SDR CALA2026091119376Oven · dirtyOVEN SMOKING OR SPARKING 205, SPILLED FOOD IN OVEN CAUSES SMOKE WHEN ON NEEDS CLEANING OVEN HAS BEEN PLACARD AND DEACTIVATED IAW MEL ITEM # 2500BI. PERFORMED CONDITIONAL INSP OF OVEN IAW AMM 05-05-56, FOUND THE ODOR WAS COMING FROM THE OVEN WHICH HAS BEEN DESDR AALA202609066503Coffeemaker · odorAIRCRAFT WAS GROUNDED: REPEAT WRITE UP: ON FINAL APPROACH AND AFTER LANDING FLIGHT ATTENDANTS REPORTED A BURNING SMELL IN THE AFT AND FORWARD GALLEYS. THIS IS A REPEAT WRITE UP. MX FOUND FOUND FWD GALLEY OVEN NR 1 BURNING SMELL. REMOVED AND REPLACED FWD GALLEYSDR AALA202609062656Oven · odorAIRCRAFT WAS NOT GROUNDED: ON FINAL APPROACH AND AFTER LANDING, FLIGHT ATTENDANTS REPORTED A BURNING SMELL IN THE AFT AND FORWARD GALLEYS. MX COULD NOT REPRPRODUCE. ON NEXT FLIGHT ODOR REAPIRED AND MX FOUND FOUND FWD GALLEY OVEN NR 1 BURNING ODOR. REMOVED ANSDR DALA2026090304989Oven · contaminatedELECTRICAL BURNING SMELL 1ST 10 ROWS - LIGHT BUT NOTICABLE SEATS/ROWS 10, 11, & 12. OPERATED LT & RT FWD GALLEY OVENS TO VERY HIGH HEAT AFTER THEY CAME OUT OF COOL DOWN NOTICED AN ODOR AND A GOOD AMOUNT OF CAKED ON FOOD ON BACK PLATE OF LT OVEN. REPLACED LT SDR AALA202609028298Oven · odorAIRCRAFT WAS GROUNDED: FA REPORTED FAINT ELECTRICAL BURNING SMELL IN THE AREA OF THE FRONT LAVATORY AND GALLEY. ACCOMPLISHED JC 08L00021001. INSPECTED ELECTRONIC BAY, RECIRC FANS, FWD AND AFT CARGOS, ELECTRICAL OUTLETS AND USB PORTS, FWD GALLEY EQUIPMENT. FOUNSDR SCNA20260901377Coffeemaker · failedREAR COFFEE POT SMOKING, TURNED OFF & WILL NOT TURN BACK ON. R & R THE AFT GALLEY COFFEE MAKER IAW AMM 25-31-01, OPS CHKD GOOD.SDR AALA202608309828Oven · odorAIRCRAFT WAS GROUNDED: THE FLIGHT ATTENDANTS REPORT THAT WHEN STARTING TO USE THE LEFT OVEN A STRONG BURNING PLASTIC SMELL STARTED. THEY TURNED OFF THE OVEN AND THE SMELL DISSIPATED. MAINTENANCE REPLACED GALLEY OVEN IAW AMM 25-32-03 .SDR CALA2026090119170Oven · fumesFWD GALLEY OVEN (205) REQUIRES REPLACEMENT DO TO FUMES. REMOVED FWD GALLEY OVEN 205. INSPECTED AREA, ELEC CONNECTIONS, AAC CLEANED ANY DIRT, GRIM, & DEBRIS. INSTALLED NEW OVEN IAW AMM 25-32-03/501. OVEN IS BAD FROM STOCK. WILL NOT STAY ON, TRYED SWITCHED SDR CALA2026083119116Oven · odorACFT REQUIRES SMOKE ODOR INSPECTION IAW AMM 05-51-56-200-801. PERFORMED SMOKE ODOR INSPECTION IAW AMM 05-51-56-200-801 AND FOLLOWED FIM 21-00 TASK 830. PERFORMED VISUAL INSPECTION OF LT & RT A/C PACKS, NO DEFECTS NOTED. C/W APU ON & USING APU BLEED ON, RASDR AALA202608310567Chiller · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS REPORT A FAINT ELECTRICAL BURNING SMELL IN AND AROUND THE AFT GALLEY WHICH WAS POSSIBLY EMANATING FROM THE AFT CHILLERS WHICH WERE TURNED OFF AS A PRECAUTION. (OPEN)SDR CALA2026083119031Oven · odorINTERMITTENT FAINT BURNING PLASTIC ODOR IN FLT DECK & CABIN. THROUGHOUT FLT LASTING 1 MIN FAINT BURNING ODOR IN COCKPIT. ODOR PRESENT AT HIGH POWER SETTINGS, SUGGEST TAKING ACFT TO THE RUN-UP PAD TO ISOLATE ODOR. APU WAS OFF WHEN ODOR WAS PRESENT. OPS PACKSSDR CALA2026083119027Oven · faultyFOUL ODOR FROM RT SIDE FLT DECK THRU FWD GALLEY & ENDS AFT 1ST CLASS, FOUND FOUL ODOR COMING FROM OVEN 205 FWD GALLEY. R & R FWD GALLEY OVEN 205. IAW AMM 25-32-03-400-804. NO ODORS. OPS CHKD OK.SDR DALA2026082604856Coffeemaker · odorFA REPORTED AIRCRAFT RIGHT GALLEY VENT EMITTING BURNING ODOR. R & R COFFEE MAKER IAW 25-31. OPS CK GOOD. (9628062) AIRCRAT WAS GROUNDED.SDR CALA2026082518904Oven · odorOVEN 109 IN FWD GALLEY HAD LIGHT SMOKEY ODOR WHEN PLATES CAME OU T GALLEY OVEN 109 HEAVILY CONTAMINATED, CLEANED IAW AMM 25-05-03-100-801-C1. OVEN OPERATED FOR 10MINS. SMELL NO LONGER PRESENT.SDR CALA2026082318807Oven · odorBURNING ODOR AFTER TAKE OFF IN AFT GALLEY.GALLEY OVEN HEATER THE CAUSE AFT GALLEY FLIGHT ATTENDANT INFO: THE POWER CONTROL SWITCH WAS OFF AND IT SMELT LIKE A DUSTY/HOT AIR HEATER JUST TURNED ON. BUT THE FIGURED OUT THE POWER SWITCH WAS OFF. THE TURNED IT ON ANSDR AALA202608252483Oven · contaminatedAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO JFK DUE TO THE FLIGHT ATTENDANTS REPORTING AN ELECTRICAL BURNING SMELL IN BUSINESS CLASS GALLEY WHICH WAS CONFIRMED BY THE FIRST OFFICER - THE AIRCRAFT LANDED SAFELY AT JFK AND TAXISDR CALA2026082318814Oven · fodWARMING OVEN SMELLS BAD.OVEN 204 SMELLS LIKE BURNT TOAST. FOUND FOREIGN OBJECT IN BACK OF OVEN 204. SMALL PLASTIC BOTTLE HAD BEEN HEATED AND PRODUCED ODOR. REMOVED FOREIGN OBJECT AND ENSURED OVEN CLEAN AND OPERATES CORRECTLY. NO FURTHER DEFECTS /ODORS NOTED.SDR ASAA2026082266443Coffeemaker · odorATB DUE TO FUMES. BURNING RUBBER ODOR IN CRUISE. NO DIFFERENCE W/ ENG LEVEL 2/3. ODOR INTENSITY MODERATE FROM CRUISE TO LANDING 4L OVERHEAD SOURCE UNKNOWN. GROUNDED - YES. FLIGHT CREW REPORTS SULFAR ODOR IN AFT GALLEY THROUGHOUT FLIGHT. PERFORMED TSM 05-50-00-SDR IXXA20260820072Coffeemaker · failedCREW REPORTED BURNING SMELL FROM COFFEE POT. CIRCUIT BREAKER TRIPPED. PLACED ON DEFERRAL 76213 NON-ESSENTIAL FURNISHINGS NEF 120 PER ATI-25-20-01-01-N2001. REMOVED AND REPLACED GALLEY OVEN HOT CUP MODULE IN ACCORDANCE WITH IAI AMM SUPP 25-31-20. OPERATIONAL CSDR AALA202608215884Coffeemaker · odorAIRCRAFT WAS NOT GROUNDED: COFFEEMAKERS 5 AND 6 PRODUCED BURNING SMELL WHICH DISSIPATED WHEN BOTH COFFEEMAKERS WERE TURNED OFF - MAINTENANCE REPLACED COFFEEEMAKERS PER AMM 25-35-15SDR IXXA2026082002Shelf · damagedSUPERNUMERARY GALLEY SHELF IS MISSING METAL EDGESDR CALA2026082118771Oven · contaminatedCAPTAIN REPORTED AN ELEC BURNING ODOR IN THE MCD. PAX ALSO REPORTED A ELEC BURNING ODOR. PERFORMED GVI OF LT PACK, P6 & P18, C/B U PANELS, NO EVIDENCE OF BURNED WIRES OR ODOR. GVI INSPECTION IAW GMM05-51-26-800-801-C1. IAW OUTBOUND CREW, BURNING ODOR WAS NOSDR DALA2026081904750Oven · odorFUMES REPORTED IN THE FOWARD GALLEY APPROX 25 MIN AFTER TAKE-OFF GRADUALLY DISAPATED. R & R OVEN IAW AMM 25-31. OPS CHKD GOOD. (9573788) AIRCRAFT WAS GROUNDEDSDR CALA2026082518880Oven · contaminatedSMOKE OBSERVED COMING FROM OVEN 106. SMOKE ODOR WAS NOTICEABLE TEMPORARILY. DISCONTINUED USE AND THE SMOKE AND ODOR DISSIPATED. 106 OVEN INOPERATIVE, CB SAFETY COLLARED & PLACARDED. CLEANED OVER IAW DMC-B787-A-25-32-00-12A. NO NOTABLE SMOKE ODOR AT THIS TISDR CALA2026081718671Oven · odorSMOKE OBSERVED COMING FROM OVEN 106. SMOKE ODOR WAS NOTICEABLE TEMPORARILY. DISCONTINUED USE AND THE SMOKE AND ODOR DISSIPATED.SMOKE OR FUMES CABIN CONDITION CHKD IAW AMM 05-51-99 TO BE CUT OUT SYSTEM CHKD OK, NO STATUS MSG, NO EXTISTING FAULT. PERFORMED COSDR J7SA2026090300518Microwave Oven · inoperativeMICROWAVE DOES NOT HEAT WHEN TURNED ON AND EMITS AN ELECTRICAL BURNING SMELL UNTIL MICROWAVE IS TURNED OFF. REPLACED MICROWAVE IAW BD-100 SMM 25-30-03. OPS CHECK GOOD.SDR AALA202608175023Oven · odorAIRCRAFT WAS NOT GROUNDED: G1 OVEN 1B PRODUCES A STRONG BURNING/FIRE ODOR WHEN USED. MAINTENANCE REPLACED OVEN 1B OF FWD GALLEY IAW AMM 25-32-00.SDR QXEA2026081700173Oven · smokeFLIGHT 2192. NR 2 GALLEY FORWARD OVEN SMOKING DURING FLIGHT. SMELL WAS SIMILAR TO BURNT FOOD. REMOVED FROM SERVICE. REMOVED 3 COOKING TRAYS FROM #2 GALLEY OVEN WIPED UP RESIDUAL GREASE. PLACED ON NEF DEFERRAL GAL 07. TO BE REPAIRED OR REPLACED IN 300FH. RETURNSDR CALA2026081418595Coffeemaker · faultedFOUND AFT COFFEEMAKER 419 CIRCUIT BREAKER OPEN, CLOSED BREAKER & COFFEEMAKER PRODUCED A POP WITH BRIEF FLAME AND SMOKE. CIRCUIT BREAKER TRIPPED OPEN AGAIN. REPLACED THE COFFEEMAKER IN THE AFT GALLEY, CLOSED CIRCUIT BREAKER, OPS CHKD GOOD. PERFORMED INSP. FSDR AALA202608177882Chiller · odorAIRCRAFT WAS NOT GROUNDED: AFT CHILLER HAS A LOUD BUZZY NOISE AND AN ELECTRICAL BURNING SMELL - MAINTENANCE REPLACED AFT GALLEY AIR CHILLER UNIT PER AMM 25-34-51 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECKSDR DALA2026081204632Coffeemaker · faultedAFT INBD COFFEEMAKER WILL NOT SECURE. BOTH COFFEEMAKER CIRCUIT BREAKERS PULLED IN AFT GALLEY AS PRECAUTION DUE TO LOG 9170338. R & R AFT INBD COFFEEMAKER DISPENSER IAW AMM 25-35, OPS CHK GOOD. (LP: 9170339, AIRCRAFT WAS GROUNDED)SDR AALA202608147578Oven · odorAIRCRAFT WAS NOT GROUNDED: OVEN 1 DOES NOT HEAT WELL AND HAS A BURNT SMELL. MAINTENANCE REPLACED #1 FORWARD GALLEY OVEN PER AMM 25-35-19.SDR DALA2026081204631Coffeemaker · overservicedAIR TURNBACK, DUE TO REPORT OF A SMOKE/ODOR IN THE AFT. GALLEY. STOPPED WHEN COFFEEMAKERS WERE SHUT DOWN. FOUND COFFEEMAKER AT POSITION 509 OVERFILLED AND SPILLING ON HOT PLATE. REPLACED COFFEEMAKER. (LP: 9088798, AIRCRAFT WAS GROUNDED)SDR CALA2026081718661Coffeemaker · faultedCOFFEEMAKER AT POSITION 419 ELECTRICAL ODOR WHEN TURNED ON CREW PULLED COFFEE MAKER C/B PRECAUTIONARY DEFERRING COFFEEMAKER 419 PER NEF 2510AR. MX ACTION C/W OK TO APPLY NEF 2510AR FOR COFFEE MAKER 419 INOP DEFERRING COFFEE MAKER 419 PER NEF 2510AR. ESC RECSDR CALA2026081118463Coffeemaker · odorCONDITIONAL INSPECTION REQUIRED FOR ELECTRICAL ODOR FROM COFFEE MAKER 419. C/W CONDITIONAL INSPECTION, COFFEE MAKERS 419 AND 420. BREWED 2 POTS EACH , REMOVED AND INSPECTED BEHIND AND HARNESS. NO DISCREPANCIES NOTED. NO ODOR IAW AMM 05-51-26-800-801-C1. PRECSDR 2026FA0000735Oven · odorENROUTE FROM TEB TO CYVR AT FL 400 WHEN THE CREW DETECTED AN ELECTRICAL ODOR APPROXIMATELY TWO HOURS INTO THE FLIGHT . THE OVEN HAD BEEN OPERATING FOR APPROXIMATELY 30-40 MINUTES. THE SIC INSPECTED THE GALLEY AND OBSERVED ELECTRICAL BURNING ODOR COMING FROM THSDR CALA2026080918418Coffeemaker · faultedAT CRUISE AFT FA OBSERVED SMOKE COMING FROM COFFEE POT 419. FA PULLED CBS AND SMOKE SUBSIDED. NE EMERGENCY ACTIONS TAKEN. ATTENDING FA COMPLETED SMOKE AND ODOR REPORT. CONFIRMED SMOKE EMANATING FROM COFFEMAKER 419 WITH CORRESPONDING ELECTRICAL ODOR. REF LP 9SDR CALA2026080918394Coffeemaker · failedAFT GALLEY FA SMELLED SMOKE. FOUND COFFEEMAKER 403 CIRCUIT BREAKER TRIPPED & COFFEEMAKER CIRCUIT BOARD BURNED. NO DAMAGE TO GALLEY OR WIRING. ISOLATED TO COFFEE MAKER. OK TO APPLY MEL 2522Z. ACPD CONDITIONAL INSP OF AFT GALLEY POWER PANEL & AREA FOR CB 4SDR DALA2026081004614Oven · odorODOR OF STALE SMOKE DETECTED DURING TAXI TO THE GATE. R & R FWD GALLEY OVEN IAW AMM 25-31. OPS CHKD GOOD. R & R LT & RT RECIRC FILTERS IAW IAW AMM 21-25. (9096356) AIRCRAFT WAS GROUNDEDSDR AALA202608071587Oven · smokeAIRCRAFT WAS NOT GROUNDED: AFTER GALLEY OVEN 9B MADE A WOOSH SOUND AND SMALL PUFF OF ELECTRICAL SMELLING SMOKE ASSOCIATED CB TRIPPED. MAINTENANCE REPLACED 9B OVEN RESET CB OPS NORMAL PER AMM 25-32-00-10A-520A-A.SDR CALA2026080518329Oven · faultyOVEN 205 HAS A SMOKE ODOR, OVEN DEACTIVATED , CIRCUIT BREAKER OPEN, & COLLARD. OVEN PLACARDED. REMOVED AND REPLACED THE OVEN IAW AMM 25-34-00-400-801-C3. OPS CHKD NORMAL.SDR CALA2026080518327Oven · faultedGALLEY OVEN 305 HAS AN ELECTRICAL ODOR, OVEN DEACTIVATED, CIRCUIT BREAKER OPEN & COLLARD. OVEN PLACARDED. R & R THE OVEN IAW AMM 25-34-00-400-801-C3. OPS CHECKED GOOD.SDR AALA202608068557Module · defectiveAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN #2 TEMPERATURE RUNS VERY HIGH WITHIN MINUTES OF TURNING OVEN ON AND IS ACCOMPANIED BY A BURNT FOOD ODOR. MAINTENANCE REPLACED THE OVEN CONTROL MODULE PER AMM 25-35-00 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHSDR CALA2026080318209Oven · odorFA SAYS BURNT ELECTRICAL SMELL COMING FROM OVEN 204 FWD GALLEY WHILE COOKING FOOD PERFORMED OPS TEST OF OVEN. OPS CHK GOOD. NO DEFECTS FOUND. REF AMM 25-32-03-710-802.SDR AALA202608058622Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN 2 SMELLS LIKE BURNING PLASTIC. MAINTENANCE ACCOMPLISHED AN OPERATIONAL CHECK OF THE OVEN 3 TIMES FOR 30 MINUTES EACH TIME WITH NO ISSUES OR ODORS NOTED.SDR AALA202607300696Oven · smokeSMOKE EVENT IN GALLEY OVEN #2 DURING CRUISE FOR MAYBE 2 MINUTES. FA TURNED OFF OVEN, PULLED BREAKER, SMELL DISSIPATED. WHEN INSPECTED AFTER COOLING DOWN, IT WAS DETERMINED TO BE A PIECE OF CATERING TAPE STUCK TO A TRAY. OVEN MAY NEED TO BE CHECKED AND CLEANED SDR SWAA2026073145845Trash Bin · odorFLIGHT ATTENDANTS REPORT AN ELECTRICAL SMELL IN THE FWD GALLEY THAT WENT AWAY AFTER THE WORK LIGHT SWITCH WAS TURNED OFF PERFORMED FUME CONDITIONAL INSPECTION PER FIM 21-00 TASK 806. FOUND SMELL COMING FROM FWD GALLEY TRASH CAN. REMOVED TRASH BAG NO FURTHER MXSDR CALA2026072818065Oven · odorAFT GALLEY HAS A BURNED ODOR. REF TSM 05-50-00-810-831-A TYPE 10. INSPECTED AFT GALLEY CARTS, DUCTS, AND EQUIPMENT. FOUND LIGHT COFFEE STAINS ON WARMER, REMOVED. REMOVED GALLEY CARTS AND FOUND 2 FULL OF OLD FOOD WITH ODORS. REMOVED FOOD AND CLEANED CART INSDR AALA202607278212Warmer · odorAIRCRAFT WAS GROUNDED: AFTER TAKEOFF, BURNING SMELL SMELLED IN FORWARD GALLEY. BELIEVED TO ORIGINATE FROM OVEN WARMERS BEING LEFT ON. SMELL DISSIPATED QUICKLY. DECESION MADE TO DIVERT TO DUB, EMERGENCY DECLARED AS PRECAUTION AIRCRAFT LANDED WITHOUT INCIDENT. MSDR CALA2026072818062Oven · smokeSMOKE CAME OUT OF OVEN 204. OVEN TURNED OFF. SMOKE FIRE FUMES CHECKLIST PERFORMED. SMOKE DISSIPATED. SYSTEMS RESTORED. FLIGHT CREW SMOKE/ODOR QUESTIONAIRE OVEN 204 IS INOP DO TO SMOKE IN CABINE. OPEN CB, AND INOP DECAL. NOC.APPROVED NEF 2520P INOP OVEN 204 CB
Back to JASC 2530