERVICE.
SDR 2007FA0000933Shunt · blownCOMPLETE ELECTRICAL FAILURE. WHEN BATTERY MASTER SWITCH WAS TURNED ON, NO POWER REACHED MAIN BUSS. FOUND BATTERY AMMETER SHUNT BURNED THROUGH. BATTERY AMMETER SHUNT INSTALLED WAS 30 AMP VALUE. (P/N MS91586-1) BATTERY AMMETER SHUNT SHOULD BE 100 AMP VALUE. SDR AMWA88093BCBattery · dischargedBATTERY CHARGE ANNUNCIATOR ILLUMINATED AFTER TAKEOFF. BATTERY WAS REPLACED AND DISCREPANCY WAS CLEARED. THIS TYPE ANNUNCIATOR DISCREPANCY IS CONSIDERED A NUISANCE ITEM AND DISTRACTION TO CREW.SDR AMWA88091BCBattery · dischargedBATTERY CHARGE ANNUNCIATOR ILLUMINATED IN FLIGHT. BATTERY REPLACED BY MAINTENANCE, DISCREPANCY CLEARED. THIS TYPE ANNUNCIATOR DISCREPANCY IS CONSIDERED A NUISANCE ITEM AND DISTRACTION TO CREW.SDR AMWA87942BCBattery · dischargedBATTERY CHARGE ANNUNCIATOR ILLUMINATED IN FLIGHT. BATTERY WAS REPLACED AND DISCREPANCY WAS CLEARED. THIS BATTERY CHARGE ANNUNCIATOR WRITEUP IS CONSIDERED A NUISANCE INDICATION AND IS DISTRACTING TO THE FLIGHTCREW.SDR F3LA200700277Battery · dischargedFLIGHT CREW REPORTED EMERGENCY LIGHTS "ON" CAUSING LOW VOLTAGE ON AIRCRAFT BATTERY. REMOVED AND REPLACED NR 1 MAIN BATTERY IAW AMM 24-38-37 PB401. OPS CHECKED GOOD.SDR AALA20071878Charger · inoperativeLBB INFLIGHT T1873/06OCT DFW TO ABQ - DURING CRUISE BATTERY CHARGER LIGHT ILLUMINATED. LANDED LBB WITHOUT INCIDENT. REPLACED BATTERY CHARGER, SHIP BATTERIES AND BATTERY CHARGER TRANSFER RELAY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR USAABB07078Charger · failedFLT 569 PHX - MCO CREW RECEIVED MAIN BATTERY CHARGER STATUS MESSAGE ALONG WITH A BURNING ODOR IN COCKPIT. RETURNED TO PHX. MAINTENANCE REPLACED MAIN BATTERY CHARGER.SDR AC2A117606Battery · dischargedBATTERY LOW VOLTAGE. REMOVED AND REPLACED BATTERY.
Back to JASC 2432