SDR CALA2014081191931Chiller · overheatedAFT GALLEY CHILLER OVERHEATED IAW CREW VERBAL. CB'S PULLED THE CB PANEL AT GALLEY & COFFEE MAKERS WERE HOT & DID NOT COOL DOWN. EVENTUALLY CREW DESELECTED THE COMMERCIAL SWITCH & STILL DID NOT COOL. DEFERRED IAW MEL. DEACTIVATED CHILLER, PULLED & COLLARED Aug 8, 2014 · N854UA · Airbus A319131SDR CALA2014081191933Oven · overheatedTHE CAPTAIN REPORTED AFT GALLEY OVEN R53 EXHIBITED SIGNS OF OVERHEATING & POSSIBLE FLAMES ISSUING FROM THE OVEN. OVEN WAS SHUTDOWN. ACFT DIVERTED FOR THIS. INSPECTION ACCOMPLISHED IAW MM 05-5 1-50. NO DAMAGE TO SURROUNDING AREA OR WIRING. CEILING PANELS RAug 6, 2014 · N780UA · Boeing 777222SDR R61A201408051009Spacer · corrodedDURING HEAVY CHECK, FOUND FWD GALLEY OG AFT FLOOR SPACER IS CORRODED. MX R & R CORRODED FLOOR SPACER IAW AMM 25-31-01, PN 170-87799-001.Aug 5, 2014 · N829MD · Emb ERJ170100SUSDR USAA2014080400017Chiller · malfunctionedA STRONG ELEC SMELL IN AFT GALLEY. CREW DECLARED AN EMER & DIVERTED. FLIGHT LANDED WITHOUT INCIDENT. REPORTED STRONG SMELL WAS COMING FROM AFT GALLEY CHILLER. R & R AFT GALLEY CHILLER. PERFORMED SYS OPERATIONS CHECK. CHECKED GOOD AT THIS TIME IAW AMM 25-Aug 4, 2014 · N179UW · Airbus A321211SDR AWKA2014080600814Microwave Oven · failedWHILE IN CRUISE FLIGHT, THE FLIGHT CREW NOTED AN ELEC SMELL AS THE MICROWAVE OVEN WAS IN OPERATION. NO PHYSICAL INDICATIONS OF FIRE OR SMOKE WAS NOTED. AS A PRECAUTION, THE FLIGHT CREW ELECTED TO DIVERT. THE MICROWAVE WAS SUBSEQUENTLY REMOVED FROM THE ACFT Aug 2, 2014 · N790XJ · Cessna 750SDR USAA2014080400009Oven · defectiveEN-ROUTE AFT GALLEY OVEN 412 SMOKE IN OVEN. HALOGEN EXTINGUISHER USED. REPLACED THE AFT BULKHEAD PORTABLE FIRE EXTINGUISHER & DEFERRED THE OVEN REPLACEMENT USING MEL PROCEDURES. REPLACED AFT GALLEY OVEN 412.Aug 1, 2014 · N200UU · Boeing 7572B7SDR A6WA201441824Coffeemaker · malfunctionedCLIMB THREW 14,000 FT, FLIGHT ATTENDANT REPORTED SMOKE IN GALLEY THAT APPEARED TO BE COMING FROM THE COFFEE MAKER. LANDING WEIGHT 48,200 LBS. PERFORMED INSPECTION WIRE HARNESS BEHIND COFFEE MAKER, NO DEFECTS NOTED. PERFORMED INSPECTION OF GALLEY LIGHTS, HEAJul 30, 2014 · N409AW · Cndair CL6002B19SDR CALA2014072891545Oven · malfunctionedCREW REPORTS ELEC BURNING ODOR IN AFT GALLEY. SET MAIN POWER SWITCH ON GALLEY POWER PANEL TO OFF, OPENED CB'S FOR OVENS & CREW REPORTS HOT AIR STILL BLOWING FROM OVENS. REPLACED SUSPECTED OVEN R51. VERIFIED THE CONNECTOR BEHIND THE OVEN, NO IRREGULARITY FOUJul 28, 2014 · N782UA · Boeing 777222SDR CALA2014072800999Oven · faultyAFT OVEN 424 SMELLS LIKE BURNT WIRES. CONFIRMED FAULTY AFT OVEN 424. R & R IAW AMM 25-34-00-400-801C3. OPERATIONS CHECKED GOOD. PERFORMED TASK 05-26-800-801C1 STEP 3. OKAY FOR SERVICE. ROTABLE PARTS CHANGE WAS INDICATED TT 1621129, SN OFF 07200 IPC REFERJul 24, 2014 · N27734 · Boeing 737724SDR ASOA20140721080Coffeemaker · odorNR 1 COFFEEMAKER PRODUCING A BURNING ODOR. MX R & R NR 1 COFFEEMAKER AND OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.Jul 21, 2014 · N12201 · Emb EMB145XRSDR USAA2014072200004Coffeemaker · faultyAFT GALLEY COFFEE MAKERS REPORTED TO HAVE ELEC SMOKE SMELL WHEN TURNED ON, REMAINED OFF DURING FLIGHT. COULD NOT DISTINGUISH WHICH POSITION ON BOTH. REPLACED ALL COFFEE MAKERS IN AFT GALLEY. OPERATIONS CHECKED NORMAL.Jul 21, 2014 · N908AW · Boeing 7572G7SDR CALA2014072291495Oven · smokeOVEN SMOKING OR SPARKING R31 & R32. DEPOWERED GALLEY & SMOKE STOPPED. SLIGHT ELEC SMELL OVEN R31 INOPERATIVE & COLLARED.Jul 19, 2014 · N227UA · Boeing 777222SDR ASOA20140710053Coffeemaker · unknownTHE CREW REPORTED LT COFFEEMAKER CAUGHT FIRE. MAINTENANCE INSPECTED COFFEEMAKER AND SURROUNDING AREAS. NO EVIDENCE OF FIRE WAS NOTED.Jul 10, 2014 · N13997 · Emb EMB145LRSDR DALA2014070704036Oven · smokeFLIGHT ATTENDANTS REPORTED FIRST CLASS GALLEY OVEN SMELLED OF SMOKE. PULLED CIRCUIT BREAKER. NO EVIDENCE OF ODOR OR VISIBLE SMOKE FROM FLIGHT DECK OR CABIN.Jul 6, 2014 · N6706Q · Boeing 757232SDR UHLA2014070500493Valve · out of alignmentR2 DOOR SEAL MADE A SQUEALING SOUND FOR THE ENTIRE FLIGHT. PERFORMED ACFT PRESSURIZATION TEST. FOUND AFT GALLEY SELF DRAIN VALVE NEEDED TO BE RESEATED, IT WAS CAUSING THE SQUEALING IAW AMM 21-30-00. OPS CHECK GOOD.Jul 5, 2014 · N201JQ · Emb ERJ170200LRSDR USAA2014063000002Coffeemaker · faultyTHE AFT COFFEE MAKER NR 2 HAS A BURNT ELEC WIRE SMELL WHEN IN USE. PULLED CB FOR SAFETY. REPLACED COFFEE MAKER NR 2 IN AFT GALLEY IAW AMM 25-35-15. OPERATIONS CHECKED GOOD.Jun 28, 2014 · N802AW · Airbus A319132SDR UIEA2014062700256Door · dirtyAFT GALLEY RT WASTE LID WILL NOT CLOSE. CLEANED AFT GALLEY RT WASTE LID SO IT CLOSES PROPERLY AMM 25-00-00.Jun 27, 2014 · N641GT · Boeing 76738ESDR CALA2014062700816Chiller · failedAFT GALLEY CHILLER 7 DURING BOARDING MADE POP THEN DEPRESSOR HISS WITH SMALL AMOUNT WHITE GAS MADE OUT INTO GALLEY. PLACED AFT GALLEY CHILLER 7, GALLEY 7, ON PLACARD. NDS REPLACEMENT. COMPLIED WITH DDP.Jun 26, 2014 · N27015 · Boeing 777224SDR CALA2014062091324Seal · missingOVEN 41 RUBBER SEAL MISSING, BUS GALLEY. REQUIRES DOOR SEAL OR OVEN REPLACEMENT AT POS R41. REPLACED OVEN, OPERATIONS CHECKED OK.Jun 19, 2014 · N649UA · Boeing 767322SDR USAA2014061900014Oven · defectiveAFT OVEN DEFECTIVE, FLIGHT ATTENDANT REPORTED ELEC SMELL. FLIGHT ATTENDANT PULLED CB ON NR 2 AFT OVEN, SMELL DISSIPATED. R & R NR 2 OVEN.Jun 18, 2014 · N201UU · Boeing 7572B7SDR DALA14036426803Oven · contaminatedF/A HAD A BURNING ODOR AND SMOKE FROM REAR GALLEY WHILE HEATING MEALS. F/A PULLED CIRCUIT BREAKER AND SMOKE CLEARED. FOUND BURNED PAPER IN NR 5 OVEN. REMOVED PAPER, CLEANED OVEN, OPS CK NORMAL. AS PRECAUTIONARY, DEFERED TO NEF 25-34-02. NR 5 OVEN REPLACED OJun 15, 2014 · N704X · Boeing 7572Q8SDR AALA20140613008Coffeemaker · malfunctionedCREW REPORTED ELEC ODOR IN CABIN. CREW DONNED O2 MASKS FOR LANDING. EMER DECLARED FLIGHT LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. REPLACED FWD GALLEY NR 2 COFFEE MAKER THAT WAS CAUSING ODOR. SYS GND CHECKED NORMAL OPERATION CLOSED.Jun 13, 2014 · N494AA · Doug DC982SDR USAA2014061300001Oven · dirtyNUMBER 3 OVEN, REAR GALLEY, CREATES STRONG ODOR OF MELTING PLASTIC WHEN OPERATING. CLEANED OVEN.Jun 10, 2014 · N282AY · Airbus A330243SDR USAA2014061200008Coffeemaker · leakingEXPERIENCED ODOR ON TAKEOFF FROM TLV. ODOR LASTED FOR A FEW MINUTES & WAS GONE BEFORE PASSING 10K. FLIGHT ATTENDANT NOTED SMELL THROUGHOUT CABIN. MAINTENANCE FOUND COFFEEMAKER IN AFT LT GALLEY DEFECTIVE LEAKING COFFEE ON THE MOUNTING RACK OF COFFEEMAKER. RJun 9, 2014 · N289AY · Airbus A330243SDR SWAA2014061028887Coffeemaker · faultyAIR TURN BACK, AT APPROX 1000 FT AFTER TAKEOFF, FLIGHT ATTENDANTS NOTIFIED COCKPIT OF STRONG ACRID ODOR IN FRONT OF CABIN. R & R FWD COFFEE MAKER IAW MM.Jun 7, 2014 · N662SW · Boeing 7373Q8SDR SWAA2014060928808Coffeemaker · defectiveELECTRICAL SMELL BETWEEN ROWS 1 TO ROW 3. FOUND FWD COFFEE MAKER CB POPPED. R & R COFFEE MAKER IAW MM.Jun 4, 2014 · N288WN · Boeing 7377H4SDR USAA2014060600001Oven · contaminatedON DEPARTURE FROM TLV A FUME REPORT WAS GIVEN TO THE FLIGHT CREW. FUMES WERE REPORTED IN THE REAR OF ACFT CAUSING BURNING EYES & THROATS. DIVERTED TO ATHENS. REPLACED GALLEY 6 POSITION 1 & 2, & GALLEY 7 POSITION 1 OVENS.Jun 4, 2014 · N282AY · Airbus A330243SDR CALA2014060991246Oven · dirtyFIRST CLASS GALLEY 413 RT OVEN HAD SPILLED CARAMEL IN IT THAT CAUSED SMOKE TO FILL GALLEY, FIRE HAZARD. NEED THOROUGH CLEANING OR OVEN CHANGE. REPLACED RT OVEN IN FIRST CLASS GALLEY. OPERATIONS CHECKED OK.Jun 1, 2014 · N596UA · Boeing 757222SDR DALA14032330925Oven · smokeWHILE ENROUTE, THE F/A REPORTED SMOKE FROM FIRST CLASS GALLEY OVEN. OVEN WAS TURNED OFF AND THE CIRCUIT BREAKERS WERE PULLED. THE F/A DISCHARGED A HALON FIRE EXTINGUISHER INTO THE OVEN. SMOKE DISSIPATED AND FLIGHT CONTINUED. REPLACED OVEN.May 24, 2014 · N925DL · Doug MD88SDR 2014FA0000337Coffeemaker · overheatedAIRCRAFT RETURNED TO GATE DUE TO PILOT REPORT OF AFT GALLEY ELECTRICAL ODOR AND LIGHT SMOKE FROM COFFEEMAKERS. DURING INSPECTION AFT GALLEY WAS FOUND COFFEEMAKER N-1 IN OVERHEATING, NO DAMAGES WERE FOUND IN OTHER AREA, IAW AMM 25-35-15-000-001-A. THE COFFEEMMay 23, 2014 · N454AV · Airbus A320214SDR CA140523002Oven · overheated(CAN) WHILE EN-ROUTE, FIRE WITH BLACK SMOKE REPORTED BY F/A IN REAR GALLEY OVEN. 2 FIRE EXTINGUISHERS USED TO PUT OUT THE FIRE. F/A OBSERVED SPARKS ABOVE OVEN. ALL ELECTRICAL POWER TURNED OFF TO THE AFT GALLEY OVEN AND NO FURTHER SERVICE WAS CONDUCTED. NO May 22, 2014 · Boeing 777233LRSDR DALA14031780913Oven · contaminatedDUE TO A REPORT OF SMOKE IN THE CABIN THAT WAS IDENTIFIED AS BEING CAUSED BY AN OVEN IN THE GALLEY. CREW DECLARED AN EMERGENCY AND REPORTED THAT THE SMOKE DISSIPATED. MAINTENANCE PERFORMED CABIN SMOKE/ODOR WC 2120-2367. THE FWD GALLEY OVEN WAS FOUND WITH GREMay 22, 2014 · N913DL · Doug MD88SDR CALA2014051691022Oven · malfunctionedOVEN SMOKING OR SPARKING R31 NO EVIDENCE OF FIRE. FLIGHT ATTENDANT REPORTED SMOKE INSIDE OF OVEN. REPLACED OVEN & OPERATIONS CHECKED OK IAW MM2 5-32-02.May 14, 2014 · N206UA · Boeing 777222SDR USAA2014051500011Coffeemaker · faultyCREW REPORTED THE NR 1 FWD COFFEE MAKER CB POPPED. ELEC SMELL & NO SMOKE. CONFIRMED NR 1 FWD COFFEE MAKER CB POPPED. CHECKED CONTROL PANEL & RAN OVENS. REPLACED NR 1 COFFEE MAKER IAW AMM 25-35-15-0401-00. ALL OPERATIONS CHECKED OK.May 14, 2014 · N837AW · Airbus A319132SDR A6WA201441523Stiffener · crackedGALLEY FWD INBD LWR COMPARTMENT DOOR HINGE ATTACH STIFFENER CRACKED. REPAIR OF GALLEY FWD INBD LWR COMPARTMENT DOOR HINGE ATTACH STIFFENER SEE WORK CARD 54587-2000-0020 FOR REPLACEMENT OF DOOR ASSEMBLY.May 9, 2014 · N446AW · Cndair CL6002B19SDR CALA2014051200579Oven · defectiveFOR SDR REPORTING PURPOSES REF LOG PG 7641433 OVEN POS 108 OVERHEATED CAUSED SMOKE TO BILLOW OUT FWD GALLEY. NO FIRE, HALON EXT USED. ACCOMP AMM COND INSP 05-51-58-800-801C3. OVEN 108 FOUND DEFECTIVE, OVEN REMOVED, NO SURROUNDING DAMAGE NOTED, REINSTALLED OMay 9, 2014 · N78017 · Boeing 777224SDR CA140508005Oven · failed(CAN) OVEN IN AFT GALLEY WAS FOUND TO BE EMITTING AN ELECTRICAL SMELL. OVEN TURNED OFF, CIRCUIT BREAKER PULLED. ODOR DISSIPATED. FOOD WAS IN THE OVEN AT THE TIME. OVEN LINER REPLACED. BREAKER RESET. OVEN FUNCTIONED. NO ODOR.May 8, 2014 · Boeing 777233LRSDR JJBA20140505001Door · inoperativeGALLEY CABINET DOOR INOPERABLE. SECURED GALLEY DOOR.May 5, 2014 · N366PH · Dhav DHC8202SDR CALA2014050290944Coffeemaker · defectiveM61 - M62 GIVES OFF BURNT METALLIC SMELL WHEN COFFEEMAKERS ARE ON. R & R COFFEEMAKER AT M61 IAW AMM 25-32-01.May 2, 2014 · N792UA · Boeing 777222SDR DALA14027515531Coffeemaker · failedFLIGHT DIVERTED, AN ELECTRICAL ODOR REPORTED IN THE AFT CABIN. MAINTENANCE FOUND RT AFT COFFEEMAKER BAD, REPLACED, OPS CHECKED GOOD.Apr 30, 2014 · N531US · Boeing 757251SDR A6WA201441490Fitting · corrodedGALLEY INBD AFT FOOT CORRODED. R & R INBD AFT GALLEY FOOT WITH SERVICEABLE PART IAW SRM 51-40-11 & 51-41-02.Apr 25, 2014 · N403AW · Cndair CL6002B19SDR R61A201404200589Structure · corrodedDURING HEAVY CHECK, AFT GALLEY MATING SURFACES FOR FWD AND AFT PORTIONS OF GALLEY HAVE SEVERAL AREAS OF CORROSION. MX R & R ALL CORRODED PARTS ON MATTING SURFACES ON FWD AND AFT PORTIONS OF GALLEY IAW AMM 25-00-23,25-00-05.Apr 20, 2014 · N133HQ · Emb ERJ170200LRSDR USAA2014042100006Coffeemaker · faultyAFT FLIGHT ATTENDANT REPORTED AFT GALLEY BLUE HAZE WITH ELEC SMELL. TURNED OFF ALL AFT GALLEY COFFEE MAKERS & PULLED CIRCUIT BREAKERS, BLUE HAZE CLEARED. REPLACED ALL 4 AFT GALLEY COFFEE MAKERS. NO ODORS DETECTED.Apr 20, 2014 · N642AW · Airbus A320232SDR ASOA20140417046Coffeemaker · dirtyF/A REPORTED AN ODOR COMING FROM THE GALLEY COFFEEMAKERS. MAINTENANCE CLEANED THE WARMERS ON BOTH COFFEE BREWERS AND PERFORMED AN OPS CHECK, CHECKED GOOD, WITH NO BURNING ODORS DETECTED. ACFT WAS APPROVED FOR RETURN TO SERVICE.Apr 17, 2014 · N11565 · Emb EMB145LRSDR CALA2014041790856Coffeemaker · malfunctionedBURNING SMELL WHEN BREWING COFFEE AT M41. REPLACED COFFEE MAKER AT M41 IAW MM25-32-96-201. OPERATIONS CHECKED NORMAL, NO ODOR PRESENT.Apr 17, 2014 · N576UA · Boeing 757222SDR SIMA20140417001Control Panel · defectiveDURING DESCENT & APPROACH TO MIA, FLIGHT ATTENDANT REPORTS FAINT SMOKE SMELL IN GALLEY. AOM1 PROCEDURES COMPLIED WITH. INSPECTED GALLEY & FOUND ELEC CONTROL PANEL TO THE GALLEY, THE BOARD WITH BURN SMELL. R & R GALLEY ELEC CONTROL PANEL, OPERATIONS CHECKED Apr 17, 2014 · N935AE · Emb EMB145LRSDR ASOA201404140350Coffeemaker · failedCREW REPORTED COFFEE POTS WERE NOT WARMING AND A BURNING ODOR. ODOR DISSIPATED WHEN THEY WERE TURNED OFF. MAINTENANCE INSPECTED AND REPLACED THE COFFEE BREWER LT RAIL AND PUMP ASSEMBLY. OPS CHECKS WERE GOOD.Apr 14, 2014 · N12552 · Emb EMB145LRSDR CALA2014041090797Chiller · inoperativeFORWARD GALLEY CHILLER INOPERATIVE DUE TO SMOKE IN CABIN. ACCOMPLISHED AMM 05-51-56 FOUND SMOKE TO BE LOCALIZED TO FWD CHILLER 413, PULLED & COLLARED CB. REPLACED CHILLER IAW 25-3 3-98.Apr 7, 2014 · N524UA · Boeing 757222SDR USAA2014040700016Chiller · faultyFLIGHT ATTENDANT REPORTED AN ELEC OR PLASTIC SMELL NEAR ROWS 2 & 3 WHILE INFLIGHT. SMELL SEEMED TO DISSIPATE AFTER LANDING. ACCOMPLISHED JOB CARD 26L0002100 & FOUND FWD CHILLER WITH ELEC ODOR. REPLACED FWD GALLEY CHILLER IAW AMM 25-34-51-000-001-A & 25-34-5Apr 6, 2014 · N117UW · Airbus A320214SDR V0XD201404050073Mount Fitting · corrodedALL FIVE MOUNTING FITTINGS HAVE SIGNS OF CORROSION. R & R ALL FIVE MOUNT FITTINGS IAW CMM 25-33-42. PARTS INSTALLED, CDSP2019-7C-760, CDSP2019-7C-620, 9331091-3, & A661091-1.Apr 3, 2014 · N367CA · Cndair CL6002C10
Back to JASC 2530