Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026101620406Oven · contaminatedON APPROACH THE FA SAID SHE SMELLED SMOKE IN THE AFT GALLEY NEAR THE LT REAR EXIT. HAD A BURNT OVEN ODOR. INVESTIGATED REPORTED CABIN BURNT SMOKE ODOR PER TSM 05-50-00-810-813-A. IDENTIFIED BURNT MATERIAL ON OVEN RACKS IN THE AFT GALLEY AT LOCATIONS 404 AND 4SDR CALA2026101220264Oven · contaminatedFA REPORTED SMOKE IN FWD GALLEY FROM OVEN ON DEPARTURE. F/A STATED SMOKE WAS FROM FWD GALLY OVEN 205, AFTER EVAL FOUND OIL PUDDLE INSIDE OVEN AND MX WAS ABLE TO DUPLICATE SMOKE/ODOR. HAD OVEN CLEANED REF AMM 25-32-03 AND RAN OVEN AGAIN AND NO SMOKE/ODOR PRESESDR CALA2026101220259Oven · contaminatedBURNING PLASTIC ODOR IN AFT GALLEY. DE-POWERED GALLEY AND WENT AWAY. INSPECTED AND OPS CHECKED AFT GALLEY IAW AMM 05-51-58-800-801-C3. FOUND PLASTIC WRAPPER BLOCKING THE OVEN R53 VENT. REMOVED BLOCKAGE AND OPS CHECKED. OPS CHECK GOOD. ODOR DID NOT COME BASDR DALA2026100805569Coffeemaker · odorDIVERTED TO BOI DUE TO FAINT ODOR OF BURNT TOAST IN THE AFT CABIN. FOUND STRONG ODOR COMING FROM COFFEE MAKER A508 (AFT LEFT). NO BURNING SIGNS AT ELECTRICAL CONNECTOR. REPLACED COFFEE MAKER. (LP 9090469, 9090472 - AIRCRAFT WAS GROUNDED)SDR CALA2026100720207Coffeemaker · faultyPLASTIC BURNING ODOR IN AFT GALLEY WHEN COFFEE MAKERS 608 609 AND 610 ARE ON FOUND BURNING PLASTIC SMELL WHEN COFFEE MAKER 608 IS BREWING. VERIFIED ODOR WAS COMING FROM COFFEE MAKER 608. COFFEE MAKERS 609 AND 610 DO NOT PRODUCE ODOR. OPEN C/B FOR COFFEE MAKERSDR AALA202610088200Chiller · odorAIRCRAFT WAS NOT GROUNDED: AFT GALLEY CHILLER INOP. CABIN CREW NOTICED THE AFT GALLEY CHILLER WAS NOT OPERATING PROPERLY AND HAD AN ODOR BEFORE SHUTTING THE CHILLER OFF. (OPEN)SDR AALA202610050411Chiller · defectiveCOMPONENT IN SHOP MAINTENANCE: STRONG ELECTRICAL SMELL IN THE AFT PART OF THE CABIN SMELLED BY BOTH FLIGHT ATTENDANTS FOLLOWED BY A MUSTY SCENT - MAINTENANCE FOUND AFT GALLEY CHILLER POPPING CIRCUIT BREAKER WHICH WAS CAUSING ELECTRICAL SOF EVENT. (OPEN)SDR AALA202610057652Coffeemaker · defectiveAIRCRAFT WAS GROUNDED: CHEMICAL BURNING ODOR OBSERVED IN MAIN CABIN AND GETS STRONGER THE FURTHER BACK - MAINTENANCE REPLACED BOTH COFFEEMAKERS PER AMM 25-35-15SDR DALA2026093005421Oven · odorATB - DUE TO ELECTRICAL SMELL THROUGHOUT CABIN. REPLACED OVENS 1 AND 3 IN GALLEY 407. PERFORMED ALL SMOKE AND FUME PROTOCOLS. OK FOR SERVICE. (9166182) AIRCRAFT WAS GROUNDED.SDR DALA2026092905420Oven · odorFA REPORTED FWD GALLEY FWD GALLEY OVEN WAS SMOKING & SMELLED OF BURNING WIRES. SHUT OFF OVEN & ODOR DISAPPARED. NO SMOKE OR FUMES IN FLIGHT DECK. C/W MSI PREVENTION PROGRAM ATA 2172 SMOKE / ODOR EVENT. R & R FWD GALLEY OVEN IAW AMM 25-31. CHECKS GOOD. R & RSDR SWAA2026100288671Coffeemaker · odorAFT GALLEY, RIGHT COFFEE MAKER SMELLS LIKE RUBBER WHILE BREWING COFFEE. REMOVED AFT RT COFFEE MAKER AND INSTALLED A SERVICEABLE UNIT IAW AMM 25-30-01.SDR SWAA2026100225491Coffeemaker · contaminatedBURNT SMELL IN AFT GALLEY, SUSPECT COFFEE MAKER BURNING ODOR IN AFT GALLEY SUSPECT COFFEE MAKER VARIFIED. RESIDUAL COFFEE IN POT. CLEANED RESIDUAL COFFEE FROM BOTH POTS. OPS CHECKED GOOD. NO ODORS NOTED IAW AMM 25-30-01SDR AALA202609302093Oven · odorAIRCRAFT WAS GROUNDED: FFLIGHT ATTENDANT REPORTS BURNING PLASTIC SMELL IN THE FORWARD GALLEY AND FIRST-CLASS SECTION - THE SMELL WAS ALSO REPORTED IN THE BACK OF THE CABIN AND AFT GALLEY AREA - MAINTENANCE FOUND FWD GALLEY OVEN NR 2 DOOR BURNT AND SMOKING DURISDR AALA202609297709Oven · odorAIRCRAFT WAS GROUNDED: DURING CLIMB FUMES IN CABIN AROUND ROW 8. DECESION MADE TO RETURNED TO CLT. EMERGENCY DECLARED AND AIRCRAFT LAMDED WITHOU INCIDENT. AARF WAS DEPLOYED AS A PRECAUTION. MAINTENANCE FOUND SOURCE OF THE ODOR TO BE FWD GALLEY INBOARD AND OUTSDR AALA202609292391Oven · odorAIRCRAFT WAS GROUNDED: DURING CLIMB FUMES IN CABIN AROUND ROW 8. DECESION MADE TO RETURNED TO CLT. EMERGENCY DECLARED AND AIRCRAFT LAMDED WITHOU INCIDENT. AARF WAS DEPLOYED AS A PRECAUTION. MAINTENANCE FOUND SOURCE OF THE ODOR TO BE FWD GALLEY INBOARD AND OUTSDR J7SA2026100500529Coffeemaker · odorBURNING ODOR MOMENTARILY DETECTED FROM GALLEY AC POWER OUTLET AFTER COFFEE MACHINE FAILED. COFFEE MACHINE DISCONNECTED AND AIRCRAFT LANDED WITHOUT INCIDENT. REPLACED KEURIG COFFEE MAKER, OPS CHECK GOOD.SDR CALA2026092419788Trash Bin · dirtyFLIGHT ATTENDENT REPORTS FWD GALLEY TRASH CART NEEDS TO BE CLEANED. SMELLS VERY BAD CLEANED FWD GALLEY TRASH CAN IN REF TO AMM 12-40-00. NO ORDOR OR BAD SMELL NOTICED.SDR CALA2026101920437Oven · dirtyGALLEY WARMING OVEN SMOKING OR SPARKING IN THE AFT GALLEY. SMOKE AFTER APPROX 5 MIN DEBRIEFED CREW AND CREW STATED WHILE COOKING MEALS AT NR 3 OVEN OF AFT GALLEY, OVEN STARTED SMOKING. DID NOT SMELL LIKE ELECTRICAL SMOKE. SUSPECT FOOD BURNING CAUSED SMOKE. OVSDR CALA2026092519803Oven · smokeGALLEY OVEN 423 BEGAN SMOKING AFTER USE. FA TURNED OFF AND REMAINED UNUSED. CIRCUIT BREAKER COLLARED & OVEN DEACTIVATED. STICKER APPLIED. CLEANED AND RESET OVEN 423, WHEN OPERATING OVEN AN ODOR WAS NOTICED. WHEN OVEN OFF, ODOR GONE. PERFORMED SMOKE/ODOR ISDR AALA202609230984Oven · smokeAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTS SMOKE FROM FORWARD GALLEY OVEN 2 AND THE SMOKE DISSIPATED WHEN THE OVEN WAS TURNED OFF - MAINTENANCE REPLACED THE OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECKSDR AALA202609232989Oven · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTED THAT BOTH FORWARD GALLEY OVENS HAVE AN UNUSUAL SMELL WHEN IN USE - MAINTENANCE REPLACED THE POSITION 1 OVEN *AALA202609231705* AND POSITION 2 OVEN *AALA202609232989* IN THE FORWARD GALLEY - A SATISFACTORY OPSDR AALA202609231705Oven · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTED THAT BOTH FORWARD GALLEY OVENS HAVE AN UNUSUAL SMELL WHEN IN USE - MAINTENANCE REPLACED THE POSITION 1 OVEN *AALA202609231705* AND POSITION 2 OVEN *AALA202609232989* IN THE FORWARD GALLEY - A SATISFACTORY OPSDR CALA2026092219685Oven · odorOVEN 204 SMOKING, FA NOT SURE IF IT WAS RESIDUAL FOOD OR MAINT ISSUE. CLEANED AND RESET OVEN 204, WHEN OPERATING OVEN, A PECULIAR ODOR WAS NOTICED AS OVEN OPERATED. WHEN OVEN OFF, ODOR WAS GONE. SUSPECT FAULTY OVEN AND REQUESTING OVEN 204 MEL. OVEN 204, CB SDR AALA202609214785Oven · sparksAIRCRAFT WAS NOT GROUNDED: OVEN 1 BLEW A FUSE IN FLIGHT AND THE FLIGHT ATTENDANT REPORTED SPARKS AND A PUFF OF SMOKE BEFORE TURNING THE OVEN OFF - MAINTENANCE OPERATED THE OVEN FOR 30 MINUTES WITH NO SPARKS OR SMOKE NOTEDSDR CALA2026091819552Oven · smokeOVEN 606 CAUSING SMOKE, DURING COOKING PROCESS. CLEANED OVEN, DOOR SEAL, AND SURROUNDING FACE. OPS TESTED OVEN IAW AMM 25-32-02-200-802-001, TESTED GOOD, UNABLE TO DUPLICATE SMOKE OR ODOR.SDR CALA2026091819528Flapper Valve · obstructedRIGHT AFT LAV FLAPPER DOOR STUCK OPEN. AIRCRAFT HAD A BAD ODOR. REMOVED WASTE FROM RIGHT AFT LAV FLAPPER. FLAPPER AND FLUSH OPS CHECKED OK.SDR DALA2026091705184Oven · odorACRID BURNING CHEMICAL ODOR FWD GALLEY. FOUND STRONG ACRID/BURNING ODOR AFTER OPERATION OF THE OVEN FOR 20 MINS. REPLACED FORWARD GALLEY OVEN REF AMM 25-35MCC CONF. (LP 1815630, 9141656 - AIRCRAFT WAS GROUNDED)SDR CALA2026092919965Check Valve · odorFA REPORTS AFT GALLEY CHILLER HAS BURNING ODOR, LIGHT ILLUMINATED. SWITCHED OFF ODOR GONE, APPLY NEF 2500FY. R & R THE GALLEY CHILLER IAW AMM 25-33-01. OPS CHKD GOOD. OK FOR SVC.SDR YENA2026091600804Oven · failedFLT 633, BOS-SFO. FWD GALLEY FAR RT OVEN EMMITTED FAINT ELEC BURNING ODOR ALONG WITH BEEPING NOISE. OVEN WAS SHUT OFF FOR REMIANDER OF FLIGHT SMELL SUBSIDED. ( OVEN ), PLACED OVEN 104 ON NEF N25-30-09B -NO LEAKS NOTED- PULLED AND COLLARD C/B OVEN 104 PER NEF ISDR AALA202609163714Oven · odorAIRCRAFT WAS NOT GROUNDED: POSITION 1 OVEN EMITTING SMELL OF BURNING PLASTIC WHEN TURNED ON AND THE SMELL DISSIPATED IMMEDIATELY AFTER TURNING THE OVEN OFF - THERE WAS NO SIGN OF SMOKE OR EVIDENCE OF ANYTHING BURNING - THE SMELL OF BURNT PLASTIC WAS ONLY NOTICSDR AALA202609166074Oven · odorAIRCRAFT WAS GROUNDED: FORWARD GALLEY OVEN HAS FOUL ODOR - MAINTENANCE REPLACED OVEN PER AMM 25-35-19SDR CALA2026091719489Oven · smokeFWD GALLEY OVEN 106 LIGHT SMOKE WHEN TURNED ON. FWD GALLEY DEACTIVATED BY OPEN N COLLARED CB. INOPERATIVE STICKER ON AFFECTED OVEN PLACARDED. CLEANED FWD GALLEY OVEN 106. OPS CHECK GOOD. COMPLIED WITH MEL.SDR CALA2026091119378Oven · fodACRID ODOR POSSIBLY FROM PACKS NOTED BY INBOUND CREW AND AT GATE. OPERATED LT & RT PACKS INDIVIDUALLY. CANNOT CURRENTLY DETECT WHAT INBD FA ARE DESCRIBING. WALKTHROUGH OF CABIN - NO GALLEY EQUIPMENT GIVING SIGNS OF ODOR OR BURNING. NO NOTICEABLE ODOR FROM LSDR SWAA2026091082441Coffeemaker · odorFWD COFFEE MAKER SMELLS LIKE MELTING PLASTIC WHILE BREWING R/R FWD COFFEE MAKER PER AMM 25-30-01. OPS CHECK GOOD.SDR CALA2026090719300Oven · smokeOVEN/WARMER SMOKING. OVEN 710 HAD SMOKE AND BURNING ODOR. TURNED OVEN OFF & SMOKE & ODOR DISIPATED. OVEN TAPED CLOSED & NON USABLE. PRELIMINARY INSPECTION OF THE OVEN / WARMER, BURNING OVEN. CLEANED THE OVEN / WARMER, REMOVED ALL FOOD THAT WAS STUCK IN THESDR CALA2026090819310Oven · odorFWD GAL OVENS EMMITING ELEC SMELL. OVENS WILL REMAIN OFF REMAI NDER OF FLT. FWD GALLEY PERFORMED FWD GALLEY OVENS CLEANING REF AMM 25-32-03-100-801. NO BAD SMELL AT THIS TIME.SDR CALA2026090719269Oven · inoperativeRIGHT FORWARD OVEN NOT HEATING AND HAS BURNING ODOR, NO SMOKE. WILL NOT USE. PERFORMED FWD GALLEY RT OVEN OPS TEST IAW AMM 25-32-03. OVEN WORKING NORMALLY. NO BURNING ODOR. OK FOR SERVICE.SDR AALA202609071585Oven · smokeAIRCRAFT WAS NOT GROUNDED: OVEN 1 HAS SOMETHING BURNING AND SMOKING INSIDE. (OPEN)SDR CALA2026091119376Oven · dirtyOVEN SMOKING OR SPARKING 205, SPILLED FOOD IN OVEN CAUSES SMOKE WHEN ON NEEDS CLEANING OVEN HAS BEEN PLACARD AND DEACTIVATED IAW MEL ITEM # 2500BI. PERFORMED CONDITIONAL INSP OF OVEN IAW AMM 05-05-56, FOUND THE ODOR WAS COMING FROM THE OVEN WHICH HAS BEEN DESDR AALA202609066503Coffeemaker · odorAIRCRAFT WAS GROUNDED: REPEAT WRITE UP: ON FINAL APPROACH AND AFTER LANDING FLIGHT ATTENDANTS REPORTED A BURNING SMELL IN THE AFT AND FORWARD GALLEYS. THIS IS A REPEAT WRITE UP. MX FOUND FOUND FWD GALLEY OVEN NR 1 BURNING SMELL. REMOVED AND REPLACED FWD GALLEYSDR AALA202609062656Oven · odorAIRCRAFT WAS NOT GROUNDED: ON FINAL APPROACH AND AFTER LANDING, FLIGHT ATTENDANTS REPORTED A BURNING SMELL IN THE AFT AND FORWARD GALLEYS. MX COULD NOT REPRPRODUCE. ON NEXT FLIGHT ODOR REAPIRED AND MX FOUND FOUND FWD GALLEY OVEN NR 1 BURNING ODOR. REMOVED ANSDR DALA2026090304989Oven · contaminatedELECTRICAL BURNING SMELL 1ST 10 ROWS - LIGHT BUT NOTICABLE SEATS/ROWS 10, 11, & 12. OPERATED LT & RT FWD GALLEY OVENS TO VERY HIGH HEAT AFTER THEY CAME OUT OF COOL DOWN NOTICED AN ODOR AND A GOOD AMOUNT OF CAKED ON FOOD ON BACK PLATE OF LT OVEN. REPLACED LT SDR AALA202609028298Oven · odorAIRCRAFT WAS GROUNDED: FA REPORTED FAINT ELECTRICAL BURNING SMELL IN THE AREA OF THE FRONT LAVATORY AND GALLEY. ACCOMPLISHED JC 08L00021001. INSPECTED ELECTRONIC BAY, RECIRC FANS, FWD AND AFT CARGOS, ELECTRICAL OUTLETS AND USB PORTS, FWD GALLEY EQUIPMENT. FOUNSDR SCNA20260901377Coffeemaker · failedREAR COFFEE POT SMOKING, TURNED OFF & WILL NOT TURN BACK ON. R & R THE AFT GALLEY COFFEE MAKER IAW AMM 25-31-01, OPS CHKD GOOD.SDR AALA202608309828Oven · odorAIRCRAFT WAS GROUNDED: THE FLIGHT ATTENDANTS REPORT THAT WHEN STARTING TO USE THE LEFT OVEN A STRONG BURNING PLASTIC SMELL STARTED. THEY TURNED OFF THE OVEN AND THE SMELL DISSIPATED. MAINTENANCE REPLACED GALLEY OVEN IAW AMM 25-32-03 .SDR CALA2026090119170Oven · fumesFWD GALLEY OVEN (205) REQUIRES REPLACEMENT DO TO FUMES. REMOVED FWD GALLEY OVEN 205. INSPECTED AREA, ELEC CONNECTIONS, AAC CLEANED ANY DIRT, GRIM, & DEBRIS. INSTALLED NEW OVEN IAW AMM 25-32-03/501. OVEN IS BAD FROM STOCK. WILL NOT STAY ON, TRYED SWITCHED SDR CALA2026083119116Oven · odorACFT REQUIRES SMOKE ODOR INSPECTION IAW AMM 05-51-56-200-801. PERFORMED SMOKE ODOR INSPECTION IAW AMM 05-51-56-200-801 AND FOLLOWED FIM 21-00 TASK 830. PERFORMED VISUAL INSPECTION OF LT & RT A/C PACKS, NO DEFECTS NOTED. C/W APU ON & USING APU BLEED ON, RASDR AALA202608310567Chiller · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS REPORT A FAINT ELECTRICAL BURNING SMELL IN AND AROUND THE AFT GALLEY WHICH WAS POSSIBLY EMANATING FROM THE AFT CHILLERS WHICH WERE TURNED OFF AS A PRECAUTION. (OPEN)SDR CALA2026083119031Oven · odorINTERMITTENT FAINT BURNING PLASTIC ODOR IN FLT DECK & CABIN. THROUGHOUT FLT LASTING 1 MIN FAINT BURNING ODOR IN COCKPIT. ODOR PRESENT AT HIGH POWER SETTINGS, SUGGEST TAKING ACFT TO THE RUN-UP PAD TO ISOLATE ODOR. APU WAS OFF WHEN ODOR WAS PRESENT. OPS PACKSSDR CALA2026083119027Oven · faultyFOUL ODOR FROM RT SIDE FLT DECK THRU FWD GALLEY & ENDS AFT 1ST CLASS, FOUND FOUL ODOR COMING FROM OVEN 205 FWD GALLEY. R & R FWD GALLEY OVEN 205. IAW AMM 25-32-03-400-804. NO ODORS. OPS CHKD OK.
Back to JASC 2530