Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2020111229541Coffeemaker · faultyAFT COFFEE MAKER OMITTING ELECTRICAL ODOR. R & R BOTH COFFEE MAKERS, PER AMM 25-30-01 CL 58775 P1-ICT 651594 P2-ICT 651587. PN 416-0001-9 1 SN OFF 4535 SN ON 4641 2 SN OFF 01M9208010005 SN ON 0568.SDR SWAA2020111229542Coffeemaker · faultyAFT COFFEE MAKER OMITTING ELECTRICAL ODOR. R & R BOTH COFFEE MAKERS, PER AMM 25-30-01 CL 58775 P1- ICT 651594 P2-ICT 651587. PN 416-0001-9 1 SN OFF 4535 SN ON 4641 2 SN OFF 01M9208010005 SN ON 0568.SDR DALA2020101603376Oven · contaminatedOVEN, INCLUDES OVEN TIMERS, DAMAGED/INOPERATIVE LOCATIONS:G1C/ACARS TEXT: FRC253402G1C CLEANING CHEMICAL SPRAYED INSIDE OVEN. HEAVY CHEMICAL SMELL WHEN USING OVEN, INTERIOR. OVEN WAS REPLACED AND ODI INPECTION WAS PERFORMED, PER LOG SHEET 1634186.SDR DALA2020101603375Oven · odorHEAVY CHEMICAL SMELL WHEN USING OVEN (IRF). F/A REPORTS CHEMICALS FOR CLEANING WERE APPARENTLY SPRAYED IN FWD GALLEY OVEN CAUSING PERFUMY CHEMICAL SMELL IN GALLEY AREA. WHILE USING OVEN, SMELL DISSIPATED WHEN OVEN NOT IN USE (IRO) FOUND SMELL/FUMES COMING FRSDR AALA202009219013Chiller · odorAIRCRAFT WAS GROUNDED. CHILLER IN FIRST CLASS GALLEY PUTS OUT ELECTRICAL ODOR WHEN TURNED ON. REPLACED FORWARD GALLEY CHILLER, PER AMM 25-34-51.SDR QXEA2020082700266Oven · odorFLIGHT ATTENDANT COMPLAINED OF HOT OVEN SMELL IN AFT OF AIRCRAFT DURING TAKEOFF & LANDING. REMOVED FROM SERVICE. ACCOMPLISH GVI OF OVEN AND COFFEE MAKER'S OPS CHECK OVEN & BOTH COFFEE MAKER'S, NO ODORS PRESENT. CONTACTED QX MAINTENANCE CONTROL, OK FOR SERVICE.SDR DALA2020082542862Oven · odorFWD OVEN, CAPT SIDE, LOC 103 MADE BURNING RUBBER/ELECTRICAL SMELL WHEN ACTIVATED. F/A TURNED OFF AND SECURED CB. REMOVED AND REPLACED OVEN 103 IAW A321 AMM 25-35SDR SWAA2020082009946Coffeemaker · odorDURING CRUISE @ FL410; FLIGHT ATTENDANTS REPORTED AN ODOR LIKE BURNING RUBBER IN AFT GALLEY AND AFT ROW OF AIRCRARFT; THEY PULLED AFT COFFEE MAKER CIRCUIT BREAKERS. SMELL DISSAPATED AFTER 15 MINUTES / FOUND #2 AFT COFFEE MAKER TO HAVE A BURNT SMELL TO & REPLACSDR AALA2020081439008Coffeemaker · odorAIRCRAFT NOT GROUNDED - ELECTRICAL ODOR FROM FORWARD GALLEY COFFEE MAKER. TURNED COFFEE MAKER OFF AND ODOR WENT AWAY. DEFERRED 8-284NEF-N: COFFEE MAKER/ESPRESSO MACHINE AUTHORIZED. INSPECTED BOTH GALLEY COFFEE MAKERS PER AMM 25-35-00, OPERATIONAL CHECK GOOD.SDR AWKA2020071501Relay · failedWHILE EN ROUTE TO SNA, FLIGHT CREW DETECTED WHAT SEEMED TO BE A CONSTANT BURNING MATCH SMELL IN THE COCKPIT. FLIGHT CREW CONTACTED MC CONTROL, AND THE DECISION WAS MADE TO DIVERT BACK TO LNK, WHERE THEY LANDED WITHOUT INCIDENT. DURING TROUBLESHOOTING, MX FOUSDR QXEA2020062200192Water Heater · odorBURNING PLASTIC SMELL DETECTED IN AFT GALLEY. REMOVED FROM SERVICE. INSPECTED AFT GALLEY AND FOUND LH MAPCO EXCESSIVELY WARM AND POWER GROUND STUD CONNECTION LOOSE. SECURED GROUND STUD AND OPERATED LH MAPCO FOR 15 MINUTES, DETERMINED SMELL TO EMANATE FROM LH MSDR CALA2020050200887Oven · malfunctionedOVEN/WARMERSMOKING OR SPARKING 708 DAMAGED SEAL CAUSES OVEN TO RELEASE SMOKE IN THE AFT GALLEY PENDING MEL APPLICATION FROM TOMC MEL 2500BR NOC DATE: 26-APR-20- TOMC APPROVED APPLIED MEL 2500BR TO OVEN 708 FOUND SEAL INTACT ON EXAMINATION. PULLED AND COLLAREDSDR CALA2020040300786Oven · odorACRID SMELL IN CABIN SMELLED WORSE IN BACK OF A/C T/S SMELL IN CABIN, RAN ENGINES ISOLATING PACKS AND BLEEDS WITH NO ODORS FOUND. ALSO RAN PACKS OFF OF APU WITH NO ODORS NOTED REF AMM 05-51-26. FOUND A OVEN IN THE FWD GALLEY SPOT 204 AND ONE IN AFT GALLEY SPSDR QXEA2020031800142Oven · odorFWD OVEN HAS BURNING ODOR EMANATING DURING USE. REMOVED FROM SERVICE. COULD NOT DUPLICATE ODOR. C/W OPS TEST OF FWD OVEN IAW E-175 AMM 25-37-02-710-802-A. OPS TEST GOOD. NO ABNORMAL ODORS NOTED. AIRCRAFT RETURNED TO SERVICE.SDR AALA202003129010Chiller · odorAIRCRAFT WAS GROUNDED: VERY BAD ODOR COMING FROM THE MID GALLEY CHILLER. REMOVED AND REPLACED CHILLER IAW AMM 25-33-05.SDR AALA2020030979022Oven · odorAIRCRAFT WAS GROUNDED: FORWARD GALLEY OVEN 1-6 HAS STRONG ODOR. ***SUPPLEMENTAL ACTION SECT 4 AND 5: REMOVED AND REPLACED FWD GALLEY 1-6 OVEN IAW AMM 25-35-19.(CLOSED)SDR AALA2020030979020Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN #2 HAS ELECTRICAL SMELL WHILE IN USE. TENTS TO OVER HEAT. ***SUPPLEMENTAL ACTION SECTION 4 AND 5: REMOVED AND REPLACED FWD GALLEY OVEN #2 IAW AMM 25-35-19.***(CLOSED)SDR AALA2020030969022Oven · smokeAIRCRAFT WAS GROUNDED: FORWARD GALLEY #2 OVEN SMOKING. **SUPPLEMENTAL REPORT: REPLACED OVEN PER AMM 25-33-05** (CLOSED)SDR AALA202003069011Warmer · odorAIRCRAFT WAS GROUNDED: FIRST CLASS BUN WARMER PRODUCES PLASTIC BURNING ODOR WHEN TURNED ON AND GOES AWAY WHEN TURNED OFF. **SUPPLMENTAL REPORT: REPLACED #2 BUN WARMER PER AMM 25-32-02 ** (CLOSED)SDR AALA2020031059017Coffeemaker · defectiveAIRCRAFT GROUNDED - 1ST CLASS ESPRESSO MAKER EMITS STRONG ELECTRICAL ODOR WHEN BREW IS SELECTED. REPLACED ESPRESSO MAKER, OPS CHECKED OK.SDR AALA2020030659020Oven · odorAIRCRAFT WAS GROUNDED: AFTER TAKE OFF THE CREW SMELLED A TOXIC ODOR IN COCKPIT AND STORAGE IN FORWARD GALLEY AND A VERY STRONG ODOR IN BACK. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO PHL WHERE IT LANDED WITHOUT FURTHER INCIDENT. THE FORWARD GALLEYSDR AALA202003029004Oven · odorAIRCRAFT WAS GROUNDED: DIVERTED TO SCQ. FLT. ATTENDANTS AND F/O REPORTED ACRID ODOR LIKE BURNING WIRES IN AFT GALLEY. PULLED ALL CB'S IN GALLEY.ODOR PERSISTED SMOKE/FUMES/ODOR IN CABIN ELECTRICAL. EMERGENCY WAS DECLARED. ACCOMPLISHED APPLICABLE STEPS OF JOB CASDR AALA202002269013Coffeemaker · odorAIRCRAFT NOT GROUNDED: ELECTRICAL BURNING ODER EMITTING FROM ONE OF THE FORWARD GALLEY COFFEE MAKERS ODER DISSIPATED AFTER COFFEE MAKERS TURNED OFFSDR AALA2020022549033Oven · odorAIRCRAFT WAS GROUNDED: DURING TAKEOFF AND CLIMBOUT F/A REPORTED STRONG ODOR THAT WAS LIKE BURNING PLASTIC. ODOR DISSAPETED AWAY IN ABOUT 10 MINUTES. COMPLIED WITH A320F SMOKE ODOR FUMES INITIAL T.S. JOBCARD 26L00021001. REPLACED FWD GALLEY OVEN DUE TO SMELL. OSDR UIEA2020022620304Oven · smokeAFT GALLEY A114 OVEN SMOKING (SMOKE TRIPPED AFT LAV SMOKE DETECTORS). LP 1068450: AFT GALLEY A118 OVEN HAS ELECTRICAL ODOR WHEN HEATING.(<P>SMOKE CAUSED BY DIRTY OVEN. TRANSFERRED TO MDDR 124962, NEF 25-20-01, GALLEY, ITEM 3, CAT C, DUE 03 MAR 20. C/B PULLED ASDR DALA2020022101316Coffeemaker · odorON DESCENT FA REPORTED SMOKE SMELL AROUND FWD GALLEY. WE SMELLED IT IN COCKPIT AT SAME TIME (BURNT POPCORN SMELL). NOTHING WAS IN OVEN. I TURNED OFF GALLEY PWR SMELL DISSIPATED FA REPORTED SMELL WAS AROUND #1 COFFEE MKR. RESTORE GALLEY PWR. TURNED BOTH COFFEE SDR DALA2020021901242Coffeemaker · failedDURING CLIMB, FLT ATTEND'S SMELLED ODOR FROM COFFEE MKR. COFFEE MAKER WAS EXTREMELY HOT, SMELLED LIKE ELECTRICAL BURN NEAR CKPT DOOR. I TURNED OFF GALLEY PWR. ALSO WALL AT COAT/HAT RACK WAS HOT TO THE TOUCH. AFTER GALLEY PWR WAS TURNED OFF FOR, ODOR WENT AWAY.SDR AALA2020022099019Oven · odorAIRCRAFT WAS GROUNDED: WARMING OVEN 3A IN FWD GALLEY HAS ELECTRICAL SMELL WHEN TURNED ON. REMOVED AND REPLACED WARMING OVEN 3A IN FORWARD GALLEY IAW AMM 25-32-02.SDR SF3R20200217001Controller · damagedCONDITIONS BEFORE INCIDENT IS CURRENTLY UNKNOWN. REQUEST TO OPERATOR FOR CONDITION HAS BEEN SUBMITTED. HOLE MELTED IN CONTROLLER COVER AND INSULATION INDICATING AN INTERNAL HEAT SOURCE HIGH ENOUGH TO MELT ALUMINUM AND INSULATION. : ROOT CAUSE ANALYSIS IS UNDESDR AALA202002179015Oven · odorAIRCRAFT WAS NOT GROUNDED: AN ELECTRICAL ODOR WAS SMELLED WHEN THE AFT LEFT GALLEY OVENS 9D & 9E WERE TURNED ON IN FLIGHT. THE SMELL DISSIPATED WHEN THE OVENS WERE TURNED OFF. REPLACED OVEN 9E (AALA202002169009) AND 9D (AALA202002179015) PER AMM 25-32-00.SDR AALA2020021769009Oven · odorAIRCRAFT WAS NOT GROUNDED: AN ELECTRICAL ODOR WAS SMELLED WHEN THE AFT LEFT GALLEY OVENS 9D & 9E WERE TURNED ON IN FLIGHT. THE SMELL DISSIPATED WHEN THE OVENS WERE TURNED OFF. REPLACED OVEN 9E (AALA202002169009) AND 9D (AALA202002179015) PER AMM 25-32-00.SDR AALA2020021759007Oven · odorAIRCRAFT WAS NOT GROUNDED: FIRST CLASS GALLEY OVEN #2 HAS AN ELECTRICAL ODOR. **SUPPLEMENTAL ACTION SECT 4 AND 5: REPLACED #2 F/C OVEN REF AMM 25-32-03.***(CLOSED)SDR CALA2020021600432Oven · underserviced1ST CLASS GALLEY OVEN 107 HEAVY SMOKE ON TAXI OUT. SMOKE LOCATED TO BURNT CARMEL IN THE BACK OF OVEN 107,C-B FOR OVEN 107 PULLED AND COLLARD OVEN NOT TO BE USED.AREA NOW OK NO SMOKE DETECTED.SDR SWAA2020021214307Coffeemaker · odorDECLARED EMERGENCY-------------------------------------------------------ADVISE BY FLIGHT ATTENDANT THE SMELL OF BURNING IN FORWARD GALLEY. NO SMOKE NOTED. DECLARED EMERGENCY & LANDED. / R&R FORWARD COFFEE MAKER PER AMM.SDR SIMA202002031001Floor Mat · odorFA REPORTS STRONG SMELL IN CABIN DURING FLIGHT.-C/A-REMOVED AND CLEANED FWD + AFT GALLEY FLOOR MAT SEALANT IAW MM 25-24-01. SEALANT CURE TIME C/W. PER SRM PART II 51-21-02.SDR SWIA2020013148035Coffeemaker · fumesCOFFEE MAKER EMITTED FUMES IN FLIGHT, TURNED IT OFF AND THE FUMES WERE MITIGATED BUT SMELL STILL EXISTS FLIGHT 3643 - FILED CLOSEDDEFERRED COFFEE MAKER. COMPLIED WITH MX ACTION. PLACARDS INSTALLED. AUTH. BY MCC.SDR QXEA2020012400042Oven · inoperativeFA REPORTS FWD GALLEY OVEN INOP AND SMELLS.SDR AALA2020012219018Coffeemaker · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS REPORTED BURNING ELECTRICAL SMELL IN AFT GALLEY. AFTER TURNING OFF POWER, COFFEE MAKER SMELL BECAME LESS INTENSE. BOTH COFFEE MAKERS REMAINED OFF FOR DURATION OF FLIGHT AS A PRECAUTION. MAINTENANCE TROUBLESHOT AND RSDR AALA202001189008Oven · odorAIRCRAFT WAS NOT GROUNDED: OVEN NR 1 SMELLS LIKE BURNING ELECTRICAL INSIDE. SUPPLEMENTAL REPORT: REPLACED OVEN PER AMM 25-32-02. (CLOSED)SDR AALA202001139007Oven · smokeAIRCRAFT NOT GROUNDED: AFT OVEN 9E HAD SMOKE COMING OUT SIDES OF OVEN. OVEN 9E REPLACED AND TESTED IAW DMC B7987 A 253200. ALL OPS CHECKED OK.SDR AALA202001069035Oven · smokeAIRCRAFT WAS GROUNDED: OVEN NUMBER 4BC SMOKING AFTER EXTENDED USE. REMOVED AND REPLACED NO.4BC OVEN AND OPS CHECK GOOD AND NO SMOKE IAW AMM 25-35-19.SDR N6WA201912302802Coffeemaker · odorELECTRICAL SMELL AND SMOKE COMING FROM BEHIND COFFEEMAKERS. T/S COFFEEMAKERS, DETERMINED THE NR 1 COFFEEMAKER HAS FAILED.SDR AALA201912269013Oven · odorAIRCRAFT WAS GROUNDED: ON TAXI OUT FAS REPORTED ELECTRICAL ODOR, SAID IT WAS STRONG. JUMPSEATER WENT BACK AND CONFIRMED ODOR, AND FOUND IT TO BE STRONGEST IN FIRST CLASS, LEFT SIDE, SECOND OR THIRD ROW. PAX REPORTED OILY SMELL. MAINTENANCE REPORTS UPON FURTHESDR AALA201912269014Oven · odorAIRCRAFT NOT GROUNDED: FWD GALLEY OVEN A/C LEFT SMOKEY SMELL OF BURNING PLASTIC AND ACRID ODOR. MAINTENANCE REMOVED AND REPLACED OVEN OPS CHECK OK.SDR SWAA2019121739760Coffeemaker · faultyDIVERSION----------------------------------------------------------DURING CRUISE WE WERE NOTIFIED THAT THE AFT GALLEY CIRCUIT BREAKER POPPED AND THE EMERGENCY EXIT LIGHTS ILLUMINATED. WHEN THE EMERGENCY EXITS LIGHTS BEGAN TO DRAIN & WITHOUT ANY INDICATION IN TSDR SWAA2019121739758Coffeemaker · faultyDIVERSION----------------------------------------------------------DURING CRUISE WE WERE NOTIFIED THAT THE AFT GALLEY CIRCUIT BREAKER POPPED AND THE EMERGENCY EXIT LIGHTS ILLUMINATED. WHEN THE EMERGENCY EXITS LIGHTS BEGAN TO DRAIN & WITHOUT ANY INDICATION IN TSDR AALA2019121869041Oven · odorAIRCRAFT WAS GROUNDED: CREW REPORTED CABIN ODOR DURING. MAINTENANCE PERFORMED CARD 08L00021001. FOUND BURNT ODOR EMANATING FROM FWD GALLEY OVENS REPLACED BOTH OVENS IAW AMM 25-32-03-401. NO ODOR FOUND FROM APU/PACKS.SDR AALA2019121769040Oven · smokeAIRCRAFT NOT GROUNDED: FWD GALLEY OVEN SMOKES SLIGHTLY DURING USE. ACCOMPANIED BY LIGHT SMELL OF BURNT PLASTIC AND VERY HOT SMELL. MAINTENANCE REMOVED AND REPLACED FWD GALLEY OVEN IAW AMM 25-35-19-000-0001A. OPS TEST GOOD. OK FOR SERVICE.SDR QXEA2019121700457Oven · odorAFTER USING FWD OVER FA SMELLED BURNING FROM OUTSIDE OVEN. TURNED OVEN OFF AND SMELL STOPPED. REMOVED FROM SERVICE. REMOVED OVEN IAW E175 AMM TASK 25-37-02-000-801-A, CLEANED DEBRIS FROM OVEN TOP, REINSTALLED OVEN IAW TASK 25-37-02-400-801-A, TURNED OVEN ON, ASDR AALA2019121319017Oven · odorAIRCRAFT NOT GROUNDED: FWD GALLEY OVEN WAS GIVING OFF FOUL BURNING SMELL, SMOKING OVEN, USE WAS DISCONTINUED. MAINTENANCE REMOVED & REPLACED FWD GALLEY OVEN #2 IAW AMM 25-32-02.
Back to JASC 2530