Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202311273591Oven · dirtyAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS REPORTS BURNING SMELL FROM OVEN 1 IN FORWARD GALLEY. **SUPPLEMENTAL REPORT FOR (AALA202311243591): CLEANED AND OPERATIONAL CHECK ACCOMPLISHED. PER CMM 25-37-26.**(CLOSED).SDR AALA202311217058Oven · sparksAIRCRAFT WAS NOT GROUNDED: OVEN #2 IN FIRST CLASS GALLEY SPARKS WHEN TURNED ON & TIME KNOBIS MISSING. REMOVED AND REPLACED FWD GALLEY OVEN.SDR DALA2023111709493Unknown · unknownSHIP 3304 OVEN HAS SMOKE COMING FROM IT. OVEN CHECKED FOR RESIDUE BUT NONE FOUND. OVEN NUMBER 1 A318. CORRECTIVE ACTION: REMOVED AND REPLACED AFT GALLEY A318 OVEN. (0066388)SDR QXEA2023111700171Unknown · unknownFWD GALLY AFT OVEN CAUSED SMOKE. SUSPECT LEFTOVER FOOD CAUSED SMOKE. C/B PULLED. REMOVED FROM SERVICE. OVEN PLACED ON NEF. RETURNED TO SERVICE.SDR AALA202311298311Oven · defectiveAIRCRAFT WAS NOT GROUNDED: LEFT OVEN SMOKING WHEN TURNED ON. **SUPPLEMENTAL REPORT FOR AALA202311138311: MAINTENANCE REPLACED OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK. ** (CLOSED)SDR AALA202311138311Unknown · unknownAIRCRAFT WAS NOT GROUNDED: LEFT OVEN SMOKING WHEN TURNED ON. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR DALA2023110709151Unknown · unknownSHIP 3032 CORROSION UNDER WORKTABLE IN COMPARTMENT 112FR, 110 AND 111 IN GALLEY G1 FWD GALLEY AREA. CORRECTIVE ACTION: COMPLIED WITH ER/A 612946-14 REV ORIGINAL (0053157)SDR SCNA20231030243Unknown · unknownAFT OVEN EMITS CHEMICAL SMELL WHEN IN USE LT SIDE ( NON-ESSENTIAL EQUIPMENT AND FURNISHING (NEF) )SDR AALA202311036172Coffeemaker · leakingAIRCRAFT WAS NOT GROUNDED: AN EMERGENCY WAS DECLARED DUE TO WATER LEAK IN AFT GALLEY, TURNED WATER OFF CONTINUED TO LEAK. AIRCRAFT LANDED SAFELY AT CLT WITHOUT FURTHER INCIDENT. CHANGED COFFEE BREWER CARAFE ON UPPER COFFEE BREWER AFT GALLEY LEAK CHECK GOOD.SDR DALA2023110108997Unknown · unknownSHIP 3311 - FIRE/SMOKE - MID GALLEY OVEN CAUGHT ON FIRE DURING FLIGHT. CORRECTIVE ACTION: REPLACED OVEN. (0043446)SDR DALA2023103008896Unknown · unknownSHIP 3569 SMOKE FROM OVEN NBR 3. CORRECTIVE ACTION: R/R OVEN #3.SDR DXTA2023102698800Unknown · faultedDURING FLIGHT, WHILE USING THE MICROWAVE, THERE WAS AN AUDIBLE POP, THE MICROWAVE WENT DARK AND THERE WAS AN ELECTRICAL SMELL. AFTER LANDING THE MICROWAVE CB ON THE CES IS LOCKED, AND NONE OF THE OUTLETS IN THE GALLEY OR CREW REST AREA WORK. R&R THE ACPDE#5 DSDR DALA2024022902842Table · delaminatedSHIP 3256 A.D. RELATED AA2530-01591-01D. AFT GALLEY COMPARTMENT, DISBONDING FOUND ON LOWER SURFACE OF WORK DECK AT COMPARTMENTS 510, 511 AND 512. CORRECTIVE ACTION: COMPLIED WITH DELTA AMDS TASK CARD 2530- 01591-03D. (0023582)SDR REXA2024103001165Support · cracked"GALLEY WATER FILL LINE CLAMP SUPPORT CLIP IS CRACKED AND GUSSET IS CORRODED AT FS 349, STGR 21R. LOCATED AND DRILLED NEW FS 349 STGR 21R GUSSET IAW CRJ900 SRM 51-40-11-001-001-A01 AND FABRICATED/DRILLED NEW SUPPORT CLIP PER DRAWING NO. SH670-41519-3 FROM 20SDR AALA202310267623Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN EXCESSIVE ODOR AND SMOKE WHEN IN USE. **SUPPLEMENTAL REPORT FOR AALA202310167623: MAINTENANCE REPLACED OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.** (CLOSED)SDR AALA202310167623Unknown · unknownAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN EXCESSIVE ODOR AND SMOKE WHEN IN USE. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR DALA2023101608537Unknown · unknownSHIP 3139 G5 GALLEY WORKDECK TOP IS DAMAGED. CORRECTIVE ACTION: REPLACED WORKDECK TOP PER CMM 25-31-546. (0015811)SDR DALA2023101608536Unknown · unknownSHIP 3139 AFT. GALLEY COMPARTMENTS # 510, 511 AND 512 TROLLEY RETAINER BLOCKS SHOW EVIDENCE OF CRACKS / CORROSION. CORRECTIVE ACTION: CORRODED BLOCKS REPLACED ON CARD A320FAM 2530- 01591-04D. (0015804)SDR DALA2023101608535Unknown · unknownSHIP 3139 G5 GALLEY RETAINER CUPS CORRODED IN LOC 510, 511 AND 512. CORRECTIVE ACTION: REPLACE RETAINER CUPS PER CMM 683537-51011 25-31-543. (0015862)SDR DALA2023101608534Unknown · unknownSHIP 3139 G5 GALLEY TROLLEY RETAINER AND ROD ASSY'S IN LOC 510, 511 AND 512 ARE CORRODED. CORRECTIVE ACTION: REPLACED RETAINER PER CMM 25-31-543. (0015860)SDR AALA202310165379Coffeemaker · odorAIRCRAFT WAS NOT GROUNDED: FISRT CLASS GALLEY COFFEEMAKER GIVES OFF A BURNED COFFEE SMELL WHILE BREWING. MAINTENANCE REPLACED COFFEEMAKER AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202310132764Coffeemaker · odorAIRCRAFT WAS NOT GROUNDED: FIRST CLASS GALLEY COFFEEMAKER GIVES OFF A BURNED COFFEE SMELL WHILE BREWING. REPLACED G1 ESPRESSO MACHINE PER CMM 25-34-84.SDR AALA202310109668Oven · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS REPORTED OVEN NUMBER 2 WHEN TURNED ON, ELECTRICAL SMELL IS PRESENT. REMOVED AND REPLACED NUMBER 2 OVEN. PER AMM 25-32-03. FUNCTIONAL CHECK GOOD.SDR AALA202310132239Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN #2 UNUSABLE STRONG ELECTRICAL ODOR COMING FROM OVEN. **SUPPLEMENTAL REPORT FOR AALA202310122239: MAINTENANCE REPLACED THE OVEN PER AMM 25-35-19 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.** (CLOSED)SDR AALA202310122239Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN #2 UNUSABLE STRONG ELECTRICAL ODOR COMING FROM OVEN. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR AALA202310101528Chiller · shortedAIRCRAFT WAS GROUNDED: AFT GALLEY NUMBER 2 CHILLER CIRCUIT BREAKER POPPED, SLIGHT SMOKE SMELL. **SUPPLEMENTAL REPORT FOR AALA202310091528: AFT GALLEY NUMBER 2 CHILLER REPLACED. PER AMM 25-33-03. FUNCTIONAL CHECK GOOD.** (CLOSED)SDR DALA2023100908303Unknown · unknownSHIP 3142 AFT. GALLEY TROLLEY RETAINER BLOCKS SHOW SIGNS OF BULGING, CORROSION AND DELAMINATION IN COMPARTMENTS 510, 511, AND 512. CORRECTIVE ACTION: REPAIRED PER A.A WORK CARD 2530-01591-04D. (0007069)SDR SCNA20231011232Unknown · unknownAFT OVEN NEAR 2L DOOR F/A REPORTS WAS SMOKING AND SMELLED LIKE ELECTRICAL BURNING. STOPS AFTER OVEN SHUTOFF. OPS CHECKED #2 OVEN PER AMM 25-32-98. OPS CHECK GOOD. THIS CLEARS MEL.SDR AALA202310035340Oven · odorAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANTS REPORT A BURNING PLASTIC SMELL FROM GALLEY OVENS. MAINTENANCE FOUND THE FORWARD LEFT HAND OVEN TO HAVE A BURNT SUBSTANCE ON BOTTOM OF THE OVEN AND REPLACED IT PER AMM 25-35-19. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMSDR DALA2023100208070Unknown · unknownSHIP 3163 AFT. GALLEY TROLLEY RETAINER BLOCKS SHOW SIGNS OF BULGING AND CORROSION IN COMPARTMENTS 510, 511, AND COMPARTMENT 512 IS DIS-BONDED. CORRECTIVE ACTION: REPAIRED PER A.A. WORK CARD 2530-01591-04D. (2993589)SDR DALA2023100208077Unknown · unknownGALLEY OVEN #2, ELECTRICAL ODOR WHEN HEATING. REPLACED THE GAIN 2 OVEN IN GALLEY 403.SDR SWAA2023092805134Unknown · unknownFLIGHT ATTENDANT REPORTED FAINT SMELL ENROUTE FROM LAS-LAX AND SAID IT WAS GONE. ON FINAL APPROACH AND CLEARING THE RUNWAY WE GOT A CALL BACK THAT IT SMELL LIKE A RAGING FIRE BUT NO SMOKE. ARF (FIRE) WAS CALLED ON TAXIWAY AND DID INSPECTION. SAID THERE WERE NOSDR DALA2023092607932Unknown · unknownG4 GALLEY COMPARTMENT #412 HAS AREA SHOWS SMALL DELAMINATION LESS THEN 9"X3" REF. FCN 30-0525-8-0605 / WORK CARD 2530-01591- 01B A/D. SCEPTRE LOG PAGE ENTERED FOR SDR REPORTING. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 003-0001:2530-01591-01B/001 00001 C/W ONSDR AALA202309261421Oven · odorAIRCRAFT WAS NOT GROUNDED: FIRST CLASS GALLEY NUMBER 1 OVEN REPORTED TO HAVE CHEMICAL ODOR WHEN IN USE. REMOVED AND REPLACED NUMBER 1 OVEN. PER AMM 25-32-00.SDR AALA202309258992Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN #110 LEFT SIDE SMELLS TOXIC AND IS NOT HEATING PROPERLY. MAINTENANCE REPLACED OVEN PER AMM 25-35-15.SDR AALA202309194530Oven · odorAIRCRAFT WAS GROUNDED: WHEN OVEN ON BURNING SMELL. REPLACED FORWARD GALLEY #2 OVER PER AMM 25-32-02.SDR AALA202309187844Oven · odorAIRCRAFT WAS NOT GROUNDED: BURNT SMELL COMING FROM RIGHT OVEN IN FORWARD GALLEY. MAINTENANCE REPLACED RIGHT FORWARD GALLEY OVEN PER AMM 25-35-19.SDR SWAA2023091499498Coffeemaker · smokeFWD COFFEE MAKER SMELLS OF ELECTRIC OZONE TYPE ODER. NO SMOKE NOTED<[01] REMOVED AND REPLACED FWD COFFEE MAKER REF. AMM 25-30-01 OPS AND LEAK CHECK GOODSDR AALA202309139985Oven · smokeAIRCRAFT WAS NOT GROUNDED: GALLEY 1 NUMBER 2 OVEN HAS SMOKING BURNING SMELL. REMOVED AND REPLACED NUMBER 2 OVEN PER AMM 25-11-21.SDR AALA202309112449Oven · odorAIRCRAFT WAS GROUNDED: FORWARD GALLEY OVEN #1 HAS A BURNING AND EXHAUST ODOR DURING OPERATION. REMOVED AND REPLACED FORWARD GALLEY #1 OVEN PER AMM 25-32-03.SDR DALA2023091407572Unknown · unknownSHIP 3143 G5 GALLEY STABBING COVER PLATE CORRODED. CORRECTIVE ACTION: REPAIRED PER ER/A 611882-14. (2966276)SDR AALA202309071586Oven · odorAIRCRAFT WAS NOT GROUNDED: NUMBER 1 OVEN IN FORWARD GALLEY HAS A MILD ELECTRICAL BURNING SMELL. REMOVED AND REPLACED NUMBER 1 OVEN. PER AMM 25-32-02.OPS.SDR AALA202309010024Coffeemaker · defectiveAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY COFFEE MAKER SMELLS OF MELTED PLASTIC WITH LIGHT SMOKE WHEN BREWING. MAINTENANCE REPLACED THE #1 (AALA202309017747) AND THE #2 (AALA202309010024) COFFEEMAKERS IN THE FORWARD GALLEY PER AMM 25-35-15. A SATISFACTORY OPERSDR AALA202309017747Coffeemaker · defectiveAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY COFFEE MAKER SMELLS OF MELTED PLASTIC WITH LIGHT SMOKE WHEN BREWING. MAINTENANCE REPLACED THE #1 (AALA202309017747) AND THE #2 (AALA202309010024) COFFEEMAKERS IN THE FORWARD GALLEY PER AMM 25-35-15. A SATISFACTORY OPERSDR CALA2023090602732Oven · fireMID GALLEY OVEN HAD A FIRE NOW EXTINGUISHED LOCKING LOG UNLOCKING TO CLEAR LOG NO FIRE OCCURRED. SMOKE CAME FROM SPILLED CHOCOLATE OVERFLOWING IN OVEN. CHOCOLATE COKED ON THE INSIDE OF OVEN. NO EXTERNAL DAMAGE TO GALLEY. FIRE EXTINGUISHER USED IN OVEN. OVEN NOSDR DALA2023090107138Unknown · unknownSHIP 3265 FWD GALLEY OVEN FLASHED/SPARKED ON LANDING THEN THE SMELL OF BURNING. CORRECTIVE ACTION: R/R OVEN PER A320 AMM 25-34. OK FOR SERVICE. (4521608)SDR AALA202308298084Oven · odorAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT REPORTED SMOKE SMELL IN FORWARD GALLEY DURING DESCENT WHICH DISAPATED AFTER THE BREAKERS WERE PULLED. MAINTENANCE REPLACED THE #1 OVEN PER AMM AMM 25-33-00.SDR AALA202308291555Oven · smokeAIRCRAFT WAS NOT GROUNDED: BUSINESS CLASS OVEN #3 TOO HOT ON LOW SETTING, MELTED ITEMS OUTSIDE OVEN AND SMOKED WHEN ON. REPLACED #3 OVEN PER AMM 25-35-19 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202308295434Coffeemaker · odorAIRCRAFT WAS GROUNDED: THE AIRCRAFT RETURNED TO JFK DUE TO A STRONG BURNING ELECTRICAL SMELL COMING FROM THE FORWARD GALLEY. MAINTENANCE REPLACED THE CAPPUCCINO MAKER PER CMM 25-34-84 (AALA202308295434) AND THE COFFEE MAKER PER AMM 25-35-15. (AALA202308290504)SDR AALA202308290504Coffeemaker · odorAIRCRAFT WAS GROUNDED: THE AIRCRAFT RETURNED TO JFK DUE TO A STRONG BURNING ELECTRICAL SMELL COMING FROM THE FORWARD GALLEY. MAINTENANCE REPLACED THE CAPPUCCINO MAKER PER CMM 25-34-84 (AALA202308295434) AND THE COFFEE MAKER PER AMM 25-35-15. (AALA202308290504)
Back to JASC 2530