SDR AALA201907299026Oven · dirtyAIRCRAFT NOT GROUNDED: PILOT REPORTS FWD GALLEY # 2 OVEN STARTED TO PRODUCE SMOKE WHEN TURNED ON. DISCONTINUED USE FOR REMAINDER OF FLIGHT. MAINTENANCE CLEANED DEBRIS FROM OVEN, PERFORMED OPS CHECK IAW AMM 25-35-00. ALL CHECKS GOOD. NO SMOKE NOTED.SDR SWAA2019071935139Coffeemaker · faultyON INITIAL CLIMB OUT FLIGHT ATTENDANTS REPORTED A SLIGHT ELECTRIC BURNING SMELL THAT LASTED FOR JUST A FEW SECONDS AND THEN STOPPED. THE SMELL CAME FROM THE AFT GALLEY. R&R AFT 1 COFFEE MAKER PER AMM.SDR SWAA2019071935134Coffeemaker · faultyON INITIAL CLIMB OUT FLIGHT ATTENDANTS REPORTED A SLIGHT ELECTRIC BURNING SMELL THAT LASTED FOR JUST A FEW SECONDS AND THEN STOPPED. THE SMELL CAME FROM THE AFT GALLEY. R&R AFT 2 COFFEE MAKER PER AMM.SDR AALA201907169006Oven · smokeAIRCRAFT WAS GROUNDED: FLIGHT DIVERTED TO NYL ON ACCOUNT OF SMOKE FROM GALLEY OVEN. EMERGENCY DECLARED. LANDED WITHOUT INCIDENT. MAINTENANCE COMPLIED WITH JOB CARD 26L00021001, FOUND #1 FORWARD GALLEY OVEN AS SOURCE OF SMELL. ***SUPPLEMENTAL INFORMATION: MAINTSDR DALA2019071704308Oven · malfunctioned(AIRCRAFT 666, L/P 4996822) OVEN F103 LOUD FAN NOISE WHEN TURNED ON SOME SMOKE FROM OVEN. REMOVED AND REPLACED F103 OVEN PER AMM 25-31.SDR AALA201907159021Coffeemaker · malfunctionedAIRCRAFT WAS GROUNDED: FA REPORTED FUME SMELL AFTER T/O, SMELL DISSIPATED 10 MINUTES AFTER TAKEOFF. MAINTENANCE ACCOMPLISHED CARD 26L00021001. APU COMPARTMENT CLEAN, BOTH ENGINES CLEAN. ISOLATED BOTH PACKS, NO SMELL THROUGHOUT CABIN. FOUND REAR GALLEY COFFEEMASDR AALA201907149004Coffeemaker · odorAIRCRAFT WAS GROUNDED: AT CRUISE, FLIGHT ATTENDANTS CALLED FROM AFT GALLEY STATING AN ELECTRICAL BURNING SMELL FROM THE GALLEY. ACCOMPLISHED QRH PROCEDURE AND AFTER 15 MINUTES SMELL DISSIPATED. MAINTENANCE REPLACED #5 COFFEE MAKER PER AMM 25-32-00 AND ACCOMPLISDR AALA201907119005Latch · damagedAIRCRAFT WAS NOT GROUNDED: DOOR S1-240 HOLD OPEN LATCH DAMAGED AND INOPERABLE. MAINTENANCE REPLACED HOLD OPEN LATCH ON DOOR S1-240 PER AMM 25-31-00.SDR SIMA20190703001Receptacle · defectiveSUPLEMENTAL WHILE TAXING TO GATE IN DFW CREW NOTICED WARM ELECTRICAL BURNT ELECTRICAL SMELL IN COCKPIT AND AT FA STATION. C/A-UPON ARRIVAL NOTICED NO ABNORMAL SMELL THROUGHOUT ENTIRE CABIN, C/W FIM 25-31-00 810-810A & FIM 21-20-00 810-810A STEPS 1-6,8,14-18. FSDR DXTA2019062802542Coffeemaker · malfunctioned10 MINUTES AFTER DEPARTURE AND LEVEL AT 13,000' WE NOTICED AN ELECTRICAL BURNING SMELL. NO VISIBLE SMOKE, BUT ENOUGH ODOR TO CLEARLY IDENTIFY AN ISSUE. THE ODOR BECAME PRESENT IMMEDIATELY AND SEEMED TO BE MORE PRONOUNCED NEAR THE COCKPIT THAN THE REAR OF THESDR ASOA20190624033Entertain Sys · odorFLIGHT 4324, THE CREW REPORTED A BURNT WIRE SMELL FROM THE CD AREA IN THE GALLEY. THE AIRCRAFT LANDED IN MFE WITHOUT INCIDENT WHERE MAINTENANCE DEACTIVATED THE CD PLAYER. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. MAINTENANCE REMOVED AND REPLACED THE CSDR ANCF2019061901Coffeemaker · odorJUN 19. DURING TAXI MID GALLEY OVEN START EMITES SMOKE CUT CIRCUIT SMELL ON AREA. CORRECTIVE ACTIONS: JUN 19. CHECK MID GALLEY FOR ELECTRICAL/FIRE DAMAGE FIM 21-20-F5-72A-431A FOUND COFFEE MAKER N 13 IN SHORTCUT DEFER IAW NEF B-1 FW DMI 22104-3 B787-CNMCC-N794SDR AALA2019062099001Coffeemaker · smokeAIRCRAFT WAS GROUNDED: PILOT DECLARED EMERGENCY ON ACCOUNT OF ELECTRIC FIRE /SMOKE MID GALLEY BEHIND EXPRESSO MAKER NR 1 & 2. MAINTENANCE FOUND NR 2 EXPRESSO MAKER FAULTY, AS PRECAUTIONNARY REMOVED BOTH EXPRESSO MAKERS 1 & 2 IN MID GALLEY POSITION 4-11 , 4-12 SDR ASOA201906167084Coffeemaker · odorDISCREPANCY: FROM DMIL; BURNING SMELL FROM COFFEE MAKERS, WENT AWAY WHEN TURNED OFF. CORRECTIVE ACTION: C/W CHRONIC WORKSHEET W/O 573500. INSPECTED BOTH COFFEE MAKERS CANNON PLUGS AND TERMINALS FOR SMOKE/BURN DAMAGE IAW VCMM 25-30-39. OPERATIONAL CHECK GOOSDR ASOA201906167083Coffeemaker · odorDISCREPANCY: FROM DMIL; BURNING SMELL FROM COFFEE MAKERS, WENT AWAY WHEN TURNED OFF. CORRECTIVE ACTION: C/W CHRONIC WORKSHEET W/O 573500. INSPECTED BOTH COFFEE MAKERS CONNECTOR AND TERMINALS FOR SMOKE/BURN DAMAGE IAW VCMM 25-30-39. OPERATIONAL CHECK GOOD, SDR ASOA2019061935077Coffeemaker · odorCREW REPORTED BURNING SMELL FROM COFFEE MAKERS WENT AWAY WHEN TURNED OFF. MOVED TO DMIL PER GL-01. MX COMPLIED WITH CRONIC WORKSHEET W/O 573500, REMOVE AND INSPECT BOTH BREWERS, ELECTRICAL TERMINALS AND ALL WIRING ON AFT GALLEY WALLS AND RAILS, AND BOTH CANONSDR IPXA2019062653727Liner · crackedLOWER FWD CARGO DOOR LINER PNL 811-AZ IS CRACKED AT MULTIPLE AREAS AS MARKED.REPLACED LINER WITH NEW.SDR AALA201906039038Oven · odorAIRCRAFT WAS GROUNDED: PILOT DECLARED EMERGENCY ON ACCOUNT ELECTRICAL SMELL IN COCKPIT AND CABIN. MAINTENANCE FOUND FWD GALLEY OVEN SOURCE IAW J/C 26L00021001. REMOVED AND REPLACED FWD GALLEY OVEN IAW AMM 25-35-19.SDR AALA201905319003Oven · dirtyAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTED ODOR AND SMOKE FROM FORWARD LEFT OVEN. MAINTENANCE CLEANED DEBRIS FROM OVEN AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA20190529005Oven · overheatedAIRCRAFT WAS GROUNDED: PILOT REPORTS BOTH WARMING OVENS IN FIRST CLASS GALLEY GET TOO HOT AND OVERHEATING WITH AN ELECTRICAL WIRE SMELL, FOUND BURNT STICKY SUBSTANCE IN NR 2 BUN WARMER. MAINTENANCE REMOVED AND REPLACED NR 2 BUN WARMER IAW AMM 25-32-02. OPS NOWSDR RAIA201905310002Angle · corrodedCARGO DOOR Z ANGLE IS CORRODED. R&R CARGO DOOR Z ANGLE, REQUIRES SEALANT, PAINT & FILLER IN BOTTOM CORNERS. PAINTED, SEALED, APPLIED FILLER IN BOTTOM CORNERS & INSTALLED CARGO BAY DOOR PROTECTIVE PLATE.SDR DALA2019052803252Oven · smokeOVEN #5 SMOKING WHEN HEATING. CLEANED COMPARTMENT AIR EXTRACTION FILTER. AND REPLACED OVEN. SYSTEM OPERATION IS NORMAL.SDR ASOA201905264023Rail · faultyICT - FLIGHT 4378, THE FLIGHT ATTENDANT REPORTED A METAL BURNING SMELL IN GALLEY THAT STARTED GOING AWAY WHEN FLIGHT ATTENDANT TURNED OFF THE COFFEE POTS. THE COFFEE POTS WERE PLACED ON MEL AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. ON 05/28/19 IAH SDR ASOA201905264022Rail · faultyICT - FLIGHT 4378, THE FLIGHT ATTENDANT REPORTED A METAL BURNING SMELL IN GALLEY THAT STARTED GOING AWAY WHEN FLIGHT ATTENDANT TURNED OFF THE COFFEE POTS. THE COFFEE POTS WERE PLACED ON MEL AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. ON 05/28/19 IAHSDR CA190524026Coffeemaker · failed(CAN) WESTJET ENCORE`S COMPONENT SHOP FOUND THAT PMA HOT JUG P/N B81-01-2 FROM COMMERCIAL AIRCRAFT EQUIPMENT USED IMPROPER CRIMPING METHODS DURING MANUFACTURING. THE HOT JUG WAS INITIALLY REMOVED DUE TO FAILURE TO HEAT. FURTHER INVESTIGATION FOUND THE TERMINALSDR SWAA2019052833027Coffeemaker · faultyFORWARD COFFEE MAKER PUT OFF ELECTRICAL ODOR. R&R COFFEE MAKER PER AMM.SDR AALA201905229014Chiller · odorAIRCRAFT WAS GROUNDED: PILOT REPORTS ODOR IN AFT GALLEY. SMELLED ELECTRICAL WENT AWAY ONCE CHILLERS WERE TURNED OFF. MAINTENANCE REMOVED AND REPLACED AFT GALLEY CHILLER IAW AMM 25-34-51. OPS CHECK NORMAL.SDR J7SA201906125002Oven · odorSTRONG BURNING SMELL COMING FROM MICROWAVE WHEN POWERED ON. SET GALLEY CONTACTOR TO OFF ON DU1. REMOVED AND REPLACED WAVEJET MICROWAVE OPS CHECKED, NO BURNING SMELL AT THIS TIME. IAW LEGACY 450/500 AMM 25-32-02SDR CA190514006Oven · smoke(CAN) AT APPROX 1915Z CABIN FLIGHT ATTENDANT SPOTTED SOME SMOKE COMING OUT OF THE BACK OF THE MICROWAVE. THEY IMMEDIATELY ISOLATED THE MICROWAVE ELECTRICALLY AND THE PROBLEM STOPPED. NO EMERGENCY WAS DECLARED. MICROWAVE HAS BEEN INSPECTED AND TESTED WITH NOSDR DALA2019051302996Chiller · malfunctioned(LOG 5768692) FLT CREW REPORTED AN ELECTRICAL SMELL COMING FROM FWD GALLEY NEAR CHILLER. REPLACED FWD GALLEY CHILLER PER AMM 25-31. OPS NORMAL.SDR AALA201905099010Oven · odorAIRCRAFT WAS GROUNDED: PILOT REPORTS LEFT OVEN (FACING AFT) HAS A STRONG BURNING SMELL WHEN IT IS TURNED ON, HOWEVER THERE WAS NO SMOKE ASSOCIATED WITH THE ODOR . MAINTENANCE REPLACED LT OVEN IAW AMM 25-32-03. OPS CHECK GOOD.SDR DALA2019050702943Oven · malfunctioned(AIRCRAFT 695, L/P 1063060) OVEN -INCLUDES OVEN TIMERS DAMAGED / INOPERATIVE / LOCATIONS:OVE / ACARS TEXT: FRC253402 OVEN SHUT OFF MID COOKING-ELECTRICAL SMELL EMITTED / INTERIOR. R/R FWD GALLEY OVEN PER AMM 25-31 OPS NML. NO FAULTS NOTED.SDR CA190502012Oven · failed(CAN) OCM ADVISED MOC THAT FLT WAS DIVERTING DUE TO SMOKE/BURNING ODOR IN AFT GALLEY/CABIN. OVEN OPERATED FOR SEVERAL MINUTES AND ELECTRICAL BURNING ODOR WAS OBSERVED. MAINT OPENED OVEN COMPARTMENT DOOR AND THE SMELL WASN`T VERY STRONG. MAINT REMOVED OVEN CONTSDR AALA201905019030Oven · overheatedAIRCRAFT NOT GROUNDED: PILOT REPORTS FLIGHT DIVERTED TO TUL ON ACCOUNT OF OVENS OVERHEATING. EMERGENCY DECLARED. FLIGHT WAS NOT OVERWEIGHT, LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE NR 2 OVEN AND OPS CHECKED IT IAW AMM 25-32-03.SDR DALA2019042632662Seal · burnedIN FLIGHT SLIGHT SMELL COMING FROM FRONT GALLEY OVEN. OVENS SHUTOFF, WARMING BINS SHUTOFF SMELL DISSIPATED. FOUND # AND #3 DOOR SEAL BURNT DAMAGE. REPLACED #1 FORWARD GALLEY OVEN.SDR ASOA2019042413027Coffeemaker · smokeTHE CREW REPORTED SUSPECTED ELECTRICAL SMOKE FROM THE COFFEE MAKER. MAINTENANCE REPLACED THE NR 2 COFFEE BREWER DUE TO ELECTRICAL SMELL. OPERATIONAL AND LEAK CHECKS WERE GOOD.SDR CA190422004Coffeemaker · damaged(CAN) SMOKE OCCURRED FROM THE AFT GALLEY IN THE LOCATION OF THE OVEN/COFFEE MAKER AREA..PAN PAN DECLARED. RESOLUTION AREA INSPECTED FOUND COFFEE MAKER DAMAGED IN POSITION 512. COFFEE MAKER REPLACED. (TC# 20190422004)SDR AALA2019042299004Microwave Oven · odorAIRCRAFT NOT GROUNDED: FLIGHT ATTENDANTS REPORTED ELECTRICAL ODOR FROM FORWARD GALLEY MICROWAVE WHEN IN USE. MAINTENANCE REPLACED MICROWAVE PER ESO 21258 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR DALA2019041802520Oven · smokeAPPROXIMATELY 3 HOURS FROM LANDING, FLIGHT ATTENDANT ADVISED THERE WAS SMOKE IN FORWARD GALLEY. TRACE OF SMOKE ISOLATED TO FORWARD GALLEY OVENS. COMPLIED WITH QRH AND PULLED FORWARD GALLEY OVEN CIRCUIT BREAKERS. SMOKE DISSIPATED. REPLACED OVEN. SYSTEM OPERATIOSDR AALA201904179001Drain Valve · odorAIRCRAFT WAS GROUNDED: PILOT REPORTS EXTREMELY FOUL ODOR THROUGHOUT A/C AS SOON AS RECIRCULATION FANS TURNED ON, APU OFF. MAINTENANCE ACCOMPLISHED WORK CARDS 05-96-70 AND 38-94-14. FOUND THE FIRST CLASS GALLEY DRAIN SILL VALVE FAILED CLOSED AND HOSE SPLIT. REMSDR RAIA2019042320024Holder · crackedCARGO BAY DOOR ROD HOLDER IS CRACKED....R&R CARGO BAY DOOR ROD HOLDERSDR DALA2019041002378Oven · fireSHIP 7004 -FIRE- FWD GALLEY OVEN FIRE DUE TO MELTED AND SPILLED CHOCOLATE DURING OPERATION. EXTINGUISHER USED (REFERENCE LOGPAGE 5656327) / FIRE EXTINGUISHED /C/B PULLED / FLIGHT CONTINUED. CORRECTIVE ACTION: REMOVED AND REPLACED OVEN LOCATION 401 PER B777 AMMSDR DALA2019041002379Coffeemaker · failedCOFFEE MAKER FORWARD GALLEY HAD SPARK THEN SMOKE WHEN ACTIVATED. TURNED OFF UTILITY BUSES. LOCATION F105 #1. REPLACED COFFEE MAKER PER B757 AMM 25-31. OK FOR SVC.SDR YENA201904128189Coffeemaker · odorFT # 149, JFK-PSP. COFFEE POT 105 HAS BURNING WIRE/MATCH SMELL INFLT TURNED OFF & SMELL WENT AWAY ( COFFEE MAKERS ); REPLACED COFFEE MAKER #105 PER AMM 25-35-00. OPS CK GOOD. MDDR CLEARED. MX-4 UPDATED.SDR QXEA2019040400154Coffeemaker · overheatedFORWARD INBOARD COFFEE MAKER OVERHEAT AND OVERFLOWED.REMOVED FROM SERVICE. CLEANED COFFEE GRAINS FROM COFFEE MAKER AREA. BREW COFFEE AND NO OVER HEAT OR OVERFLOW NOTED. NO OTHER DEFECTS NOTED AT THIS TIME. RETURNED TO SERVICE. NO PARTS REPLACED.SDR SWAA2019040131206Coffeemaker · faultyDIVERSION, AFT GALLEY FLIGHT ATTENDANTS SMELLED SMOKE. FOUND CHARRED CARDBOARD DEBRIS UNDERNEATH OUTBOARD COFFEE MAKER IN AREA SMOKE WAS REPORTED. R&R AFT COFFEE MAKER PER AMM.SDR DALA2019032601913Oven · malfunctionedSHIP 9008 - ATB - RETURNED TO ATL DUE TO SMOKE DETECTOR IN FORWARD LAVATORY ACTIVATED ALONG WITH STRONG SMELL ON TAKE-OFF AT 300FT. CORRECTIVE ACTION: WHILE WORKING NO GO ODI WORK CARD 2120-2367 FOUND OVEN PRODUCING ODOR DESCRIBED ON SMOKE AND FUMES QUESTIONNASDR QXEA2019032500138Coffeemaker · defectiveFWD LEFT COFFEE MAKER SPILLING COFFEE AND BURNING THE COFFEE BAGS. REMOVED FROM SERVICE. REMOVED COFFEE POT AND CLEANED SURROUNDING AREA AND SENSORS AS REQUIRED. PERFORMED BREW TEST. COFFEE MAKER OPERATED NORMALLY. NO OTHER DEFECTS NOTED.RETURNED TO SERVICE. NSDR CA190325003Oven · odor(CAN) DURING CRUISE CREW REPORTED ELECTRICAL SMELL FROM OVEN 1 IN FRONT GALLEY. OVEN WAS TURNED OFF AND NOT REUSED.SDR ASOA201903185043Coffeemaker · odorCREW REPORTED COFFEE POT NR 2 NOT WORKING BURNT SMELL. SUPPLEMENTAL REPORT 03/22/2019 XJT ORD MX PRIMED COFFEE MAKER AND PERFORMED OPS CHECK ON THE NR 2 COFFEE MAKER GOOD.*****************THIS SDR IS NOW CLOSED****************
Back to JASC 2530