Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20140403006Mount · corrodedG4B GALLEY RT SECTION COFFEE MAKER MOUNTING PLATE IS CORRODED. R & R COFFEE MAKER MOUNTING PLATE IAW AARD 25-30-00-8 PAGES 1 - 2.SDR CALA2014051391018Coffeemaker · sparksFORWARD COFFEE MAKER & ESPRESSO MACHINE SPARKED WITH VISIBLE SMOKE. REMOVED ESPRESSO MACHINE NR 209 & COFFEEMAKER NR 208. VISUALLY INSPECTED PLUGS & WIRING ON THE RACK, NO DAMAGED NOTED. ESPRESSO MACHINE NR 209 DEACTIVATED. CB`S PULLED & COLLARED. COFFEE SDR R61A201403310506Structure · corrodedDURING HEAVY CHECK, AFT GALLEY ON FRONT EDGE AROUND COFFEEMAKER IS CORRODED. MX R & R ALL CORRODED PIECES ON FRONT EDGE AROUND COFFEEMAKER IN AFT GALLEY IAW AMM 25-00-05, 25-00-23, 20-10-01, PN CDSP2200-11 SPLIT JOINT BRACKET.SDR CALA2014033190738Coffeemaker · failedFORWARD COFFEE MAKER & ESPRESSO MACHINE SPARKED WITH VISIBLE SMOKE. REMOVED ESPRESSO MACHINE NR 209 & COFFEE MAKER NR 208 & VISUALLY INSPECTED PLUGS & WIRING ON THE RACK, NO DAMAGED NOTED. ESPRESSO MACHINE NR 209 DEACTIVATED. CBS PULLED & COLLARED IAW IFM 2SDR ASAA2014032007271Oven · overheatedAFT GALLEY OVEN NR 2 OVERHEATED EVEN THOUGH IT HAD BEEN TURNED OFF FOR ABOUT 45 MINUTES. IT WAS GLOWING RED INSIDE IN THE SIDE PANELS. VERY LITTLE SMOKE WAS PRESENT WHEN THE OVEN DOOR WAS OPENED BUT THERE WAS INTENSE HEAT. THE FOOD IN THE OVEN TRAY WAS NOT SDR DALA14016860668Oven · odorF/A REPORTED FIRST CLASS GALLEY HAS ELECTRICAL BURN ODOR. R & R FWD GALLEY OVEN ASSY IAW AMM 25-31-05.SDR R61A201403140116Spigot · corrodedDURING HEAVY CHECK, FOUND FWD GALLEY WATER SPIGOT HAS CORROSION. MX R & R FWD GALLEY WATER SPIGOT IAW AMM 25-34-01.SDR CA140314013Coffeemaker · burned(CAN) F/A REPORTED SMOKE IN THE CABIN AND THAT THE FUMES WERE BAD ENOUGH TO BURN SOME PASSENGERS THROATS WHEN BREATHING. EMERGENCY WAS DECLARED AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND CHEWING GUM STUCK TO A COFFEE POT THAT WAS BURNING AND CREATING THESDR VNAA2014031200011Coffeemaker · odorCREW REPORTED STRONG CHEMICAL ODOR IN CABIN ON DESCENT. CREW DECLARED AN EMERGENCY AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTED, FOUND PAPER, DEBRIS BENEATH COFFEEMAKER AND REMOVED DEBRIS. MAINTENANCE R & R COFFEEMAKER AND PERFORMED CHECKS IAWSDR R61A201403120389Seal Seat · corrodedDURING HEAVY CHECK, FWD CARGO DOOR CUT OUT LOWER SEAL REST CENTER HAS CORROSION AROUND NUT PLATE. MAINTENANCE R & R FWD CARGO DOOR CUT OUT LOWER SEAL REST CENTER IAW SRM 51-41-01. MAJOR REPAIR.SDR USAA2014031300001Coffeemaker · faultyELEC FLASH FROM BEHIND THE CAPPUCCINO MAKER. STRONG ELEC SMELL WHICH DISSIPATED AFTER A FEW MINUTES, MID GALLEY 4. REPLACED COFFEEMAKER NR 1, NR 2 & NR 3 ESPRESSO MAKERS.SDR DALA14016540663Coffeemaker · odorELECTRICAL ODOR FROM COFFEEMAKER. REPLACED COFFEEMAKER IAW AMM 25-31. OPS CHECKED NORMAL.SDR CALA2014030390499Oven · malfunctionedCONTROL PANEL AT 2L SHORTED OUT & ELECTRICAL SMOKE SMELL. INVESTIGATED SOURCE OF ODOR & IDENTIFIED OVEN R32, DOCUMENTED AT PTT 6262004. CREW TERMINAL AT 2L IS FAULTED WITH ELECTRIC NOISE, DEACTIVATED CONNECTOR J1 & GND 1 AS PRECAUTION. CREW TERMINAL IS INOPSDR V0XD201402040023Fitting · corrodedGALLEY 1 HAS THREE CORRODED FLOOR FITTINGS. REPLACED THREE CORRODED GALLEY FLOOR FITTINGS PN`S 9331091-3, CDSP 2019-7C760 & A661091-1 IAW C & D ZODIAC CMM 25-33-42.SDR DXTA2014022405666Oven · defectiveOVEN IS INTERMITTENTLY INOPERATIVE. WHEN IT WORKS & IS USE THERE IS AN ODOR OF BURNING ELECTRONICS OR WIRING. REMOVED OVEN PN 50231L-OVS280, SN 0099 & INSTALLED A REPAIRED OVEN PN 50231L-OVS280, SN 0201, OPERATIONS CHECKED GOOD.SDR AALA20140218002Coffeemaker · malfunctionedCDG CREW REPORTED SMOKE IN FWD GALLEY EMANATING FROM OVERHEAD VENT FWD OF CEILING LIGHT. UTILITY SWITCHES SELECTED OFF. FLIGHT LANDED CDG WITHOUT INCIDENT. FOUND COFFEE MAKER 2 BURNED OUT WITH A SPREAD OF WHITE POWDER. REPLACED NR 2 COFFEE MAKER. SYS GND SDR USAA2014021700023Chiller · faultyCREW REPORTED THE FWD GALLEY CHILLER PRODUCING A HIGH PITCH NOISE. UPON TURNING CHILLER OFF, FLIGHT ATTENDANT REPORTS A BURNING ODOR. FLIGHT RETURNED TO THE GATE. MX TROUBLESHOT CABIN AIR QUALITY IAW JOB CARD 26L00021001 ALONG WITH CABIN ODOR REPORT. FOUND SDR V0XD2014021122Mount Fitting · corrodedNUMBER 1 GALLEY MOUNTING FEET CORRODED 4. R & R 1 GALLEY FEET 4 IAW CMM 25-33-42. PN FOR FITTINGS, TWO EACH CDSP 2019-7C620, ONE EACH A661091-1 & ONE EACH COSP 2019-7C760.SDR SWAA2014021725180Coffeemaker · dirtyFAINT ELECTRICAL ODOR WAS COMING FROM FWD COFFEE POTS. PULLED CB`S & ODOR WENT AWAY. CLEANED RESIDUE UNDER COFFEE MAKER & HOT PLATE IAW MM.SDR USAA2014020300027Coffeemaker · faultyACRID ELEC ODOR EMANATING FROM FWD GALLEY. REPLACED FWD COFFEE MAKER, FOUND COFFEE MAKER SMOKING DURING BREW CYCLE.SDR CA140204002Coffeemaker · failed(CAN) DURING FLIGHT THE CREW REPORTED 1 OF THE AFT COFFEEMAKERS PRODUCING SMOKE. THE CABIN UTILITY POWER WAS TURNED OFF AND THE SMOKE DISSIPATED. A MAINTENANCE INVESTIGATION WAS CARRIED OUT RESULTING IN THE REPLACEMENT OF BOTH AFT COFFEEMAKERS AS THE SOURCE OSDR CALA2014011390122Hose · damagedLEAK FOUND BELOW CHILLER UNIT AT LOWER PANEL, AT CHILLER DRAIN HOSE ATTACH FITTING. NEW CLAMP INSTALLED, NEEDS NEW HOSE, STILL LEAKS. REPLACED HOSE, LEAK CHECKED OK, REPLACED CHILLER, SUSPECT ICING IAW MM 25-34-51. OPERATIONS CHECKED OK, SECURED ALL PANELS.SDR DALA14000943701Oven · failedDURING FLIGHT, SMOKE AND FUMES WERE REPORTED IN CABIN AND COCKPIT. ACFT DIVERTED. MAINTENANCE FOUND FORWARD GALLEY OVEN WITH BURNED ELECTRICAL ODOR. REPLACED FORWARD GALLERY OVEN, OPS TESTED OK, ACFT RETURNED TO SERVICE.SDR DXTA2013123005609Oven · failedOVEN BILLOWED SMOKE WHEN TURNED ON. HAS A BURNING ELECTRIAL ODOR, OVEN CIRCUIT BREAKER PULLED. REMOVED AND REPLACED OVEN IN THE AFT GALLEY IAW CCM 25-37-01. OPS CHECKED GOOD.SDR USAA2013122600005Oven · odorBURNT ELEC WIRE SMELL COMING FROM OVEN NR 1 IN FWD GALLEY. REMOVED NR 1 OVEN IN FWD GALLEY INSERT. OPERATIONS NORMAL IAW A319 AMM CHAPTER 20.SDR CALA2013122300932Oven · odiferousOVEN HAS BAD ODOR FWD GALLEY LT. R & R OVEN ROTABLE PARTS CHANGE WAS INDICATED TT 1617271, SN OFF 02073 OVEN, SMALL, ST OFF 29-2532-9-0001 2073 & ON 29-2532-9-0001 3190.SDR CALA2013122393888Bar · shearedLOWER GALLEY CART LIFT SAFETY BAR SHEARED OFF.SDR DALA13070845805Fan · contaminatedFORWARD GALLEY OVENS SMOKE WHEN ON FOR COOKING. REMOVED TRAY ASSY. FOUND PLASTIC MELTED ON FAN GUARD, REMOVED AND CLEANED FAN GUARD, OK FOR SERVICE.SDR DALA13070340660Coffeemaker · odorF/A REPORTED STRONG ELECTRICAL ODOR, SUSPECTED COFFEEMAKER AT POSITION M301,TURNED OFF COFFEEMAKER AND ODOR DISSAPATED. R & R COFFEEMAKER, OPS CHECKED GOOD.SDR CALA2013121393661Guide · gougedAUXILIARY GALLEY CART LIFT MAKING VERY LOUD SCRAPING SOUND. CHECK OPERATION OF LIFT CART, FOUND AFT GUIDE RAIL SHOWS SIGNS OF GOUGE STARTING HALFWAY UP & GETTING PROGRESSIVELY DEEPER AS IT GETS TO THE BOTTOM. ROLLER CARRIAGES LOOK WORN, DUE TO EXCESSIVE PLAYSDR CALA2013121793764Oven · contaminatedCREW REPORTED SMOKE IN THE MID GALLEY OVEN AREA. FOUND HEATING ELEMENT CONTAMINATED BY GRAVY.SDR USAA2013121100007Coffeemaker · faultyAN ACRID ODOR COMING FROM FWD GALLEY, MAYBE COOLER FREON, SLIGHT EYE BURNING SENSATION. NOTICED ODOR AT IDLE THRUST IN DESCENT. ALL OTHER BLEED SYSTEMS CONFIGURED NORMAL. FLIGHT LANDED WITHOUT INCIDENT. ACCOMPLISHED JOB CARD 26L00021001, TROUBLE SHOT CABINSDR AALA20131207001Coffeemaker · overheatedLHR CREW REPORTED ELECTRICAL SMELL & HAZE IN REAR OF AIRCRAFT NEAR LT & RT NR 4 DOORS. TURNED OFF INFLIGHT ENTERTAINMENT MAIN POWER SWITCH & POWER TO PC PORTS. FLIGHT LANDED LHR WITHOUT INCIDENT. REPLACED COFFEE MAKER THAT HAD OVERHEATED. SYSTEM GND CHECKESDR DALA13066941804Oven · failedTHE CABIN CREW REPORTED A SLIGHT BURNING RUBBER ODOR COMING FROM THE FORWARD GALLEY. THE ODOR OCCURRED ONE HOUR IN CRUISE. THE CREW REPORTED THE ODOR DISSIPATED WHEN GALLEY CIRCUIT BREAKERS WERE PULLED. MAINTENANCE FOUND EVIDENCE OF A BURNED ODOR AND BURNS FSDR SWAA2013121123135Coffeemaker · faultyELECTRICAL ODOR NOTICED IN FWD GALLEY ON DESCENT FLIGHT ATTENDANT NOTICED TRACE OF SMOKE. FOUND FWD COFFEE MAKER RACK J6 HARNESS BURNING BLACK AREA AT HOLD DOWN CLAMP ON BACK OF COMPARTMENT. R & R FWD COFFEE MAKER RACK & HARNESS ASSEMBLY IAW MM.SDR CALA2013120693525Unknown · odorFLT ATTENDANTS SAY THEY CAN DETECT AN ODOR IN THE AFT GALLEY, ODOR OF JET FUEL ONE HOUR INTO. DEFERRING AFT GALLEY FWD SECTION CHILLER DUE TO SMELL WHEN CARTS PLUGGED IN, WHEN CARTS REMOVED THERE IS NO SMELL UNLESS YOU OPEN CHILLER PORTS WITH UNIT RUNNING. PSDR ASAA2013112996564Oven · smokeINBD OVEN IN FWD GALLEY STARTED SMOKING SLIGHTLY AFTER 20 MINUTES 275, SMOKE STOPPED WHEN OVEN WAS TURNED OFF. ACFT GROUNDED. R & R INBD OVEN IN FWD GALLEY IAW AMM 25-32-01-401. ACCOMPLISHED OPS CHECK IAW AMM 25-32-01-401.SDR CALA2013120293376Relay · faultyAFT GALLEY CHILLERS INOPERATIVE. REPLACED GALLEY DC POWER RELAY K25008 IAW FIM 25-31 TASK 807, OPERATIONS CHECKED NORMAL.SDR CALA2013120200881Oven · dirtyOVEN 107 HAD SOME SMOKE & ODOR WHEN USED 2ND TIME IN FLIGHT. ODOR DID NOT APPEAR TO BE ELECTRICAL, SMELLED LIKE HOT PLASTIC. PERFORMED CONDITIONAL INSPECTION IAW AMM TASK 05-51-58-200-801C 1, OPERATIONS CHECKED NORMAL AFTER CLEANING OF SPILLED FOOD.SDR DXTA2013112505580Microwave Oven · faultyFLIGHT ATTENDANT WENT TO USE THE MICROWAVE IN GALLEY & UPON STARTING THE MICROWAVE, WHITE ELEC SMOKE BEGAN SPEWING FROM BEHIND OR IN THE MICROWAVE. DESELECTED THE GALLEY MASTER SWITCH IN THE COCKPIT & THE SMOKE STOPPED. R & R THE GALLEY MICROWAVE ASSEMBLY WISDR CALA2013112593241Chiller · overheatedCHILLER 713 OVERHEATING.SDR CALA2013112093143Coffeemaker · dirtyTHE INBOUND CABIN CREW REPORTED TO CUSTOMER SVC THERE WAS AN ELECTRICAL BURNING SMELL IN THE CABIN. NO LOCATION & NO WRITE UP WITH NO SMOKE IN CABIN REPORT INITIATED. THE FLIGHT ATTENDANT WHO REPORTED THE BURNING SMELL RETURNED TO THE ACFT TO POINT OUT THE LSDR SIMA20131117001Coffeemaker · odorCOFFEE MAKER EMITTING SUSPICIOUS ODOR. SPECIFICALLY THE RT COFFEE MAKER. REMOVED, CLEANED & REINSTALLED COFFEE MAKERS 1 & 2. OPS CK NORMAL REF AMM 25-32-06SDR ASOA20131115200Coffeemaker · smokeDURING GROUND OPERATIONS, THE CREW NOTED A SMOKE ODOR IN CABIN AND ELECTED TO RETURN TO THE GATE. MAINTENANCE DETERMINED THE SOURCE OF THE SMOKE TO BE THE RT COFFEE BREWER. THE BREWER WAS REPLACED, OPS CHECKS PERFORMED AND THE DISCREPANCY CLEARED.SDR CALA2013110892755Filter · cloggedWATER LEAKING IN AFT GALLEY. FLIGHT ATTENDANTS STATED THAT THERE WAS VISIBLE SMOKE & ACRID SMELL COMING FROM BETWEEN THE GALLEY CARTS & THE GALLEY COUNTER. COULD FIND NO EVIDENCE OF ANY COMPONENT CAUSING ODOR OR SMOKE, OPERATED ALL GALLEY COMPONENTS & LIGHTISDR CA131030001Oven · fod(CAN) AFTER PUSHBACK THE CABIN CREW REPORTED AN ELECTRICAL BURNING ODOR IN THE AFT GALLEY. THE FLIGHT RETURNED TO THE GATE FOR INVESTIGATION. OVEN NOTED TO BE CONTAMINATED WITH FOOD DEPOSITS. OVEN CLEANED, C/B RESET, FUNCTION CHECKED, NO RECURRENCE OF ODOR SDR CA131029007Coffeemaker · failed(CAN) APPROXIMATELY 2 HRS AFTER TAKEOFF THERE WAS A STRONG BURNING ODOR FROM COFFEEMAKER 1 OR 2 FOLLOWED BY AN ORANGE FLASH AND A PUFF OF WHITE SMOKE. THE CIRCUIT BREAKERS WERE PULLED AND THE CREW REPORTS ALL OK AT THIS TIME RESOLUTION: REPLACED COFFEEMAKER SDR CALA2013103192545Shelf · damagedSHARP METAL EDGE ON AFT GALLEY SHELF. REPAIRED DAMAGE.SDR DALA13055665804Seal · wornCREW REPORTED THAT AFTER TURNING ON OVENS, LIGHT SMOKE APPEARED. NO ODOR OR COLOR, TURNED OVENS OFF AND SMOKE DISSIPATED. MAINTENANCE FOUND DOOR SEALS ON OVEN NR 1 & 2 WERE WORN AND NOT SEALING AGAINST OVEN DOORS. REPLACED FWD GALLEY TRIPLE OVEN ASSY, OPS CSDR CALA2013102492353Control Panel · faultyAFT GALLEY EQUIP CONTROL PANEL ABNORMALLY WARM & UNABLE TO CONTROL. FLIGHT DIVERTED
Back to JASC 2530