SDR CA150520001Oven · failed(CAN) JUST PRIOR TO LANDING, SMOKE AND ELECTRICAL BURNING ODOR WAS OBSERVED COMING FROM THE FWD GALLEY OVEN POSITION (G2). CREW REPORTED THAT IT STARTED 10 MINUTES AFTER THE OVEN WAS SHUTOFF. THE CIRCUIT BREAKER WAS PULLED BY CREW TO REMOVE ELECTRICAL SUPPLY SDR CALA2015051500387Oven · dirtyFOR SDR REPORTING, SDR REPORTED FOR SMOKE FROM OVEN. FOOD RESIDUE, OVEN PLACARDED.SDR AALA20150513001Coffeemaker · odorFLIGHT ATTENDANT REPORTED A BURNING ODOR FROM COFFEEMAKER 2 IN FIRST CLASS GALLEY. R & R THE COFFEEMAKER IAW AMM 25-32-00. SYS CHECKED NORMAL.SDR DALA2015051303276Oven · fumesON FLIGHT, F/A REPORTS THAT GALLEY G1A OVEN HAS "TOXIC FUMES" COMING OUT WHEN OVEN IS ON. DEFERRED IAW NEF 25-34-02. 12MAY, LAX RAN OVEN FOR APPROX 15 MIN, NO ISSUES NOTED. ALL CK'S OK IAW AMM 25-31. NEF REMOVED. OVEN OK FOR SERVICE.SDR CA150519028Oven · smoke(CAN) DURING CLIMB OUT CABIN REPORTED SMOKE OUT OF OVEN NR 3, AFT GALLEY. IT WAS CLASSIFIED AS STEADY, MODERATE, INSIDE OVEN, NOT INCREASING AND NOT INFLUENCING CABIN PAX AREA. FLIGHT RETURNED TO AIRPORT AND PERFORMED A NORMAL LANDING.SDR CALA2015050400367Coffeemaker · sparksREAR RT COFFEE POT HAD SHOWN SPARKS, CB`S IN GALLEY PULLED. FORM 46.6020 COMPLETED BY FLT CREW & ATTACHED. COMPLIED WITH AMM 05-51-58 WITH COFFEEMAKER AT 416 AT FAULT. REPLACED BOTH COFFEEMAKERS 416 & 415 AS PRECAUTION. OPERATIONS NORMAL WITH NO OTHER DISCSDR CALA2015050193648Oven · smokeCREW REPORTS MOMENTARY SMOKE FROM FWD GALLEY OVEN 107, FOOD ODOR. FOOD REMOVED & OVEN NOT USED FOR THE REST OF THE FLIGHT. ACCOMPLISH MM 05-51-56 P201, REMOVED CHOCOLATE CHIP COOKIE DOUGH THAT WAS STUCK TO THE TOP OF THE OVEN, CLEANED AS REQUIRED. CYCLED OVSDR AALA201504309001Chiller · odorFLIGHT 473 EN-ROUTE, FLIGHT ATTENDANT REPORTED MUSTY BAD ODOR WHEN CHILLER IS OPERATING IN AFT GALLEY.SDR DALA2015043003014Coffeemaker · odorWHILE AT 14,000' IN DESCENT, FLIGHT CREW NOTED AN ODOR IN THE COCKPIT ASSOCIATED WITH ELECTRICAL ODOR. WE HAD NO FURTHER INDICATIONS OF THE ISSUE AND THE SMELL DISSIPATED WITHIN 3 MINUTES. MAINTENANCE FOUND A BURNING PLASTIC ODOR COMING FROM GALLEY G1 OVEN. SDR ASOA20150419017Unknown · odorCREW REPORTED A LIGHT ELECTRICAL BURNING ODOR FROM THE RT COFFEEMAKER AND ODOR CLEARED WHEN COFFEEMAKER WAS TURNED OFF. MAINTENANCE PERFORMED OPS CHECK FOR NR 1 COFFEEMAKER WITH NO ODORS NOTED. AC WAS APPROVED FOR RETURN TO SERVICE.SDR AALA201504149003Oven · odorAFT GALLEY ACFT RT OVEN NR 1 EXCESSIVE SMOKE. CB PULLED AS DIRECTED. R & R AFT GALLEY NR 1 OVEN.SDR CALA2015040293499Chiller · faultyON TAXI OUT, JUST PRIOR TO TAKEOFF, HAD A BURNING ELEC SMELL WITH VISIBLE SMOKE NEAR A VENT FACING DOOR 4L. INSPECTED APU AIR SUPPLY DUCT, NO LEAKS PTT7046004. INSPECTED AFT GALLEY CHILLERS & FOUND C52 WITH INCORRECT EXHAUST PORT INSTALLATION PTT7046002. ALSDR UIEA2015032500188Oven · dirtyFIRST CLASS OVEN INOPERATIVE. DEBRIS IN BASE CAUSING SMOKE. REMOVED DEBRIS & CLEANED RESIDUE. OPERATIONS CHECKED GOOD IAW FIM 21-00 TASK 810. NO SMOKE OR SMELL NOTED. IAW AMM 05051056-200-801 SMOKE OR FUMES IN CABIN INSPECTION COMPLIED WITH.SDR R61A201503210207Spigot · corrodedDURING HEAVY CHECK, AFT GALLEY SPIGOT IS CORRODED. MAINTENANCE R & R AFT GALLEY SPIGOT IAW CMM 25-33-55. ACFT REMAINS UNTIL HEAVY CHECK IS COMPLETED.SDR USAA2015032200001Coffeemaker · faultyORIGINATING CREW, POWER UP ACFT ON ARRIVAL. ELEC SMOKE & ARCHING FROM BEHIND FWD GALLEY COFFEEMAKER. REMOVED POWER FROM FWD GALLEY. R & R THE FWD LOWER COFFEEMAKER IAW AMM 25-35-15-400-001. OPERATIONAL CHECKED GOOD.SDR CALA2015032000192Oven · unserviceableAT FL 350 REPORT OF SMOKE & ELEC ODOR IN AFT GALLEY AREA. REMOVED ALL 3 OVENS FROM AFT GALLEY & INSPECTED. FOUND OVEN 412, NR 2 FAN SEIZED & SMELLED INSIDE THE OVEN. R & R 412 OVEN IAW AMM 25-34-00-400-801C3. OPERATIONS NORMAL. ACFT OK TO CONTINUE. ROTABSDR CALA2015032093454Oven · smokeR53 OVEN WAS SMOKING AFTER TAKEOFF. FLIGHT ATTENDANT SAID SMOKE CAME FROM INSIDE OVEN ASSEMBLY DURING WARM UP. REPLACED OVEN, CHECKED OK. REMOVED OVEN PN 2710-0001-01, SN 0091.SDR YENA20150317052Coffeemaker · failedCREW DECLARED AN EMERGENCY DUE TO BURNING SMELL IN ACFT DURING DESCENT AT COCKPIT/CABIN. ACCOMPLISHED TSM INSP/CHK 24-00-00-810-823-A FOUND FWD OTBD C/M TO BE SOURCE OF ODOR, VERIFIED BY F/A NR 1, R & R BOTH FWD C/M'S IAW MM 25-35-15, OPS CHK OK, NO FURTHER OSDR YENA20150317051Coffeemaker · failedCREW DECLARED AN EMERGENCY DUE TO BURNING ODOR IN ACFT DURING DESCENT AT COCKPIT/CABIN. ACCOMPLISHED TSM INSP/CHK 24-00-00-810-823-A FOUND FWD OTBD C/M TO BE SOURCE OF ODOR. VERIFIED BY F/A NR 1 R & R BOTH FWD C/M'S IAW MM 25-35-15, OPS CK OK, NO FURTHER ODOSDR USAA2015031700006Oven · smokeFLIGHT ATTENDANT REPORTED SMOKE FROM FRONT GALLEY OVEN NR 1. R & R NR 1 OVEN IAW AMM 25-35-19-0401-00. GOOD OPERATIONAL CHECK.SDR SWAA2015031737502Coffeemaker · faultyFORWARD COFFEE MAKER EMITTED STRONG ODOR & WAS HOTTER THAN NORMAL. R & R FWD COFFEE MAKER IAW AMM.SDR CALA2015031300164Oven · unserviceableFUMES FROM UNKNOWN SOURCE IN AFT GALLEY AREA, NO OBSERVED SMOKE. GOT PERSISTENT FUMES, RUBBER SMELL FOUND BURNT SUBSTANCE IN OVEN 708. R & R OVEN. OPERATIONS NORMAL. ROTABLE PARTS CHANGE WAS INDICATED. TT 1673745, SN OFF 04441 OVEN, SMALL, ST OFF 29-2532SDR DALA2015031002109Oven · odorON CLIMBOUT A STRONG ELECTRICAL ODOR WAS NOTICED THROUGHOUT CABIN AND COCKPIT IAW SMOKE AND FUMES CHECKLIST. TURNED GALLEY POWER OFF AND ELECTRICAL ODOR DISSIPATED. CONTINUED FLIGHT WITH GALLEY POWER OFF. PERFORMED PNEUMATIC DISTRIBUTION CABIN SMOKE/ODOR TROSDR USAA2015030400003Coffeemaker · defectiveNUMBER 1 COFFEEMAKER SMOKING WHEN TURNED ON. R & R FWD NR 1 COFFEEMAKER IAW MM 25-35-15.SDR CA150223003Coffeemaker · odor(CAN) DURING THE CLIMB AT 4000 FEET, THE FLIGHT ATTENDANT REPORTED A SMOKE ODOR IN THE REAR GALLEY. THE CBÏ¿½S FOR THE COFFEE MAKERS WERE PULLED AND THE SMELL DISSIPATED. THE AIRCRAFT DECLARED AN EMERGENCY AND RETURNED TO THE DEPARTURE AIRPORT. MAINTENANCE INVSDR USAA2015022400002Coffeemaker · smokeMID GALLEY ESPRESSO MAKER 4 - 11 GAVE OFF SMOKE, UNIT WAS SHUT OFF & CB PULLED. UNIT WAS SOMEWHAT LOOSE IN THE RACK.SDR USAA2015022300011Coffeemaker · smokeMID GALLEY ESPRESSO MAKER 4 - 11 GAVE OFF SMOKE, UNIT WAS SHUT OFF & CB PULLED. UNIT WAS SOMEWHAT LOOSE IN THE RACK. REPLACED MID GALLEY ESPRESSO MAKER 4 - 11.SDR SIMA20150221003Hot Water Pot · defectiveHOT JUG BURNING SMELL FOR A FEW SECONDS, THEN WENT AWAY. INSTALLED NEW COFFEE & HUT JUG IN ORIGINAL, INBD, POSITION FOR 30 MINS & CURRENT POSITION, OTBD FOR 15 MINS WITH BOTH PACS RUNNING & RECIRCS ON & OFF WITH NO SMELLS AT THIS TIME.SDR ANCF2015022002Oven · odorINTENSE SHORT CIRCUIT ODOR IN THE CABIN. FLIGHT ATTENDANT REPORTED A GALLEY MAY BE FWD OVEN, STRONG NOISE AT THE SAME TIME. IAW AMM 25-35-19-PB 401 THE OVEN OF GALLEY FWD WAS R & R. OPERATIONAL TEST WAS PERFORMED WITH SUCCESSFUL RESULT & ADDITIONAL TSM AMM SDR DALA2015022301553Oven · smokeDURING CLIMB OUT, F/A NOTIFIED COCKPIT CREW THAT SMOKES WAS COMING FROM THE GALLEY OVEN. THE OVEN WAS TURNED OFF AND THE SMOKE STOPPED AND CLEARED. CREW TURNED OFF GALLEY POWER IAW SMOKE, FIRE, FUMES CHECK LIST. THE FORWARD GALLEY OVEN WAS DEFERRED IAW NEF SDR CALA2015022000112Fluid · leakingLAST FLIGHT HAD TYPE IV FLUID COME IN TO L, R, 1DOORS & SOAK FLOOR. NEED TO CHECK ACCESSORY COMPARTMENT FOR FLUID. INITIATED DIP TO ACCOMPLISH WITHIN 18 MONTHS ECRA 2011-01000, GALLEY SPILL SECT 2 C. HEAVY CHECK SUP INSP IN AREA BETWEEN STATION 301 - 351 & SDR CA150216002Control Module · defective(CAN) DIVERTED DUE TO HOT ELECTRICAL ODOR EMANATING FROM FORWARD GALLEY. NR 2 FWD GALLEY OVEN CONTROL MODULE AND NR 2 OVEN REPLACED AS PER AMM 25-35-19 PB 401.SDR USAA2015021600014Oven · dirtyEN-ROUTE, GALLEY G4B OVEN DEFECTIVE. EMIT SMOKES, SUSPECT GREASE. REPLACED AFT NR 4 OVEN. OPERATIONS CHECKED GOOD.SDR CALA2015021293125Oven · dirtySLIGHT ELEC SMELL IN MID GALLEY ON APPROACH MM 05-51-50. OPERATED MID GALLEY OVENS, CHILLERS, ALL ACFT LIGHTS, ENTERTAINMENT SYS & REMOVED CTR GALLEY CEILING PANELS. THE ONLY SMELL WAS FROM OVEN R32, SPILLED FOOD AT BOTTOM OF OVEN. NO ELEC SMELL DETECTED. SDR CALA2015021293148Motor · odorELECTRICAL ODOR IN SERVICE ELEVATOR SHAFT, DEACTIVATED THE MOTORS IAW MEL. VERIFIED NO EVIDENCE OF ODOR IN ELEVATOR SHAFT EXCEPT MOTORS. THERE IS THE ELEC ODOR FROM HOT MOTORS. CHECKED THE ELEVATOR & WIRES ARE NORMAL.SDR SIMA20150210001Hot Water Pot · defectiveBURNING SMELL IN GALLEY ORIGINATING FROM HOT JUG LOCATION. FOUND LOOSE PIN ON BACK OF HOT JUG. REMOVED & DEFERRED IAW MEL 25-50 M PROCEDURE COMPLIED WITH.SDR P5CA2015020900007Oven · failedOVEN CONTROL PANEL HOT WITH C/B PULLED. ODOR OF BURNED PLASTIC. PERFORMED OVEN OPS CHECK AND CHECKED OK. NO PLASTIC ODOR IAW AMM 25-32-00. ACCOMPLISHED CONDITIONAL INSPECTION IAW AMM 05-51-56. NO OTHER ITEMS FOUND.SDR DALA2015020901034Unknown · odorCREW REPORTS BURNING SMELL FROM MID GALLEY. RESET CIRCUIT BREAKERS AND CLEAN HOT PLATE RUN CYCLES, OPS CHECK NORMAL.SDR CALA2015021093077Oven · malfunctionedGALLEY OVEN CB POPPED AFTER ELEC ODOR WAS DETECTED. CB OVEN COLLARED & OVEN DEFERRED, ODOR NO LONGER PRESENT. COMPLETE FORM 46-6020 FOR SMOKE & ODOR IN THE PLANE QUESTIONNAIRE.SDR CALA2015020693065Oven · dirtyOVEN NR 507 SMOKES WHEN HOT. OVEN FOUND TO BE DIRTY IN SIDE WITH CARAMEL. OVEN DEACTIVATED.SDR CALA2015020693069Oven · dirtyAFT OVEN IN THE MID GALLEY HAD AN ODOR. CREW SUGGESTED THAT THERE WAS SPILLED CARAMEL OR OTHER FOOD THAT WAS THE CAUSE. R & R OVEN. SMOKE WAS CONTAINED TO THE OVEN ONLY IAW CREW BRIEF.SDR V0XD20150201032Fitting · corrodedNUMBER 1 GALLEY 2 FLOOR FITTING BRACKET INSIDE FWD & AFT ARE CORRODED. REPLACED 2 NR 1 GALLEY FLOOR FITTING IAW CMM 52-33-42.SDR USAA2015020200026Oven · malfunctionedEN-ROUTE, EXTREME HEAT & ELEC SMELL COMING FROM AFT GALLEY RT FWD OVEN. PULLED ALL AFT GALLEY RT & COFFEE MAKER CB'S. HEAT SUBSIDED & SMELL DISSIPATED. REPLACED FWD RT OVEN ASSEMBLY AFT GALLEY. OPERATIONS CHECKED GOOD.SDR CALA2015012800071Oven · malfunctionedAIR RETURN, AFTER FLIGHT ATTENDANT REPORTED FIRST CLASS GALLEY OVENS 105 & 108 WENT INTO RED FAIL LIGHT MODE. ELEC SMELL & WHITE SMOKE EMITTING ABOVE OVEN AREA & AROUND OVENS 105 & 108. TURNED OVENS & CHILLERS OFF & PULLED CB`S & SMOKE STOPPED. RESIDUAL SMSDR UIEA2015012600025Hinge · bentAFT GALLEY LT WASTE BIN DOOR HAS BENT HINGE & FWD EDGE REQUIRES TRIM TO FIT. REMOVED WASTE BIN DOOR CLEANED DEBRIS FROM HINGE & REINSTALLED WASTE BIN DOOR IAW AMM 25-00-00-117-045.SDR UIEA2015012600023Rivet · looseAFT GALLEY RT WASTE BIN DOOR HINGE IS LOOSE. R & R RIVETS IN DOOR HINGE OF AFT GALLEY RT WASTE BIN DOOR IAW AMM 51-40-02.SDR CALA2015012300057Oven · fireOVEN FIRE IN FWD GALLEY OVEN 204, FLIGHT ATTENDANT PULLED CB & FIRE WENT OUT, VERY LITTLE SMOKE. CREW MEAL BURNED. REPLACED OVEN, NEW OVEN OPERATIONS NORMAL. ROTABLE PARTS CHANGE WAS INDICATED, TT 1711707, SN OFF 00794 OVEN, SMALL SG OFF 99-2532-9-0003 0794SDR USAA2015012000011Coffeemaker · shortedFLIGHT ATTENDANT HEARD POP NEAR NR 3 COFFEEMAKER IN AFT GALLEY, FOLLOWED BY A SHORT PERIOD OF ELEC SMOKE. REPLACED NR 3 AFT COFFEEMAKER IAW AMM 25-31-00. SYS OPERATIONS CHECKED GOOD.SDR CA150115003Microwave Oven · malfunctioned(CAN) WHILE IN CRUISE FLIGHT AT 40,000, ONE OF THE PASSENGERS WAS USING THE GALLEY MICROWAVE OVEN. WHILE IN USE, THE MICROWAVE P/N 400-2577-01 STARTED SPARKING AND SMOKING. THE CB TRIPPED STOPPING THIS NOTED ACTION. CB WAS LEFT OUT DURING THE REMAINDER OF THE SDR V0XD20150112014Mount Fitting · corrodedGALLEY NR 1 FLOOR MOUNTING FITTINGS 3 EACH CORRODED. REPLACED NR 1 GALLEY MOUNTING BRACKETS IAW CMM 25-33-47.
Back to JASC 2530