Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2016072505510Coffeemaker · failedDURING CLIMB OUT, AN ELECTRICAL ODOR WAS DETECTED IN THE COCKPIT AND CABIN WITH FINE HAZE. RAN QRH, SMOKE AND FUME CHECK LIST. F/A NOTED THE FWD AND AFT GALLEY COFFEE MAKER HAD SHUT ITSELF OFF. THE F/A WAS DIRECTED TO PULL ALL FWD AND AFT GALLEY CIRCUIT BREASDR CALA2016071800429Oven · smokeCIRCUIT BREAKER PULLED ON AFT GALLEY OVEN 413 DUE TO SMOKE FROM OVEN. INSPECTION CARRIED OUT IAW AMM 05-51-58-9. CONFIRMED SMOKE COMING FROM OVEN 413. I 10-801C1 CAUSE OF SMOKE OVEN 413.SDR CALA2016071895567Chiller · odorSTRONG ELECTRICAL ODOR THROUGH ENTIRE AIRCRAFT, LASTED 30 MINUTES OF FLIGHT. REMOVED AND REPLACED CHILLER C21 IAW AMM 25-33-01. PERFORMED INSPECTION OF CABIN NO ODOR NOTED.SDR AALA20160713003Oven · faultyDURING CLIMB, CREW REPORTED A BURNING ODOR IN COCKPIT AND ABOVE ELECTRONIC EQUIPMENT ACCESS DOOR. EMERGENCY DECLARED. LANDING UNEVENTFUL. AIRCRAFT WAS GROUNDED. MAINTENANCE REMOVED AND REPLACED FORWARD GALLEY OVEN IAW AMM 25-32-02, ENTERTAINMENT SYSTEM COSDR DXTA2016071106265Outlet · smokeTOASTER WAS PLUGGED INTO GALLEY OUTLET TO TOAST A BAGEL. WHEN POWER WAS APPLIED TO TOASTER, SMOKE CAME OUT OF GALLEY OUTLET. PERFORMED A VISUAL INSPECTION OF OUTLET, WIRING AND TOASTER WITH NO DEFECTS FOUND. TESTED OUTLET WITH OUTLET TESTER AND FOUND GOOD, SDR AALA20160718010Coffeemaker · odorDURING FLIGHT, CABIN CREW REPORTED AN ELECTRICAL ODOR COMING FROM AFT GALLEY NR 4 COFFEEMAKER WHEN TURNED ON. MAINTENANCED CONFIRMED THE COFFEEMAKER AS SOURCE OF THE ODOR. REMOVED AND REPLACED THE COFFEEMAKER IAW AMM 25-32-00. OPS CHECKED NORMAL.SDR AALA201607109002Oven · odorFORWARD GALLEY OVEN HAS STRONG BURNING ODOR WHEN ON. MAINTENANCE REPLACED THE FORWARD GALLEY OVEN AND ACCOMPLISHED A SATISFACTORY OPS CHECK IAW AMM 25-35-19-710-052-A.SDR AALA201607099006Oven · overtempOVEN OVER HEATED NEAR POSITION C-24. OVER TEMP LIGHT CAME ON, AND AN ODOR OF BURNING WIRING. CIRCUIT BREAKER PULLED. REPLACED C-24 OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 25-35-19.SDR DALA2016070705207Coffeemaker · malfunctionedCOFFEEMAKER, F303, NR 1 TURNED ON. IN FLT, SMELLED ELECTRICAL BURNING. SECURED, ODOR DISSIPATED IMMEDIATELY. DEFERRED IAW NEF 253602. COFFEEMAKER REPLACED ON 08JUL16.SDR AALA20160706006Oven · contaminatedFLIGHT ATTENDANT REPORTED SMOKE ODOR IN THE FORWARD ENTRY AREA. NOTICED SLIGHT WHITE SMOKE NEAR L1 DOOR. PERFORMED FIM TASK 21-00-00. FOUND BURNED PLASTIC ON OVEN VENT FAN. REMOVED PLASTIC. COULDN"T FIND ANY OTHER SOURCE. CHECKED ENGINE AND APU FOR EVIDENCESDR SWAA2016070553391Coffeemaker · faultyFLIGHT ATTENDANT REPORTS "BURNING PLASTIC" SMELL FROM AFT GALLEY & STRONG "BURNING PLASTIC" SMELL FROM WHEEL CHAIR COMPARTMENT. R&R NR 1 COFFEEMAKER PER MM.SDR AALA201607039001Oven · smokeAIRCRAFT WAS NOT GROUNDED: AFT GALLEY OVEN (413) BLACK SMOKE COMES OUT WHEN USED. REPLACED AFT GALLEY OVEN(413) PER AMM 25-31-05 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201607019005Chiller · failedODOR IN AFT GALLEY.MAINTENANCE FOUND AFT CHILLER FAIL LIGHT ILLUMINATED, AND IDENTIFIED ODOR TO FAILED CHILLER MOTOR. REPLACED AFT GALLEY AIR CHILLER PER AMM 25-34-51-000-002-A AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR UIEA2016062800527Oven · smokeOVEN 60-3 BEGAN SMOKING AND HAD STRONG ELECTRICAL BURNING ODOR. ITEM TRANSFERRED TO MDDR 67915 IAW DDG 25-20-01, GALLEY ITEM 6.SDR AALA201606289005Oven · odorAIRCRAFT WAS NOT GROUNDED: OVEN 2 (4-3) TEMP LIGHT CAME ON AND AN ELECTRICAL SMELL. WAS NOTED. OVEN WAS DEACTIVATED BY PULLING THE CIRCUIT BREAKER. REMOVED AND REPLACED OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-33-00.SDR DALA2016062905130Oven · odorFLIGHT ATTENDANTS REPORT BURNING, ELECTRICAL ODOR DURING CLIMB. GALLEY AND SIDEWALL LIGHTS POWER SECURED PER QRH. ODOR DISSIPATED. TROUBLESHOT. ODOR NOTED WHEN RUNNING OVEN. REMOVED AND REPLACED OVEN PER MM.SDR AALA201606239007Coffeemaker · odorAIRCRAFT WAS GROUNDED. WHILE ENROUTE F/A`S REPORTED A NOXIOUS ALCOHOL ODOR IN AFT GALLEY. ODOR WAS TOO STRONG FOR THEM TO REMAIN IN THE AREA AT TIMES. MAINTENANCE ACCOMPLISHED TASK CARD 26L00021001 AND REPLACED AFT GALLEY COFFEEMAKER NR 2 IAW AMM 25-35-15-0SDR DALA2016061704739Oven · malfunctionedUPPER DECK OVEN OVERHEATED MEAL WITH ODOR AND SMALL FLAME THAT EXTINGUISHED IMMEDIATELY. REPLACED OVEN AND OVEN CONTROLLER BUT DEFERRED IAW MEL FOR FURTHER TROUBLESHOOTING AND INSPECTION.SDR AALA201606169003Coffeemaker · defectiveAIRCRAFT WAS NOT GROUNDED: CABIN CREW REPORTED FAINT HOT PLASTIC ODOR IN THE FORWARD GALLEY. THE ODOR WENT AWAY WHEN GALLEY ELECTRICAL WAS TURNED OFF. MAINTENANCE DETERMINED SOURCE TO BE THE FORWARD GALLEY COFFEEMAKERS AND REPLACED THEM IAW AMM 25-37-03. A SDR AALA201606149002Oven · odorAIRCRAFT WAS NOT GROUNDED, ELECTRICAL ODOR WHEN OPERATING OVEN. REPLACED FORWARD OVEN IAW AMM 25-35-19.SDR AALA201606139006Coffeemaker · smokeAIRCRAFT WAS NOT GROUNDED: F/A REPORTED LIGHT SMOKE FROM AFT GALLEY COFFEEMAKER. SMOKE CLEARED WHEN POWER WAS REMOVED FROM THE COFFEEMAKER WHICH REMAINED UNPOWERED FOR THE DURATION OF THE FLIGHT. MAINTENANCE REPLACED BOTH AFT GALLEY COFFEEMAKERS IAW AMM 25-35SDR AALA201606099012Coffeemaker · contaminatedAIRCRAFT WAS NOT GROUNDED: REAR GALLEY ODOR LIKE SOMETHING HOT OR BURNING. PULLED C/B'S IN GALLEY. FOUND PLASTIC BURNING ON BURNER PAD, REPLACED COFFEEMAKER AND ACCOMPLISHED A SATISFACTORY OPS CHECK WITH NO ODORS NOTED IAW AMM 25-35-15.SDR DALA2016060804423Oven · smokeCREW REPORTED THE FORWARD GALLEY OVEN SMOKING FROM TOP VENT. CABIN CREW PULLED OVEN CIRCUIT BREAKER AND SMOKE SUBSIDED. MAINTENANCE FOUND PLASTIC INSIDE OVEN HAD BEEN BURNING. THE OVEN WAS REPLACED IAW AMM. COMPLIED WITH NO GO ODI PREVENTION FOR SMOKE IN CABSDR HNAA2016060700166Coffeemaker · odorSTRONG ELECTRICAL ODOR IN CABIN COMING FROM ROW 2A AND 3A OVERHEAD. INSPECTED AND FOUND LIQUID CONTAINER TO BE CAUSE OF ODOR. UNPLUGGED LIQUID CONTAINER. R & R HOT JUG RECEPTACLE IAW AMM 25-30-02-04. OPS CHECKED GOOD.SDR HALA2016060600227Oven · smokeOVEN NR 4 AFT GALLEY. F/A REPORTED SEEING SMOKE EMIT FROM OVEN IN LESS THEN 2 MINUTES AFTER TURNING IT ON. OPERATED OVEN NR 4 ON HIGH SETTING FOR 10 MINUTES - 3 TIMES. NO DEFECTS NOTED. OK FOR SERVICE.SDR CALA2016060600352Oven · odorELECTRICAL & HEAT ODOR EMANATING FROM GALLEY B AREA. FIM DMC B787-A-05-51-99-99A-282A-A FOLLOWED. SMOKE & ODOR QUESTIONNAIRE COMPLETED & FWD TO TOMC. OVEN 408 FOUND CRITICAL ERROR FUSE BROKEN. OVEN INSPECTION CUT OUT OVEN OVER HEAT. OVEN REPLACED IAW DMC SDR DXTA2016060306246Microwave Oven · odorDURING CRUISE FLIGHT, THE MICROWAVE CB TRIPPED & LOCKED. A POP & A FAINT ELEC SMELL WERE OBSERVED BY THE FLIGHT ATTENDANT. DEFERRED IAW MEL. MX PROCEDURE ACCOMPLISHED. REPLACED MICROWAVE IAW MM 25-70-01 & REPLACED AC-PDE-5 IAW MM 24-52-52. ALL SYSTEMS OPESDR CALA2016052600327Oven · fireOVEN R42 A4, PAPER CONTENTS SHEET LEFT ATTACHED TO INSERT & CAUGHT FIRE WHEN OVEN REACHED TEMPERATURE. EXTINGUISHED WITH HALON. NO OTHER DAMAGE NOTED. CONFIRMED ONLY ATTRIBUTED TO A4 PAPER SHEET LEFT ON INSERT. ACCOMPLISHED CHECKS IAW AMM 05-51-56 & FORM 4SDR DALA2016052704262Oven · smokeLIGHT SMOKE FROM OVEN 2, FWD GALLEY. STOPPED WHEN POWER REMOVED. EVIDENCE OF ELECTRICAL FAULT FOUND AREA UNDER OVEN COMPLETELY DIRTY. REPLACED FWD GALLEY NR 2 OVEN.SDR ASMF2016072600008Oven · failedDURING TRANSIT CHECK, SMOKE AND BURNING ODOR WERE DETECTED IN FORWARD GALLEY. MAINTENANCE PERSONNEL PERFORMED SMOKE OR FUMES CONDITIONAL INSPECTION IN CABIN IAW MM 05-51-56 AND AMM 33-26-00 AND AMM 33-29-00, NO ODOR OR SMOKE EVIDENCES WERE FOUND; SO THE OVEN, SDR F3LA2016081700001Coffeemaker · odorF/A SMELLED ODOR COMING FROM AFT CABIN DESCRIBED AS POSSIBLY POPCORN, BURNING RUBBER, OF BURNED COFFEE. POSSIBLY COMING FROM HIGHER IN THE CABIN PERFORMED TROUBLESHOOTING IAW TSM 05-50-00-810-831A. IDENTIFIED THE MOST PROBABLE CAUSE OF THE ODOR TO BE COMING SDR AALA201605219001Coffeemaker · odorAIRCRAFT WAS GNDED. OIL SMELL AFT GALLEY DURING CRUISE. SMELL CEASED AFTER COFFEE BREWERS SHUTDOWN. ACCOMPLISHED TASK CARD 26L00021001, CONFIRMED CAUSE OF ODOR TO BE AFT GALLEY COFFEEMAKER. OPERATION OF ENG 1 & 2 BLEED SYS & APU BLEED SYS DID NOT PRODUCE OSDR F3LA2016052000048Coffeemaker · dirtyREFERENCE LOG PAGE 989574, DURING CRUISE THE CREW NOTED AN ODOR COMING FROM THE AFT CABIN & THE ACFT DIVERTED. MX IDENTIFIED THE CAUSE OF THE ODOR TO BE THE AFT GALLEY COFFEE MAKER & FOUND BURNT DRIED COFFEE RESIDUE ON AFT GALLEY COFFEE MAKER. MX CLEANED & ISDR AALA201605209001Chiller · odorAIRCRAFT WAS NOT GNDED. AFT GALLEY CART REFRIGERATION CYCLES ON TO OFF. ELEC BURN ODOR PRESENT IN AFT GALLEY. REPLACED AFT GALLEY CHILLER & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 25-34-51-0401.SDR DALA2016051603969Oven · odorDURING FLIGHT AN ELECTRICAL ODOR FROM THE FIRST CLASS OVEN OCCURRED. CIRCUIT BREAKER CYCLED ONE TIME. STILL INOPERATIVE. ACFT DIVERTED. MAINTENANCE PULLED OVEN AND INSPECTED CONNECTOR AND WIRING. NO TROUBLE FOUND. FORWARD OVEN TO NEF 25-34-02. SUBSEQUENTSDR AALA201605159006Oven · dirtyAIRCRAFT WAS NOT GNDED. AFT GALLEY NR 1 OVEN SMOKED BADLY WHEN USED. BACK HEATING ELEMENT APPEARS TO NEED TO BE CLEANED. R & R OVEN OPERATIONAL CHECKED GOOD.SDR DALA2016051603985Oven · smokeRETURN TO BLOCK DUE TO, ON TAXI OUT, F/A ADVISED A SMOKE ODOR FROM FIRST CLASS OVEN AFTER BEING TURNED ON. FAINT BURNED ODOR OF FOOD RESIDUE IN COCKPIT. MAINTENANCE VERIFIED SMOKE ODOR CAME FROM FIRST CLASS OVEN. INSPECTED OVEN, NO FURTHER DAMAGE OR SMOKE NOTSDR V0XD20160510094Fitting · corrodedGALLEY 1 LT INBD AFT FOOT IS CORRODED. R & R CORRODED FOOT IAW CMM 25-32-97.SDR DALA2016050503690Oven · smokeCREW REPORTS OVEN 814 SMOKING. RAN OVEN; SMOKES. NOT ELECTRICAL. CLEANED OVEN, NO HELP. R & R OVEN IAW AMM 25-34, OPS CK NORMAL.SDR AALA201605029009Coffeemaker · odorAIRCRAFT WAS NOT GNDED. ELEC SMELL COMING FROM ESPRESSO MAKERS IN MID GALLEY. REPLACED ESPRESSO MAKERS & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR 2016FA0000195Coffeemaker · failedWARMING PLATE ON COFFEE MAKER OVERHEATS. METAL COFFEE POT GETS TOO HOT TO TOUCH. PILOTS COULD SMELL HOT ODOR.SDR ASOA20160425019Unknown · unknownCREW REPORTED THE NR 2 COFFEEMAKER PRODUCED AN ELECTRICAL ODOR AND THE COLD WATER LIGHT WOULD NOT GO OFF. MAINTENANCE PERFORMED OPS CHECK AND COULD NOT DUPLICATE FAULT. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR V0XD201604025075Fitting · corrodedGALLEY 2 HAS ONE CORRODED FOOT. REMOVED CORRODED GALLEY 2 FOOT. INSTALLED SERVICEABLE FOOT IAW AMM 20-21-00.SDR V0XD201604025074Fitting · corrodedGALLEY 1 HAS TWO CORRODED FEET. REMOVED GALLEY 1 CORRODED FEET & DOUBLERS. INSTALLED SERVICEABLE FEET & DOUBLERS IAW CMM 25-33-42.SDR CALA2016041800231Oven · unserviceableDURING CLIMB TO CRUISE ALTITUDE, FLIGHT ATTENDANTS REPORTED SMOKE & BURNING SMELL IN AFT CABIN. BRIEF ACTIVATION OF CSSP SMOKE DETECTION. CONTENTS OF DMC-787-A-05-51-99-99A-282A-A COMPLIED WITH & FORM SENT TO TOMC. SMOKE FUMES INSPECTION COMPLIED WITH IAW DSDR AALA20160426011Coffeemaker · overheatedAIRCRAFT WAS NOT GNDED. DURING CRUISE, AN ELEC ODOR WAS REPORTED IN THE AFT GALLEY. FLIGHT ATTENDANTS TURNED OFF GALLEY POWER & ODOR DISSIPATED. FOUND BOTH AFT GALLEY COFFEE MAKERS APPEARED TO HAVE OVERHEATED. R & R COFFEE MAKERS & ACCOMPLISHED OPERATIONALSDR AALA20160426010Coffeemaker · overheatedAIRCRAFT WAS NOT GNDED. DURING CRUISE, AN ELEC ODOR WAS REPORTED IN THE AFT GALLEY. FLIGHT ATTENDANTS TURNED OFF GALLEY POWER & ODOR DISSIPATED. FOUND BOTH AFT GALLEY COFFEE MAKERS APPEARED TO HAVE OVERHEATED. R & R COFFEE MAKERS & ACCOMPLISHED OPERATIONALSDR CALA2016040400207Oven · smokeOVEN 708 BEGAN SMOKING WHEN TURNED ON. OVEN WAS QUICKLY TURNED OFF. ELEMENT ON REAR OF OVEN WAS BURNT. NO EVIDENCE OF SMOKE FOUND. OVEN DEACTIVATED TO PULL CB. PLACED ON PLACARD IAW 2500BR.SDR AALA201604019007Oven · odorAIRCRAFT WAS GNDED. AFTER ENG START SMELLED CHEMICAL, LIKE CHLORINE, SMELL THROUGH A/C. SMELL WENT AWAY ON TAXI OUT & CAME BACK ON CLIMB OUT, THEN WENT AWAY AGAIN. FLIGHT CREW EXPERIENCED BURNING SENSATIONS & SORENESS IN THE NOSE & THROATS, NAUSEA & HEADACHSDR AALA20160324011Oven · dirtyAIRCRAFT WAS GNDED. AIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT WAS OVERWEIGHT. DURING CLIMB A VERY STRONG ELEC ODOR WAS REPORTED THROUGHOUT THE ENTIRE ACFT. GALLEY POWER WAS SHUT OFF. PLACED GALLEY OVEN ON MEL. CABIN CLEANERS CLEANED FWD OVEN
Back to JASC 2530