SDR AMWA84785BCBattery · weakDURING FLT, THE BATTERY CHARGE ANNUN ILLUMINATED. ACFT LANDED WITH NO FURTHER INCIDENT. THIS BATTERY CHARGE ANNUN WRITEUP IS A NUISANCE A SEVERE DISTRACTION TO THE PILOTS. REMOVED AND REPLACED BATTERY.SDR 2007FA0000732Relay · failedAIRCRAFT EMERGENCY LANDED WITH COMPLETE ELECTRICAL FAILURE, LG EMERGENCY EXTENDED AND LANDED SAFELY. FOUND BATTERY RELAY FAILURE. UNIT REMOVED 200 AMP FOUND TO BE INCORRECT (PN). SB MEB99-4 ADDRESS THIS PROBLEM, HAD NOT BEEN COMPLIED WITH, CORRECT RELAY 100SDR AMWA84511BCCharger · warning lightBATTERY CHARGER ANNUNCIATOR ILLUMINATED IN FLT. ACFT LANDED WITH NO FURTHER INCIDENT. THIS BATTERY CHARGER ANNUNCIATOR ILLUMINATED WRITEUP IS CONSIDERED A NUISANCE AND A SEVERE DISTRACTION TO THE PILOTS. PARALLELED GENERATORS.SDR AMWA84489BCBattery · wornAT APPROX 2500 AGL, WELL AFTER LANDING GEAR RETRACTION, THE BATT CHG ANNUNCIATOR ILLUM AND REMAINED LIGHTED FOR 15-20 SEC, THEN EXTINGUISHED. ABNORMAL CKLIST PERFORMED, NO FURTHER INCIDENT. THIS BATT CHG ANNUNCIATOR ILLUM WRITEUP IS CONSIDERED A NUISANCE ANDSDR BB07036Charger · failedFLIGHT 740, PHL-MAD: DURING CRUISE, CREW RECEIVED A MAIN BATTERY CHARGER FAULT MESSAGE. FLIGHT RETURNED TO PHL. MAINTENANCE REPLACED THE BATTERY CHARGER. NO FURTHER FAULTS.SDR AMWA084392BCBattery · dischargedAFTER TAKEOFF, THE BATTERY CHARGE ANNUNCIATOR ILLUMINATED. CAPT RETURNED TO FIELD AND LANDED WITH NO FURTHER INCIDENT. THIS BATTERY CHARGE ANNUNCIATOR LIGHT ILLUM IS CONSIDERED A NUISANCE WARNING, CAUSING SERIOUS DISTRACTIONS TO THE PILOTS. CLEANED SHUNT ANSDR NSVA20070117Power Supply · reads lowDC EMERGENCY BUSS POWER SUPPLY VOLTAGES APPEAR LOW. TESTED EMERGENCY BATTERY VOLTAGE IAW SAAB AMM 24-35-00, OPS CHECK GOOD EMERGENCY PWR LIGHTS.
SDR AMWA84156BCBattery · dischargedBATT CHARGE ANNUN ILLUM IN FLT. NO INCIDENTS, ACFT CONTINUED TO DESTINATION. THIS BATTERY CHARGE ILLUMINATION IS CONSIDERED A NUISANCE WARNING, CAUSING SERIOUS DISTRACTION TO THE PILOTS. REMOVED AND REPLACED BATTERY.SDR AMWA84156Battery · dischargedBATT CHARGE ANNUN ILLUM IN FLT. NO INCIDENTS, ACFT CONTINUED TO DESTINATION. REMOVED AND REPLACED BATTERY.SDR 2007UALA01232Charger · faultyEICAS WHITE STATUS MSG "MAIN BAT CHGR" DISPLAYED. WILL NOT CLEAR. [06-14-07] REPLACED MAIN BATTERY AND CHARGER PER UA ENGINEERING SPECIFICATIONS.SDR AMWA83962BCBattery · dischargedBATTERY CHARGE ANNUN CAME ON IN FLT (ILLUM FOR 2-3 MIN THEN EXTINGUISHED) CAME ON AGAIN AND EXTINGUISHED AGAIN A FEW MINUTES LATER, ABNORMAL CKLIST ACCOMP BOTH TIMES (PROP AND W/S DEICE ON). THIS BATTERY CHARGE LIGHT ILLUM IS CONSIDERED A NUISANCE WARNING, CASDR 2007UALA01050Battery · faultyMAIN BATTERY CHG STATUS MSG. [SUP 5-1-07] REPLACED BATTERY CHARGER. CHECKS OK FOR SERVICE. SUSPECT CHARGER SHORTED OUT.SDR QXEA200700500Charger · failedPDX - FLIGHT 2575, ON TAXI RECEIVED A APU BATTERY CHARGER STATUS MESSAGE. RETURNED TO THE GATE. MAINTENANCE REPLACED THE APU BATTERY CHARGER. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.SDR C36001Unknown · unknown2 HOURS AFTER TAKEOFF ELECTRICAL ODOR IN COCKPIT. OBSERVED MAIN BATTERY VOLTAGE DROPPING THROUGH 22 VOLTS. WITHIN 10 MINUTES VOLTAGE HAD DROPPED TO 13 VOLTS AND ODOR WAS STRONGER. PULLED MAIN BATTERY CHARGER CIRCUIT BREAKER, VOLTAGE (BATTERY) STOPPED DROPPING SDR TRAX200700439Charger · faultedAFTER STARTING ENGINE NR 1, EMERGENCY BATTERY CHARGER FAULT LIGHT ILLUMINATED.SDR AC2A114643Battery · dischargedPILOT WORE BATTERY DOWN TRYING TO START AIRCRAFTSDR AC2A114642Battery · inoperativeINSPECTED BATTERY, BATTERY WOULD NOT ACCEPT CHARGE, BATERY OUTPUT VOLTAGE IS 5 VDC.SDR AMW083289BCBattery · false indicationBATTERY CHARGE ANNUNCIATOR ILLUMINATED IN FLIGHT, CREW RAN THE ABNORMAL CHECKLIST, BATTERY CHARGE RATES DECREASED, ANNUNCIATOR EXTINGUISHED, FLIGHT CONTINUED TO DESTINATION W/NO FURTHER INCIDENT. THIS BC ILLUMINATION IS CONSIDERED A NUISANCE WARNING, CAUSING SSDR DLM88070204Battery · unserviceableON TAXI IN RAMP REPORTED SMOKE/STEAM COMING FROM UNDER A/C. CALLED MTC TO INVESTIGATE SAME. FOUND SHIPS BATTERIES OVERHEATED. NO DAMAGE TO A/C, BATTERIES OR CHARGER. REPLACED MAIN BATTERIES AND CHARGER. OP AND SYSTEM TESTS OK.SDR DL76L070201Charger · inoperativeAT CRUISE, MAIN BAT CHG STATUS MSG BAT VOLTS 25, AFTER APPROX 45 MINS MSG DISAPPEARED. VOLTS WENT TO 28 AND DC-A WENT TO 11. REPLACED A/C MAIN BATTERY AND MAIN BATTERY CHARGER PER AMM. TEST OK.SDR AMW083151BCBattery · false indicationDURING FLT, BATTERY CHARGE ANNUN ILLUM. THIS BC ILLUMINATION IS CONSIDERED A NUISANCE WARNING, CAUSING SERIOUS DISTRACTION TO THE PILOTS. BATTERY WAS REPLACED WITH NO FURTHER INCIDENT.SDR 2007FA0000232Battery · failedTHESE 2 EA PN RG-380E/44 MAIN SHIP BATTERIES WERE INSTALLED ON 10/30/2006. THESE BATTERIES WERE REPLACEMENTS FOR 2 EA BATTERIES THAT HAD BEEN IN SATISFACTORY SERVICE IN THIS AC FOR APPROX 48 MONTHS BUT FAILED A CAPACITY CHECK DURING A REGULAR SCHEDULED INSPECSDR AWM083043BCBattery · false indicationBATTERY CHARGE ANNUN ILLUM IN FLT. UPON ARRIVAL AT DESTINATION, BATTERY WAS REPLACED WITH NO INCIDENT. THIS BATTERY CHARGE ILLUMINATION IS CONSIDERED A NUISANCE WARNING, CAUSING SERIOUS DISTRACTION TO THE PILOTS.SDR AMW082976BCBattery · false indicationWHILE IN FLT, THE BATTERY CHARGE ANNUN ILLUMINATED. CREW PROCEEDED TO DESTINATION, LANDED SAFELY WITH NO FURTHER INCIDENT. THIS BATTERY CHARGE LIGHT ILLUMINATION IS CONSIDERED A NUISANCE WARNING, CAUSING SERIOUS DISTRACTION TO THE PILOTS. REMOVED AND REPLACSDR AMW082983BCBattery · false indicationWHILE IN FLT, THE BATTERY CHARGE ANNUN ILLUMINATED. CREW PROCEEDED TO DESTINATION, LANDED SAFELY WITH NO FURTHER INCIDENT. THIS BATTERY CHARGE LIGHT ILLUMINATION IS CONSIDERED A NUISANCE WARNING, CAUSING SERIOUS DISTRACTION TO THE PILOTS. REMOVED AND REPLACESDR 2007FA0000208Battery · leakingBATTERY ACID LEAKED OR TRANSFERRED TO AFT, LOWEST CELL (AIRCRAFT TAIL WHEEL) AND SPILLED OUT. CORRODED HOLE IN BATTERY BOX AND SPILLED INTO BELLY OF AIRCRAFT.SDR 2007FA0000207Battery · leakingBATTERY ACID LEAKED OR TRANSFERRED TO AFT, LOWEST CELL (AIRCRAFT TAIL WHEEL) AND SPILLED OUT. CORRODED HOLE IN BATTERY BOX AND SPILLED INTO BELLY OF AIRCRAFT.SDR 2007UALA00582Charger · faultyBATTERY MAIN CHARGER STATUS MESSAGE. MAIN BATTERY CHARGER FAILURE MESSAGE. ACTIVE ES HARD FAULT. AFTER TROUBLESHOOTING, REPLACED MAIN BATTERY. SYSTEM CHECKS OKSDR AMW082669BCBattery · false indicationWHILE IN FLT, THE BATTERY CHARGE ANNUNCIATOR ILLUMINATED. CREW PROCEEDED TO DESTINATION, LANDED SAFELY WITH NO FURTHER INCIDENT. THIS BATTERY CHARGE LIGHT ILLUMINATION IS CONSIDERED A NUISANCE WARNING, CAUSING SERIOUS DISTRACTION TO THE PILOTS. REPLACED BATTSDR AMWA82479BCBattery · dischargedBATTERY CHARGE LIGHT ILLUMINATED IN FLIGHT. MAINTENANCE REPLACED BATTERY TO CLEAR THE DISCREPANCY. THIS BATTERY CHARGE LIGHT ILLUMINATION IS CONSIDERED A NUISANCE WARNING, CAUSING SERIOUS DISTRACTION TO THE PILOTS.SDR 2007FA0000174Hose · disconnectedBATTERY ELECTROLYTE RESIDUE FOUND ON LT NOSE GEAR DOOR AND LOWER FORWARD FUSELAGE. INSPECTION REVEALED BATTERY BOX DRAIN HOSE DISCONNECTED AND HANGING IN LOWER NOSE STRUCTURE AREA BELOW THE BAGGAGE FLOOR. ACCESS IS HINDERED BY NUMEROUS FASTENERS THAT ARE HARSDR AMWA82340BCBattery · dischargedBATTERY CHARGE ANNUNCIATOR ILLUMINATED IN FLIGHT. MAINTENANCE REPLACED BATTERY TO CLEAR DISCREPANCY. THIS BATTERY CHARGE LIGHT ILLUMINATION IS CONSIDERED A NUISANCE WARNING, CAUSING SERIOUS DISTRACTION TO THE PILOTS.SDR AMWA82342BCBattery · dischargedBATTERY CHARGE LIGHT ILLUMINATED IN FLIGHT. MAINTENANCE REPLACED BATTERY TO CLEAR DISCREPANCY. THIS BATTERY CHARGE LIGHT ILLUMINATION IS CONSIDERED A NUISANCE WARNING, CAUSING SERIOUS DISTRACTION TO THE PILOTS.SDR 2007UALA00222Charger · faultyBATTERY 2 FAULT ON GROUND. REPLACED NR 2 BATTERY AND BATTERY CHARGER. BATTERY OPS CHECKED NORMAL.SDR CA070202006Diode · failed(CAN) SINCE THE DIODE FAILED, A DIRECT SHORT TO GROUND OCCURED. CAUSING THE BATTERY CIRCUIT WIRING TO BURN OFF ITS SHIELDING AND THE DIODE PIG TAIL FROM X1 TO X2 ON THE RELAY HEATED UP TO THE POINT OF BREAKING, FLAME WAS PRESENT. THE BATTERY SWITCH WAS NOT DSDR AMWA82203BCBattery · dischargedBATTERY CHARGE LIGHT ILLUMINATED IN FLIGHT. MAINTENANCE CHARGED THE BATTERY AS NEEDED TO CLEAR DISCREPANCY. THIS BATTERY CHARGE LIGHT ILLUMINATION IS CONSIDERED A NUISANCE WARNING, CAUSING SERIOUS DISTRACTION TO THE PILOTS.SDR AMWA82619BCBattery · dischargedBATTERY CHARGE LIGHT ILLUMINATED IN FLIGHT. MAINTENANCE REPLACED BATTERY TO CLEAR DISCREPANCY. THIS BATTERY CHARGE LIGHT ILLUMINATION IS CONSIDERED A NUISANCE WARNING, CAUSING SERIOUS DISTRACTION TO THE PILOTS.SDR ASAA0741388Battery · overheatedFLT CREW AND FLT ATTENDANTS REPORT BURNING PLASTIC SMELL IN CABIN AND COCPIT JUST BEFORE BEGINNING DESCENT. FOUND MAIN BATTERY VOLTAGE LESS THAN 20 VOLTS BATTERY VERY WARM AND SMELLING HOT REPLACED BATTERY.SDR AALA20070001Charger · inoperativeSTL - BATTERY CHARGER LIGHT ILLUMINATED IN FLIGHT. BATTERY CHARGER CIRCUIT BREAKER POPPED. LANDED STL WITHOUT INCIDENT. REPLACED BATTERY CHARGER. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR YENA2007001Battery · overtempBATTERY 2 OVERTEMP MESSAGE APPEARED ON TAXI. TROUBLESHOT PER E190 FIM TASK 24-36-00-810-804-A. REMOVED AND REPLACED BATTERY NR 2 PER AMM PART II 24-36-01. OPS CHECKED NORMAL.SDR HALA0600924Battery · unknownETOPS SIGNIFICANT SYSTEM, STATUS MSSG 'MAIN BATT CHARGER'. REMOVED AND REPLACED LOANER BATTERY PER AMM 24-31-01. OPS CHECK SECURITY CHECK GOOD.SDR SWAA065065Charger · faultyDIVERSION (OKC - MCI) TR-1 C/B TRIPPED, FOLLOWED BY FUMES. BATTERY CHARGER C/B TRIPPED DURING TAXIING. REMOVED AND REPLACED ACFT BATTERY CHARGER, AND TR-1 PER MM.SDR CA061128008Battery · thermal runaway(CAN) WHILE CONNECTED TO A GPU, DURING ROUTINE MAINTENANCE, THE TECHNICIANS NOTED SMOKE IN THE AREA OF THE BATTERY BOX COMPARTMENT. THE GPU WAS IMMEDIATELY DISCONNECTED, BATTERY POWER TURNED OFF AND THE BATTERY DISCONNECTED FROM THE AIRCRAFT BY REMOVAL OF THE SDR QXEA200602951Charger · failedPDX - FLIGHT 2345 - ON PUSHBACK AND ENGINE START, APU BATTERY CHARGER STATUS MESSAGE RECEIVED. RETURNED TO THE GATE. MAINTENANCE REPLACED THE APU BATTERY CHARGER IAW AMM 24-32-07-000-801-A02 AND OPERATIONAL CHECKS GOOD IAW 24-32-07-400-801-A02. AIRCRAFT RETSDR NSVA200600186Battery · overheatedR BAT HOT/R BAT LIGHT ON IN FLIGHT. R BAT TEMP WITHIN LIMITS A POST FLIGHT INSPECTION DISCOVERED PAINT BUBBLING ON RT BAT DOOR. CHARRING AND BURN MARKS EXIT OF A/C AND INTERIOR OF RT BAT. REMOVED AND REPLACED RT BATTERY CABLE HARNESS IAW 24-34-00 ALSO REMOVSDR SWAA064072Charger · faultyINFLIGHT HAD UNIDENTIFIABLE ODOR IN CABIN, TURNED OFF RECIRC FAN AND GASPER FAN. ODOR DISSIPATED, ON TOUCHDOWN ELECTRIC LIGHT ON ELECTRIC PANEL ILLUMINATED. ODOR FOUND TO BE COMING FROM BATTERY CHARGER. REMOVED AND REPLACED BATTERY CHARGER PER MM.SDR YENA200677Battery · failedAFTER DEPARTURE RECEIVED BATTERY NR 2 OVERTEMP (RED) ON EICAS. PERFORMED QRH AND LANDED BACK IN IAD. BATTERY REMOVED AND REPLACED PER AMM 24-36-01-04, OPS CHECK OK.SDR MALA060577Battery · failedFAILED CAP CHECK. REPLACED BATTERY PACK.SDR DL76L060779Battery · unknownBATTERY CHARGER LIGHT CAME ON. REPLACED BATTERY. OPS CHK NORMAL ETOPS CATEGORY (B): DIVERSION OR TURNBACK.SDR QXEA200602434Battery · contaminatedGEG FLIGHT NR 2357 - AUX BATTERY WILL NOT GO BELOW .10 FOR TAKEOFF, JUMPING BETWEEN .12 - .46. AFTER SHUTDOWN MINGO BATTS OFF AUX STILL SHOWING LOAD OF .26. MAINTENANCE REMOVED MOISTURE FROM AUX BATTERY, SHUNTS. LOADS RETURNED TO NORMAL. GROUND RAN AIRCRAF