Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2015010992919Controller · defectivePIGTAIL 41 GIVES BURNING SMELL. COOKING LEVEL DOESN’T LIGHT UP. CHANGED CART CONTROLLER IAW MM 25-32-98. CHANGED PIGTAIL IAW MM 25-32-88. OPERATIONS CHECKED GOOD IAW MM 25-32-98-202-008.SDR DALA2015010500122Coffeemaker · sparksAFTER TAKEOFF THE F/A SAW A FLICKER OF LIGHT IN FIRST CLASS GALLEY COFFEEMAKER AREA, FOLLOWED BY FAINT ELECTRICAL ODOR AND SLIGHT HAZE. THE COFFEEMAKER CIRCUIT BREAKER WAS PULLED AND THE SMOKE ODOR DISSIPATED. MAINTENANCE COMPLIED WITH THE "SMOKE IN CABIN" SDR CALA2014123092869Oven · dirtySMOKE ODOR IN MID GALLEY AREA COMING FROM R31 OVEN. OVEN WAS SHUTDOWN & CB PULLED. CREW STATES THEY SAW SMOKE COMING FROM OVEN. WITH OVEN OFF & CB PULLED, ODOR & SMOKE DISSIPATING NO FURTHER ISSUES NOTICED. POS R31 FOUND OVEN TO HAVE MELTED FOOD ON BOTTOM. SDR AALA20141222005Oven · odorDURING CRUISE AN ELECTRICAL ODOR WAS REPORTED IN THE CABIN. THE IFE SYS WAS TURNED OFF & ODOR DISSIPATED. DIVERTED, EMERGENCY DECLARED, LANDING UNEVENTFUL. ACCOMPLISHED ALL CHECKS IAW AMM 21-00-00-810-808 WITH NO FAULTS FOUND. PERFORMED CHECK OF IFE SYS IASDR QXEA2014122001104Hinge · damagedAFT F/A EMERGENCY EQUIPMENT DOOR IS NOT SELF CLOSING. REPLACED THE EQUIPMENT DOOR SPRING HINGES AS REQUIRED. OPS CHECK OF DOOR IS GOOD. RETURNED TO SERVICE.SDR V0XD201412200269Mount Bracket · corrodedNUMBER 1 GALLEY HAS TWO CORRODED MOUNTING BRACKETS. REPLACED NR 1 GALLEY BRACKETS IAW CMM 25-33-42.SDR CNMA2014120001Oven · fireAFTER LEVEL OFF, F/A REPORTED FIRE IN AFT NR 3 GALLEY OVEN. PERFORMED INSPECTION OF AFT GALLEY OVEN. FOUND FOOD TRAYS AND FOOD BURNED. COMPLIED WITH OPS CHECKS OF OVEN NR 3 AND NR 1, 2, 4 AND NR 5 OVENS IAW CMM 25-36-22, NO FAULTS NOTED AT THIS TIME. OK FSDR USAA2014121500003Oven · faultyMID CABIN GALLEY OVEN NR 2 OVERHEAT RED LIGHT ON. BURNT PLASTIC OVEN SMELL, ODOR. REPLACED MID GALLEY NR 2 OVEN. OPERATIONAL CHECK IS OKAY.SDR CA141211001Coffeemaker · overheated(CAN) IN CRUISE FLIGHT THE FA REPORTED A SMOKE SMELL FROM THE GALLEY AREA. THE GALLEY CB WERE PULLED & THE SMELL DISSIPATED. THE AIRCRAFT CONTINUED TO DESTINATION. IT WAS DETERMINED THAT THE RIGHT COFFEE BREWER WAS OVERHEATING, THE RIGHT COFFEE BREWER WAS RESDR CA141211004Oven · smoke(CAN) ABOUT 45 MINUTES AFTER TAKEOFF, SMOKE COMING OUT OF THE AFT GALLEY OVEN #2 WAS REPORTED BY THE CABIN CREW TO FLIGHT CREW WHO HAD COMPLETED THE Ï¿½SMOKE, FIRE OR FUMESÏ¿½ CHECKLIST , QRH 8.8. IN ABOUT FIVE MINUTES AFTER QRH 8.8 HAS BEEN APPLIED, THE SMOKESDR USAA2014120800011Oven · odorEN-ROUTE, ON TAKEOFF 5 FLIGHT ATTENDANTS SMELLED A RUBBERY ODOR IN REAR OF ACFT. ODOR DISAPPEARED AFTER TAKEOFF, BUT SEVERAL FLIGHT ATTENDANTS HAD VARIOUS REACTIONS TO IT. THE FLIGHT DIVERTED EN ROUTE & LANDED WITHOUT FURTHER INCIDENT. INSPECTED THE ACFT & SDR USAA2014120200005Oven · overtempAFT OVEN NR 2 OVER TEMP LIGHT ON. SMELLS HOT IN GALLEY. CB PULLED OTHER AFT OVEN EMITS HIGH PITCHED SOUND WHEN TURNED ON. REMOVED & INSTALLED NEW GALLEY OVEN IN AFT GALLEY NR 2 POSITION.SDR DALA2014113006357Oven · contaminatedDIVERTED DUE TO AN INFLIGHT OVEN FIRE IN THE AFT GALLEY. CREW COMPLIED WITH QRH PROCEDURES. MAINTENANCE FOUND BURNED RESIDUE ON THE OVEN HEATING COIL. REPLACED AFT GALLEY LT OVEN IAW AMM.SDR YENA20141126263Coffeemaker · failedF/A REPORTED BURNING PLASTIC ODOR IN FWD GALLEY WHEN COFFEE POTS TURNED ON. ALSO PANEL ABOVE COFFEE POTS FELT EXTREMELY HOT. TURNED COFFEE POTS OFF & ODOR WENT AWAY. ACCOMPLISHED INSP OF ACFT IAW TSM 05-50-00-810-831, FOUND FWD COFFEE MAKER 105 INOPERATIVE. SDR SWAA2014111734242Coffeemaker · faultyAIR TURN BACK, FUMES REPORTED BY AFT FLIGHT ATTENDANT, SMELLED LIKE BURNING PLASTIC COMING THRU GASPER VENTS. R & R AFT NR 2 COFFEE MAKER IAW MM.SDR CA141117004Oven · smoke(CAN) FWD GALLEY OVEN PRODUCING SMOKE FROM TOP AND SIDE. C/B PULLED AND CABIN UTILITY SELECTED OFF. FWD GALLEY OVEN REMOVED AND FOUND OVEN BEING THE CAUSE OF SMOKE. FWD GALLEY OVEN DEACTIVATED C/PULLED AND COLLARDED. WIRING INSPECTED WITH NO FAULT. FWD GALSDR USAA2014111700001Oven · dirtyFLIGHT ATTENDANT IN REAR GALLEY REPORTED STRONG ODOR, MUSTY SMELL. AT CRUISE, SELECTED HI FLOW PACK & ODOR DISSIPATED. NO SMELL IN REST OF CABIN. REPLACED OVENS 6 - 11 & 7 - 12.SDR CALA2014111401444Oven · malfunctionedON TAXI OUT AFTER ENG START FWD GALLEY OVEN ACFT LT OVERHEATED CAUSED SMOKE. CB PULLED RETURNED TO GATE. PLACED FWD GALLEY OVEN NR 1 ON PLACARD. COMPLIED WITH SMOKE & ODOR QUESTIONNAIRE FORM 46.6020. COMPLIED WITH INSPECTION TASK 05-51-58-910-801C1. R & RSDR USAA2014111300004Oven · faultyLEFT OVEN SMOKES WHEN TURNED ON SMOKE QUITS WHEN OVEN IS TURNED OFF. REPLACED FWD LT OVEN IAW AMM 25-35-19.SDR USAA2014111000007Oven · smokeWHILE ENROUTE NR 1 OVEN FWD GALLEY ACFT LT BEGAN TO PRODUCE SMOKE DURING MEAL PREP OVEN WAS TURNED OFF & SMOKE STOPPED. NO INDICATION OR FLAME OBSERVED. SMOKE EVACUATED AS LIGHT. NO EXTINGUISHER USED. REPLACED NR 1 LT OVEN IAW AMM 25-35-19. OPERATIONS CHESDR UIEA2014103100521Door · unsecureAFT GALLEY RT SIDE WASTE FLAPPER DOOR DETACHES ON LOWER EDGE. ADJUSTED HINGE & SECURED AFT GALLEY RT SIDE WASTE FLAPPER DOOR IAW AMM 20-11-00.SDR UIEA2014103100530Seal · tornFORWARD GALLEY WASTE CONTAINER DOOR LOWER SEAL TORN. REPLACED FWD GALLEY WASTE CONTAINER DOOR LOWER SEAL IAW AMM INTRODUCTION STEP 2.SDR CALA2014102992625Chiller · malfunctionedREPORT OF EXHAUST SMELL NEAR FWD AFT LAVATORY, AFT GALLEY AREA. FOUND AFT GALLEY FWD CHILLER BLUE POWER LIGHT FLASHING, WITH LITTLE OR NO AIRFLOW FROM CHILLER. UNIT SHUTS OFF & RESTARTS. REPLACED AFT GALLEY FWD CHILLER, CLEANED FILTER. NO SMELL AFTER REPLASDR C77A20141027002Coffeemaker · shortedSTRONG ELEC ODOR FROM FWD GALLEY, FWD COFFEEMAKER APPEARS INOPERATIVE. NO SMOKE SEEN, JUST SMELLED. OCCURRED 4 MINS BEFORE LANDING & SMELL DISSIPATED UPON LANDING. NO CB POPPED. COFFEEMAKER WAS REPLACED.SDR USAA2014102100006Oven · odorFORWARD GALLEY OVEN 1 - 7 HAS RUBBER ODOR WHEN OPERATING. R & R OVEN.SDR USAA2014101600005Chiller · odorFLIGHT ATTENDANT NOTICED AN ELECTRICAL ODOR IN AFT GALLEY. ODOR STOPPED AFTER TURNING CHILLER OFF. R & R AFT GALLEY CHILLER IAW AMM 25-34-51.SDR ASOA20141014113Coffeemaker · shortedF/A REPORTED, SPARKS SHOT OUT BETWEEN THE COFFEE POTS, IN FLIGHT. THE F/A TURNED OFF THE COFFEE POTS AND THE SPARKS STOPPED. R & R THE NR 2 COFFEE BREWER WITH OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR CALA2014100801321Oven · malfunctionedAPPROXIMATELY 7 HOURS INTO FLIGHT A BURNING RUBBER SMELL EMANATED FROM THE MID GALLEY OR MID LAVATORY AREA THAT GREW WORSE. ACCOMPLISHED SMOKE FUME CHECKLIST. REMOVED LT & RT UTILITY BUS, LT & RT RECIRCULATION FAN. AFTER LANDING EQUIPMENT COOLING LIGHT CAME SDR SWAA2014100832762Coffeemaker · faultyDIVERSION ELEC SMELL AFT GALLEY COFFEE MAKER AREA. AFT GALLEY NR 2 COFFEE MAKER CAUSING SMELL. R & R NR 2 COFFEE MAKER IAW AMM.SDR CA141007006Relay · burned(CAN) 1 COFFEMAKER IN THE FWD GALLEY HAD ELECTRICAL FLASHES AND ARCING EMANATING FOR THE RELAY AT THE BACK OF THE UNIT. A CLOUD OF BLACK SMOKE AND A BIG BLUE/YELLOW FLASH WAS SEEN BY THE CABIN CREW. THEY DISCHARGED A FIRE EXTINGUISHER ON BOTH COFFEMAKERS ANDSDR USAA2014093000001Oven · malfunctionedOVEN NR 1 LT STARTED TO SMOKE WITH MEDIUM HEAT. R & R FWD NR 1 OVEN IAW AMM 99-2535-4-0001.SDR USAA2014092600008Coffeemaker · unserviceableFWD & AFT ODOR OF A BURNING SMELL EN ROUTE & DURING DESCENT. R & R AFT COFFEEMAKERS & FOUND FOOD DEBRIS IN FWD GALLEY OVEN. REMOVED SHELVES & CLEANED INSIDE OVEN. NO ODOR PRESENT DURING TESTING.SDR DALA2014092105214Oven · failedDURING FLIGHT, FORWARD GALLEY OVEN HAD SMOKE COMING FROM BOTH VENTS WITH DISTINCT ODOR OF ELECTRIC FIRE. OVEN WAS ON BUT NOT HEATING AT THE TIME THEN SHUT ITSELF OFF. REMOVED AND REPLACED THE OVEN .SDR USAA2014092200001Chiller · unserviceableFLIGHT ATTENDANT SWITCHED AFT GALLEY CHILLER OFF DUE TO A MOMENTARY MILD SMELL OF BURNING RUBBER. SMELL DISAPPEARED UPON SWITCHING COOLER OFF. R & R AFT GALLEY CHILLER IAW AMM 25-34-51-000-002-A. CHECKED OK.SDR DALA2014092205142Oven · shortedDURING FLIGHT, THE FORWARD GALLEY OVEN EXPERIENCED ELECTRICAL SHORT WITH SPARKS AND SMOKE. PULLED THE CIRCUIT BREAKER, SMOKE AND ODOR WENT AWAY. MAINTENANCE REMOVED OVEN, INSPECTED AREA, NO SMOKE NOTED. REPLACED OVEN IAW AMM 25-31-88. RAN OVEN FOR 20 MINS,SDR CALA2014091892230Chiller · inoperativeAFT GALLEY SMOKE ODOR, CHILLER INOPERATIVE. R & R AFT RT GALLEY CHILLER IAW AMM 25-33-02. 28VDC PIN 6 NO 115VAC PINS 1, 2 & 3 AT CHILLER WDM 25-33-11, NO 115VAC AT RT AFT GALLEY POWER PANEL. SUSPECT RT AFT GALLEY ELCU TRIPPED. CYCLED RT UTILITY BUS SWITCH.SDR CA140917014Oven · failed(CAN) A POPPING NOISE HAS BEEN HEARD AND SPARKS WERE SEEN COMING OUT FROM THE BACK OF THE MID GALLEY OVENS. TWO OVENS WERE SUSPECTED (1 ON POS 5502 AND THE OTHER ONE ON POS 5503). ALL 5 BREAKERS OF MID GALLEY OVENS WERE PULLED OFF FOR THE REMAINDER OF THE FLIGSDR CALA2014090892074Oven · odorELEC SMELL COMING FROM MID GALLEY AREA, ODOR PRESENT AGAIN ON GATE APPROX 6 HOURS AFTER ARRIVAL. RECIRC FANS OFF, GND AIR BLOWING INTO ACFT. SMELL NOTICEABLE FROM AROUND PILOT REST SEAT AFT THROUGH ECONOMY PLUS. COFFEE MAKERS, WARMERS & EVERYTHING IN GALLEYSDR CA140903013Coffeemaker · odor(CAN) CREW REPORTED FWD COFFEE MAKER BURNING ODOR IN FLIGHT. CIRCUIT BREAKER WAS PULLED AND ODOR DISSIPATED.SDR DALA2014090404914Circuit Board · overheatedELECTRICAL FUMES DETECTED INFLIGHT FROM COFFEEMAKER CIRCUIT BREAKER PANEL NEAR R2 DOOR. FOUND OVERHEAT DAMAGE ON COFFEEMAKER PC BOARD. REMOVED AND REPLACED THE COFFEEMAKER IAW AMM 25-31-12. NO FURTHER FUMES DETECTED. VERIFIED CORRECT VOLTAGE AT CONNECTOR.SDR USAA2014082500007Oven · overheatedEN-ROUTE AFT GALLEY OVEN NR 1 OVERHEAT WARNING LIGHT ILLUMINATED. PULLED OVEN CB 6-11. R & R AFT NR 1 OVEN.SDR CA140822009Coffeemaker · odor(CAN) AFTER DEPARTURE, AN ACRID ODOR HAD RETURNED ON THE ACFT. THE CREW ELECTED TO RETURN WHERE A PAN WAS DECLARED AND AN OVERWEIGHT LANDING WILL BE CARRIED OUT. ERS WILL BE RESPONDING. MAINTENANCE CONTROL, DUTY PILOT AND CORP SAFETY ADVISED. RESOLUTION ARSDR CA140822004Oven · smoke(CAN) ON APPROACH, SMOKE WAS REPORTED IN THE AFT GALLEY. LOCAL MAINTENANCE WAS ADVISED ON ARRIVAL. FOUND OVEN CIRCUIT CREATING THE ODOR. REPLACED OVEN AND CONTROLLER IAW S.P.SDR CA140821006Coffeemaker · odor(CAN) PAN PAN DECLARED WITH ATC FOR PRIORITY HANDLING ON ARRIVAL IAW BURING ODOR FROM MID GALLEY. ESTIMATED LANDING WEIGHT, 144,500 KGS. FOUND COFFEEMAKER IN MID GALLEY AT POSITION 6416 CIRCUIT BREAKER POPPED. MAINTENANCE STAFF REMOVED THE COFFEEMAKER AND SDR CA140820001Drain Valve · damaged(CAN) INCIDENT DETAILS: DIVERTING DUE TO AFT GALLEY FLOODED. ENTIRE WATER SYSTEM SHUT-OFF IN ATTEMPTS TO STOP FLOODING. RESOLUTION FOUND COFFEE,CONGEALED MILK AND TISSUE CAUSING BLOCKAGE AT T PIECE IN AFT CARGO FLOOR JUST ABOVE AFT DRAIN MAST. BLOCKAGE REMOVSDR DALA2014081404610Oven · fireNR 2 OVEN IN AFT GALLEY HAD A FIRE NEAR FAN, WAS NOT FOOD, FIRE WENT OUT WITH MINIMAL SMOKE. FIRE CONTAINED IN OVEN WITH NO EXTERNAL DAMAGE CIRCUIT BREAKER COLLARED. REPLACED OVEN.SDR CA140811008Coffeemaker · odor(CAN) ON CLIMB A BURNING SMELL WAS DETECTED IN FLIGHT DECK. F/A`S WE`RE CONTACTED AND SMELL WAS REPORTED IN BOTH GALLEYS. SMELL DISSIPATED DURING CONVERSATION (15-20 SEC). CIRCUIT BREAKERS FOR COFFEE MAKERS, LAVÏ¿½S AND TABLET CASE INSPECTED AND ALL APPEARED FSDR DALA2014081104424Oven · odorF/A REPORTED THAT THE FORWARD GALLEY OVEN SMOKED DURING OPERATION AND DESCRIBED IT AS AN ELECTRICAL ODOR. CABIN CREW ADVISED THE COCKPIT THAT THE OVEN WAS TURNED OFF AND THE CIRCUIT BREAKER WAS PULLED. GALLEY POWER WAS TURNED OFF. INSPECTION OF GALLEY OVEN SDR DALA2014081104605Oven · smokePERFORMED AN AIR TURN BACK DUE TO SMOKE COMING FROM THE FORWARD GALLEY OVENS. CREW FOLLOWED THE QRH AND PULLED CIRCUIT BREAKERS. SMOKE DISSIPATED BUT EXCESSIVE HEAT REMAINED IN THE AREA. MAINTENANCE FOUND THAT ALL THREE FORWARD GALLEY OVENS HAD EVIDENCE OF SDR CALA2014081191931Chiller · overheatedAFT GALLEY CHILLER OVERHEATED IAW CREW VERBAL. CB'S PULLED THE CB PANEL AT GALLEY & COFFEE MAKERS WERE HOT & DID NOT COOL DOWN. EVENTUALLY CREW DESELECTED THE COMMERCIAL SWITCH & STILL DID NOT COOL. DEFERRED IAW MEL. DEACTIVATED CHILLER, PULLED & COLLARED
Back to JASC 2530