JASC 2530

Service difficulty reports · 4,471

Reports filed under 2530 · Buffet/Galleys, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2530'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR CALA2013102592385Control Panel · faultyAFT GALLEY EQUIPMENT CONTROL PANEL FAULTY, FLT DIVERTED. NO SMOKE OR ELECTRICAL SMELL ASSOCIATED WITH WARM PANEL. ACCOMPLISHED CHECK OF CM IAW MM25 -35-00-710-013A, RAN CHILLER IAW MM25-34-00-710-001A, OPERATED LIGHTING & HOT PLATE. MONITORED PANEL NO INDICOct 23, 2013 · N442UA · Airbus A320232SDR USAA2013102400006Coffeemaker · sparksF/A REPORTS THAT THE NR 1 AFT COFFEEMAKER SPARKS AND POPS. MAINTENANCE R & R NR 1 AFT COFFEEMAKER IAW AMM 25-35-15.Oct 23, 2013 · N812AW · Airbus A319132SDR YENA20131023217Coffeemaker · odorF/A NOTICED AN INTERMITTENT BURNING ODOR IN THE AFT GALLEY. PERFORMED DETAILED VISUAL INSPECTION FOUND COFFEEMAKER 507 WITH SLIGHT ELECTRICAL ODOR. NO OTHER DEFECTS NOTED APU BLEED ON ALL LIGHTING ON. NO DEFECTS NOTED. CHANGED COFFEEMAKER AS PRECAUTIONARY IOct 23, 2013 · N565JB · Airbus A320232SDR AALA20131022013Oven · dirtyELP INFLIGHT LAX-DFW. SMOKE IN THE FLIGHT DECK. EMERGENCY DECLARED FLIGHT DIVERTED ELP LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FOM SERVICE. FOUND FIRST CLASS OVENS WERE DIRTY CAUSING SMOKE. REMOVED LARGE AMOUNTS OF FOOD DEBRIS & OIL FROM AFT CORNERS OF Oct 22, 2013 · N688AA · Boeing 757223SDR USAA2013102100008Chiller · failedCREW REPORTED THE FWD GALLEY CHILLER WAS MAKING A STRANGE NOISE, BAD BEARINGS AND A BURNING ODOR WAS GIVEN OFF. GALLEY CONTROL PANEL WAS HOT TO THE TOUCH AND THE CHILLER BREAKER TRIPPED. ODOR DISSIPATED. MAINTENANCE R & R THE FORWARD GALLEY CHILLER IAW AMM Oct 19, 2013 · N703UW · Airbus A319112SDR ASOA20131017119Unknown · odorCREW REPORTED A STRONG ELECTRICAL ODOR COMING FROM COFFEEMAKER WHEN TURNED ON, ODOR WENT AWAY WHEN TURNED OFF. MX PERFORMED OPS CHECK OF THE COFFEEMAKER WITH NO FAULTS NOTED. ACFT WAS APPROVED FOR RETURN TO SERVICE.Oct 17, 2013 · N11539 · Emb EMB145LRSDR CA131017001Oven · failed(CAN) SMOKE ODOR IN MID GALLEY. BREAKERS PULLEY, ODOR DISSIPATED. NO FOOD OR PLASTIC IN OVENS, APPEARS TO BE IN WIRING. SMOKE ODOR FROM OVEN CONTROLLER, TOP OF OVEN VENT AND BACK OF THE OVEN. OVEN FAN MOTOR CHECKED , THERE IS BLACK MARKER IN IT. GALLEY WIOct 16, 2013 · Boeing 767333SDR RJEF20131011009Coffeemaker · odorDURING FLIGHT, PILOT REPORTED ELECTRICAL FUMES DETECTED FWD AND AFT GALLEY, ACFT DIVERTED AND DECLARED AOG. MAINTENANCE PERFORMED TSM 05-50-00-810-831-A. FOUND FWD COFFEE MAKER RESPONSIBLE.Oct 11, 2013 · N492TA · Airbus A320233SDR CALA2013101191959Terminal · brokenTHREE BROKEN TERMINAL STRIPS ON BOTTOM SIDE OF MID GALLEY TABLE TOP. AFFECTED TERMINAL STRIPS ARE M25231TB02 & M25231TB03 UNDER THE FWD MID GALLEY TABLE TOP & M2532TB05 UNDER THE AFT MID GALLEY TABLE TOP. IAW WDM 25-32- 22 PG 1 SHT 2 & WDM 25-32-21 PG 1. REOct 10, 2013 · N214UA · Boeing 777222SDR CA131010006Coffeemaker · odorTHE AFT COFFEEMAKER CIRCUIT BREAKER 1-2 POPPED, THERE WAS A ODOR OF SMOKE WHICH DISIPATED. BOTH COFFEEMAKERS WERE REMOVED AND INSPECTED. LT COFFEEMAKER CHECKED SERVICEABLE. RT COFFEEMAKER HAD DISCOLORED TERMINALS. RT COFFEEMAKER WAS REPLACED.Oct 9, 2013 · Boeing 7377CTSDR CALA2013100891857Oven · dirtySMOKE COMING FROM OVEN WARMER W51 AFT GALLEY. ONLY FOUND SPILLED & MELTED CHOCOLATE SYRUP, NO ELECTRICAL HAZARD. SOURCE OF SMOKE IAW IADMM WAS THE SPILLED SYRUP. IAD VERIFIED NO OTHER DEFECTS WITH THE OVEN. OVEN INOPERATIVE TILL SYRUP CAN BE PROPERLY CLEANOct 8, 2013 · N775UA · Boeing 777222SDR UIEA2013100800512Oven · smokeOVEN STARTED SMOKING DURING USE. DISCONTINUED AND BREAKERS PULLED.Oct 7, 2013 · N499MC · Boeing 74747UFSDR AALA20131001004Oven · faultyLHR FLIGHT ATTENDANTS REPORTED OVEN 2 OVERHEATING WITH BURNING ELECTRICAL SMELL IN FLIGHT. FLIGHT LANDED LHR WITHOUT INCIDENT. FIRST CLASS OVEN 2 DEFERRED IAW NEF 25N33A/AUTH 10-5NEF-C. REPLACED NR 2 WARMING OVEN AT DFW ON 10/02/2013. SYSTEM GROUND CHECKEDOct 1, 2013 · N782AN · Boeing 777223SDR SWAA2013100320766Coffeemaker · faultyDURING DESCENT STRONG BURNING SMELL IN AFT GALLEY. R & R NR 2 COFFEE MAKER IAW AMM.Sep 30, 2013 · N527SW · Boeing 7375H4SDR DALA13051179232Oven · contaminatedFIRST CLASS GALLEY OVEN STARTED SMOKING WHEN IT WAS TURNED ON. MX INSPECTED CONTENTS OF OVEN, NO SPILT FOOD OR SAUCE. FD TO MCO/PLAC IAW MEL 25-34-02. CIRCUIT BREAKER PULLED AND COLLARED. PERFORMED VISUAL INSPECTION OF OVEN. FOUND COOKED MEALS IN THE OVENSep 26, 2013 · N932DN · Doug MD9030SDR USAA2013092300039Spring · inoperativeAFT GALLEY TRASH BIN ACCESS DOOR FLAP NOT SPRINGING CLOSED. REPLACED SPRINGS ON AFT GALLEY TRASH FLAP.Sep 21, 2013 · N507AY · Airbus A321231SDR ANCF2013190900167Coffeemaker · failedON GROUND, COFFEMAKER 1 STARTED TO PRODUCE SMOKE. COFFEMAKER REPLACED IAW AMM 25-85-12-000/400-001-A, TESTED OK.Sep 19, 2013 · N595EL · Airbus A318111SDR R61A201309180887Heater · contaminatedF/A REPORTED A BURNING ODOR IN THE AFT GALLEY AREA AND CAPTAIN NOTED A FAINT ODOR IN THE COCKPIT. NO SMOKE WAS VISIBLE AND ODOR WAS NOT STRONG, BUT NOTICEABLE. ATC DECLARED AN EMERGENCY. LANDED AND TAXIED TO GATE WITHOUT INCIDENT. MX INSPECTED AND FOUND DESep 18, 2013 · N214WQ · Bombdr DHC8402SDR SIMA20130918001Coffeemaker · odorHOT ODOR REPORTED IN GALLEY. TURNED OFF AND PULLED BOTH COFFEEMAKER CIRCUIT BREAKERS, HOT ODOR REPORTED GONE. R & R COFFEEMAKER . OPS CHECKED OK, NO ODOR NOTED, NO DEFECTS NOTED IAW SRM.Sep 18, 2013 · N852AE · Emb EMB135KLSDR CALA2013091891275Coffeemaker · defectiveFWD GALLEY COFFEE MAKER MADE A POPPING NOISE & A LITTLE SMOKE WHEN BREW BUTTON PRESSED.Sep 16, 2013 · N523UA · Boeing 757222SDR SIMA20130916006Cart · odorF/A REPORTS THAT ONE OF THE GALLEY CARTS SMELLS LIKE A DEAD ANIMAL. CLEANED INSIDE OF BOTH GALLEY CARTS. NO DEFECTS OR ODORS NOTED. OK FOR SERVICE.Sep 16, 2013 · N693AE · Emb EMB145LRSDR ASMF201310002Oven · contaminatedACFT RETURNED TO PLATFORM, F/A REPORTED THAT A WIRE BURNED ODOR AFTER AFT GALLEY OVENS TURNED ON. MAINTENANCE PERFORMED SMOKE OR FUMES IN CABIN CONDITIONAL INSPECTION IAW MM 05-51-56, DETECTING PAPER BURNED PROPERTY OF CATERING; THE PAPER WAS REMOVED AND AFTSep 15, 2013 · N342AM · Boeing 737832SDR USAA2013091300001Oven · odorCIRCUIT BREAKERS WERE PULLED ON OVENS, DUE TO A PLASTIC OR ELECTRICAL ODOR. MX R & R THE OVEN AT 6 -11.Sep 11, 2013 · N286AY · Airbus A330243SDR DJFA20130910001Microwave Oven · smokeCREW REPORTED SMOKE EMANATING FROM THE MICROWAVE OVEN WHILE COOKING FOOD. EVALUATION REVEALED SMOKE PRESENT WITH NO CONTENTS IN THE OVEN. OPENSep 10, 2013 · N26MJ · Cessna 750SDR ASOA20130910106Unknown · odorA BURNING ODOR COMING FROM THE COFFEEMAKER WAS REPORTED. MX INSPECTED COFFEE BREWERS WIRING, TERMINALS IAW EA2530-01035 WITH NO DEFECTS NOTED. ALSO, PERFORMED OPS CHECK, TEST OF COFFEE BREWERS 1 AND 2 AND COULD NOT DUPLICATE FAULT. BREWERS OPS CHECK GOOD. Sep 10, 2013 · N18557 · Emb EMB145LRSDR CALA2013090991103Cart · defectiveFOUR PIGTAILS AFT GALLEY INOPERATIVE. REPLACED ALL CARTS NOW OKSep 6, 2013 · N179UA · Boeing 747422SDR CALA2013090691088Oven · contaminatedR31 BC OVEN SMOKING WHEN-HEATING. CLEANED REMNANTS OF PLASTIC BAG FROM OVEN & OPERATIONS NORMAL.Sep 6, 2013 · N225UA · Boeing 777222SDR R61A201309040854Structure · corrodedWHILE IN HEAVY CHECK, AFT GALLEY TRIM IS CORRODED ON FWD AND AFT MOUNTING SURFACES. MX R & R DAMAGED TRIM IAW WITH AMM 25-0023, 25-00-05.Sep 4, 2013 · N104HQ · Emb ERJ170200LRSDR VQI2013F00029Oven · failedTHE CABIN CREW NOTED THE FWD GALLEY OVEN CIRCUIT BREAKER TRIPPED. ITL NOTED SOME SMOKE INSIDE THE OVEN AND RESECURED THE DOOR CLOSED. UPON ARRIVAL TO DESTINATION, MX R & R THE OVEN IAW AMM 25-35-19-000-001A AFTER CONFIRMED BAD. NO FURTHER INCIDENTS HAVE OCCSep 3, 2013 · N849VA · Airbus A320214SDR CA130906006Coffeemaker · shorted(CAN) COFFEEMAKER STARTED SMOKING, BREAKER WAS PULLED, IT DIDNT POP AND ABOUT A MIN LATER THE SMOKE CLEARED, PASSENGER CONVENIENCE ITEMS, VARIOUS. COFFEEMAKER WAS REPLACED.Aug 31, 2013 · Dhav DHC8103SDR CA130910002Oven · smoke(CAN) DURING CRUISE, OVEN IN USE, SMOKE FROM TOP OF UNIT. G3 GALLEY CIRCUIT BREAKER OPENED TO ISOLATE OVEN POWER. NO FUTHER FLIGHT ACTIONS REQUIRED. OVEN REMOVED FROM AIRCRAFT AND ROUTED TO MFG FOR ANALYSIS.Aug 30, 2013 · Bombdr DHC8400SDR CALA2013090290918Oven · fireGALLEY OVEN 105R11 TOO HOT. FIRE IN OVEN WAS PUT OUT BY FLIGHT ATTENDANT. COMPLETED FORM 46-6020 FOR SMOKE-ODOR QUESTIONNAIRE. CARDBOARD TOP FOR THE COOKIE TIN THE COOKIES CAME IN CAUGHT FIRE. REMOVED DEBRIS FROM OVEN & PLACED NR 1 OVEN IN FIRST CLASS ON MEAug 30, 2013 · N802UA · Airbus A319131SDR CALA2013083090872Oven · dirtyMID GALLEY HAS SMOKE. WARMER OVEN W33 SMOKES WHEN IN USE. FOUND BURNED CHOCOLATE IN OVEN.Aug 29, 2013 · N799UA · Boeing 777222SDR ASOA20130829069CCoffeemaker · smokeTHE CREW REPORTED INFLIGHT THE COFFEE POT SMOKED AND SMELLED OF BURNED POPCORN. THE COFFEEMAKER WAS IMMEDIATELY TURNED OFF. THE COFFEE MAKERS WERE PLACED ON MEL/NEF. MX INSPECTED AND PERFORMED OPS CHECKS AND FOUND NO DEFECTS WERE FOUND. THE ACFT WAS RELEASED Aug 29, 2013 · N11551 · Emb EMB145LRSDR CALA2013083090888Oven · odorFIRST CLASS OVEN ON LT SIDE PRODUCED SMOKE AFTER A FEW MINUTES OF USE. INOPERATIVE 1ST CLASS OVEN NR 1 PRECAUTIONARY, FOUND SMALL AMOUNT OF BURNT SPILLED FOOD ON OVEN INSERT. OVEN STILL PRODUCED SMELL WITH INSERT REMOVED. OVEN NR 1 IS NOT TO BE USED. PARTSAug 29, 2013 · N585UA · Boeing 757222SDR YENA20130828193Coffeemaker · odorBURNING ODOR DISCOVERED ENROUTE, COMING FROM FRONT COFFEEMAKERS. CIRCUIT BREAKERS PULLED. COFFEEMAKER WAS REMOVED AND REPLACED IAW AMM 25-35-15. OPS CHECKED OK.Aug 28, 2013 · N591JB · Airbus A320232SDR DALA13040045525Oven · smokeAT CRUISE THE F/A REPORTED SMOKE FROM F/C OVENS. THEY TURNED OVENS OFF AND SMOKE STOP IAW QRH. MX AND DISPATCH ADVISED TO CONTINUE FLIGHT. ONCE ON GROUND MX RAN OVENS FOR 20 MINUTES AND NO SMOKE OF FUMES.Aug 20, 2013 · N525US · Boeing 757251SDR CALA2013082090582Door · missingUPPER DECK CART ELEVATOR DOOR DAMAGED. FOUND UPPER DECK CART ELEVATOR VIEW WINDOW MISSING. DEACTIVATED CART LIFT SYSTEM.Aug 19, 2013 · N105UA · Boeing 747451SDR ASAA2013081995850Oven · smokeFUMES IN CABIN ON CLIMBOUT. F/A GETTING NAUSEOUS WITH TINGLING LIPS, LIGHT HEADED. RETURNED TO DEPARTURE. MAX ALT 18,000. RAN QRH CHECKLISTS AS ABLE WHILE RAPIDLY RETURNING TO DEPARTURE. AIR QUALITY CLEARED AS WE DESCENDED AND TAXIED IN. PARAMEDICS MET ACFAug 19, 2013 · N619AS · Boeing 737790SDR R61A201308160787Structure · corrodedDURING HEAVY CHECK, AFT GALLEY SPLIT JOINTS ON FWD SECTION, AND TRIM STRIPS HAVE CORROSION. MX R & R SPLIT JOINTS ON FWD SECTION AND ALL TRIM STRIPS IAW SRM 51-40-00 & AMM 25-00-23, 25-0017, 25-00-10, PN 170-87021-001, FITTING, TRIM 170-59522. ACFT REMAINS FAug 16, 2013 · N811MD · Emb ERJ170100SUSDR R61A201308150797Spigot · corrodedDURING HEAVY CHECK, FOUND AFT GALLEY WATER SPIGOT CORRODED. MX R & R AFT GALLEY WATER SPIGOT IAW MM 25-33-80.Aug 15, 2013 · N115HQ · Emb ERJ170200LRSDR CALA2013081690495Chiller · malfunctionedF/A REPORTS BEING SHOCKED ON GALLEY WHEN SWITCHING FROM EXTERNAL TO APU POWER. ISOLATED PROBLEM TO GALLEY CHILLER. COLLARED BREAKER, NO FURTHER PROBLEM WITH SHOCKING.Aug 15, 2013 · N829UA · Airbus A319131SDR SWAA2013081619270Coffeemaker · faultyCREW REPORTS SMELL IN CABIN WITH RECIRCULATING FAN ON IN AFT CABIN. R&R AFT INBD COFFEE MAKER IAW MM.Aug 14, 2013 · N470WN · Boeing 7377H4SDR USAA2013081600003Oven · unserviceableF/A REPORTED A STRONG ROTTEN EGG/SULPHUR ODOR IN FWD GALLEY AREA AS TAXI WAS INITIATED. ODOR DISSIPATED AFTER APPROX 5 MINUTES AND DID NOT REOCCUR DURING REMAINDER OF FLIGHT. MX ACCOMPLISHED J/C 26L00021001, TROUBLESHOOT CABIN AIR QTY. INSPECTED APU AND NR 1Aug 14, 2013 · N712US · Airbus A319112SDR CALA2013081490439Coffeemaker · odorMELTED PLASTIC ELECTRICAL ODOR IN FWD GALLEY. REPLACED COFFEEMAKER. NO FURTHER ODOR OR ELECTRICAL SMELL IN FWD GALLEY.Aug 14, 2013 · N843UA · Airbus A319131SDR USAA2013081200014Coffeemaker · smokeCREW REPORTED THE AFT LEFT COFFEEMAKER WAS EMITTING SOME SMOKE AND ELECTRICAL ODOR. CREW REMOVED POWER TO UNIT. MX R & R AFT LT COFFEEMAKER.Aug 9, 2013 · N716UW · Airbus A319112SDR YENA20130806172Coffeemaker · odorAFT GALLEY COFFEEMAKER INBD WAS PRODUCING A BURNING ODOR AND TRIPPED THE BREAKER ITSELF. ONCE TRIPPED, ODOR DISSIPATED. REMOVED COFFEEMAKER, BURNING ODOR WENT AWAY. CHECKED ELECTRICAL CONNECTOR NO DEFECTS NOTED. INSTALLED NEW COFFEEMAKER PERFORMED OPS CHEAug 6, 2013 · N317JB · Emb ERJ190100IGWSDR ASOA20130806197Coffeemaker · fireDURING FLIGHT, FIRE AND SMOKE AT COFFEEMAKER IN GALLEY. INSPECTED SURROUNDING STRUCTURES AND FOUND DAMAGE TO BE CONTAINED TO GALLEY ONLY. R & R AFT GALLEY IAW AMM 25-30-02. ACFT WAS APPROVED FOR RETURN TO SERVICE.Aug 6, 2013 · N13124 · Emb EMB145XRSDR CA130806004Coffeemaker · overheated(CAN) THE AFT LT COFFEEMAKER STARTED SMOKING IN FLIGHT. THE CREW REMOVED POWER TO THE COFFEEMAKER, PULLED THE ASSOCIATED CIRCUIT BREAKER AND THE SMOKE DISSIPATED. THE COFFEEMAKER WAS DIFFERED THEN LATER REPLACED. NO OTHER ISSUES WERE NOTED.Aug 5, 2013 · Boeing 7377CTSDR CALA2013080590132Insert · missingMETAL HOLDING UP PIGTAIL UNATTACHED. TWO INSERTS IN UNDERSIDE OF COUNTER MISSING, REMOVED PIGTAIL AND GUARD AT P61, CIRCUIT BREAKER COLLARED.Aug 4, 2013 · N654UA · Boeing 767322
Back to JASC 2530