Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2023082907009Unknown · unknownFAULT CODE NE253402. DURING CLIMBOUT FLT ATT REPORTED AN ELECTRICAL BURNING SMELL FROM THE FWD GALLEY OVEN. THE F/A TURNED THE OVEN OFF AND THE ODOR DISSAPATED QRH WAS DONE PER MEL C/BS WERE PULLED BY FA. PERFORMED INSPECTION OF FWD GALLEY AREA. NO OTHER DEFECSDR GTIA2023082437435Structure · corrodedDURING HMV FOUND CORROSION ON FWD GALLEY. MDL 100MM MDW 135MM MDD 2MM OST 2MM RAF 3329126-01 CREATED.-VERIFIED NR # 5001256442-0010 AND 1004054579-0010. REPAIR HAS BEEN ACCOMPLISHED AS PER SPIRIT EA 2531-2339 REV 00.SDR ASAA2023081444599Unknown · unknownFORWARD LOWER COFFEE MAKER LEAKING WATER ONTO GALLEY FLOOR IN FLIGHT. LEAK UNCONTROLLABLE WITH VALVE TURNED OFF. GROUNDED - YES. DIVERSION -- REF: L/P #60571445. UPON ARRIVAL TO A/C NO LIQUID ON FLOOR. OPENED ALL FWD GALLEY CABINETS VERIFIED ALL DRY NO LIQUID SDR DALA2023081506652Unknown · unknownWARM RUBBERY SMELL AROUND DOOR 4L. NO ABNORMAL INDICATIONS AND ALL SYSTEMS NORMAL. TURNED OFF AFT COFFEE MAKERS AND PULLED CB'S . SMELL DISSAPEARED. C/W STEP 19 OF WORK CARD 0550-2002. FOUND NO EVIDENCE OF ARCHING /BURNT ELECTRICAL CONNECTORS/WIRES. AFT CARGO SDR AALA202308150844Oven · odorAIRCRAFT WAS GROUNDED: #1 OVEN HAS BURNING ELECTRIC SMELL WHEN USING. REMOVED AND REPLACED #1 OVEN PER AMM 25-35-19.SDR DALA2023081106577Unknown · unknownSHIP 3144 AD NOTED DELAMINATION BOTTON OF THE GALLEY 511 5X11. CORRECTIVE ACTION: REPAIRED DELAMINATION AT BOTTOM OF THE GALLEY 511 5X11 PER AD 2022-24-05. (2911357)SDR DALA2023081106575Unknown · unknownSHIP 3144 ON COMPARTMENT 510 FOUND DELAMINATION NOTED BOTTOM OF GALLEY 6X1. CORRECTIVE ACTION: REPAIRED DELAMINATION FOUND ON COMPARTMENT 510 NOTED BOTTOM OF GALLEY 6X11 PER AD 2022-24-05. (2911389)SDR DALA2023081106574Unknown · unknownSHIP 3144 AD NOTED DELAMINATION BOTTON OF GALLEY 512 11X4. CORRECTIVE ACTION: REPAIRED DELAMINATION BOTTOM OF GALLEY 512 PER AD 2022-24-05. (2911381)SDR AALA202308111935Oven · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTED ELECTRICAL ODOR WHEN OPERATING FIRST CLASS GALLEY OVEN #2. ODOR DISSIPATED WHEN OVEN TURNED OFF. MAINTENANCE REPLACED OVEN PER AMM 25-35-19 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR SCNA20230809207Unknown · unknownDEFECT 770498: AFT LEFT OVEN 410 DEGREES SMOKING WHEN USED. - - - RESOLUTION: REMOVED AND REPLACED AFT L/H OVEN REF AMM 25-31-01, OPS CHECK GOOD.SDR AALA202308071439Oven · odorAIRCRAFT WAS GROUNDED: PASSENGER AND FLIGHT ATTENDANT SMELT BURNING RUBBER AT ROW 3 THROUGH 12. FLIGHT CREW TURNED PED SWITCH ABOVE FLIGHT ATTENDANT PANEL OFF AND SMELL WENT AWAY. MAINTENANCE REPLACED FORWARD GALLEY RIGHT HAND OVEN PER AMM 25-35-19 AND ACCOMPLSDR DALA2023080806474Unknown · unknownSHIP 1606 AFT GALLEY OVEN #1 FA WHILE LOADING A MEAL A SPARK AND A FLAME. IMMEDIATLEY CLOSED DOOR AND TURNED OFF OVEN, FLAME WENT OUT. NO SMOKE OR FUMES NOTED. BACK OF OVEN APPEARS BURNT. CORRECTIVE ACTION: REMOVED AND REPLACED OVEN #1 POSITION IN AFT GALLEY RSDR AALA202308083244Coffeemaker · malfunctionedAIRCRAFT WAS NOT GROUNDED: COFFEE MAKER PANEL IS HOT WHEN IN USE. FLIGHT ATTENDANT 1 AND 3 SMELL BURNED RUBBER WHEN IN USE. USED SPARINGLY. REMOVED AND REPLACED COFFEE MAKER #2.SDR DALA2023080706397Oven · inoperative(LOG 4912860) OVEN SMELLED LIKE SMOKE AND SHUT OFF. NO CB POPED AND WILL NOT TURN BACK ON. REPLACED OVEN REF B737 AMM 25-31.SDR AALA202308015059Coffeemaker · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTED BURNING PLASTIC SMELL IN AFT GALLEY BEFORE LANDING. ACCOMPLISHED WORK CARD 08L0021001. NUMBER 4 COFFEE MAKER SHOW SIGNS OF BURN. **SUPPLEMENTAL REPORT FOR AALA202307315059: REPLACED COFFEE MAKER NUMBER 4 PESDR AALA202307315059Unknown · unknownAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTED BURNING PLASTIC SMELL IN AFT GALLEY BEFORE LANDING. ACCOMPLISHED WORK CARD 08L0021001. NUMBER 4 COFFEE MAKER SHOW SIGNS OF BURN. **SUPPLEMENTAL REPORT WILL BE SUBMITTED.** (OPEN)SDR AALA202308015261Oven · odorAIRCRAFT WAS GROUNDED: FORWARD GALLEY RIGHT OVEN PRODUCING BURNING PLASTIC SMELL WHEN OFF. MAINTENANCE REPLACED #2 OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR SWAA2023072883440Coffeemaker · smokeF/A IN AFT GALLEY SMELLED A BURNING ODOR THAT CAME AND WENT AWAY 3 TIMES. NO SMOKE WITH SMELL NOTED ODOR CAME FROM SMALL VENT JUST ABOVE FLOOR LEVEL ON RT SIDE OF AFT GALLEY. PERFORMED CONDITIONAL INSPECTION SMOKE OR FUMES IN THE CABIN PER FIM 21-00 TASK 806 &SDR DALA2023072506019Unknown · unknownSHIP 3306 OVEN SMOKING AT LOCATION 404. CORRECTIVE ACTION: R&R OVEN AT LOC 404. (2880270)SDR CALA2023071902278Oven · inoperativeSMOKE FROM OVEN 410. OVEN TURNED OFF CB PULLE D. OVEN SMOKE DUE TO SPILLED FOOD . PLACED ON MEL. COMP. WITH MEL OVEN INOPED. NOC DESK: 777 NAME: DOUG DATE: 17-JUL-23- MID GALLEY OVEN 410 - NEF 2520AV PLEASE DO NOT USE TILL OVEN IS REPLACED. RTBL FOR SMOLE ISDR DALA2023101208385Unknown · unknown(LOG 2858868) DURING ACCOMPLISHMENT OF EO 2530-01593, DISCREPANCIES WERE FOUND WITHIN THE WORK CARDS. ACCOMPLISH VA 97784MA REV IR IN CONJUNCTION WITH EO 2530-01593.SDR AALA202307135547Oven · defectiveAIRCRAFT WAS NOT GROUNDED: OVEN #4 COOKS SLOWLY, SOME SMOKE. REPLACED OVEN PER AMM 25-35-19.SDR AALA202307109572Coffeemaker · odorAIRCRAFT WAS GROUNDED: ALL 4 FLIGHT ATTENDANTS REPORT A FUME/SMELL FROM AFT GALLEY AT CRUISE. SMELLS LIKE A BURNT MENTHOL CIGARETTE SLIGHTLY WITH ASH OR CHEMICAL SMELL ONLY IN AFT GALLEY AREA WHEN TURNING ON THE COFFEEMAKERS TO BREW COFFEE. MAINTENANCE REPLACESDR AALA202307102832Coffeemaker · odorAIRCRAFT WAS GROUNDED: ALL 4 FLIGHT ATTENDANTS REPORT A FUME/SMELL FROM AFT GALLEY AT CRUISE. SMELLS LIKE A BURNT MENTHOL CIGARETTE SLIGHTLY WITH ASH OR CHEMICAL SMELL ONLY IN AFT GALLEY AREA WHEN TURNING ON THE COFFEEMAKERS TO BREW COFFEE. MAINTENANCE REPLACESDR AALA202307107637Drain Line · leakingAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAT RETURNED TO CLT. FLIGHT ATTENDANTS REPORTED SOUR/ ROTTING SMELL AND VISIBLE HAZE SMOKE AT 2R DOOR, 4 ROWS OF SEAT FOWARD AND AFT. THE AIRCRAFT LANDED SAFELY AT CLT WITHOUT FURTHER INCIDENT. MAINTSDR AALA202307073961Oven · odorAIRCRAFT WAS GROUNDED: JUST AFTER TAKE OFF, FLIGHT ATTENDANT REPORTS STRONG ODOR OF BURNING RUBBER. ODOR CONTINUED ON AND OFF DURING CRUISE, AND RETURNED JUST BEFORE LANDING. ODOR ONLY IN FORWARD GALLEY. MAINTENANCE FOUND THE FORWARD GALLEY #1 OVEN TO BE THE SSDR AALA202308039428Oven · odorAIRCRAFT WAS GROUNDED: FAINT BURNING SMELL IN COCKPIT ASSOCIATED WITH FORWARD GALLEY RIGHT OVEN ON HIGH IT DISSIPATED WITHIN FIVE MINUTES OF TURNING OVEN OFF. **SUPPLEMENTAL REPORT FOR AALA202307109428: MAINTENANCE REPLACED THE OVEN PER AMM 25-35-19 AND ACCOMPSDR AALA202307109428Oven · odorAIRCRAFT WAS GROUNDED: FAINT BURNING SMELL IN COCKPIT ASSOCIATED WITH FORWARD GALLEY RIGHT OVEN ON HIGH IT DISSIPATED WITHIN FIVE MINUTES OF TURNING OVEN OFF. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR AALA202308032698Oven · defectiveAIRCRAFT WAS GROUNDED: ABOUT 30 MINUTES INTO FLIGHT THE FLIGHT ATTENDANTS REPORTED SMOKE AND ELECTRICAL SMELL FROM OVEN 9C IN AFT GALLEY . OVEN DID NOT TURN OFF UNTIL AFT GALLEY MASTER POWER SWITCH WAS TURNED OFF. MAINTENANCE FOUND OVEN FAULT CODES F21 AND F02SDR AALA202308033263Oven · odorAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT REPORT A SOUR SMELL COMING FROM THE AIR VENTS ON TAKEOFF AND LANDING. MAINTENANCE DETERMINED THE FORWARD GALLEY #1 OVEN WAS THE SOURCE OF THE ODOR. **SUPPLEMENTAL REPORT FOR AALA202307053263: MAINTENANCE REPLACED OVEN PESDR AALA202307053263Oven · odorAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT REPORT A SOUR SMELL COMING FROM THE AIR VENTS ON TAKEOFF AND LANDING. MAINTENANCE DETERMINED THE FORWARD GALLEY #1 OVEN WAS THE SOURCE OF THE ODOR. **SUPPLEMENTAL REPORT WILL BE SUBMITTED**(OPEN)SDR AALA202307032698Oven · defectiveAIRCRAFT WAS GROUNDED: ABOUT 30 MINUTES INTO FLIGHT THE FLIGHT ATTENDANTS REPORTED SMOKE AND ELECTRICAL SMELL FROM OVEN 9C IN AFT GALLEY . OVEN DID NOT TURN OFF UNTIL AFT GALLEY MASTER POWER SWITCH WAS TURNED OFF. MAINTENANCE FOUND OVEN FAULT CODES F21 AND F02SDR AALA202308030626Oven · defectiveAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTS OVEN BURNS FOOD TO A CHAR. A LITTLE BIT OF BLACK SMOKE. OVEN WAS SHUT OFF A NOT USED FOR REMAINDER OF THE FLIGHT. **SUPPLEMENTAL REPORT FOR AALA202307030626: MAINTENANCE REPLACED OVEN PER AMM 25-33-00 AND ACCSDR AALA202307055764Oven · defectiveAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY #2 OVEN HAD ODOR DURING USE. REPLACED OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202307030626Oven · defectiveAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTS OVEN BURNS FOOD TO A CHAR. A LITTLE BIT OF BLACK SMOKE. OVEN WAS SHUT OFF A NOT USED FOR REMAINDER OF THE FLIGHT. **SUPPLEMENTAL REPORT WAS SUBMITTED**(OPEN)SDR AALA202306300062Coffeemaker · defectiveAIRCRAFT WAS GROUNDED: DURING CRUISE FLIGHT ATTENDANTS REPORTED AN ODOR SIMILAR TO BURNT PLASTIC IN AREA OF AFT GALLEY. IFLIGHT ATTENDANTS TURNED OFF AFT GALLEY COFFEE MAKERS AND ODOR DISSPATED. MAINTENANCE REPLACED AFT GALLEY COFFEE MAKER #3 (AALA202306300062SDR AALA202306300851Coffeemaker · defectiveAIRCRAFT WAS GROUNDED: DURING CRUISE FLIGHT ATTENDANTS REPORTED AN ODOR SIMILAR TO BURNT PLASTIC IN AREA OF AFT GALLEY. IFLIGHT ATTENDANTS TURNED OFF AFT GALLEY COFFEE MAKERS AND ODOR DISSPATED. MAINTENANCE REPLACED AFT GALLEY COFFEE MAKER #3 (AALA202306300062SDR AALA202306283542Oven · defectiveAIRCRAFT WAS NOT GROUNDED: DURING FLIGHT THE FLIGHT ATTENDANT WAS USING THE FORWARD GALLEY #2 OVEN AND WHEN THE OVEN DOOR WAS OPENED SMOKE WAS VISIBLE BUT NO FIRE WAS NOTED. THE FLIGHT ATTENDANT TURNED OFF THE OVEN AND LOCKED IT TO PREVENT FURTHER USE. MAINTENSDR AALA202306132922Oven · odorAIRCRAFT WAS GROUNDED: DURING DESCENT, BURNING SMELL. IN COCKPIT AND CABIN. MAINTENANCE FOUND FOOD DEBRIS IN FORWARD GALLEY LEFT HAND OVEN. CLEANED AND RAN OVEN. NO DEFECTS OR SMELL NOTED.SDR AALA202306078593Unknown · unknownAIRCRAFT WAS NOT GROUNDED: FIRST CLASS GALLEY CHILLER BECAME VERY HOT AND PRODUCED BURNING ODOR. CREW TURNED OFF CHILLER. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR AALA202306060021Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY RIGHT OVEN HAS BURNING PLASTIC SMELL WHEN IN USE. MAINTENANCE REPLACED OVEN AND ACCOMPLISHED A SATISFACTORY OPERAIONAL CHECK.SDR AALA202306050572Oven · odorAIRCRAFT WAS GROUNDED: HOT SMELL FROM OVENS IN AFT GALLEY. MAINTENANCE FOUND OVENS 9C AND 9D AS ODOR SOURCE. REPLACED OVEN 9C (AALA202306050572) AND OVEN 9D (AALA202306054257) PER AMM 25-33-00.SDR AALA202306054257Oven · odorAIRCRAFT WAS GROUNDED: HOT SMELL FROM OVENS IN AFT GALLEY. MAINTENANCE FOUND OVENS 9C AND 9D AS ODOR SOURCE. REPLACED OVEN 9C (AALA202306050572) AND OVEN 9D (AALA202306054257) PER AMM 25-33-00.SDR YENA2023060100571Unknown · unknownFLT#1957, FLL-BOG. 'ONCE A/C WAS BUTTON UP THE INFLIGHT CREW NOTICED A STRONG ELEC SMELL COMING FROM THE AFT VENT.' (SUPPLEMENTAL INFORMATION TO FOLLOW)SDR AALA202305308824Coffeemaker · odorAIRCRAFT WAS GROUNDED: AFT GALLEY COFFEEMAKER #2 PRODUCES BURNING PLASTIC SMELL, PULLED COFFEE CIRCUIT BREAKER AND SMELL WENT AWAY. MAINTENANCE REPLACED COFFEMAKER PER AMM 25-32-00.SDR DALA2023052404137Unknown · unknownSHIP 3311 - SMKE - DUE TO MID GALLEY COFFEE MAKER GENERATING ELECTRICAL SMELL AND REQUIRING CIRCUIT BREAKER TO BE PULLED. CORRECTIVE ACTION: VISUALLY INSPECTED CONNECTORS AND WIRING AROUND COFFEE MAKER. ALL CONNECTORS AND WIRING CHECK GOOD. ELECTRICAL SMELL NASDR FDEA202305220915Oven · failedPDIS 894 25-30 4173 22MAY23 ANC ACRID SMELL COMING FROM OVEN AREA. TURNED OVEN OFF AND NO MORE SMELL. NEEDS TROUBLESHOOTING. FACT 22MAY23 17:57 ANC REMOVED OVEN WITH THE STANK, REPLACED WITH NEW OVEN REF B777 AMM 25-32-52-4-2 OPS CHECK GSDR AALA202305253206Oven · defectiveAIRCRAFT WAS NOT GROUNDED: FORWARD OVEN #1 CAUSES SMOKE TO FORM IN THE CABIN WHEN USED. REPLACED OVEN PER AMM 25-35-19 AND ACCOMPLISHED A SATISFACTIORY OPERATIONAL CHECK.SDR GTIA2023052237203Galley · damagedG4 GALLEY WORKDECK DISBONDED. RAF 01 CREATED-ACCOMPLISHED TEMP REPAIR OF G4 GALLEY WORK DECK PER RDAF 81224907/016/2023#A CAT C REPAIR LIFE LIMIT 12 MO. FROM EMBODIEMENTSDR SWAA2023051749489Coffeemaker · burnedFAS REPORT ELECTRICAL SMELL IN AFT GALLEY AREA. IN FLIGHT FA IN AFT REPORTED AN ELECTRICAL SMELL. I ASKED HER TO CHECK LAVS AND TURN OFF COFFEE POTS. CHECK FOR ANY OTHERS SIGNS OF SMOKE/OR FIRE. ONE MINUTE LATER FA REPORTED IT HAD GONE AWAY ON SHORT FINAL FAS
Back to JASC 2530