SDR AALA201603229010Coffeemaker · defectiveAIRCRAFT WAS NOT GNDED. ESPRESSO MAKER NR 2 SMELLS LIKE ELEC SMOKE WHEN IN USE. REPLACED ESPRESSO MAKER NR 2 & ACCOMPLISHED A SATISFACTORY LEAK & OPERATIONAL CHECK IAW AMM 25-35-15-000-802-A & 25-35-15-400-802-A.SDR ASMF201605007Oven · defectiveAIRCRAFT RETURNED TO PLATFORM DUE TO AFTER ENGS START, SMOKE WAS DETECTED IN AFT GALLEY. PERFORMED SMOKE OR FUMES IN CABIN CONDITIONAL INSPECTION IAW MM 05-51-56 & FIM 21-00 TASK 806 PROCEDURE, DETECTING SMOKE IN THE OVEN NR 1 IN AFT GALLEY, SO THE OVEN NR 1 SDR SIMA20160311001Drain · dirtyCLIMBING THROUGH 12,000 FT, FLIGHT ATTENDANT 1 REPORTS AN UNUSUAL NOISE EMANATING FROM GALLEY AREA. COULD HEAR IT OVER THE INTERCOM BUT DIDN’T HEAR ANYTHING BEFORE THE CALL. THE NOISE CAUSED THE FLIGHT ATTENDANT TO STATE THAT HE FELT UNSAFE. NOISE STOPPED ASDR AALA201603099007Oven · defectiveAIRCRAFT WAS NOT GNDED. NR 1 OVEN IN MID GALLEY HAS HOT ELEC SMELL. REPLACED OVEN & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR SWAA2016031049782Coffeemaker · faultyDURING TAKEOFF FLIGHT ATTENDANT REPORTED STRONG ELEC ODOR. R & R AFT INBD COFFEE MAKER IAW MM.SDR YENA20160308224Coffeemaker · failedNR 2 FWD COFFEEMAKER HAD SMOKE F1, TURNED OFF COFFEEMAKER AND SMOKE WAS GONE, SHE THEN NOTIFIED US; PERFORMED FIM TASK 25-30-00-810-801A, NO DAMAGE NOTED. R & R NR 2 COFFEEMAKER, OUTBD AS REQUIRED. AMM 25-30-00, OPS CHECK OK ACFT OK TO CONTINUE SERVICE. NO SDR YENA20160308223Coffeemaker · smokeREF ABOVE ITEM NR 1 SMOKE, REMOVE NR 1 COFFEEMAKER INBD AS PRECAUTIONARY; R & R NR 1 COFFEEMAKER INBD AS REQUIRED, OPS CHECK OK, NO SMOKE NOTICED AFTER BREWING TWICE. ACFT OK TO CONTINUE AMM 25-30-00.SDR YENA20160303216Coffeemaker · failedBURNED PLASTIC ODOR COMING FROM THE FRONT GALLEY COFFEEMAKERS. R & R COFFEEMAKER IAW AMM 25-30-00. OPS CHECKED GOOD. ACFT OK FOR SERVICE.SDR AALA20160303003Oven · contaminatedDURING FLIGHT, WHILE USING THE OVENS, A GRAY SMOKE ALONG WITH A STRONG, ACRID ODOR BECAME PRESENT. THE FLIGHT ATTENDANT TURNED OFF THE OVENS & THE SMOKE DISSIPATED. THE FLIGHT CONTINUED WITHOUT FURTHER INCIDENT. CLEANED OVENS. PERFORMED OPERATIONS CHECK IASDR AALA201602289001Coffeemaker · sparksAIRCRAFT WAS NOT GNDED. AFT GALLEY INBD COFFEE MAKER PRODUCED ELEC SPARK WHEN USED. PULLED CB, R & R AFT INBD COFFEE MAKER. ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201602249008Air Filter · cloggedAIRCRAFT WAS GNDED. SHORTLY AFTER TAKEOFF ONE OF THE FLIGHT ATTENDANTS BEGAN TO SMELL A METALLIC & OILY SMELL IN THE CABIN. THE SMELL BEGAN TO GIVE THE FLIGHT ATTENDANT A HEADACHE. NONE OF THE PAXS ONBOARD EXPERIENCED ANY NEGATIVE EFFECTS FROM THE ODOR. A SDR Z2KR201601Microwave Oven · smokeINVESTIGATION FOUND THAT THE HIGH VOLTAGE OUTPUT CAPACITOR, APPEARED TO HAVE INITIALLY FAILED. IT EXHIBITED EXTREME HEAT DAMAGE. THIS FAILURE COULD NOT BE REPRODUCED UNDER LABORATORY CONDITIONS. THE BUILT-IN THERMAL PROTECTION OF THE MICROWAVE AND THE DESIGSDR CALA2016022495134Oven · contaminatedBUS CLASS GALLEY OVEN 31 SMOKING, CABIN & VENT NOT CLEARING AIR. INADEQUATE STOWAGE OF FOOD IN THE TOP SHELF, FOOD TRAYS STOWED WITHOUT LID. LED TO CONTAMINATION WITH CINNABON ON THE GRILL THAT PROTECTS THE FAN & HEATER ELEMENT. TOP OF THE OVEN CLEANED AS PSDR CALA2016022495123Oven · dirtyBURNING PLASTIC SMELL IN AFT GALLEY. TURNED OFF OVENS & COFFEE MAKERS NO SMOKE. FOUND PLASTIC WRAPPER MELTED IN BACK OF OVEN RACK. REMOVED OVEN HEAT SHIELD, REMOVED DEBRIS & CLEANED, NO ODOR PRESENT.SDR Z2KR201602230001Microwave Oven · smokeACFT MFG HAS NOTIFIED ZODIAC EXECUTIVE ACFT INSERTS THAT MICROWAVE OVEN PN 910-0011-01, SN 15-06-02313 WAS INVOLVED IN A SMOKE EVENT ON BOARD AIRCRAFT. FURTHER INVESTIGATION IS IN PROGRESS.SDR DXTA2016022106187Microwave Oven · failedMICROWAVE OVEN BEGAN TO SMOKE WHILE IN USE AT FL360. AFTER DECLARING AN EMER & PRESSING THE GALLEY & MICROWAVE OVEN DISABLE SWITCH LIGHTS, SMOKE CONTINUED TO EMIT FROM THE MICROWAVE FOR REMAINDER OF FLIGHT. UPON POST FLIGHT INSPECTION BY FIRE CREW, MICROWAVESDR AALA201602249013Oven · smokeAIRCRAFT WAS NOT GNDED. FWD GALLEY OVEN 1 SMOKES. REPLACED OVEN & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 25-33-19.SDR AALA201602229016Oven · odorAIRCRAFT WAS NOT GNDED. FWD GALLEY RT SIDE OVEN HAS A VERY STRONG ODOR WHEN BEING USED. REPLACED FWD GALLEY NR 2 OVEN IAW AMM 25-35-19.SDR AALA201602229002Oven · defectiveAIRCRAFT WAS GNDED. FLIGHT ATTENDANT REPORTED A STRONG ODOR IN THE FWD CABIN DURING TAKEOFF & LANDING, THAT CAUSED BURNING EYES, IRRITATED THROAT & A METALLIC TASTE IN THE FLIGHT ATTENDANTS MOUTH. ACCOMPLISHED JC 33L00021001, REPLACED 2 EACH OVENS & ALL 8 HESDR YENA20160220122Coffeemaker · odorCLIMBING THRU 1200 INFLIGHT, CALLED SAYING THEY SMELLED ELECTRICAL SMOKE TOLD THEM TO TURN OFF COFFEE POTS, 508, WAS ONLY POT ON. WE WERE IN MILD TURBULENCE. ODOR CLEARED OUT AFTER COFFEE POT WAS TURNED OFF. R & R COFFEEMAKER NR 508 IAW AMM 25-35-15. INSPECSDR DALA2016022301388Oven · smokeDURING CRUISE, F/A REPORTED OVEN SMOKE. GALLEY POWER REMOVED. SMOKE CEASED. MAINTENANCE TROUBLSHOT. FOUND NO SMOKE OR BURNING. FORWARD TO MCO, PLAC IAW MEL 20FEB MSP MAINTENANCE OPERATED AND TESTED GALLEY OVEN. OPS CHECKS OK. PLACARD REMOVED.SDR REXA2016021600204Coffeemaker · faultyNUMBER 1 COFFEE MAKER WAS SPARKING IN FLIGHT. FLIGHT ATTENDANT CALLED DURING DESCENT, SHE SAID THE COFFEE MAKER HAD BEEN OFF FOR ABOUT 10 MINS. ALSO WAS A BURNING SMELL AS WELL, SHE PULLED THE BREAKER AFTER TALKING WITH US & THAT ISOLATED THE PROBLEM. DEFERSDR DALA2016021201040Oven · odorCREW NOTICED A BURNING ODOR IN THE FORWARD CABIN. F/A ALSO REPORTED AN ELECTRICAL BURNING ODOR AND FOOD ON THE FIRST CLASS OVEN ELEMENT. F/A TURNED THE OVEN OFF AND PULLED THE CIRCUIT BREAKER. MAINTENANCE FOUND EVIDENCE OF BURNED FOOD INSIDE OVEN. INSPECTESDR MASA2016021012750Coffeemaker · odorELECTRICAL ODOR IN GALLEY AREA, NO SMOKE. PLACED COFFEEMAKER ON MEL.SDR AALA20160212006Coffeemaker · overheatedELECTRICAL ODOR IN FIRST CLASS GALLEY. CAPPUCCINO MAKER APPEARS OVERHEATED. DEACTIVATED THE CAPPUCCINO MAKER & FIRST CLASS EMER POWER. NO EMER WAS DECLARED & FLIGHT CONTINUED. THE FLIGHT LANDED WITHOUT FURTHER INCIDENT. REMOVED CAPPUCCINO MAKER & NOTICED SDR REXA2016020600133Oven · defectiveSMOKE FWD LAVATORY WENT OFF AT FL 370. SUSPECT FROM OVEN. NO SIGN OF SMOKE. REMOVED ALL OLD PAPER & DEBRIS FROM BEHIND THE OVEN. DUPLICATED FAULT WITH OVEN IN HIGH & WARMED UP, OPENED DOOR & RECEIVED MSG. REPLACED THE OVEN ASSEMBLY & ALL THE COOKING SHELVSDR BT7Y2016021200086Coffeemaker · defectiveDURING REPAIR, A HEATING ELEMENT CONNECTION WAS FOUND TO BE DETACHED DUE TO ELECTRICAL ARCING AND OVERHEATING. OTHER BEVERAGE MAKERS OF THE SAME TYPE WERE INSPECTED AND 5 OF THE 20 WERE FOUND TO EXHIBIT OVERHEATING TO DIFFERENT DEGREES. WHEN TESTED ON THE BESDR CA160121019Coffeemaker · damaged(CAN) NR 2 COFFEE MAKER OVERHEATED CAUSING MELTING DAMAGE TO BASE. HEAT MELTED A 3 INCH DIAMETER HOLE IN BASE.SDR CA160121017Oven · faulty(CAN) DURING CRUISE, FLT ATTENDANT EXPERIENCE ELECTRIC ACRID SMELL COMING FROM THE AFT GALLEY. FURTHER INVESTIGATION REVEALED THAT SMOKE WAS COMING FROM NR 4 OVEN. THE FLIGHT CREW WAS ADVISE, THE BREAKERS WERE PULLED AND THE GALLEY POWER WAS INTERRUPTED. THE SDR ASOA20160119006CCoffeemaker · odorTHE CREW REPORTED A BURNING ODOR FROM THE COFFEE POTS. MAINTENANCE INSPECTED AND FOUND ELECTRICAL RESET NO LONGER ATTACHED TO TOP OF COFFEE BREWER. THE NR 1 COFFEE BREWER WAS REPLACED AND OPS CHECKS WERE GOOD.SDR CALA2016011800055Galley · power lossLOST ALL GALLEY & LAVATORY POWER, AIRBORNE. NOTICED BURNING SMELL IN AFT GALLEY. FLIGHT DECK INDICATIONS NORMAL. ACCOMPLISHED FIM TASK 25-31-00-810-801 BPCU BITE, NO FAULTS, OPERATIONS TEST MM TASK 24-21-00-700-803, NO FAULTS. IAW MFG FLEET TEAM DIGEST ARTSDR DALA2016011100166Oven · odorFUME CREW REPORTS SMOKE AND ODOR FROM THE F/C OVEN. OVEN WAS TURNED OFF, THE CIRCUIT BREAKER WAS PULLED AND SMOKE, ODOR SUBSIDED. MAINTENANCE FOUND OVEN TO BE THE CAUSE OF THE ODOR. REPLACED THE OVEN IAW AMM 25-34. AIRCRAFT RETURNED TO SERVICE.SDR UIEA2016010800005Oven · dirtyOVEN SMOKES EXCESSIVELY WHEN IN OPERATION. CLEANED OVEN & OPERATES NORMAL IAW MM 25-32-00.SDR ASOA2016010600002Beam · corrodedDURING C-CHECK, BAGGAGE DOOR CUTOUT LOWER BEAM HAS CORROSION FRAME 65-68. R & R BAGGAGE DOOR CUTOUT LOWER BEAM FRAME 65-68 IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR AALA20160113003Oven · faultyAIRCRAFT WAS GNDED. DURING FLIGHT A STRONG ELEC SMELL WAS REPORTED IN THE 1ST CLASS, FWD GALLEY & COCKPIT AREAS. FOUND 1ST CLASS OVEN EMITTING STRONG ELEC ODOR. R & R OVEN IAW AMM 25-39-03. OPERATIONAL CHECKED NORMAL.SDR YENA20151231675Coffeemaker · odorRIGHT FORWARD GALLEY COFFEEMAKER HAS AN ELECTRICAL ODOR, TURNED OFF SYSTEM AND ODOR DISSIPATED. OPERATIONAL CHECKED FORWARD COFFEEMAKER. OPERATIONAL CHECKED GOOD. NO ODORS NOTED.SDR YENA20151230674Coffeemaker · failedLEFT FORWARD GALLEY COFFEEMAKER HAS AN ELECTRICAL ODOR. TURNED OFF SYSTEM AND ODOR DISSIPATED; R & R FORWARD COFFEEMAKER IAW AMM 25-35-00. OPS CHECK GOOD.SDR YENA20151221660Coffeemaker · failedAIR TURNBACK, 1 FORWARD COFFEEMAKER BAG EXPLODED FROM TRAY AFTER COFFEEMAKER WATER BOILED OVER. R & R FORWARD GALLEY COFFEEMAKER NR 1.SDR YENA20151218659Coffeemaker · odorACFT DIVERTED. ODOR IN AFT GALLEY. PULLED CIRCUIT BREAKERS TO COFFEEMAKERS WITH NO EFFECT. NOTED ODOR AT AFT GALLEY CIRCUIT BREAKER PANEL SO SECURED GALLEY/CABIN POWER FROM FLIGHT DECK. ODOR DISSIPATED. ELECTRICAL ODOR INSPECTION PERFORMED. DURING COFFEEMASDR CALA2015121700995Galley · dirtyAT APPROX FL 34O, FLIGHT ATTENDANTS REPORTED A STRONG SWEET ODOR IN CABIN & FEELING LIGHT HEADED, BEGAN TO NOTICE ODOR IN COCKPIT. DECIDED TO RETURN. RAN ENGINES 70 PERCENT N1 PRESSURIZED TO 4 PSI SWAPPED PACKS. REMOVED COFFEE MAKERS & OVENS, FOUND RESIDUE.SDR ASOA20151215072CSCoffeemaker · failedSUP: THE CREW REPORTED SMOKE IN THE CABIN GALLEY AREA. MAINTENANCE REPLACED THE NR 1 COFFEE BREWER. OPS CHECKS WERE GOOD.SDR AALA20151214002Coffeemaker · faultyAIRCRAFT WAS NOT GNDED. COFFEE MAKER 12 WAS NOT BREWING & ELEC BURNING ODOR OCCURRED. CB PULLED FOR COFFEE MAKER 12. R & R COFFEE MAKER & PERFORMED OPERATIONAL CHECK IAW AMM 25-32-00. SYS CHECKED NORMAL.SDR CA151211007Oven · arced(CAN) 4 TO 5 MINUTES AFTER OVENS WERE TURNED ON AN ELECTRICAL ODOR WAS REPORTED IN THE AFT GALLEY AREA. OVENS AND GALLEY POWER TURNED OFF, CIRCUIT BREAKERS POPPED, COMPLETE GALLEY SHUT DOWN. RESOLUTION FOUND OVEN 808 FUSE BLOWN ON CONTROLLER AND ARCING INSIDSDR SWAA2015120346663Coffeemaker · faultyDIVERSION, AFT LAVATORY SMOKE DETECTOR GOING OFF INFLIGHT. R & R NR 2 AFT COFFEE MAKER IAW MM.SDR AALA201512029009Coffeemaker · defectiveAIRCRAFT WAS NOT GNDED. RIGHT AFT COFFEE MAKER, RIGHT SMELLS HOT & PULLED BREAKER. SMOKE & SMELL DISSIPATED. REPLACED RIGHT AFT COFFEE MAKER. ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 25-35-15.SDR AALA201512029002Coffeemaker · defectiveDIVERTED & ACFT WAS NOT GNDED. FLIGHT ATTENDANT REPORTED BURNING SMELL FROM AFT GALLEY AREA & FELT FAINT. FLIGHT ATTENDANT TURNED OFF CHILLERS, COFFEE MAKER & WARMERS. THE SMELL WENT AWAY, BUT RETURNED SHORTLY AFTER. REPLACED BOTH AFT COFFEE MAKERS IAW AMMSDR AALA201511309010Chiller · defectiveAFT B GALLEY ELEC ODOR, CHILLER CB`S PULLED ODOR STOPPED. FOUND PAPER TOWEL WAD BLOCKING THE FILTER, REPLACED AFT GALLEY CHILLER & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECKED IAW AMM 25-34-51.SDR CALA2015120400961Oven · odorGATE RETURN FOR OVEN ODOR. PERFORMED AMM 05-51-58 INSPECTION. VERIFIED OVEN 305 AS CAUSE REF 8326266 FOR OVEN 305. MEL FORMS 46-6020 FAXED TO MOC. IAW FORMS NO SMOKE OR BURNING ODOR PRESENT, ONLY OVEN SMELL. INSPECTED OVEN NO OVERHEAT CONDITION NOTICED.SDR CALA2015112000938Oven · shortedFORWARD GALLEY OVEN 204, SHORTED, WITH OVEN TURNED OFF. UTILITY BUSES WERE TURNED OFF & CB PULLED, OVEN THEN COOLED DOWN. PERFORMED SMOKE & ODOR IN FLIGHT DECK & OR CABIN INSPECTION IAW AMM 05-51- 58, NO DEFECTS NOTED. R & R NR 204 & 205 OVENS IAW AMM 25-34SDR AALA20151116002Coffeemaker · odorACRID BURNING SMELL FROM CAPPUCCINO MACHINE. REPLACED CAPPUCCINO MACHINE IAW AMM 25-32-01. ALL OPERATIONS NOW GOOD. GOOD FOR SERVICE. ELEC CONNECTORS AT REAR ALL GOOD.
Back to JASC 2530