Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R61A201511130832Hot Water Pot · contaminatedCREW REPORTED A SMOKE ODOR IN THE AFT CABIN. AN EMERGENCY WAS NOT DECLARED AND CREW LANDED WITHOUT INCIDENT. MAINTENANCE FOUND AFT GALLEY COFFEEMAKER HOT PLATE ON WITH NO BEVERAGE IN THE POT, WHICH CAUSED THE ODOR. MAINTENANCE INSPECTED CABIN AREAS IAW AMM SDR R61A201511110818Coffeemaker · odorCREW REPORTED A BURNING ODOR IN FLIGHT. CREW TURNED OFF COFFEEMAKER AND ODOR WENT AWAY. MAINTENANCE R & R COFFEEMAKER IAW AMM AND OPS CHECKED GOOD.SDR AALA20151104001Chiller · defectiveELECTRIC SMELL IN BUSINESS GALLEY. TURNED OFF FWD CHILLER, SMELL DISSIPATED. THE FLIGHT LANDED WITHOUT FURTHER INCIDENT. ACFT WAS NOT TAKEN OUT OF SERVICE. DEFERRED CHILLER INOPERATIVE IAW NEF 25-34. R & R THE FWD BUSINESS CLASS CHILLER IAW MM 25-33-01. SDR YENA20151030537Coffeemaker · failedCOFFEMAKER NR 2 IN FWD GALLEY SMELLS LIKE ELECTRICAL WHEN ON; R & R COFFEEMAKER, AMM 25-35-15, CHECK NORMAL.SDR QXEA2015102300558Coffeemaker · overheatedELECTRICAL ODOR IN THE AFT GALLEY AN APPROACH. THE GALLEY HOT JUG WAS FOUND TO BE EXTREMELY HOT. FERRIED FOR REPAIRS. FOUND NO DEFECTS WITH HOT JUG CONNECTIONS. NO DEFECTS IN GALLEY BULBS INSTALLED. FOUND NO DEFECTS WITH GALLEY ELECTRICAL PANEL. REPLACEDSDR GR422015102100001Microwave Oven · burnedMICROWAVE WAS BEING OPERATED EMPTY AND STARTED EMITTING A BURNING ODOR. UNIT SHUTOFF AND DEACTIVATED BY PULLING CIRCUIT BREAKER. EVIDENCE OF SCORCHED PAINT ON RIGHT INTERIOR SIDE OF OVEN AREA. NOTIFICATION OF THE INCIDENT RECEIVED ON 11/5/15.SDR AALA20151019001Chiller · odorSTRONG ELEC BURNING ODOR IN CABIN ON DESCENT. HE ODOR DISAPPEARED WHEN THE UTILITY BUSSES WERE DISCONNECTED. THE AFT GALLEY RT CHILLER WAS MORE HOT THAN AFT LT CHILLER & THE AFT RT CHILLER CB KEPT POPPING OUT. R & R AFT GALLEY RT CHILLER IAW MM 25-33-02. OSDR ASOA20151017059CUnknown · odorTHE F/A NOTICED A SLIGHT BURNING ODOR COMING FROM ABOVE THE COFFEEMAKERS. MAINTENANCE INSPECTED AND REPLACED THE NR 1 COFFEEMAKER. OPS CHECKS WERE GOOD.SDR 2DYA20151006001Oven · dirtyDURING LANDING THERE WAS A STRONG SMELL OF BURNING CANDLES COMING FROM AROUND THE FWD R1 DOOR. ACFT LANDED & ARRIVED TO GATE WITHOUT FURTHER INCIDENT. FOUND THE SMELL COMING FROM THE NR 2 & 3 OVENS. THE OVENS WERE CLEANED IAW AMM 25-05-03. OPERATIONAL CHECSDR A6WA201543086Heater · faultyREQUEST INSPECTION FOR UNUSUAL ODOR IN GALLEY AREA, SMELLS SLIGHTLY LIKE BLEACH. INVESTIGATED & FOUND RT BALLAST FOR GALLEY LIGHTS CREATED AN ODOR THAT NOW HAS PERMEATED THE INSULATION ABOVE THE BALLAST. INSPECTED BALLAST & INSULATION, FOUND NO DEFECTS WITH SDR CA150927008Coffeemaker · overheated(CAN) FLIGHT 8921 SHORTLY AFTER DEPARTURE, THE AFT R/H COFFEE MAKER STARTED SMOKING AND BLEW THE CIRCUIT BREAKERS. SINCE THE ACRID SMOKE SEEMED TO BE CONTINUING, THE CREW DECIDED TO RETURN TO DEPARTURE AIRPORT. THE SMOKE THEN STARTED LESSENING AND DISSIPATING.SDR V0XD20150923194Fitting · corrodedGALLEY 1 HAS 2 CORRODED FLOOR FITTINGS. R & R GALLEY 1 FLOOR FITTINGS PN CDSP2019-7C-760 IAW AMM 25-33-42.SDR ASOA20150922073Coffeemaker · odorTHE CREW REPORTED THAT THE LT COFFEEMAKER SMELLS LIKE ELECTRICAL WIRES BURNING WHILE IN OPERATION, AND THAT IT COULD BE ASSOCIATED WITH ALL THE WATER LEAKING OUT OF THE RT COFFEE POT. THE CREW PLACED THE COFFEE POTS ON NEF-GL-01, AND THE ACFT WAS APPROVED FORSDR AALA20150920001Coffeemaker · failedFLIGHT ATTENDANT REPORTED ELEC SMELL IN AFT GALLEY, THEN DISSIPATED. LT & RT RECIRCULATION FANS, IFE & COFFEE MAKERS CHECKED OK. FOUND INTERNAL FAN ON COFFEE MAKER NR 5 TO HAVE FAILED. REPLACED COFFEE MAKER NR 5 IAW AMM 25-32-00. OPERATIONALLY CHECKED GOODSDR AALA20150916009Oven · dirtyDURING TAKEOFF FLIGHT ATTENDANTS NOTICED A BURNING SMELL FROM AN OVEN. A BURNING PIECE OF PAPER WAS FOUND ON THE OVEN ELEMENTS. FLAMES EXTINGUISHED WITH HALON. R & R OVEN IAW AMM 25-35-19.SDR AALA201509099008Container · dirtyEN-ROUTE, FLIGHT 1832 REPORTED A CABIN ODOR RESEMBLING ROTTEN EGG SMELL. THE ODOR WAS IN THE VICINITY OF 1R DOOR. THE SMELL WAS SO STRONG THAT THE A FLIGHT ATTENDANT WAS PUT ON O2 & THE COCKPIT CREW REQUESTED PARAMEDICS MEET THE ACFT UPON LANDING. ACCOMPLISSDR DALA2015090505464Oven · smokeFWD GALLEY OVEN EXPERIENCED AN ELECTRICAL BURNING ODOR AND FAINT BLUE SMOKE AT ONE POINT. MAINTENANCE INSTALLED A SERVICEABLE OVEN. TESTED GOOD, NO SMOKE NOTED. OVEN STAYED STEADY AT PRESET TEMP.SDR AALA20150909018Chiller · faultyWHILE PARKED AT THE GATE, THE FLIGHT ENCOUNTERS A BURNING ELEC ODOR IN THE AFT GALLEY. THREE FLIGHT ATTENDANTS REPORTED INHALING FUMES, SHORTLY AFTER THEY EXPERIENCED NAUSEA, HEADACHE & DIZZINESS. R & R AFT CHILLERS IAW AMM 25-33-02.SDR V0XD20150831169Fitting · corrodedTHREE CORRODED FLOOR FITTINGS ON GALLEY 1. R & R THREE FLOOR FITTINGS PN CD8P2019-7C-760, PN CDSP2019-7C-760 & PN A661091-1 IAW CMM 25-33-42.SDR AALA20150829004Coffeemaker · faultyG1 GALLEY COFFEE MAKER NR 1, SPARKS & POPPED ITS ASSOCIATED CB. R & R COFFEE MAKER IAW AMM 25-32-00.SDR R61A201508290563Coffeemaker · failedF/A NOTICED SMOKE COMING FROM BOTTOM OF COFFEEMAKER. F/A TURNED POWER TO COFFEEMAKER OFF AND SMOKE STOPPED. CREW CONTACTED MAINTENANCE CONTROL AND CONTINUED TO DESTINATION WITH NO FURTHER ISSUES. MAINTENANCE R & R COFFEEMAKER IAW AMM AND OPS CHECKED GOOD.SDR AALA201508289016Oven · smokeFLIGHT 1848 EN-ROUTE, FWD GALLEY OVEN SMOKES WHEN TURNED ON. ITEM CHECKED & APPROVED FOR NEF 25-33A, FWD GALLEY OVEN INOPERATIVE. ENTERED ON MIC SHEET. REFER TO NEF 25-33A CONTROL 2776N25. REPLACED FWD GALLEY OVEN AMM 25-35-19-000 400-003A. OK FOR SERVICESDR AALA201508289015Element · contaminatedFLIGHT 1930 EN-ROUTE, FWD OVEN HAS PLASTIC RESIDUE ON BURNER ELEMENT, SMOKES BADLY NEEDS CHANGE OUT. CATERING REPLACED OVEN CONTAINER. OPERATIONS CHECKED GOOD.SDR CA150824003Coffeemaker · failed(CAN) SMOKE WAS DISCOVERED IN THE FORWARD GALLEY. CREW WAS JUST IN THE PROCESS OF RECEIVING THEIR ATC CLEARANCE. THE CREW DECLARED MAYDAY AND PROCEEDED TO THE NEAREST AIRPORT. THE FLIGHT LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE IS INVESTIGATING THE CAUSESDR USAA2015F00093Oven · abnormalFWD RT & LT OVENS HAD PEANUTS IN THE BOTTOM FOR THE OVENS NEAR THE HEATING ELEMENT THAT CAUGHT FIRE AND CREATED SMOKE CAUSING THE ACFT TO RETURN TO THE FIELD AND A FIRE EXTINGUISHER TO BE USED.SDR AALA201508199009Oven · defectiveFLIGHT 750 EN-ROUTE, DURING CLIMB, AT APPROX FL 290, BOTH PILOTS SMELLED A FAINT ODOR OF SMOKE IN THE FLIGHT DECK. THAT WAS WHEN IT WAS NOTICED IN THE FWD GALLEY NR 1 OVEN, AN INFLIGHT FIRE WITH AN ELEC SMOKE ODOR IN THE CABIN & FLIGHT DECK. THE FIRE WAS CONSDR AALA201508189013Oven · odorFLIGHT 579 EN-ROUTE, FWD GALLEY OVEN EMITS ODORS WHEN USED, UNSUITABLE FOR FOOD SERVICE. R & R FWD GALLEY OVEN IAW AMM 25-35-19. OPERATIONS CHECKED GOOD.SDR AALA201508139003Coffeemaker · defectiveFLIGHT ATTENDANT REPORTED SMOKE IN AFT GALLEY. FIRE DEPARTMENT PERSONNEL CONFIRMED SMOKE WAS VISIBLE IN THE GALLEY, BUT THERE WERE NO FLAMES. ACCOMPLISHED THE CABIN AIR QUALITY TROUBLESHOOTING, INSPECTED ALL ITEMS RELATED TO REAR GALLEY & LAVATORIES. REPLACSDR CA150828010Ribbon Heater · overheated(CAN) DURING AN INSPECTION, THE OPERATOR NOTICED THAT THE INSULATION INSTALLED OVER THE HEATED SILICONE GALLEY DRAIN HOSE (INSTALLED BY MODIFICATION DATA SUMMARY D48100) SHOWED SIGNS OF OVERHEATING. AFTER REMOVING THE INSULATION, IT WAS DISCOVERED THAT THE RIBSDR CALA2015081194196Coffeemaker · malfunctionedFORWARD GALLEY WORK LIGHT, CB TRIPPED G2, ELEC ODOR NOTICED. NOTE FWD GALLEY WORK LIGHT IS DEACTIVATED & COLLARED BLACK. FOUND ELEC ODOR COMING FROM FWD GALLEY COFFEE MAKER. REPLACED COFFEE MAKER, CHECKED OK.SDR AALA201508119003Oven · defectiveCABIN SMOKE COMING FROM OVEN 1 - 4. REPLACED OVEN 1 - 4. ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 25-33-00.SDR CA150807008Coffeemaker · smoke(CAN) DURING FLIGHT, A STRONG ELECTRICAL BURNING ODOR DETECTED IN FWD GALLEY. GREY AND THIN SMOKE FOUND COMING FROM BREWER BELOW STOWAGE. BREWER POWER TURNED OFF AND CIRCUIT BREAKERS PULLED, SMOKE DISSIPATED VERY QUICKLY. BREWER REMOVED AND SENT FOR REPAIRSDR AALA201508039002Chiller · odorFLIGHT 895 EN-ROUTE, FLIGHT ATTENDANTS REPORTED STRONG HOT ELECTRICAL SMELL IN AFT GALLEY. AC LEFT SMELL SEEM TO DISSIPATE WHEN AFT CHILLER WAS TURNED OFF. R & R AFT CHILLER IAW AMM 25-34-51.SDR AALA201508039001Coffeemaker · faultyFLIGHT 735 EN-ROUTE, AFT GALLEY SMOKE VISIBLE IN FLIGHT. SMOKE APPEARED ABOVE COFFEE MAKER ON RIGHT SIDE, SMELL OF SMOKE COMING THROUGH LEFT VENT. CB'S PULLED IN AFT GALLEY. REPLACED AFT GALLEY RIGHT COFFEE MAKER 1 IAW MM 25-33-15 PB 401. OPERATIONS CHECKESDR DALA2015073004758Oven · odorELECTRICAL ODOR DURING CRUISE. CHECK LIST COMPLIED WITH, ODOR DISSIPATED AFTER GALLEY POWER TURNED OFF. IDENTIFIED OVEN AS FAULT CAUSE.SDR DXTA2015072706052Oven · smokeAPPROXIMATELY 40 MINUTES INTO FLIGHT, AFTER FLIGHT ATTENDANT STARTED USING OVEN, A STRONG ACRID ODOR ENTERED COCKPIT, ALSO NOTICED A SMOKEY HAZE IN MICROWAVE COMPARTMENT. OVEN USE WAS DISCONTINUED & ODOR DIMINISHED. R & R OVEN ASSEMBLY WITH A REPAIRED UNIT.SDR AALA201507249002Coffeemaker · malfunctionedFLIGHT 660 EN-ROUTE, SHORTLY AFTER TAKEOFF AFT GALLEY ODOR OF BURNING ELEC COMPONENTS, THEN ALL THINGS TURNED OFF IN GALLEY, ODOR NO LONGER PRESENT. MOST NOTICEABLE IN AREA OF COFFEE MAKERS. R & R AFT GALLEY COFFEE MAKERS 1, 2 & 3 IAW AMM 25-35-15. CHECKEDSDR AALA201507249001Chiller · malfunctionedFLIGHT 1798 EN-ROUTE, AFT FLIGHT ATTENDANT REPORTS A SMELL OF BURNING IN THE BACK GALLEY. FWD FLIGHT ATTENDANT ALSO REPORTED UPPPER SIDEWALL HOT & BURNING SMELL. R & R AFT GALLEY CHILLER IAW AMM 24-34-51. NO FAULTS NOTED.SDR DALA2015072204537Coffeemaker · odorELECTRIC BURNING ODOR FROM AFT GALLEY COFFEEMAKER. R & R AFT GALLEY COFFEEMAKER, LT SIDE IAW AMM 25-33-01, OPS CHECKS OK.SDR ASOA20150711036Coffeemaker · leakingSMOKE WAS REPORTED TO BE COMING FROM THE NR 1 COFFEEMAKER IN THE GALLEY. MAINTENANCE INSPECTED AND FOUND NR 1 COFFEEMAKER LEAKING STEAM NOT SMOKE. R & R NR 1 COFFEEMAKER WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR AALA201507139015Coffeemaker · shortedAFT COFFEE MAKER NR 2 POPS CB, SMELLED LIKE ELEC BURNING. REPLACED AFT GALLEY NR 2 COFFEE MAKER IAW CMM 25-35-15. OPERATIONS NORMAL.SDR WX0A2015070972726Oven · odorFLIGHT ATTENDANT REPORTS GALLEY OVEN CREATED A BURNING ELEC SMELL. ONCE OVEN TURNED OFF, SMELL WENT AWAY. DEFERRED OVEN IAW NEF 25-03A-01, CAT D, EXP 11/5. NEF LOG UPDATED.SDR SWAA2015070241278Coffeemaker · faultyDIVERSION & DECLARED EMER. FLIGHT ATTENDANTS REPORTED ELEC FUMES IN THE AFT GALLEY. R & R AFT COFFEE MAKER IAW MM.SDR SWAA2015070241277Coffeemaker · faultyDIVERSION & DECLARED EMER. FLIGHT ATTENDANTS REPORTED ELEC FUMES IN THE AFT GALLEY. R & R AFT COFFEE MAKER IAW MM.SDR ASOA20150604028RCoffeemaker · inoperativePILOT REPORTED STRONG ELECTRICAL SMELL IN GALLEY ASSOCIATED WITH USE OF F/O SIDE COFFEE POT. MAINTENANCE CLEANED NR 2 COFFEE TRAY AND DRAINS THEN R & R NR 1 COFFEE BREWER WITH OPS CHECK GOOD. NO SMELL NOTED. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR AALA201506019004Oven · defectiveFLIGHT 868, EN-ROUTE FIRST CLASS OVEN NR 2 CB PULLED IN FLIGHT. OVEN SMOKING & METAL ELEMENTS SPARKING. REPLACED THE FWD GALLEY NR 2 OVEN.SDR CALA2015052900460Oven · defectiveCIRCUIT BREAKER FOR GALLEY B OVEN PULLED AFTER ELEC SMELL DETECTED FOLLOWING USE. IN FLIGHT TIME 5:30, OVEN SMOKE WENT AWAY AFTER TURNING OFF. PLACED ON PLACARD. INSPECTED CONNECTOR BEHIND OVEN 410, NO PROBLEM NOTED, FOUND OVEN DEFECTIVE.SDR CALA2015052900456Oven · unserviceableOVEN 413 IN AFT GALLEY PRODUCED WHITE SMOKE AT START-UP, FLIGHT ATTENDANT DISCONTINUED USE. R & R OVEN 413 AFT GALLEY. OPERATIONS CHECKED SEVERAL TIMES. OPERATIONS CHECKED NORMAL & NO SMOKE NOTED. AMM REF 25-34-00-000-801C3 & 25-34-00-400-801C1.SDR AALA201505209003Oven · odorFLIGHT 594 EN-ROUTE, GALLEY OVEN HAS ELEC ODOR. WHEN THE FLIGHT ATTENDANT OPENED THE OVEN DOOR, AFTER COOKING MEALS, TO PUT IN THE ROLLS, SHE GOT A STRONG ELEC ODOR IN THE GALLEY. THE SYS WAS DEACTIVATED & WAS DEFERRED VIA NEF PROCESS. REPLACED FWD GALLESDR AALA201505189009Oven · smokeFLIGHT 710, SMOKE CAME OUT OF LT OVEN IN FIRST CLASS WHEN TURNED ON. REPLACED THE LT FWD OVEN.
Back to JASC 2530