SDR AMWA87659BCBattery · dischargedBATTERY CHARGE ANNUNCIATOR ILLUMINATED DURING FLIGHT. AIRCRAFT CONTINUED TO DESTINATION WITHOUT INCIDENT. BATTERY WAS REPLACED. THIS TYPE ANNNUNCIATOR WRITEUP IS CONSIDERED A NUISANCE AND DISTRACTION TO THE CREW.Sep 25, 2007 · N166YV · Beech 1900DSDR AMWA87546Battery · corrodedAFTER ARRIVING, THE CREW CALLED MAINT CONTROL TO WRITEUP THE BATTERY CHARGE ANNUNCIATOR ILLUMINATED IN FLT. THIS BATTERY CHARGE ANNUNCIATOR WRITEUP IS A NUISANCE ALARM AND IS DISTRACTING TO THE FLIGHTCREW. MAINTENANCE CLEANED THE BATTERY SHUNT, OPS NORMAL.Sep 19, 2007 · N244YV · Beech 1900DSDR 2007UALA03683Warning Message · activatedBATTERY CHARGER APU; STATUS MESSAGE RECEIVED. 10-5-07 REPLACED APU BATTERY CHARGER, BATTERY, AND CARD M24406A4 IN PANEL P310, OP CHECKS OK.Sep 11, 2007 · N772UA · Boeing 777222SDR QXEA200701400Battery · malfunctionedLAX FLIGHT NR 2468: ON TAXI OUT, NR 1 TRU SHOWED NO LOAD. MAIN BATTERY SHOWED BETWEEN A CHARGE OF -18 TO A LOAD OF +15 WITHIN A 15 SECOND SPAN AND CONTINUED TO CYCLE. NO TRU CAUTION LIGHT. PULLED TRU C/B PER MTC AND RESET. NR 1 TRU LOAD SHOWED .01 THEN 0. Sep 8, 2007 · N401QX · Bombdr DHC8402SDR 2007UALA03625Charger · faultyAPU BATTERY DOES NOT SHOW ANY CHARGING AFTER STANDBY POWER CHECK. 10-11-07 REPLACED BATTERY CHARGER. SYSTEM SHOWS CHARGING ABILITY. AIRCRAFT OK FOR SERVICE.Sep 7, 2007 · N193UA · Boeing 747422SDR 2007UALA03597Battery · faultyMAIN BATTERY CHARGER DISPLAYED ON STATUS PAGE. UNABLE TO CLEAR. FOUND BATTERY HOT TO THE TOUCH. REPLACED MAIN SHIPS BATTERY.Sep 5, 2007 · N574UA · Boeing 757222SDR AMTA200700413Charger · malfunctionedEICAS MSG APU BAT CHARGER DISPLAYED WITH APU DISCH LGT EXTING. T/S IAW FIN 24-31-00, BLOCKS 1 AND 2, SYSTEM IS OK. (K)Sep 3, 2007 · N518AT · Boeing 75723NSDR SWAA074242Charger · overheatedDIVERSION / DECLARED EMERGENCY. CLIMBING OUT OF SAN AT 23000, CREW SMELLED AN ACRID / ELECTRICAL ODOR. TURNED RECIRC AND GASPER FAN OFF, ODOR DISSIPATED. FOUND AIRCRAFT BATTERY CHARGER OVERHEATING, REMOVED AND REPLACED BATTERY CHARGER AND BATTERY PER MM.Aug 28, 2007 · N288WN · Boeing 7377H4SDR C2XA07ON019Battery · overheatedFLIGHT 7770 - OAK TO LAX - FLIGHT CREW DECLARED EMERGENCY IN FLIGHT DUE TO BATTERY NR 2 OVERHEAT TO 80 DEGREES F. CREW LANDED IN LAX WITHOUT INCIDENT. MX PERSONNEL REMOVED AND REPLACED NR 2 MAIN BATTERY OPERATIONALLY CHECKED WITH NO DEFECTS AND A/C WAS APPROAug 28, 2007 · N12569 · Emb EMB145XRSDR C2XA07IA194Battery · overtempTUL - FLIGHT 2403, THE CREW REPORTED A BATTERY 2 OVERTEMP INDICATION ON EICAS. THE CREW DEACTIVATED THE NUMBER TWO BATTERY, AND THE AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE NUMBER TWO MAIN BATTERY, OPERATIONALLY CHECKED WITH NO Aug 27, 2007 · N16112 · Emb EMB145XRSDR 2007UALA03345Battery · faultyMAIN BATTERY + BATTERY CHARGER MAIN STATUS MSG WITH MAIN BATTERY DISCHARGE EICAS. REPLACED MAIN BATTERY AND MAIN BATTERY CHARGER PER MM24-31-02 AND 24-31-01. BOTH CHECK OK FOR SERVICE.Aug 23, 2007 · N780UA · Boeing 777222SDR UPS07650480Battery · dischargedINSPECTION TYPE:ETOP BTB - APU AIR INOP. REMOVED AND REPLACED APU BATTERY PER MM 24-31-04-4.Aug 22, 2007 · N334UP · Boeing 76734AFSDR 2007UALA03319Warning System · activatedBATTERY CHARGER AND APU BATTERY MESSAGES DISPLACED ON STATUS PAGE. REPLACED BATTERY AND CHARGER PER MM24-31-05 & MM24-31-06. OP CHECKS READY FOR SERVICE.Aug 22, 2007 · N793UA · Boeing 777222SDR 2007UALA03313Warning System · activatedTAXI INBOUND APU BATTERY STATUS MESSAGE. REPLACED APU BATTERY AND APU BATTERY CHARGER, CHARGING SYSTEM GROUND OPS NORMALLY.Aug 21, 2007 · N117UA · Boeing 747422SDR AMWA86756BCBattery · false activationBATTERY CHARGE ANNUNCIATOR ILLUMINATED WHEN GEAR WAS EXTENDED AND THEN EXTINGUISHED. AC LANDED WITH NO FURTHER INCIDENT. THIS BATTERY CHARGE ANNUNCIATOR WRITEUP IS A NUISANCE WRITEUP AND DISTRACTION TO THE CREW. COULD NOT DUPLICATE ON GROUND, OPS CHECKS NORAug 17, 2007 · N163YV · Beech 1900DSDR AMWA86724BCBattery · false indicationDURING A FERRY FLIGHT, THE BATTERY CHARGE ANNUNCIATOR ILLUM IN FLT. ACFT LANDED WITH NO FURTHER INCIDENT. THIS IS A NUISANCE WRITEUP AND DISTRACTION TO THE AIR CREW. RAN ACFT, SYSTEM OPS CHECKED NORMAL, COULD NOT DUPLICATE.Aug 17, 2007 · N133YV · Beech 1900DSDR UPS07650392Battery · dischargedINSPECTION TYPE:ETOP APU INOP. FOUND APU BATTERY SHOWS 1 VOLT. REMOVED AND REPLACED APU BATTERY PER MM 24-31-04. RAN APU WITH NO FAULTS.Aug 3, 2007 · N307UP · Boeing 76734AFSDR DLM88071045Charger · burnedDURING PREFLIGHT, BATTERY CHARGER C/B POPPED WITH ODOR/SMOKE IN COCKPIT/CABIN. BATTERY CHARGER REPLACED. UPON TEAR DOWN IN THE SHOP BATTERY CHARGER WAS SEVERELY CHARRED INTERNALLY. THERE WAS SUFFICIENT HEAT TO DISTORT THE ALUMINUM COVER.Aug 2, 2007 · N936DL · Doug MD88SDR N843E12007Hed · faultedCREW LEFT STATION. TWENTY MINUTES IN FLIGHT "BATT TIE OPEN" ANNUNCIATOR ILLUMINATED. CREW RETURNED TO STATION WITHOUT ISSUE. REMOVED AND REPLACED BATTERY HED. OPS CHECK GOOD.Aug 1, 2007 · N843E · Beech 1900DSDR UPS07650391Charger · malfunctionedINSPECTION TYPE:ETOP EICAS MSG MAIN BATTERY CHARGER DISPLAYED. BATTERY DISCHARGE LIGHT DID NOT ILLUMINATE. SWAPPED APU BATTERY CHARGER WITH MAIN BATTERY CHARGER IAW 24-31-02-4 & 24-31-05-4. MAIN BATTERY CHARGER OPS NORMAL.Aug 1, 2007 · N320UP · Boeing 76734AFSDR 2007UALA02945Battery · shortedBATTERY CHARGER C/B P6-4 D8 WILL NOT STAY SET, IT CONTINUOUSLY POPS. FOUND SHORTED BATTERY. REPLACED THE BATTERY AND BATTERY CHARGER.Jul 31, 2007 · N202UA · Boeing 737322SDR C2XA07ON014Battery · overtempFLT 7756 -IN FLIGHT, CREW REPORTED BATTERY NR 2 OVERTEMP. CREW PERFORMED QRH WAS 59 DEGREES CELSIUS, DURING LANDING BATTERY TEMP INCREASED SLOWLY TO 70 DEGREES CELSIUS. CREW RECOMMENDED TO SHUT ALL POWER. FIRE TRUCKS WERE CALLED UPON LANDING BUT CREW NEVER DECJul 28, 2007 · N22909 · Emb EMB145LRSDR MWEA070161Battery · malfunctionedAFTER LANDING, SMELLED ELECTRICAL ODOR, CREW NOTICED SMOKE COMING OUT NEAR E&E DOOR. REMOVED AND REPLACED LEFT & RIGHT MAIN BATTERIES.Jul 24, 2007 · N803ME · Doug DC981SDR UPS07650329Charger · inoperativeINSPECTION TYPE:ETOP MAIN BATTERY CHARGER STATUS MESSAGE DISPLAYED. REMOVED AND REPLACED MAIN BATTERY CHARGER IAW MM 24-31-02-4 AND MAIN BATTERY IAW MM 24-30-01-4 SYSTEM CHECKS GOOD IAW BOTH.Jul 22, 2007 · N331UP · Boeing 76734AFSDR AC2A116668Relay · unknownRELAY INTERNAL PROBLEM.Jul 19, 2007 · N39LR · Bell 206L1SDR UPS07650331Charger · unknownINSPECTION TYPE:ETOP AT ENG SHUTDOWN RECEIVED ADVISORY LEVEL EICAS MESSAGE "MAIN BAT CHGR". ACCOMPLISHED FIM PROCEDURE 31-41-00/101 SYSTEM CHECKS OK.Jul 13, 2007 · N324UP · Boeing 76734AFSDR 2007UALA02548Charger · inoperativeMAIN BATTERY CHARGER DISPLAYED. [08-08-07] REPLACED MAIN BATTERY CHARGER WITH APU BATTERY CHARGERJul 10, 2007 · N561UA · Boeing 757222SDR 2007UALA02547Charger · inoperativeMAIN BATTERY CHARGER WILL NOT ERASE ON ECS MSG. [08-08-07] REPLACED MAIN BATTERY AND MAIN BATTERY CHARGERJul 10, 2007 · N567UA · Boeing 757222SDR 2007UALA02546Charger · unknownMAIN BATTERY CHARGER STATUS MESSAGE DISPLAYED. [08-08-07] REPLACED AC MAIN BATTERY AND CHARGER.Jul 10, 2007 · N514UA · Boeing 757222SDR 2007UALA02420Light · inoperativeAIRCRAFT FAILS STANDBY POWER TEST. STANDBY POWER LIGHT DOES NOT ILLUMINATE WHEN STANDBY POWER IS TURNED OFF, AC POWER REMAINS ON. [07-27-07] FAULTY STANDBY POWER RELAY AND STANDBY AC VOLTAGE SENSOR. REPLACED THE STANDBY POWER RELAY (R238) AND STANDBY AJul 5, 2007 · N910UA · Boeing 737522SDR 2007UALA02243Battery · dischargedCREW REPORT: AC FOUND WITH BATTERY DEAD AND BATTERY C/B POPPED. RESET AND POPPED AGAIN. FOUND FAULTY BATTERY AND BATTERY CHARGER. REPLACED BATTERY AND BATTERY CHARGER. NO FAULTS FOUND ON BOTH THE BATTERY AND BATTERY CHARGER.Jun 24, 2007 · N337UA · Boeing 737322SDR YENA2007056Battery · overtempON TAKEOFF ROLL BATTERY NR 2 OVERTEMP EICAS MESSAGE. T/S TSM 24-36-810-804-A. REMOVED AND REPLACED NR 2 MAIN BATTERY, GROUND CHECK OK.Jun 24, 2007 · N184JB · Emb ERJ190100IGWSDR AMWA85564BCBattery · weakDURING FLT, THE BATTERY CHARGE ANNUN ILLUMINATED. CONTINUED TO DESTINATION WITH NO FURTHER INCIDENT. THIS BATTERY CHARGE ANNUNCIATOR WRITEUP UP IS A NUISANCE WRITEUP WITH SEVERE DISTRACTION TO THE AIR CREW.REMOVED AND REPLACED BATTERY AND ADJUSTED VOLTAGE REJun 24, 2007 · N142ZV · Beech 1900DSDR 2007UALA02215Battery · faultyFOUND MAIN BATTERY AT 17V AND DISCHARGING AT 4A. [07-20-07] REPLACED MAIN BATTERY PER MM24-31-01. TESTS OK FOR RETURN TO SERVICE.Jun 22, 2007 · N227UA · Boeing 777222SDR 2007UALA02158Charger · failedMAIN BATTERY MAIN BATTERY CHARGER FAILURE. [07-17-07] REPLACED MAIN BATTERY AND ELMS CARD. OP CHECKED OK FOR SERVICE.Jun 22, 2007 · N227UA · Boeing 777222SDR DLM88070780Charger · failedON PREFLIGHT, FOUND BATTERY CHARGER C/B POPPED. RESET AND RAN EMERGENCY POWER CHECK. FOUND BATTERY CHARGER C/B RE-POPPED. T/S PER WDM FOUND A AND C PHASE WIRES FROM C/B TO CHARGER BOTH MOUNTED ON C PHASE LUG. REWIRED C/B PER WDM. REPLACED BATTERIES AND CHJun 21, 2007 · N914DL · Doug MD88SDR 2007UALA02125Charger · faultyAT DEPARTURE MAIN BATTERY CHARGER MESSAGE. [07-17-07] REPLACED MAIN BATTERY CHARGER PER MM 24-31-02 . SUSPECT INTERNAL SHORT IN CHARGER.Jun 20, 2007 · N229UA · Boeing 777222SDR DLM88070754Charger · burnedBATTERY CHARGER CAUGHT ON FIRE AND POPPED C/B. INSTALLED NEW R2-56 RELAY NEW TEMP SENSORS, REINSTALLED BATTERY TRAY. INSTALLED NEW BATTERY CHARGER. REMOVED AND INSTALLED NEW BATTERY CHARGER C/B. BATTERIES LT S/N OFF 1030768 ON 10503139. RT S/N OFF 1050314Jun 19, 2007 · N914DL · Doug MD88SDR AMWA85394BCConnector · corrodedBATT CHARGE ANNUN ILLUMINATES 3-5 MIN, EXTINGUISHES BRIEFLY, RE-ILLUMINATES FOR 2+ MIN, THEN REMAINED EXTINGUISHED FOR REMAINDER OF FLT. CONTINUED TO DESTINATION W/O FURTHER INCIDENT. CLEANED CORROSION OFF OF CONNECTORJun 17, 2007 · N10675 · Beech 1900DSDR ABXA070182Charger · defectiveWHILE STARTING APU, NOTICED NOISE AND SMOKE EMITTING FROM BATTERY CHARGER. REPLACED BATTERY CHARGER IAW DC9 MM 24-30-02-2-0001. ALSO, REPLACED BOTH AIRCRAFT BATTERIES AND BATTERY TEMPERATURE SENSOR IAW DC9 MM 24-30-01-0-0001.Jun 13, 2007 · N970AX · Doug DC941SDR 2007UALA01941Warning System · activatedELEC - BATTERY 1 FAULT IN FLIGHT. NO PILOT ACTION REQUIRED. REPLACED BCL1 AND BATTERY NR 1.Jun 9, 2007 · N478UA · Airbus A320232SDR 2007UALA01895Battery · inoperativeFLIGHT DIVERTED DUE TO BATTERY MESSAGE. TEMPORARILY LOST ALL F-O FLT INSTRUMENTS. CAME BACK ON AFTER A FEW MINUTES. [08-07-07] FO INSTRUMENTS CAME BACK ON AFTER A FEW MINUTES. REPLACED MAIN BATTERY AND BATTERY CHARGER.Jun 8, 2007 · N560UA · Boeing 757222SDR AMWA85129BCCharger · looseAFTER TAXI FROM GATE THE BATTERY CHARGE ANNUN ILLUM. AC RETURNED TO GATE WITH NO FURTHER INCIDENT. THIS BATTERY CHARGE ANNUN ILLUM WRITEUP IS CONSIDERED A NUISANCE AND EXTREME DISTRACTION TO THE PILOT. RESEATED A-130 PCB, OPS CHECKED GOOD.Jun 5, 2007 · N127ZV · Beech 1900DSDR 85129BCCharger · looseAFTER TAXI FROM GATE THE BATTERY CHARGE ANNUN ILLUM. AC RETURNED TO GATE WITH NO FURTHER INCIDENT. THIS BATTERY CHARGE ANNUN ILLUM WRITEUP IS CONSIDERED A NUISANCE AND EXTREME DISTRACTION TO THE PILOT. RESEATED A-130 PCB, OPS CHECKED GOOD.Jun 5, 2007 · N127ZV · Beech 1900DSDR UPS07M49878Charger · inoperativeINSPECTION TYPE:N/A DIVERSION - BATTERY CHARGER LIGHT ILLUMINATED IN FLIGHT. T/S PER FIM 24-30-00 FIG 118. REPLACED BATTERIES PER MM 24-30-02 AND BATTERY CHARGER PER MM 24-34-03. EMERGENCY POWER TEST OK PER MM 24-24-00-5, NO MSG NOTED.Jun 1, 2007 · N259UP · Doug MD11FSDR FJ7A115661Battery · weakBATTERY, CONTINUALLY WEAK ON STARTS.May 29, 2007 · N174AM · Urocop EC130B4SDR 07FDEA02010Tru · smokeWHEN POWERING UP NOTICED SMOKE WAS COMING FROM THE AVIONICS DEPT, SHUT DOWN A/C. CHECKED OUT THE AREA, THE SMOKE WAS GONE. POWERED UP THE A/C AGAIN ECAM SHOWED T/R UNIT 2 INOP. INSPECTED THE AREA AGAIN, FOUND NO EVIDENCE OF SMOKE OR DAMAGE WIRING. REMOVED May 29, 2007 · N815FD · Airbus A310324SDR 2007UALA01633Charger · faultyMAIN BATTERY CHARGER STATUS MESSAGE DISPLAYED. [06-20-07] REPLACED A FAULTY BATTERY CHARGER.May 24, 2007 · N550UA · Boeing 757222SDR UPS07M49852Battery · dischargedDIVERTED - BATTERY LOW ALERT. REMOVED AND REPLACED MAIN BATTERIES PER AMM 24-34-02-4 & BATTERY CHARGER PER AMM 24-34-03-4. OPERATION TEST SATISFACTORY. PERFORMED EMERGENCY POWER SYSTEM TEST PER AMM 24-34-00-5. NO DISCREPANCY FOUND. A/C RETURNED TO SERVICEMay 24, 2007 · N257UP · Doug MD11FSDR 2007UALA01599Battery · looseMAIN BATTERY CHARGER STATUS MSG REPORTED BY CREW. INTERCHANGED MAIN BATTERY AND APU BATTERY PER MM 24-31-01 AND MM 24-31-04. SUSPECT FAULTY CONNECTION, CHARGER TO MAIN BATTERY. EICAS MSG ERASED AND NOW MAIN BATTERY OPERATES NORMALLY.May 21, 2007 · N672UA · Boeing 767322
Back to JASC 2432