JASC 2530

Service difficulty reports · 4,469

Reports filed under 2530 · Buffet/Galleys, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2530'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA202402260413Oven · inoperativeAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVENS INOPERATIVE DUE TO SIGNIFICANT SMELL WHEN TURNED ON IN FLIGHT. REPLACED NUMBER 1 (AALA202402192379) AND NUMBER 2 (AALA202402260413) FORWARD GALLEY OVENS. PER AMM 25-32-03.Feb 16, 2024 · N336TM · Boeing 737823SDR AALA202402234304Microwave Oven · burnedAIRCRAFT WAS NOT GROUNDED: FA REPORTS BURN HOLES ON INSIDE OF MICROWAVE DOOR IN FORWARD GALLEY (LINING OF DOOR INSIDE) AND DISCOLORING OF OUTER PANE THAT CORRESPONDS WITH BURN HOLES ON INTERIOR OF DOOR. MAINTENANCE REPLACED MICROWAVE OVEN.Feb 16, 2024 · N728AN · Boeing 777323ERSDR GTIA2024022037923Counter · damagedREF SPIRIT W/O 299692 T/C TR 2533-015-1. G4 GALLEY WORKDECK REPLACEMENT. RAF-01 3499899-01 GENERATED.-G4 GALLEY WORKDECK REPLACED IAW EC 2533-015Feb 16, 2024 · N684NK · Airbus A321231SDR DALA2024022002342Oven · inoperative(LOG 5450478) LIGHT SMOKE AND SUTTLE METALLIC ELEC ODOR COMING FROM FWD GALLEY OVEN. RPLCD C/ AND REPAIRED WIRING REF B737 CMM 25-31-71 AND SWPM CH 20. RE INSTALLED PANEL AND REPLACED OVEN REF B737AMM 25-31. OVEN CHECKS NML.Feb 16, 2024 · N868DN · Boeing 737932ERSDR AALA202402192379Oven · inoperativeAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVENS INOPERATIVE DUE TO SIGNIFICANT SMELL WHEN TURNED ON IN FLIGHT. **SUPPLEMENTAL REPORT WILL BE SUBMITTED**(OPEN).Feb 16, 2024 · N336TM · Boeing 737823SDR SWAA2024021251032Coffeemaker · odorALL COFFEE POTS HAVE HEINOUS SMELL.<[01] OK TO CONTINUE PER MEL 38-10-01A; SP# 1B.<BR>AUTHORIZATION # 179270;[02] R&R ALL COFFEE POTS PER AMM 25-31-11.;[03] COMPLIED WITH TASK CARD 838-070-00-01. (WATER DISINFECT);[04] C/WFeb 10, 2024 · N1804U · Boeing 7378SDR AALA202402122101Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVENS HAD BURNING SMELL DURING FLIGHT. REMOVED AND REPLACED FORWARD GALLEY OVEN.Feb 10, 2024 · N738US · Airbus A319112SDR GTIA2024021037900Cart · odorVINEGAR SMELL ON APPROACH AT 3000".-APPLIED T.S.M. 05-50-00-810-831-A . UPON INSPECTION OF AC. FOUND AFT GALLEY CARTS AND TRASH CONTAINER DIRTY AND WET ( LIKE OLD JUICE RESIDUE) CLEANED AFT GALLEY AREA AS REQUIRED AND C/W AC. DECONTAMINATION OF THE ENVIROMEFeb 9, 2024 · N949NK · Airbus A320271NSDR DALA2024021302114Controller · failedFLIGHT ATTENDANT NOTICED BURNING PLASTIC SMELL BY DOOR 4R WHEN ON FINAL. FOUND FAULT CODE 2161F1FK HEATER ELEC AFT GALLEY (101HJ2), PERFORMED TCS BITE TEST PER TSM A350-A-21-61-XX-HN-001-421A-A AND TEST FAILED. ITEM DEFER TO MEL 21-60-11A. C/W (M) PROCEDURE. IFeb 8, 2024 · N505DN · Airbus A350941SDR AALA202402271955Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN 2 HAS BURNING PLASTIC SMELL WHEN IN USE. VERIFIED NO ITEMS IN OVEN WHEN DISCREPANCY NOTED. **SUPPLEMENTAL REPORT FOR AALA202402121955: MAINTENANCE REPLACED THE FORWARD GALLEY OVEN #2 PER AMM 25-35-19.** (CLOSED)Feb 7, 2024 · N658AW · Airbus A320232SDR AALA202402121955Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN 2 HAS BURNING PLASTIC SMELL WHEN IN USE. VERIFIED NO ITEMS IN OVEN WHEN DISCREPANCY NOTED. (OPEN)Feb 7, 2024 · N658AW · Airbus A320232SDR DALA2024020801751Coffeemaker · odorSHIP 676 DURING CRUISE AFT GALLEY COFFEE MAKER CIRCUIT BREAKER TRIPPED. FORWARD GALLEY LIGHTS FLICKERING. F/A REPORTS BURNING SMELL IN FWD GALLEY. CORRECTIVE ACTION: REPL AFT GALLEY COFFEEMAKER PER B757 AMM 25-31. CKS OK. FWD GALLEY LIGHTS CK OK PER B757 AMM 3Feb 6, 2024 · N676DL · Boeing 757232SDR SWAA2024020848408Coffeemaker · faultedF/A REPORTS FWD COFFE MAKER HAS A METALLIC SMELL AWHEN BREWED<[01] OK TO CONTINUE PER MEL 25-10-01 XB<BR>SP1B; SP2;[02] REMOVED AND REPLACED FWD COFFEE MAKER IAW AMM 25-30-01. OPS AND LEAK CHECK GOOD. SMELL/TASTE CHECK GOOD. THIS CLEARS MEL 25-10-01XB.Feb 3, 2024 · N8620H · Boeing 7378H4SDR DALA2024020601608Block · damagedSHIP 3124 WORKDECK ASSY WAS FOUND WITH SEVERAL DENTS AND CORROSION DAMAGE WAS FOUND IN THE TROLLEY RETAINER BLOCKS ON LOWER SKIN OF G1 FWD GALLEY. CORRECTIVE ACTION: REPAIRED PER ER/A 614688-14. (0185502)Feb 3, 2024 · N324NB · Airbus A319114SDR AALA202402059082Oven · smokeAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY RIGHT SIDE OVEN SMOKES WHEN USED. MAINTENANCE REPLACED OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.Feb 1, 2024 · N108UW · Airbus A320214SDR CALA2024020300308Oven · odorBURNING PLASTIC OR RUBBER ODOR IN AFT GALY. SMELL STOPD AFT OVN N CH LR OFF CHECKED AFT GALLEY CHILLERS AND OVENS. NO DEFECTS NOTED. UNABLE TO DUPLICATE DEFECT.Jan 30, 2024 · N74007 · Boeing 777224SDR AALA202401290885Coffeemaker · burnedAIRCRAFT WAS GROUNDED: SMELL DESCRIBED AS "BURNING PLASTIC" FROM NUMBER 4 COFFEE MAKER. REPLACED NUMBER 4 COFFEE MAKER. PER AMM 25-32-00. NO SMOKE ODOR DETECTED.Jan 28, 2024 · N850NN · Boeing 737823SDR AALA202401293905Oven · dirtyAIRCRAFT WAS NOT GROUNDED: FLIGHT CREW REPORTS NUMBER 1 OVEN BURNS FOOD. REMOVED AND REPLACED NUMBER 1 OVEN IN FORWARD GALLEY. PER AMM 25-32-03. OPERATIONAL CHECK GOOD.Jan 27, 2024 · N992AN · Boeing 737823SDR AALA202402272622Oven · odorAIRCRAFT WAS NOT GROUNDED: OVEN 1 IN FORWARD GALLEY SMELLS LIKE BURNT PLASTIC WHEN ON. **SUPPLEMENTAL REPORT FOR AALA202401262622: MAINTENANCE TURNED #1 OVEN ON FOR 1 HOUR AND NO PLASTIC OR OTHER DISTINGUISHING ODOR WAS NOTED. MAINTENANCE WAS UNABLE TO DUPLICAJan 22, 2024 · N153AN · Airbus A321231SDR AALA202401262622Oven · odorAIRCRAFT WAS NOT GROUNDED: OVEN 1 IN FORWARD GALLEY SMELLS LIKE BURNT PLASTIC WHEN ON. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)Jan 22, 2024 · N153AN · Airbus A321231SDR 2024F00015Oven · odorCREW DISCREPANCY REPORT (CDR) #1 FWD CABIN GALLEY OVEN SMELL OF BURNED PLASTIC WHEN IN USE (LEFT SIDE) LP27780. OEM: BUDERUS SELL GMBH GERMANYJan 22, 2024 · N802WA · Doug MD83SDR AALA202401226721Oven · fireAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: FIRE IN THE FORWARD GALLEY OVEN CAUSED SMOKE AND FUMES IN AIRCRAFT. AIRCRAFT DIVERTED AND LANDED SAFELY AT IAH WITHOUT FURTHER INCIDENT. ACCOMPLISHED JOB CARD 08L00021001. FIRE WAS INSIDE OVEN. NO DAMAGEJan 21, 2024 · N917AN · Boeing 737823SDR SWAA2024011842409Coffeemaker · burnedELECTRICAL SMELL IN AFT GALLEY. TURNED OFF COFFEE POTS AND GALLEY LIGHTS. SMELL WENT AWAY AND DID NOT RETUREN<[01] F/A NOTIFY ELECTRIC SMELL COMING FROM CAPT SIDE C/M AREA. FOUND ELECTRIC WIRE BURN MARKS FROM L/H AFT C/M RAIL ASSY . R/R L/H AFT COFFEE MAKER ANJan 18, 2024 · N8734Q · Boeing 7378SDR DALA2024011700730Oven · dirtySHIP 3317 LOCATIONS 404 MIDDLE OVEN STARTED SMOKING SND SPARKING WHEN TRYING TO HEAT UP HAMBURGER TOPS. WE CUT POWER, AIRED OUT THE GALLEY AND DID NOT USE THAT OVEN AGAIN. CORRECTIVE ACTION: INSPECTED MID GALLEY OVEN + FOUND COFFEE GRAINS ROASTED AND BURNED ATJan 13, 2024 · N817NW · Airbus A330323SDR DALA2024010800214Unknown · unknownSHIP 5008 FLIGHT ATTENDENTS REPORTED BURNING RUBBER/PLASTIC SMELL IN THE FWD GALLEY DURING TAKE-OFF. DISSIPATED WITH IN 2 MIN. CORRECTIVE ACTION: PLASTIC FOD IN OVEN. REPLACED OVEN. REPLACED RECIRC FILTERS. OK FOR SERVICE. (5600338) OVEN MPN: 1238C.Jan 7, 2024 · N508DA · Airbus A321271NSDR AALA202401096600Unknown · unknownAIRCRAFT WAS GROUNDED: FORWARD GALLEY IS REPORTED TO HAVE A STRONG SMELL OF SOLVENT OR DIRTY SOCK. (OPEN)Jan 6, 2024 · N990AU · Airbus A320*SDR SWAA2024012338285Shelf · corrodedG1 GALLEY IS CORRODED ON THE SHELF UNDER THE COFFEE MAKER<[01] PARTIALLY COMPLETED STEPS 1 AND 2.;[02] STEP 2: INSTALLATION(PARTIAL);[03] STEP 2: INSTALLATION(PARTIAL);[04] STEP 2 COMPLETE;[05] PARTIAL STEPS 1 AND 5;[06] REMOVED AND REPLACED G1 GALLEY IAW AMM Jan 5, 2024 · N423WN · Boeing 7377H4SDR DALA2024010800294Not Reported · not reportedSHIP 3120 CORROSION TROLLEY RETAINER BLOCK (1EA). CORRECTIVE ACTION: REPLACED PER ER/A # 613585-14. (0141525)Jan 5, 2024 · N320NB · Airbus A319114SDR DALA2024010800293Not Reported · not reportedSHIP 3120 CORROSION TROLLEY RETAINER BLOCK COMPARTMENT 112 FWD GALLEY ON FWD UTILITY AREA. CORRECTIVE ACTION: REPLACED PER ER/A 613585-14. (0141519)Jan 5, 2024 · N320NB · Airbus A319114SDR DALA2024010800224Oven · damaged(LOG 4303384) F/A NOTICED A BURNING RUBBER ODOR IN FWD GALLEY. THE OVEN WAS TURNED OFF AND THE ODOR DISSIPATED. FOUND FOOD ITEMS IN CONTAINERS AND ONE ITEM COVERED IN PLASTIC. R/R FWD GALLEY OVEN PER B737 AMM 25-31-88. OVEN OPERATES NORMAL.Jan 4, 2024 · N913DU · Boeing 737900ERSDR AALA202401087309Oven · smokeAIRCRAFT WAS NOT GROUNDED: AIRCRAFT RIGHT OVEN IN FORWARD GALLEY SMOKING DURING USE. **SUPPLEMENTAL REPORT FOR (AALA202401057309): REMOVED AND REPLACED OVEN 1 FORWARD RIGHT. PER AMM 25-32-03. OPERATIONAL CHECK OK**(CLOSED).Jan 3, 2024 · N916AN · Boeing 737823SDR AALA202401057309Unknown · unknownAIRCRAFT WAS NOT GROUNDED: AIRCRAFT RIGHT OVEN IN FORWARD GALLEY SMOKING DURING USE.**SUPPLEMENTAL REPORT WILL BE SUBMITTED**(OPEN).Jan 3, 2024 · N916AN · Boeing 737823SDR AALA202401105310Oven · smokeAIRCRAFT WAS GROUNDED: BURNING ELECTRICAL SMELL COMING FROM NUMBER 2 OVEN, BOTH IN AIR AND ON GROUND. **SUPPLEMENTAL REPORT FOR (AALA202401035310): REMOVED AND REPLACED BOTH #1 (AALA202401035310) AND #2 (AALA202401101527) FIRST CLASS OVENS. PER AMM 25-32-03 OVJan 1, 2024 · N926AN · Boeing 737823SDR AALA202401101527Oven · smokeAIRCRAFT WAS GROUNDED: BURNING ELECTRICAL SMELL COMING FROM NUMBER 2 OVEN, BOTH IN AIR AND ON GROUND. **SUPPLEMENTAL REPORT FOR (AALA202401035310): REMOVED AND REPLACED BOTH #1 (AALA202401035310) AND #2 (AALA202401101527) FIRST CLASS OVENS. PER AMM 25-32-03 OVJan 1, 2024 · N926AN · Boeing 737823SDR AALA202401035310Unknown · unknownAIRCRAFT WAS GROUNDED: BURNING SMELL JUST PRIOR TO DESCENT. FLIGHT ATTENDANT ADVISED NO.2 OVEN IN FORWARD GALLEY HAD SMOKE IN IT. ON THE GROUND OVEN STILL HAD SMOKE WITH ACCOMPANYING ELECTRICAL BURNING SMELL EVEN WITH OVEN SHUTOFFS. **SUPPLEMENTAL REPORT WILLJan 1, 2024 · N926AN · Boeing 737823SDR DALA2023122910720Unknown · unknownSHIP 3360 OVEN2 SPARKING ANDSMOKING DUE LEFT OVER CHOCOLATE IN OVEN. CORRECTIVE ACTION: OVEN DAMAGED UNABLE TO CLEAN REPLACED OVEN. (0129483)Dec 28, 2023 · N860NW · Airbus A330223SDR SWAA2024011937599Coffeemaker · corrodedCORROSION GALLEY 4 COFFEE MAKER DECK AT AFT GALLEY AREA 2023-766665<[01] ACCOMPLISHED EA 23-125-03777 (COMPONENT - AEM - REPAIR - GALLEY G4 COFFEE MAKER SHELF REPAIR. P/N 980004-1; S/N 025). TOOL USED SCALE: P/N CR5200; S/N 8343110878; DUE DATE: 21-FEB-24; HOTDec 19, 2023 · N457WN · Boeing 7377H4SDR AALA202312201563Oven · contaminatedAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTS THE NUMBER 2 OVEN IN FIRST CLASS GALLEY, HAS A VERY STRONG ODOR OF BURNING PLASTIC, WHEN TURNED ON.**SUPPLEMENTAL REPORT FOR AALA202312131563: REPLACED NUMBER 2 OVEN PER AMM 25-32-03.**(CLOSED)Dec 12, 2023 · N865NN · Boeing 737823SDR AALA202312131563Unknown · unknownAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTS THE NUMBER 2 OVEN IN FIRST CLASS GALLEY, HAS A VERY STRONG ODOR OF BURNING PLASTIC, WHEN TURNED ON.**SUPPLEMENTAL REPORT WILL BE SUBMITTED**(OPEN).Dec 12, 2023 · N865NN · Boeing 737823SDR J7SA2023120500379Coffeemaker · unserviceableAIR TURN BACK DUE TO VERY STRONG BURNING SMELL SHORTLY AFTER TAKEOFF. CREW DECLARED EMERGENCY AND LANDED SAFELY IN KSFB WHERE THEY EXITED 27 - R AND WERE MET BY EMERGENCY SERVICES. PERFORMED OPS CHECK FOR THE SMOKE/ABNORMAL SMELL IN THE CABIN/COCKPIT IAW PHENODec 4, 2023 · N377FX · Emb EMB505SDR DALA2023120409916Unknown · unknownSHIP 3149 G5 GALLEY FILLER ON WORK DECK TOP SIDE SECTION 512 CORRODED. CORRECTIVE ACTION: REPAIRED PER ERA 614027-14. (0092269)Dec 2, 2023 · N349NB · Airbus A319114SDR DALA2023120409920Unknown · unknownSHIP 3149 TROLLEY RETAINER BLOCK 512 HAS CORROSION. CORRECTIVE ACTION: REPLACED TROLLEY RETAINER BLOCK 512 ON WORK CARD 2530-01591-04D. (0090908)Dec 1, 2023 · N349NB · Airbus A319114SDR DALA2023120409919Unknown · unknownSHIP 3149 TROLLEY RETAINER BLOCK 511 HAS CORROSION. CORRECTIVE ACTION: REPLACED TROLLEY RETAINER BLOCK 511 ON WORK CARD 2530-01591-04D. (0090906)Dec 1, 2023 · N349NB · Airbus A319114SDR DALA2023120409918Unknown · unknownSHIP 3149 STABBING PROFILE HAS CORROSION. CORRECTIVE ACTION: REPLACED STABBING PROFILE ON WORK CARD 2530-01591-04D. (0090902)Dec 1, 2023 · N349NB · Airbus A319114SDR DALA2023120409917Unknown · unknownSHIP 3149 5/AFT GALLEY TROLLEY RETAINER BLOCK 510 HAS CORROSION. CORRECTIVE ACTION: REPLACED TROLLEY RETAINER BLOCK 510 ON WORK CARD 2530-01591-04D. (0090888)Dec 1, 2023 · N349NB · Airbus A319114SDR DALA2023120409909Oven · odor(LOG 9536000) BURNING ODOR FROM OVEN DURING CLIMB OUT. FA TURNED OFF OVEN & ODOR DISSAPATED. REMOVED AND REPLACED OVEN AT GALLEY LOC. 400 AND PERFORMED OERATIONAL TEST IN REF OF B737 AMM 25-31-88. OPS CHKD GOOD.Nov 29, 2023 · N897DN · Boeing 737900ERSDR AALA202311309792Oven · dirtyAIRCRAFT WAS NOT GROUNDED: OVEN 4 NEEDS TO BE CLEANED IT HAS A PLASTIC, BURNING SMELL WHEN IN USE. REMOVED AND REPLACED OVEN 4.Nov 29, 2023 · N117AN · Airbus A321231SDR SIMA20231127001Unknown · unknownFWD GALLEY RIGHT COFFEE POT CAUSED LAV SMOKE ALARM-C/A-EXAMINED AREA FOR EVIDENCE OF SMOKE SMELL, NONE DETECTED. TESTED FWD LAV SMOKE DETECTOR IAW AMM 26-14-01. TEST PASSED. R/H FWD GALLEY COFFEE MAKER OPS CHECK NORMAL IAW AMM 25-37-03Nov 27, 2023 · N299JJ · Emb ERJ170200LRSDR CALA2023112703490Oven · dirtyNUMBER 2 OVEN SMOKE PERFORMED CLEANING PROCEDURE OF GALLEY OVEN 2 AS PER AMM 25-32-03-100-801. OVEN STILL GIVING OUT SMOKE AFTER OPS CHECKING IT. (HEATING ELEMENT MOST LIKELY FAULTY) NEW OVEN NEEDED, PART NIS AT EWR. INSPECTED FWD GALLEY EQUIP PER FIM 21-00 TANov 26, 2023 · N17333 · Boeing 7378SDR DALA2023112809778Unknown · unknownSHIP 3361 GALLEY 406 OVEN SMOKES WHEN RUNNING. CORRECTIVE ACTION: R/R OVEN AT LOC 406. (0081195)Nov 25, 2023 · N861NW · Airbus A330223
Back to JASC 2530