Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202408298278Oven · dirtyAIRCRAFT WAS NOT GROUNDED: FLIGHT CREW REPORTED A STRONG PLASTIC ODOR EMINATING FROM OVEN #2. **SUPPLEMENTAL REPORT FOR AALA202408268278: MAINTENANCE CLEANED OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK WITH NO ODORS NOTED.** (CLOSED)SDR AALA202408268278Oven · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT CREW REPORTED A STRONG PLASTIC ODOR EMINATING FROM OVEN #2. (OPEN)SDR SWIA2024082000019Coffeemaker · smokeD: IN FLIGHT, FA REPORTS COFFEE MAKER MADE A SINGLE POPPING NOISE AND PUFF OF SMOKE. COFFEE MAKERS WERE ON AT THE TIME. (IB MKR)C: NEF-GAL-1CAT "C" DUE 08/29/2024IN FLIGHT, FA REPORTS COFFEE MAKER MADE A SINGLE POPPING NOISE AND PUFF OF SMOKE. COFFEE MAKERS WESDR YENA2024081901125Oven · dirtyFLT#887, BOS- LAX. 'WAVES OF ELECTRICAL / BURNING PLASTIC SMELL REPORTED BY INFLIGHT FWD GALLEY. TURNED OFF OVEN + COFFEE / ESPRESSO MAKER - SMELL CONTINUED. TURNED OFF GALLEY / CAB PUSH BUTTON AND SMELL DISSAPATED AND NEVER RETURNED; ACCOMPLISHED TSM 05-50-00SDR AALA202408192297Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY RIGHT (OUTBOARD) OVEN SMELLS BAD WHEN TURNED ON. REMOVED AND REPLACED #2 OVEN PER AMM 25-35-19.SDR AALA202408278995Oven · sparksAIRCRAFT WAS NOT GROUNDED: AFT GALLEY OVEN REPORTED SPARKING AND GIVING OFF ACRID ODORS. **SUPPLEMENTAL REPORT FOR (AALA202408208995): ACCOMPLISHED CONVECTION OVEN, OPERTIONAL TEST PER B787-A-25-32-00-17A-320A-A. NO DEFECTS NOTED**(CLOSED).SDR AALA202408208995Oven · sparksAIRCRAFT WAS NOT GROUNDED: AFT GALLEY OVEN REPORTED SPARKING AND GIVING OFF ACRID ODORS. **SUPPLEMENTAL REPORT WILL BE SUBMITTED**(OPEN).SDR DALA2024081908246Oven · smoke(LOG 6144034) GREY SMOKE FROM THE FORWARD GALLEY OVEN. OVEN UNPLUGGED AND CIRCUIT BREAKER PULLED. SMOKE DISIPATED. R+R FWD OVEN IAW B737 25-31. OPS CHECK GOOD.SDR DALA2024081308080Retainer · corrodedSHIP 3149 GALLEY G1 WORKDECK LOWER SKIN TROLLEY RETAINER AREA CORROSION. CORRECTIVE ACTION: REPAIRED PER ER/A # 619696-14. (0497584)SDR AALA202411051063Chiller · defectiveAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS REPORT THE AFT GALLEY CHILLER IS MAKING A LOUD NOISE AND BURNING RUBBER SMELL. THEY TURNED THE CHILLER OFF AND NOISE WENT AWAY BUT SMELL REMAINS. **SUPPLEMENTAL REPORT FOR AALA202408141063: MAINTENANCE REPLACED THESDR AALA202408141063Chiller · faultedAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS REPORT THE AFT GALLEY CHILLER IS MAKING A LOUD NOISE AND BURNING RUBBER SMELL. THEY TURNED THE CHILLER OFF AND NOISE WENT AWAY BUT SMELL REMAINS. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR AALA202408145998Oven · shortedAIRCRAFT WAS GROUNDED: FLIGHT ATTANDENT REPORTS NUMBER 2 OVEN CIRCUIT BREAKER POPPED WITH ELECTRICAL BURN SMELL.**SUPPLEMENTAL REPORT FOR (AALA202408095998): REMOVED AND REPLACED NUMBER 2 OVEN. OPERTIONAL CEHCK GOOD. PER AMM 25-32-03**(CLOSED).SDR DALA2024081308103Oven · smokeSHIP 3311 OVEN AT LOC 404 - PRODUCES SMOKE WHEN TURNED ON. CORRECTIVE ACTION: REPLACED OVEN PER A330 AMM 25-34. (0490556)SDR AALA202408095998Oven · faultedAIRCRAFT WAS GROUNDED: FLIGHT ATTANDENT REPORTS NUMBER 2 OVEN CIRCUIT BREAKER POPPED WITH ELECTRICAL BURN SMELL.**SUPPLEMENTAL REPORT WILL BE SUBMITTED**(OPEN).SDR DALA2024073007637Oven · odorSHIP 5049 - ATB - DUE TO REPORTS OF DIRTY SOCK AND FISH SMELL IN THE CABIN. CORRECTIVE ACTION: FOUND FORWARD GALLEY OVEN WITH A TERRIBLE SMELL. SUSPECT THIS COULD BE THE SOURCE OF THE FISH SMELL. REPLACED OVEN AND CLEANED CARPET BETWEEN ROWS 18 AND 21. (LP 046SDR DXTA2024072912476Oven · failedAFTER OVEN TEMP WAS SET TO 325 DEGREES, SMOKE EMITTED INTO GALLEY AND COCKPIT. IT HAD AN ELECTRICAL SMELL. THE OVEN & EXHAUST FAN WERE TURNED OFF IMMEDIATELY AND THE SMOKE CLEARED. STARTED GAINED ACCESS TO ATTACH SCREWS, AFT DETENT SET SCREW IS SEIZED IN PANESDR AALA202408142686Oven · odorAIRCRAFT WAS NOT GROUNDED: OVEN IN FIRST CLASS GALLEY HAS FOUL ODOR WHEN USED AS FOOD WAS LEFT IN IT WHILE AIRCRAFT WAS DOWN FOR MAINTENANCE AND HAD SPOILED. **SUPPLEMENTAL REPORT FOR AALA202407292686: MAINTENANCE CLEANED OVEN IN FIRST CLASS AND ACCOMPLISHED SDR AALA202407292686Oven · odorAIRCRAFT WAS NOT GROUNDED: OVEN IN FIRST CLASS GALLEY HAS FOUL ODOR WHEN USED AS FOOD WAS LEFT IN IT WHILE AIRCRAFT WAS DOWN FOR MAINTENANCE AND HAD SPOILED. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR CALA2024072402092Coffeemaker · contaminatedSMOKE IN CABIN. STRONG ODOR. NEED INSPECTION. FWD GALLEY AREA. PERFORMED SMOKE / ODOR IN THE CABIN CO NDITIONAL INSPECTION IAW AMM 05-51-26-800-801-C1. ONLY ITEM FOU ND WAS BURNT COFFEE ON FWD GALLEY COFFEEMAKER HOT PLATE. CLEANED HOT PLATE AS REQ''D AND BREWSDR DALA2024072207325Oven · contaminatedSHIP 3301 OVEN BURNING SMELL. CORRECTIVE ACTION: PER A330 AMM 25-35, R/R BOTH L AND RT OVENS. FOUND ASH UNDER EACH AND GREASY DEBRIS AT OVEN DOORS. ALL DEBRIS/ASH CLEANED. NO ARCHING OR BURN MARKS OR FURTHER DEFECTS NOTED. (0458873)SDR DALA2024072307410Oven · odor(LOG 0456533) PILOTS NOTICED MILD BURNING SMELL IN FD, CREW TRACED IT TO POSSIBLE ELECTRIC SMELL COMING FROM OVEN. R/R OVEN IN FWD GALLEY. REF. B737 AMM 25-31. OVEN OPS CHECK GOOD.SDR AALA202407196997Oven · overheatedAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: CREW REPORTS NUMBER 2 OVEN OVERHEATED; AIRCRAFT DIVERTED TO AND LANDED SAFELY AT TPA. PERFORMED OPERATIONAL TEST OF OVEN PER AMM 25-32-03, TEST PASSED. NO FAULT FOUND.SDR DALA2024071907290Oven · inoperative(LOG 5580584) WHEN FA WAS USING OVEN SHE REPORTED A VERY FAINT ELECTRICAL SMELL AND THAT THE OVEN QUIT WORKING. R/R OVEN REF AMM 25-35 OPS NML OK FOR SVC.SDR DALA2024071507133Coffeemaker · odorSHIP 3163 CARBON/PAPER BURNING SMELL IN AFT GALLEY & COMING FROM THE VENT AND CLOSE TO THE FA SEAT. CORRECTIVE ACTION: R/R TWO COFFEE MAKERS LOC 405 PER A319 AMM 25-35. OPS CHK NML. OK FOR SVC. (6009694)SDR QXEA2024071200173Oven · malfunctionedEVEN THOUGH THE AFT OVEN IS IN THE OFF POSITION, IT IS STILL PRODUCING HEAT REMOVED FROM SERVICE. PLACED ON DEFERRAL. (RESOLVED ON W/O: 342076 TASKCARD: N/R-00001 ) REPLACED AFT OVEN REF E175 AMM 25-37-02-000/400-803-A AND MCN E250052-001 ISSUE 1. OPS CHECK GOSDR DALA2024071507126Oven · inoperativeSHIP 3770 -SMK- FORWARD GALLEY OVEN OVERHEATED WITH SMOKE DURING CLIMB OUT. REMOVED POWER FROM OVEN. CORRECTIVE ACTION: REPLACED OVEN PER B737 AMM 25-31. OPS CHECK OK.SDR AALA202407125097Oven · odorAIRCRAFT WAS GROUNDED: OVEN 4 HAS ELECTRIC SMELL WHEN IN USE. REPLACED OVEN #4 PER CMM 25-30-012.SDR AALA202407122883Coffeemaker · odorAIRCRAFT WAS GROUNDED: DURING CRUISE FLIGHT ATTENDANT SMELLED ACRID/BURNING SMELL FROM AFT GALLEY FROM UNKNOWN SOURCE. FOLLOWED QUICK REFERENCE HANDBOOK AND SHED THE GALLEY & CAB VIA FLIGHT DECK PUSH BUTTON. THE SMELL STOPPED INCREASING AND SLOWLY DECREASED,SDR AALA202407124188Coffeemaker · odorAIRCRAFT WAS GROUNDED: DURING CRUISE FLIGHT ATTENDANT SMELLED ACRID/BURNING SMELL FROM AFT GALLEY FROM UNKNOWN SOURCE. FOLLOWED QUICK REFERENCE HANDBOOK AND SHED THE GALLEY & CAB VIA FLIGHT DECK PUSH BUTTON. THE SMELL STOPPED INCREASING AND SLOWLY DECREASED,SDR CALA2024071000190Oven · odorDUE REPORTED SMOKE AFT CABIN GALLEY AREA DURING T/O AND INITIAL CLIMB REF L/P 8553290 & 8553275 SHALL REQUIRE SMOKE OR FUMES IN CABIN -FIM BE ACCOMPLISHED PER DMC-B787-A-21-20-F5-72A-421A-A. I N ADDITION, PLEASE MEET INBND FLT DECK/CABIN CREW FOR DE-BRIEF A NDSDR AALA202407157148Chiller · defectiveAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT REPORTS LIGHT BURNING SMELL COMING FROM THE FORWARD CHILLER AT THE 1R DOOR AREA. MAINTENANCE REPLACED THE CHILLER AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-34-51.SDR YENA2024071100950Coffeemaker · odorFLT#39, FLL-SFO. 'INFLIGHT CREW REPORTED SMELL OF SOMETHING BURNING AROUND GALLEY OFF BUTTON ELIMINATED SMELL ( COFFEE MAKERS ).' (SUPPLEMENTAL INFORMATION TO FOLLOW)SDR AALA202407097148Chiller · odorAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT REPORTS LIGHT BURNING SMELL COMING FROM THE FWD CHILLER/1R DOOR AREA. OPENSDR DALA2024070806894Coffeemaker · failedAIRCRAFT 1008, UPON INITIAL START UP - COFFEE MAKER IN AFT GALLEY POPPED C/B 405 AND HAD PLASTIC BURNING SMELL. CORRECTIVE ACTION: REPLACED COFFEE MAKER. (LP 6197930)SDR DALA2024070806858Coffeemaker · odorSHIP 3118 - DIV - TO BNA FOR BURNING ELECTRICAL SMELL IN AFT GALLEY. CORRECTIVE ACTION: FOUND BURNED TOWEL BEHIND AFT INBOARD COFFEE MAKER (LOC. 401). REMOVED TOWEL AND PLACED COFFEE MAKER ON NEF DEFERRAL. LATER, REPLACED COFFEEMAKER. OK TO CONTINUE. (LP 58602SDR AALA202407050479Oven · odorAIRCRAFT WAS NOT GROUNDED: OVEN 1B IN FORWARD GALLEY SMELL OF BURNING BEHIND OVEN. MAINTENANCED REPLACED OVEN IAW AMM 25-32-00.SDR AALA202407030479Oven · odorAIRCRAFT WAS NOT GROUNDED: OVEN 1B IN FORWARD GALLEY SMELL OF BURNING BEHIND OVEN. (OPEN)SDR DALA2024070206720Oven · odor(LOG 6140434) FA REPORTS A BURNING SMELL IN AFT CABIN ON LANDING RECEIVED VERBAL FROM FA. NO GO ODI STEPS 1-4 C/W FOUND CB FOR OVEN NBR 2 CLOSED AND NOT COLLARED LIKE 1,2 . NO OVENS ONBOARD (654507).C/W NO GO ODI 2127 ALL STEPS GOOD. T/S PER B737 FIM 21-00 TASSDR AALA202407080065Oven · smokeAIRCRAFT WAS NOT GROUNDED: FIRST CLASS OVEN ON AIRCRAFT LEFT SIDE REPORTED TO BE SMOKING WHEN IN USE; FLIGHT ATTENDANT TURNED IT OFF AND USED OTHER OVEN. **SUPPLEMENTAL REPORT FOR AALA202407020065: MAINTENANCE REPLACED OVEN AND ACCOMPLISHED A SATISFACTORY OPERSDR DALA2024070306732Oven · smoke(LOG 5620218) GALLEY OVEN STARTED SMOKING IN FLIGHT. R/R OVEN PER B737 AMM 25-31, CKS GOOD.SDR AALA202407020065Oven · smokeAIRCRAFT WAS NOT GROUNDED: FIRST CLASS OVEN ON AIRCRAFT LEFT SIDE REPORTED TO BE SMOKING WHEN IN USE; FLIGHT ATTENDANT TURNED IT OFF AND USED OTHER OVEN. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR DALA2024062706560Oven · odorDIVERTED TO MIA DUE TO ODOR IN FLIGHT DECK AND FORWARD GALLEY. CORRECTIVE ACTION: REPLACED FORWARD GALLEY OVEN. OPS CHECK NORMAL.SDR AALA202406243517Unknown · odorAIRCRAFT WAS GROUNDED: FLIGHT ATTANDENT REPORT AN ODOR FROM AFT GALLEY DURING TAKEOFF AND CLIMB. ODOR AFFECTED NOSE AND THROAT AND REQUIRED MOVING AFT ROW PASSENGERS FORWARD. (OPEN).SDR CALA2024062000030Control Unit · unknownALL REAR GALLEY OVEN CIRCUIT BREAKERS POPPED DURING CLIMBOUT SETTING SDR FLAG. INSPECTED BEHIND CB PANEL NO SIGN OF ARCING OR ANY FAULTS T/S PER SSM 25-31-02-102, NO FAULTS FOUND, REMOVED AND REPLACED BOTH RIGHT ELCU S AS PRECAUTIONARY, REF AMM 25-31-03-404-0SDR AALA202406289454Chiller · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTED BURNING PLASTIC SMELL IN AFT GALLEY. FLIGHT ATTENDANT SUSPECTED COFFEE POT/MAKER AND SHUT IT OFF. MAINTENANCE FOUND THE AFT GALLEY CHILLER CIRCUIT BREAKER POPPED AND DE-ACTIVATED THE CHILLER. ***SUPPLEMENTALSDR AALA202406249454Chiller · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTED BURNING PLASTIC SMELL IN AFT GALLEY. FLIGHT ATTENDANT SUSPECTED COFFEE POT/MAKER AND SHUT IT OFF. MAINTENANCE FOUND THE AFT GALLEY CHILLER CIRCUIT BREAKER POPPED AND DE-ACTIVATED THE CHILLER. (OPEN)SDR DALA2024062006254Access Panel · corroded(LOG 0400834) CORROSION ON ACCESS PANELS OF GALLEY 4. ACCESS PANELS OF GALLEY 4 (2EAS) PN: 9354078-7 AND PN: 9354078-8 WAS FABRICATED AND INSTALLED PER ER/A NO. 618835-14 REV. ORIGINAL SECTION I: PERMANENT REPAIR AND PRI ER/A 618835-14 REV 0.SDR AALA202406189042Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY LEFT OVEN SMELLS LIKE BURNING PLASTIC. REMOVED AND REPLACED OVEN. PER AMM 25-32-03.SDR QXEA2024061800157Oven · odorFA REPORTS TOXIC BURNING SMELL FROM FWD GALLEY AFT OVEN. SMELL WAS ALSO DETECTED BY THE FLIGHT CREW. SMELL DISSIPATED WHEN OVEN WAS TURNED OFF. REMOVED FROM SERVICE. PERFORMED GVI OF AFT OVEN IN FWD GALLEY AND PERFORMED OPS TEST OF AFT OVEN IN FWD GALLEY REF ESDR CALA2024061700002Oven · sparksOVEN SMOKING OR SPARKING G4 GALLEY AFT LEFT OVEN HAS MELTED PLASTIC AROUND VENT CBN CREW REPORTED IT LOOKS LIKE ACTUALLY HEATED THE VINYL.REMOVED VINYL AND CLEANED OVEN INSIDE. OPE AND SMELL CHECK OK IAW AMM 25-34-00-201.
Back to JASC 2530