Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2019121302177Coffeemaker · leakingWATER LEAKING FROM MID GALLEY COFFEE MAKER. WOULD NOT STOP WITH SHUTOFF VALVE IN OFF REPLACED COFFEE REPLACED COFFEE MAKER.OPS GOOD. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1118399 SN OFF 0340 COFFEEMAKER, IN OFF 31-2534-9-0001 0340 ON 31-2534-9-0001 1504SDR AALA201912099010Oven · smokeAIRCRAFT NOT GROUNDED: FORWARD GALLEY OVEN NO.2 SMOKES WHEN TURNED ON. REMOVED AND REPLACED FWD GALLEY #2 OVEN IAW AMM 25-32-03. OPS CHECKED GOOD.SDR AALA201912099001Oven · fireAIRCRAFT NOT GROUNDED: FA CREW REPORTED THAT ONE OF THE SNACK BOXES IGNITED IN AN OVEN IN THE AFT GALLEY, WHILE BEING HEATED AT 275 DEGREES. SUPPLEMENTAL ACTION SECT 4: PERFORMED A OPERATIONAL CHECK AT 4A OVEN, NO FAULTS NOTED, IAW AMM 25-32-02. (CLOSED)SDR DXTA2019112213107Coffeemaker · odorCABIN ODOR BURNING SMELL - IN CRUISE WE SMELLED A ELECTRICAL BURNING ODOR IN THE CABIN AND COCKPIT. THE INTERIOR SWITCH WAS TURNED OFF AND THE ODOR WENT AWAY. THE ELECTRIC SYSTEM SMOKE OR FIRE QRH WAS REVIEWED ON THE DESENT TO THE DIVERTED AIRPORT.///SIGN-OFF/SDR DXTA2019112213108Fan · defectiveGALLEY FOOD CHILLER STARTED MAKING A GROWLING VIBRATION NOISE AND INCREASED IN INTENSITY OVER TIME WITH A SLIGHT ODER. CHILLER WAS TURNED OFF VIA CABIN CONTROL PANEL PUT THE GROWLING VIBRATION NOISE CONTINUED. THE COCKPIT AC/DC UTILITY WAS DISCONNECTED AND THESDR AALA2019111989036Oven · odorAIRCRAFT WAS GROUNDED: PILOT REPORTS VERY BAD DIRTY SOCK SMELL ON DECENT. MAINTENANCE ACCOMPLISHED JOB CARD - SMOKE ODOR FUMES INITIAL TROUBLESHOOTING. FOUND SOURCE OF ODOR TO BE FWD GALLEY OVENS. REPACED BOTH FWD GALLEY OVENS IAW AMM 25-35-19. NO ODOR EXISTS SDR AALA2019111989038Oven · odorAIRCRAFT WAS GROUNDED: PILOT REPORTS MUSTY/WET SOCK SMELL IN CABIN AND COCKPIT DURING CLIMB OUT. MAINTENANCE ACCOMPLISHED SOF TROUBLESHOOTING CARD 05-96-70. FOUND FIRST CLASS GALLEY OVEN #2 CREATING A STRONG ODOR WHEN TURNED ON. REMOVED AND REPLACED #2 FIRST CSDR DALA2019112276837Coffeemaker · smokeDURING CLIMBOUT ABOUT 1500' LEFT AFT CM STARTED TO SMOKE FROM CORNER OF HOT PLATE. COFFEEMAKER WAS SHUT DOWN AND CB 607 AND 608 PULLED & COLLARD, SMOKE DISAPPEARED WITHIN 5 MIN.REMOVED BOTH CM AND CLEANED CM TRAY. NO EVIDENCE OF FIRE MARKS. REPLACED BOTH COFFESDR CALA2019111601988Oven · odorRETURNED TO AIRPORT DUE TO STRONG ODOR ONCE A/C WAS AIRBORNE WIT H TAKEOFF THRUST PER FLT CREW DEBRIEF A/C UNDER MAX LANDING WEIGHT SMOOTH LANDING NORMAL SPEED. NO ABNORMAL INDICATIONS,"SMOKE SMELL"AND "LIGHT HAZE" DISSAPATED IN FLIGHT WITH NO REOCCURENCE PRIOSDR SWAA2019111438816Coffeemaker · inoperativeDIVERSION------------------------------------------------------------------SMOKE AND FUMES IN THE CABIN IT APPEARS TO BE THE FORWARD COFFEE MAKER. DIVERTED INTO ABQ. SMELLS DISSIPATED QUICKLY. / FOUND FORWARD COFFEE MAKER INOP. R&R COFFEE MAKER PER AMM.SDR AALA2019111209016Oven · odorAIRCRAFT WAS GROUNDED: PILOT REPORTS DURING EARLY PORTION OF DESCENT SMELLED AN ACRID, BURING OIL SMELL FOR ABOUT 3 MINUTES AFTER WHICH IT SLOWLY DISSIPATED. MAINTENANCE PEFORMED SMOKE ODOR FUMES INITIAL TROUBLESHOOTING IAW JOB CARD 05-96-70. FOUND OVEN TO BESDR DXTA2019110803043Coffeemaker · odorESPRESSO MACHINE - ON CLIMB OUT, STARTED TO SMELL A CHEMICAL ODOR LIKE BURNING PLASTIC. IT APPEARED TO BE THE ESPRESSO MAKER AND NO OTHER COMPONENTS. THEN IT STARTED TO PERMEATE SMOKE FROM THE ESPRESSO MAKER. WE ISOLATED VIA CIRCUIT BREAKER. WE THEN ENGAGESDR SWAA2019110738679Coffeemaker · fireSUPPLEMENTAL INFORMATION, DIVERSION/DECLARED EMERGENCY. FORWARD FA REPORTED FIRE AND SMOKE IN THE FORWARD GALLEY COFFEE MAKER. DIRECTED FA TO PULL CIRCUIT BREAKERS AND FIRE AND SMOKE STOPPED. NO FIRE EXTINGUISHER USED. THE FIRE REMAINED OUT WITH NO SMOKE. SDR DXTA2019110403018Chiller · odorSTRONG BURNING SMELL FROM CHILLER IN THE GALLEY.SDR CALA2019110501918Oven · fireOVEN 107 CAUGHT FIRE AND ARCHED. CREW DEBRIEFED AS PER AMM 05-51-56-940-801C1, SOURCE VERIFIED TO BE OVEN 107 IN FORWARD GALLEY. OVEN INTERNAL REAR ELEMENT AND F AN COVER REMOVED AND NOTED TO BE HEAVILY CONTAMINATED WITH BURNT FOOD REMAINS. SMOKE/ODUR IN THE CSDR CALA2019102501816Oven · smokeSMOKE EMITTING FROM 6 OVENS IN AFT GALLEY. 5 OVENS REPLACED. REF LGPG 3599862, 3599818, 3599796, 3599788, 3599791. R&R OVEN 709 REFF 25-32-03, ROTABLE PARTS CHANGE WAS INDICATED - TT # 1032294 SN OFF 0213 OVEN, ESSENCE S OFF 23-2531-9-0001 0213 ON 23-2531-9-SDR CALA2019102501815Oven · dirtyOVEN 413 CONTINOUS SMOKE...DIVERTED TO LAS, PLEASE SEE LOG PAGE 3602103. LP 3602103- OVEN 3 EXTEREMLY DIRTY. FOUND OVEN DIRTY, PULLED BREAKERS ON OVEN 3. OK TO DEFER. PULLED AND COLLARED CIRCUIT BREAKER FOR G3. REMOVED AND REPLACED #3 AFT GALLEY OVEN IRW AMM SDR CALA2019100501697Oven · failedOVEN 203 SMOKED AND FAILED. ELECTRIC SMELL R+R STEAMER OVEN #203 IN FWD GALLEY AS PER AMM 25-35-03,RAN STEAMER OVEN FOR 20 MINS ALL OPS CHK OK.SDR DALA2019100325662Oven · odorF/A REPORTS STRONG ODOR FROM OVEN 3 IN AFT GALLEY. R & R AFT NR 2 AND 3 OVEN PER B737 AMM 25-35 OPS CK OK FOR SERVICE.SDR AALA201909269006Fan · obstructedAIRCRAFT WAS GROUNDED: FLIGHT DIVERTED TO YYT ON ACCOUNT OF REPORTED ODOR IN THE COCKPIT. AN EMERGENCY WAS DECLARED. MAINTENANCE ACCOMPLISHED CARD 05-96-70 SMOKE, ODORS, FUMES T/S. FOUND 1ST CLASS GALLEY OVEN FAN BLOCKED WITH FOIL AND BURNT DEBRIS. NO OTHER ODSDR AALA201909239034Oven · smokeAIRCRAFT NOT GROUNDED: PILOT REPORTS FWD GALLEY OVEN SMOKES WHEN IN USE. MAINTENANCE REMOVED AND REPLACED FWD GALLEY OVEN IAW AMM 25-35-19, OPS CHECK NORMAL.SDR AALA201909239033Chiller · faultyAIRCRAFT WAS GROUNDED: PILOT REPORTS A CIRCUIT BREAKER IN THE AFT GALLEY (G4) POPPED STRONG ELECTRICAL SMELL WAS IDENTIFIED THEN DISSIPATED. MAINTENANCE FOUND AFT GALLEY CHILLERS AT FAULT. REPLACED LEFT AFT AND RIGHT AFT CHILLERS IAW AMM 25-33-02. OPS GOOD. (SSDR AALA201909249034Chiller · faultyAIRCRAFT WAS GROUNDED: PILOT REPORTS A CIRCUIT BREAKER IN THE AFT GALLEY (G4) POPPED STRONG ELECTRICAL SMELL WAS IDENTIFIED THEN DISSIPATED. MAINTENANCE FOUND AFT GALLEY CHILLERS AT FAULT. REPLACED LEFT AFT AND RIGHT AFT CHILLERS IAW AMM 25-33-02. OPS GOOD. (SSDR DALA2019091605381Coffeemaker · odorSHIP 3044 - RETURNED TO GATE DUE TO BURNING ODOR IN AFT GALLEY DURING TAXI-OUT. CORRECTIVE ACTION - COFFEE MAKER POSITION 403 HAD ODD ODOR. REPLACED ALL 3 AFT COFFEE MAKERS AS A PRECAUTIONARY MEASURE.SDR AALA201909159014Oven · fireAIRCRAFT WAS GROUNDED: PILOT REPORTS OVEN #9 HAD A BOX SANDWICH FIRE. COVERED IN HALON DISCHARGE. MAINTENANCE REMOVED AND REPLACED AFT GALLEY OVEN #9 IAW AMM 25-32-02. OPS CHECK OK.SDR ASAA2019091030697Oven · faultyFA'S REPORT "ELECTRICAL" SMELLING FUMES, PASSENGER ALSO SMELLS THEM, FROM ABOUT ROW 15 ALL THE WAY TO THE BACK, BUT NOT IN THE GALLEY. QHR3.1 FOLLOWED THROUGH STEP 11. AT THAT POINT ALL FUMES WERE GONE. WE LEFT ITEMS TURNED OFF, OFF FOR REMAINDER OF THE FLIGHTSDR DALA2019091305304Chiller · leakingPRIOR TO DISPATCH STRONG ACRID ODOR PRESENT IN FORWARD GALLEY AND COCKPIT AREA. INSPECTED FWD CARGO E/E COMPARTMENT FWD GALLEY AND COCKPIT NO DEFFECT FOUND. FOUND FWD GALLEY CHILLER FAULTY LEAKING AS THE SAME ODOR REPORTED. REPLACED CHILLER. SYSTEM OPERATION NSDR CALA2019090901512Oven · malfunctionedFWD GALLEY OVEN #102 WAS PRODUCING SMOKE FROM DEBRIS IN THE OVEN AND IS UNUSUALLY HOT. CREW SHUT DOWN EWRA CREW SHUT DOWN OVEN AND SMOKE STOPPED BUT HEAVY ODORS IN THE CAB IN REMOVED AND REPLACED OVEN 204 IAW AMM 25-34-00. ACCORDING TO AMM 05-51-58-910-801C1, SDR CALA2019090901511Oven · fireOVEN 103 INOP DEBRIS AND FOOD WASTE IN OVEN CAUGHT FIRE. DEBRIEFED CREW ON ARRIVAL F/A STATES OVEN 103 WAS ONLY SMOKING AFTER 3 MINUTES OF USE. REMOVED AND REPLACED OVEN AT STATION 103 REF AMM 25-34-00. OPS CHECKED ON HIGH FOR 10 MINUTES. NO DEFECTS NOTED. ROTSDR AALA201909069005Drain Line · out of positionAIRCRAFT WAS GROUNDED: PILOT REPORTS DURING BOARDING, AFTER STARTING APU LOTS OF BROWN FLUID BLEW OUT OF THE AIR VENTS PRIMARILY IN THE AFT CABIN. ABOUT A GALLON OF BROWN FLUID ON AFT GALLEY FLOOR, PLUS SOME KIND OF STRANGE ODOR. FIRE DEPT. VERIFIED NON TOXIC.SDR AALA201909039029Oven · smokeAIRCRAFT NOT GROUNDED: SMOKE COMING FROM AFT GALLEY OVEN 9D. REMOVED AND REPLACED OVENS #9D IAW AMM 25-32-00. OPS CHECK GOOD.SDR AALA201909039028Oven · smokeAIRCRAFT NOT GROUNDED: SMOKE COMING FROM AFT GALLEY OVEN 9C. REMOVED AND REPLACED OVENS #9C IAW AMM 25-32-00. OPS CHECK GOODSDR AALA201909029003Oven · odorAIRCRAFT WAS GROUNDED: PILOT REPORTS STRONG MUSTY/ACRID ODOR IN CLIMB OUT. DISSIPATED ON ITS OWN, BOTH COCKPIT AND CABIN. MAINTENANCE REPORTS ODOR/FUMES TROUBLESHOOTING ACCOMPLISHED IAW JOB CARD 05-96-70. SOURCE OF ODOR DETERMINED TO BE FROM FORWARD GALLEY OVESDR GTIA2019083084582Coffeemaker · odorFLIGHT ATTENDANTS REPORT BURNING RUBBER SMELL FROM AFT GALLEY ( COFFEE MAKERS )--SDR CALA2019083001452Oven · odorFA REPORTED UNIDENTIFIED ODOR AFTER TO IN AFT GALLEY PERFORMED SMOKE ODOR IN FLT. DECK/CABIN INSPECTION IAW MM 05-52-58-800-801C3. RAN APU, PACKS, HYD, LIGHTS, FLUSHED LAV, IFE EQUIP. AND CHECKED FOR TRIPPED C/BS. TURNED ON ALL COFFEEMAKER, WARMER, AND OVENSSDR DALA2019082975070Oven · odorFLIGHT 80, CREW REPORTED ELECTRICAL ODOR, SMOKE AND OVERHEAT LIGHT ILLUMINATED AT FORWARD GALLEY OVEN DURING OPERATION. C/B WERE PULLED AND FLIGHT CONTINUED TO DESTINATION. REPLACED THE OVEN. SYSTEM OPERATION IS NORMAL.SDR DXTA2019082702803Coffeemaker · odorCLIMBING OUT OF 12,000 FEET, WE TURNED OFF THE APU. IMMEDIATELY HAD A BURNING ODOR. SHUT OFF COFFEE POT AS WELL. INVESTIGATED THE CABIN, SLIGHT SMELL. RETURNED TO COCKPIT, ODOR COMPLETELY DISSIPATED . 19600 FEET. RAN AIRCRAFT WITH BOTH ENGINES BLEED AIR ANDSDR QXEA2019082100326Oven · smokeENROUTE, THERE WAS SMOKE FROM THE OVEN IN THE AFT GALLEY. SMOKE STOPPED ONCE THE OVEN WAS TURNED OFF. REMOVED FROM SERVICE FOR INSPECTION.SDR DALA2019082734991Oven · malfunctionedWHEN FA OPENED FC OVEN HE SAW AN ORANGE GLOW. OVEN WAS SHOT ASAP OVEN WAS TURNED OFF NO SMOKE FUMES OR HEAT REPORTED MEALS WERE REMOVED WITH NO SIGN OF DAMAGE. REPLACED OVEN AND OPS CHECKED IT OVEN OPS NML.SDR AALA201908219010Chiller · odorAIRCRAFT NOT GROUNDED: ELECTRICAL SMELL FROM FWD GALLEY - CHILLER. REMOVED AND REPLACED FWD GALLEY CHILLER IAW AMM 25-34-51-400-001-A. OPERATIONAL TEST IAW AMM 25-34-51 CHECKS GOOD.SDR AALA2019080879049Chiller · odorAIRCRAFT WAS GROUNDED: PILOT REPORTS DURING TAXI OUT, REAR GALLEY NOTICED STRONG ELECTRICAL SMELL. RETURNED TO GATE. MAINTENANCE REMOVED AND REPLACED R/H AFT CHILLER AS REQUIRED IAW AMM 25-33-02. OPS CHECK OK. NO DEFECTS NOTED AT THIS TIME.SDR AALA2019080759029Coffeemaker · sparksAIRCRAFT NOT GROUNDED: PILOT REPORTS FLIGHT ATTENDANT REPORTED THAT FWD COFFEE MAKER WAS SPARKING, C/B POPPED. REMOVED AND REPLACED FWD GALLEY #2 COFFEE MAKER. OPS CHECKED, LEAK CHECKED OK IAW AMM 25-39-02.SDR DALA2019080504564Coffeemaker · odorSTRONG ELECTRICAL SMELL COMING FROM FORWARD GALLEY. C/W NO GO ODI PREVENTION PROGRAM ATA 2172. FOUND FWD GALLEY COFFEE MAKER POPPING C/B. R/R COFFEE MAKER PER MD88 25-36, CKS GOOD. PERFORMED PNEUMATIC SYSTEM DUCT BURNOUT PER AMDS 7100-2619. R/R WATER SEPERATORSDR CA190919003Controller · burned(CAN) DURING THE CRUISE AT FL370 WHILE THE OVEN WAS PREHEATING, A BURNING SMELL WAS NOTED IN THE GALLEY AND SMALL TRACES OF SMOKE WERE OBSERVED EMANATING FROM THE FACE OF THE OVEN CONTROLLER. THE FLIGHT CREW CONSULTED THE APPLICABLE CHECKLIST IN THE QRH. ELECTSDR AALA201908029014Oven · malfunctionedAIRCRAFT WAS NOT GROUNDED: FIRST CLASS GALLEY OVEN #1 OFF BUT STILL CREATING HEAT AND SOME SMOKE. MAINTENANCE REPLACED GALLEY OVEN PER MM 25-33-91-4.SDR AALA2019080529011Oven · smokeAIRCRAFT WAS GROUNDED: PILOT REPORTS EXCESSIVE SMOKE OUT OF INTERIOR OF L/H OVEN WHEN USED. MAINTENANCE REPLACED FWD GALLEY L/H OVEN IAW AMM 25-39-19. OPS CHECK GOOD.SDR RAIA2019080290001Coffeemaker · arcedF/A SMELLS BURNING PLASTIC. NO SMOKE, NO FIRE, PAX REPORTED BURING WIRING SMELL. NO ODOR DETECTED ON ARRIVAL. INSPECTED GALLEY. FOUND NO BURNT OR DAMAGED COMPONENTS. #1 COFFEE BREWER WAS FOUND UNLATCHED AND UNSEATED. THE CONTACTS SMELLED OF ELECTRICAL ARCINGSDR AALA2019080131920Oven · odorAIRCRAFT NOT GROUNDED, PILOT REPORTS THERE WAS A SPARK, THEN AN ELECTRICAL BURNING SMELL IN GALLEY 3 OVEN. MAINTENANCE REMOVED AND REPLACED NR 3 OVEN IN MID GALLEY IAW AMM 25-35-19. ALL OPS CHECK OK.SDR AALA201907299019Oven · odorAIRCRAFT NOT GROUNDED: PILOT REPORTS OVEN GALLEY RIGHT SIDE HAD ELECTRIC SMELL ON START UP. TURNED OFF, SMELL WENT AWAY. C/B IS PULLED. MAINTENANCE REMOVED AND REPLACED FWD GALLEY RT OVEN AND OPS CHECK GOOD IAW AMM 25-35-19.SDR AALA201907309015Oven · smokeAIRCRAFT WAS GROUNDED: PILOT REPORTS SMOKE IN THE CABIN AT THE GATE. MAINTENANCE FOUND OVEN IN FWD GALLEY TO BE THE SOURCE. REMOVED AND REPLACED FWD OVEN IAW AMM 25-31-05. NO FURTHER SMOKE NOTED.
Back to JASC 2530